Manual

FCC ID: Q9R-5100

Users Manual

Download: PDF
FCCID_344279

IMPORTANT INFORMATION: File this in your TPS records




Total Performance System Consoles
REF 5100-1 Console
REF 5100-50 Irrigation Console



Hermes READY™
REF 5100-201 Console
REF 5100-250 Irrigation Console




User's Guide
••••••••••••••••••••••

       Includes setup, safety, repair, and warranty information for the
       Stryker Total Performance System.

       For answers to questions about other equipment, see the
       information supplied with that equipment.




Version

   4.0            US Patents D398,598; D415,134; 5,543,695; 5,689,159; 6,017,354;
                  6,025,683; 6,045,564; 6,329,778 and other patents pending         4100 E. Milham
                                                                                    Kalamazoo, Michigan
                                                                                    (USA) 49001
                                                                                    1-800-253-3210
                                                                                    1-269-323-7700
6/03                                                        5100-001-709 Rev-A


                                                                      1


2


Contents
Software License Notice .................................................................................... 3

Where to Find Answers ...................................................................................... 4

Warning, Caution, Note Defined ........................................................................ 4

Important Safety Instructions ............................................................................ 5

System Overview
Symbol Definition ................................................................................................ 6

Operating Instructions
Connecting the Equipment
Hermes READY™ TPS Consoles ....................................................................... 7

The Control Screen
TPS Start-Up Screen
No Handpiece Detected Screen ......................................................................... 8

Functions of the Control Screen
Elements of the Control Screen ......................................................................... 9

Select Your System Settings
Standard Features ............................................................................................. 10

Quick Reference Guide (Icon Definition) .......................................................... 11

Handpiece Screens
Saw Handpiece Screen (TPS Oscillating and Sagittal Saws) ........................... 12

Rotary Handpiece Screen
(TPS Universal and MicroDrills & TPS MicroDriver) ........................................... 13

Stryker Endoscopy and Leibinger Handpiece Screen
(SE5 hand-controlled Endo Shaver, QuadraCut Shaver, QuadraCut Bone Plug,
and QuadraCut Small Joint, Hummer 4, Formula, 6K Micro, 12K Micro) ........... 14

Other Screens
Main Option Screen .......................................................................................... 15
System Information Screen .............................................................................. 16
Handpiece Adjustment Screen ........................................................................ 17
Console Adjustment Screen ............................................................................ 18
Footswitch Adjustment Screen ........................................................................ 19
Footswitch Button Mapping Screen ................................................................ 20
Handpiece Button Mapping Screen ................................................................. 21
Surgeon Preference Screen ............................................................................. 22
Messages and Error Messages ....................................................................... 23

Specifications .................................................................................................... 24
Federal Communications Commission Compliance Statement ................... 24

Repair/Loaner Program
Limited Warranty ............................................................................................... 25

Stryker International Subsidiaries ................................................................... 26

Software License Notice
Stryker® TPS™ Surgical Tool System products contain software that is installed in the products by Stryker Corporation. Stryker Corpora-
tion owns this software; this software is never sold. Each sale of a software containing product is not a sale of such software; it includes
only a license to use the software in the product in which the software was initially installed.

Any license granted by Stryker Corporation to use the software contained in its; products does not give the licensee the right to copy,
alter, disassemble, reverse engineer, create derivative works of such software or to use such software in either original or modified form in
any product other than the Stryker Corporation product in which the software was initially installed by Stryker Corporation.

                                                                                      3
                                                                                                                         © 2003, Stryker Corporation


Where to Find Answers

When you have questions about your Stryker TPS products, there are several places to
find the answers.


           In this book

           Use this book to set up your system and select console options. This book also
           contains information on system safety, repair, and component warranty.
           ............................................................................................................................................


           In TPS component instructions

           For answers to questions about any TPS handpiece, attachment, or component , see
           the information supplied with that component. A copy of TPS Cleaning, Maintenance
           and Sterilization Recommendations is also supplied with each component.
           ............................................................................................................................................


           From your Stryker Sales Representative

           If you can't find an answer in any of the materials provided or you have questions
           about other Stryker Instruments products, call your Stryker Sales Representative.
           ............................................................................................................................................


           From Stryker Customer Service

           Please contact our Customer Service Department to order product information
           literature, a cutting accessories guide, additional TPS maintenance manuals, and
           component instructions by dialing 1-800-253-3210. Outside the U.S.A., contact your
           nearest Stryker subsidiary.
           ............................................................................................................................................


           See the TPS Cleaning, Maintenance, and Sterilization Recom-
           mendations booklet for care information.


Warning • Caution • Note

         This symbol is used to alert the reader to important safety and precautionary information.
         When displayed on the actual device, it refers the user to accompanying documents.

Please read this manual and follow all instructions carefully. The words WARNING, CAUTION and
NOTE carry special meanings and should be carefully reviewed.

WARNING:      The personal safety of the patient and/or user may be involved. Disregarding this
              information could result in injury to the patient and/or operating room staff.

CAUTION:      These instructions point out special service procedures or precautions that must be
              followed to avoid damaging the instrument.

NOTE:         This provides special information to make maintenance easier or important instructions
              more clear.




                                                                                          4


          IMPORTANT SAFETY INSTRUCTIONS
WARNING: The personal safety of the patient and/or user may be involved. Disregarding this information
could result in injury to the patient and/or operating room staff. Read and understand the following warnings.

SYSTEM SAFETY
! DO NOT modify ground of power cord.                           ! Burs and blades are intended for single use only.

! Equipment not suitable for use in the presence of             ! Excessive pressure, such as bending or prying, may
  flammable anesthetic mixture with air or with oxygen or         cause accessory to bend or break and cause tissue
  nitrous oxide.                                                  damage to patient and/or operating room staff.

! The Stryker Total Performance System is designed to           ! Heavy sideloads and/or long operating periods
  be used by persons familiar with surgical procedures.           occasionally will cause overheating of the distal tip and
  Misuse may cause injury to both patient and system              the body of handpieces to the point where the hand-
  components. Prior to each use, system components                piece is uncomfortable to hold or causes injury to the
  should be inspected for damage. DO NOT use if                   patient.
  damage is apparent.
                                                                ! If the recommended duty cycle is not followed, the
! Use only Stryker TPS components and accessories                 handpiece may overheat and cause injury to patient
  unless otherwise specified.                                     and/or operating room staff. See the Duty Cycle
                                                                  information supplied with each handpiece.
! Clean and sterilize handpieces and accessories before
  first and every use.                                          ! Excessive pressure, such as bending and/or prying
                                                                  with a bur, may cause the bur to bend or fracture. If
! Use of safety glasses by user and operating room staff          operated at a high speed, it is possible that the bur will
  is recommended to prevent eye injuries.                         bend yet further. This could result in damage to tissue
                                                                  in the surgical site, handpiece vibration that causes lost
                                                                  tactile control, or breakage of the bur such that the
HANDPIECE SAFETY
                                                                  broken piece would be ejected at a high velocity
! Read this booklet and the information supplied
                                                                  endangering the patient and/or operating room staff. It
  with your TPS components. Component instruc-
                                                                  is therefore recommended that safety glasses be used.
  tions provide specific safety information. Refer to
  the instructions supplied with Stryker Endoscopy
                                                                ! Excessive pressure, such as bending and prying with
  handpieces when using those handpieces in
                                                                  blade, may cause the blade to bend or fracture and
  conjunction with the TPS console.
                                                                  could result in damage to tissue in the surgical site
                                                                  and/or loss of tactile control.
! DO NOT attempt to change a saw, bur, or drill while
  handpiece is running.
                                                                ! If using a device with a safety lock, such as a
                                                                  MicroDriver or Universal Handswitch, always place that
! Stryker handpieces which fail due to long life and/or
                                                                  device in the SAFE position when not in use. IMPOR-
  nose bearing failure may allow foreign matter to
                                                                  TANT: Be aware that the TPS footswitch will override
  migrate or emit from the distal tip of the handpiece.
                                                                  the Universal Handswitch SAFE setting.
  Fluid may leak into the surgical site, such that mea-
  sures may be required, per the physician's discretion,
                                                                ! Always use the appropriate accessory combination with
  to protect the patient from infection.
                                                                  a handpiece. Contact your Stryker sales representative
                                                                  for a complete list of accessories. Failure to comply
! Never rest handpiece on the patient. Improper
                                                                  may result in patient and/or operating room staff injury.
  handling of a handpiece could result in damage or
  burns to tissue.
                                                                ! Please note the handpiece starts with rapid accelera-
                                                                  tion when the footswitch or handswitch is activated.
! Do not place a TPS handpiece near or on a magnetic
  pad or tray. The magnetic field can simulate a Univer-
                                                                ! During initial use of your TPS handpieces, monitor the
  sal Handswitch and may cause the handpieces to run
                                                                  heat response in relation to the type of surgical
  inadvertently.
                                                                  procedure being performed. Frequently check the
                                                                  distal tip and body until you are familiar with its
! DO NOT modify any bur to fit the handpieces. Use
                                                                  temperature rise characteristics. Failure to pay close
  only Stryker approved burs. Other burs may not fit
                                                                  attention to handpiece temperature may cause burn
  properly in the handpiece. During use they may come
                                                                  injury to patient.
  out of the handpiece or bend which would result in
  damage to tissue in the surgical site due to loss of
  control of the bur.




                                                            5


System Overview
The Stryker Total Performance System is intended for use in the cutting, drilling, decorticating, and smoothing of bone and
other bone related tissue in a variety of surgical procedures. It is also used for the placement or cutting of screws, wires,
pins, and other fixation devices as it can be used to cut metal.

TPS console powers multiple handpieces while allowing the user to program a number of customized settings. Hermes
READY™ TPS Consoles are designed to interface with Computer Motion's Hermes Operating Room Control Center. The
Hermes system allows voice control and pendant setting adjustment of the SE5 Hand Controlled Shaver REF 272-704-
100 and 12K Hand Controlled Shaver REF 272-704-500.




     Symbol
    Definition




      Power   ON
                                                                                                        TPS Handpiece

      Power   OFF

                                                    TPS Irrigation Console




     Footswitch
                                                                                                                          Stryker
     Connector                                                                                                           Endoscopy
                                                                                                                         Handpiece


      ENDO
  Endoscopy
 Handpiece Port

                                                                                      TPS Handpiece
                                                                                       with Universal
                                                                                        Handswitch


      TPS1
 TPS Handpiece
     Port 1
                                                                                         Handpiece
                                                                                          Cords




      TPS2
  TPS Handpiece
      Port 2




                                                                                                            TPS Footswitch
       Type B
       Applied
       Part


       Type BF
       Applied                Connection Detail
       Part




                                                               6


Operating Instructions
     WARNINGS:

!   Before using this system read and understand the information in this manual and the instructions supplied with each
    TPS component and Stryker Endoscopy handpieces. Pay close attention to the User/Patient Safety Information.

!   Familiarization with the Total Performance System prior to use is important. If you have any questions, contact your
    Stryker Instruments representative or Stryker Customer Service at 1-800-253-3210.

!   Prior to use, system components should be operated and inspected for any damage. DO NOT use if damage is
    apparent.


Connecting the Equipment
This is a system overview. For specific instructions on each TPS component, refer         Hermes READY™ TPS Consoles
to the information supplied with the component.                                           REF 5100-201 and 5100-250
1. Place your console on a sturdy, flat surface near a hospital grade outlet.             A Hermes-Interface cable links the two
                                                                                          systems. Linking the system does not
2. Plug the console's power cord into the recessed power socket on the back of            affect the normal function of the console.
   the console.                                                                           At any time, console functions may be
                                                                                          selected from the control screen or by
3. Plug the other end of the power cord into a hospital-grade wall outlet.                using a control accessory such as a TPS
                                                                                          footswitch.
4. Turn on the console. The on/off switch is located on the front of the console.

    NOTE: As you set up the system, the console's screen will change to indicate the             WARNINGS:
    various components as they are plugged in.
                                                                                          !   Only the Hermes Operating Room
5. If using a Footswitch, plug the footswitch cable into the console port marked
                                                                                              Control Center is approved for use
   FOOTSWITCH. Align orientation marks and gently push connectors together.
                                                                                              with the TPS console. Do not plug
                                                                                              any other device into the Hermes
CAUTION: All TPS Cords have push/pull connectors. Do not thread or twist for
                                                                                              console port. Use of other devices
insertion or removal.
                                                                                              may damage the console.
6. Plug the handpiece cord(s) into the console port(s) identified for the hand-
                                                                                          !   It is important to read and understand
   piece. Align connector orientation marks and gently push connectors together.
   NOTE: Ports marked TPS1 and TPS2 are for Stryker TPS handpieces only.                      the Hermes Operating Room Control
   The port marked ENDO is intended for the following list of Stryker Endoscopy               Center instructions; the use of the
   handpieces: SE5 Handpiece REF 272-704-100, SE5 Hand-controlled REF 272-                    TPS console with the Hermes
   704; QuadraCut Shaver REF 275-701; QuadraCut Bone Plug REF 275-705; and                    Operating Room Control Center is
   QuadraCut small Joint REF 275-601.                                                         explained in those instructions.
   NOTE: If using a TPS Universal Handswitch, attach it to the handpiece before you
   plug the cord into the handpiece.                                                      !   Stryker recommends attaching an
                                                                                              alternate control accessory
7. Plug the other end of the handpiece cord(s) into the handpiece(s).                         (footswitch) to the console in the event
                                                                                              the Hermes System fails during
8. Attach cutting accessories to handpieces. Instructions supplied with each                  surgery.
   handpiece or attachment provide details for cutting accessory assembly.
                                                                                          NOTE: The port labeled DATA PORT is
           WARNING: Use only Stryker approved cutting accessories.                        intended for the manufacturer's use only.

9. If using an Irrigation Console REF 5100-50 or 5100-250, assemble Irrigation            If you have questions about using the
   Pole REF 5100-50-28 to the console as shown. Hang irrigation bag from pole.            Hermes System with the TPS console,
   Install irrigation cassette into the pump. Attach irrigation clips to handpieces and   contact your Stryker Endoscopy
   connect tubing.                                                                        representative or call Stryker Endoscopy
                                                                                          Customer Service at 1-800-624-4422.
Continue to the next step if using a Hermes READY™ TPS Console and Hermes                 Outside the US, contact the nearest
Operating Room Control Center.                                                            Stryker subsidiary.

CAUTION: Use only the Hermes-Interface cable provided by Stryker Endoscopy.

10. Connect the TPS console to the Hermes controller using a Hermes-Interface cable
    into the port labeled Hermes on the back of the console. Plug the other end into
    any available device port on the rear panel of the Hermes controller.

11. Power up both systems and test the devices to ensure they are performing properly
    prior to surgery.



                                                                     7


The Control Screen

                                                                                TPS Start-Up Screen
                                                                                This display appears on the screen every time the
                                                                                console is turned on.

                                                                                This display remains on the screen until a cord is
                                                                                plugged into one of the TPS handpiece ports or the
                                                                                OPT button is depressed.

                                                                                If a handpiece cord is plugged into a handpiece
                                                                                port when the console is turned on, this display
                                                                                shows momentarily before changing to either a no
                                                                                handpiece detected screen or to the screen of the
                                                                                selected handpiece.




                                                                                No Handpiece Detected
                                                                                Screen
                                                                                This image indicates that no handpiece is at-
                                                                                tached to the cord plugged into the selected port.
                                                                                The screen will change to the handpiece screen
                                                                                when the missing handpiece is connected to the
                                                                                cord.

                                                                                NOTE: This screen will also appear if the console
                                                                                is unable to recognize the handpiece. This could
                                                                                be caused by a handpiece that is not compatible
                                                                                with the TPS console, or a faulty or damaged
                                                                                handpiece or cord.

This example shows that no handpiece is attached to the cord plugged into the
TPS2 port.




                                                                           8


Functions of the Control Screen

The TPS console allows the user to select functions and settings such as handpiece selection, speed, and direction.
Designed to be easy to use and understand, the touch sensitive control screen allows you to set the system controls with
the touch of a finger. Interactive icons on the control panel represent system components and functions. The control
screen also provides important monitoring information for the selected handpiece.



                                                                                           Surgeon
                                                                                          preference         Handpiece power
                                                                                           indicator         Indicator ramp

                     Attachment/
   Handpiece         Blade
                                      Handpiece
   identification    identification
                                        speed




                                                                                                       TPS handpiece
                                                                                                       select buttons
                                                                                 Endo handpiece
Select system       Footswitch                                                   select button
options screen      indicator and
                    options



Elements of the Control Screen
Control screen visually presents options which can be set         Handpiece identification displays the name of the active
for the selected handpiece.                                       handpiece. NOTE: Handpieces can be plugged into each
                                                                  of the console's handpiece ports, but only one can be
Icons represent elements of your TPS system. Icons are            selected at a time.
functional buttons. Each function may be selected by
pressing the screen where the button is displayed. When           NOTE: When *CUSTOM* is displayed at the top of the
you touch an icon, the icon appears to be pressed down            screen, the console's default settings are selected from
and the graphic symbol highlights to indicate that it is          Surgeon Preferences. The console is able to capture the
activated. (See Icon Definition).                                 preferred settings for several different users. When this
                                                                  feature is activated, the preferred settings act as default
NOTE: An audible signal indicates interface with icons.           settings. See Surgeon Preference for further details.

NOTE: Buttons such as the adjust arrows or OPT button             Handpiece speed information displays the default speed
which are temporary toggles or adjustment buttons only            for each handpiece until you reset speed settings.
highlight while depressed.                                        While the handpiece is running, the display shows the
                                                                  actual handpiece speed. If the handpiece is not running
NOTE: Buttons with a white background are toggle buttons.         the default or selected speed is displayed.

                                                                  NOTE: Incremental information displayed on the control
NOTE: Options vary among different handpieces. The
                                                                  screen is accurate within +/-1%.
console will only display the options available for a given
handpiece.



                                                              9


Select Your System Settings
                                                                    Standard Features
NOTE: When the console is turned on, its default
setting is factory default unless a Surgeon Preference              Main Option Icon
setting is selected as the start up default. See Surgeon
Preference for further details.
                                                                               The option icon appears on all handpiece screens
1. Handpiece select buttons enable you to activate the                         and allows access to the MAIN OPTION screen.
   handpiece plugged into one of the three ports on the                        See MAIN OPTION SCREEN for further details.
   front of the console. To display the control screen for
   the handpiece plugged into the TPS1 port, touch the
   corresponding handpiece select icon. The icon
   highlights and appears pressed down.

   NOTE: Selecting a handpiece icon activates the
   corresponding handpiece and displays its specific
   control screen.                                                  Footswitch Icon
2. Change the maximum handpiece speed. Press the
                                                                               The footswitch icon only appears when a
   adjustment arrows to change the handpiece speed
                                                                               footswitch is plugged into the console.
   setting incrementally until the desired speed is reached.
                                                                    If using a footswitch with these graph-
   • Saws - The set point is displayed as a percentage of
                                                                    ics, pedal functions can be repro-
   maximum power and vertical line on the speed ramp.
                                                                    grammed. See Footswitch Adjustments
   During handpiece operation, the percentage reading
                                                                    and Footswitch Button Mapping.
   and speed ramp displays the power level.

   • Rotary handpieces - The speed set point is displayed.
                                                                    A footswitch with these graphics
   During handpiece operation, the current speed is
                                                                    cannot be reprogrammed.
   displayed.

3. Select various settings as desired. Refer to the
   control screens on the following pages for details for
   each handpiece.                                                  Handpiece Irrigation
4. Select the OPT icon to access the MAIN OPTION
   screen. This screen allows access to general console             Irrigation functions pertain only to consoles with the built-
   and user settings as well as direct access to each               in irrigation pump REF 5100-50 and 5100-250.
   handpiece option screen.
                                                                               Press the icon to start irrigation flow while the
   NOTE: The screen returns to the active handpiece                            handpiece is running.
   adjustments screen when the handpiece name is
   touched.                                                         If irrigation is desired while the handpiece is stopped, press
                                                                    and hold the icon until the pump is activated. The pump can
5. Touch the EXIT icon to return to the active hand-                be turned off by touching the icon again.
   piece control screen.
                                                                    Irrigation flow rate can be adjusted from the HANDPIECE
                                                                    screen or the HANDPIECE ADJUSTMENTS screen.
                                                                                 From the HANDPIECE screen, toggle the SPEED
                                                                                 icon to WATER before using the arrows to adjust
                                                                                 flow rate.
                                                                                                       -OR-
                                                                                 From the HANDPIECE ADJUSTMENTS screen,
                                                                                 select the WATER icon and use the arrows to
                                                                                 adjust flow rate. Flow rate diminishes as the set-
                                                                                 ting approaches zero.

                                                                               NOTE: Flow rate may vary among handpiece
                                                                               models.

                                                                    The pump can also be turned on and off with the footswitch.




                                                               10


                                              Quick Reference Guide
                                                      Icon Definition

Handpiece Select
         This type of icon appears when              Footswitch Icon: Appears
                                                                                                 High: Enables handpiece to
         a cord (without a handpiece) is             when a footswitch is connected
                                                                                                 operate in a high speed mode.
         plugged into the corresponding              to the console. Also gives
         Endo, TPS1 or TPS2 port.                    access to footswitch adjust-
                                                     ments screen.
                                                                                                 Low: Enables handpiece to
          It appears depressed when                                                              operate in a low speed mode.
          selected.                       Adjustment Arrows: Use in conjunction
                                          with other options to set handpiece
          The handpiece graphic appears speed or power, braking, acceleration,        Toggle Buttons
          when a handpiece is attached irrigation flow, screen contrast etc.          NOTE: For easy identification, only toggle
          to the corresponding cord.                                                  buttons have a white background.
                                                      Increase
          The handpiece graphic                                                                  Speed: Use with the increase
          highlights and the icon appears                                                        and decrease icons to adjust
          depressed when selected.                                                               rotary handpiece speed.
                                                      Decrease
                                                                                                 Water: Use with the increase
                                                                                                 and decrease icons to adjust
                                                                                                 irrigation flow.
System Options
           Options: Gives access to
                                                                                                 Power: Use with the increase
           handpiece adjustments,
                                                                                                 and decrease icons to adjust
           system information, console
                                                                                                 saw power.
           adjustments and user
           preference.
                                           Direction Arrows: Sets handpiece                      Variable: Handpiece speed
                                           mode.                                                 responds to varying degrees of
                    Handpiece option:
                                                                                                 pressure on the footswitch or
                    Accesses corre-
                                                     Forward (clockwise)                         handswitch.
                    sponding handpiece
                    adjustment screens.
                                                                                                 Nonvariable: Handpiece
                                                     Reverse (counterclock-                      operates at constant set-point
           Exit: Returns to previous
                                                     wise)                                       speed/power level.
           screen.
                                                                                                 One touch: Handpiece is
                                                     Oscillate                                   activated by one touch of a
           Information: Displays system
                                                                                                 trigger device and continues to
           information screen.
                                                                                                 run when the trigger device is
                                                                                                 released. Handpiece is
                                                                                                 deactivated by touching any
           Console: Gives access to
                                                     Irrigation: Activates or                    trigger device. In this mode, the
           console adjustment screen.
                                                     deactivates handpiece                       handpiece operates at constant
                                                     irrigation.                                 set-point speed/power level.
           Allows access to the surgeon


                                                                                                Advanced: - Accesses the
                                                                                                advanced footswitch mapping
                                                                                                screen.

                                                                                                Button: Access button
                                                                                                mapping screen.


                                                                                                Return to full screen: Return
                                                                                                from Big to full handpiece
NOTE: TPS Console models REF 5100-1 and 5100-201 do                                             screen.
not display options related to handpiece irrigation.




                                                                 11


Saw Handpiece Screen
                                                                                TPS Oscillating and Sagittal Saws
                                                                                POWER/WATER ADJUSTMENT

                                                                                           The power icon functions as a toggle
                                                                                           switch for power and water settings.



                                                                                           Power and irrigation adjustments are
                                                                                           made using the adjustment arrows.



                                                                                As the power setting is reduced from 100%, a vertical
                                                                                bar displays to correspond to the lower selected
                                                                                maximum power.

This screen appears when a TPS saw is selected at the TPS1 port with the        The irrigation setting is not displayed on this screen.
maximum power set at 100%.                                                      However, it can be seen on the Handpiece Adjust-
                                                                                ments screen.
ENDO, TPS2 and the footswitch icons indicate other instruments are plugged
into the console.

                                                                                METHOD OF OPERATION
                                                                                Saws can be operated with the TPS Universal
                                                                                Handswitch or TPS Footswitch.

                                                                                Handswitch Handpiece selection can be made by
                                                                                depressing the handswitch once. The handpiece
                                                                                select icon changes to indicate the active handpiece.
                                                                                Depress the handswitch again to run the handpiece.

                                                                                Handpiece runs from start-up to the maximum
                                                                                selected speed.

                                                                                Footswitch Handpiece runs from start-up to the
                                                                                maximum selected speed with either the forward or
                                                                                reverse pedal.




                                                                           12


Rotary Handpiece Screen
                                                                                  SPEED/WATER ADJUSTMENT

                                                                                             The speed icon functions as a toggle
                                                                                             switch for speed and water settings.



                                                                                             Speed and irrigation adjustments are
                                                                                             made using the adjustment arrows.


                                                                                  DIRECTION OPTIONS

                                                                                             FORWARD Clockwise


                                                                                             REVERSE Counterclockwise
This screen appears when a TPS rotary handpiece is selected. The TPS Universal
Drill is plugged into the TPS2 port and the speed is set at 75,000 RPM.

ENDO, TPS1 and the footswitch icons indicate that other instruments are plugged              OSCILLATE
into the console.



TPS Universal and Micro Drills
                                                                                  TPS MicroDriver and Universal
METHOD OF OPERATION                                                               Driver
The Universal Drill can be operated with the TPS Universal
Handswitch or TPS Footswitch.                                                     METHOD OF OPERATION
                                                                                  The TPS MicroDriver can be operated with its built-
Handswitch Handpiece selection can be made by depress-                            in trigger and rotary control switch or with the TPS
ing the handswitch once. The handpiece select icon changes                        Footswitch.
to indicate the active handpiece. Depress the handswitch                          NOTE: The handpiece will not run when the rotary
again to run the handpiece.                                                       switch is in the SAFE position.
Handpiece runs from start-up to the maximum selected
                                                                                  Trigger The built-in speed control trigger(s) runs
speed. Speed and cutting direction corresponds to what is
                                                                                  the handpiece from start-up to the maximum
selected on the screen.
                                                                                  selected speed.
Footswitch Handpiece runs from start-up to the maximum
selected speed.                                                                   MicroDriver only: Select cutting direction with the
                                                                                  rotary switch on the handpiece. Direction icon will
Handpiece direction is controlled by selecting the forward or                     highlight to match the rotary switch position.
reverse pedals. The direction icon on the screen changes
when the corresponding footswitch pedal is depressed.                             Universal Driver only: Select cutting direction by
                                                                                  depressing either the forward trigger or the reverse
                                                                                  trigger. Squeezing both triggers simultaneously
                                                                                  runs the handpiece in the oscillate mode. The
                                                                                  oscillate icon will become highlighted.

                                                                                  Footswitch Handpiece runs from start-up to the
                                                                                  maximum selected speed.

                                                                                  The direction icon on the screen changes when the
                                                                                  corresponding footswitch pedal is depressed.

                                                                                  Footswitch operation overrides handpiece settings.
                                                                                  Example: If the footswitch reverse pedal is de-
                                                                                  pressed while the handpiece rotary switch is set in
                                                                                  forward, the handpiece operates in the reverse
                                                                                  direction and the reverse icon highlights. However,
                                                                                  after the pedal is released, the direction icon will
                                                                                  revert to the direction set on the rotary switch.


                                                                         13


The Stryker Endoscopy and Leibinger Handpiece Screen
                                                                                  Depress the mode icon and set the maximum speed
                                                                                  using the adjustment arrows. Speed settings are
                                                                                  individually selected for each mode.

                                                                                  Default speed settings and incremental steps are
                                                                                  specific to each handpiece.


                                                                                  MODES

                                                                                             Operation in high speed mode.



                                                                                             Operation in oscillate mode.



The oscillate mode is selected and Set Speed is set at 1,800 RPM.
                                                                                             Operation in low speed mode.
TPS1, TPS2 and the footswitch icons indicate that other instruments are plugged
into the console.




          WARNING: Read and understand
          the Stryker Endoscopy handpiece
          instructions.
  If instructions were not supplied with your
  handpiece, refer to the appropriate Stryker
  Endoscopy Operating and Maintenance
  Manual listed below.

  Handpiece              Manual
  272-704                1000-400-120
  275-701                1000-400-034
  275-705                1000-400-034
  275-601                1000-400-034
  290-601                1000-400-288

  IMPORTANT INFORMATION
  The hand-controlled Endo Shaver can be
  controlled by the footswitch or by the hand-
  control buttons built into the handpiece.




                                                                          14


Main Option Screen
                          Select the OPT icon to access the MAIN OPTION
                          screen. This screen allows direct access to the
                          handpieces attached to the console, console and user
                          settings, and system information.




                          OPTION 1, 2, and E icons appear only when hand-
                          pieces are plugged into the corresponding console
                          ports. A handpiece must be plugged in to program its
                          settings.


                          To go to the HANDPIECE ADJUSTMENT screen, touch
                          the option button that corresponds to the desired
                          handpiece. Refer to HANDPIECE ADJUSTMENT.


                          The MAIN OPTION screen also gives DIRECT
                          access to:

                                     Refer to SURGEON PREFERENCE.



                                     Refer to CONSOLE ADJUSTMENT.



                                     Refer to SYSTEM INFORMATION.



                                     EXIT: Return to handpiece screen.




                     15


System Information Screen
                            Selecting the INFO icon from the MAIN OPTION menu
                            displays the part numbers and revision levels of the
                            configured system components.

                            This information is used as a diagnostic aid only.


                                        Return to the MAIN OPTION screen.




                      16


                   Handpiece Adjustment Screen




Select a Handpiece Option icon from the MAIN OPTION             ATTACHMENT: Use the arrow icon on the left to scroll
screen to access this screen.                                   through the list of attachments. Select the attachment that
                                                                is assembled to the handpiece by stopping on it.
NOTE: For quick access to this screen, touch the
handpiece title displayed at the top of any handpiece           Selecting the proper attachment will optimize the perfor-
screen. And return to the handpiece screen by                   mance of the handpiece for the attachment and display
touching the handpiece title displayed on this screen.          the appropriate speed scale on the handpiece screen.

Depending on the type of handpiece, one or more of              RUN MODE: Use the RUN MODE toggle button to
the following options will be available.                        scroll through the options and stop on the desired
                                                                setting.
Select BRAKE, ACCEL, TURNS, WATER or AUX then
press the arrow icons to change the setting.                               Variable: Handpiece speed responds to the
                                                                           degree of pressure applied to the handswitch.
          Brake: At 100%, the handpiece stops abruptly.
          Deceleration slows as the setting nears zero.
                                                                           Nonvariable: Handpiece speed runs at the
          Accelerate: At 100%, handpiece speed                             maximum setting only. Varying pressure on
          accelerates quickly. Acceleration slows as the                   the handswitch does not vary the handpiece
          setting approaches zero.                                         speed.

          Turns: Use to set the number of turns per                        One touch: Toggle the handpiece on and off
          direction when running a handpiece in the                        with a single touch of a trigger device. The
          oscillate mode. The minimum setting will set                     trigger device can be the handswitch or
          the oscillate function to operate in a TIME-                     handpiece trigger buttons.
          BASED mode where the number of turns are
          based on the speed of the handpiece.
                                                                           BUTTON: See Handpiece Button Mapping.
          Water: At 100%, irrigation volume is greatest.
          Volume decreases as the setting approaches
          zero.                                                            FOOTSWITCH: Activates FOOTSWITCH
                                                                           ADJUSTMENTS. See Footswitch Adjust-
                                                                           ments.




                                                           17


Console Adjustment Screen
                         Select the CONSOLE ADJUSTMENTS icon from the
                         MAIN OPTION screen to access this screen.

                         Select CONTRAST, BRIGHTNESS or VOLUME then
                         press the arrow icons to change the setting.

                                            Contrast: Screen contrast lightens at
                                            higher settings. The chosen setting
                                            remains until reset.

                                            Brightness: Screen brightness
                                            intensifies at higher settings.

                                            Volume: The audible signal is louder at
                                            higher settings.


                         Use the BIG SCREEN toggle button to select one of
                         the following options.

                                      Automatic: A big screen is displayed while
                                      the handpiece is running and automatically
                                      returns to the full screen when handpiece
                                      stops.

                                      On: The big screen is continuously dis-
                                      played. It can be temporarily switched back
                                      to the full screen by touching the Full Screen
                                      icon which appears in the lower right corner
                                      of each handpiece screen. See example of
                                      screens below.

                                      Off: The big screen option is turned off.
                                      Only a full screen is displayed.




                         Example of full screen.        Example of big screen.




                    18


Footswitch Adjustment Screen
                       This screen appears only when using a TPS Footswitch
                       that is Revision 3 or newer. See Standard Features.

                       NOTE: The Footswitch revision is displayed on the SYSTEM
                       INFORMATION screen.

                       Access this screen by selecting the Footswitch icon on the
                       HANDPIECE CONTROL SCREEN or HANDPIECE ADJUST-
                       MENTS screen.

                       NOTE: These footswitch settings function only for the
                       handpiece for which they were selected. The handpiece is
                       identified at the top of the screen.

                       From this screen, the default functions of footswitch pads A
                       and B can be reprogrammed to accommodate the surgeon's
                       preferences. The left and right toggle icons correspond
                       respectively to footswitch pads A and B. Press each icon to
                       scroll through the following function options and stop on the
                       desired setting.

                                  Off: Pedal is turned off.

                                  Default: Footswitch defaults to the settings
                                  selected on the handpiece screen.

                                  Forward: Pedal setting default is overridden.
                                  Pedal will provide handpiece rotation in the forward
                                  (clockwise) direction.

                                  Reverse: Pedal setting default is overridden.
                                  Pedal will provide handpiece rotation in the reverse
                                  (counterclockwise) direction.


                                  Advanced: Use to access the Footswitch Button
                                  Mapping screen. It will allow you to reprogram all
                                  the footswitch pedals.


                                  Return: Return to the previous screen.




                      19


                    Footswitch Button Mapping Screen
Access this screen by selecting the ADVANCED icon on
the FOOTSWITCH ADJUSTMENTS screen. The default
functions of each footswitch pedal and button can be
reprogrammed to accommodate the surgeon's prefer-
ences.

Depending on the type of handpiece displayed at the top
of the screen, one or more of the following options will be
available on this screen.

The DIRECTION, OP MODE, and RUN MODE icons
correspond respectively to the two largest footswitch
pedals. Press each icon to scroll through the follow-
ing function options. And stop on the desired func-
tion setting.

                       DIRECTION
           Pedal is turned off.
                                                                   BUTTON FUNCTION
           Footswitch defaults to the settings selected on
           the handpiece screen.                                   The I, II, and III icons correspond to the three small pads
                                                                   across the top of the footswitch.
           Forward: Pedal setting default is overridden.
           Pedal will provide handpiece rotation in the            Button Function displays the active function of the
           forward (clockwise) direction.                          corresponding button.

           Reverse: Pedal setting default is overridden.           Use the arrow icons to scroll through the functions and
           Pedal will provide handpiece rotation in the            stop on the desired setting.
           reverse (counterclockwise) direction.
                                                                   See Button Functions listed on next page.
                             OP MODE
           Footswitch defaults to the settings selected on
           the handpiece screen.

           Handpiece operates in the high speed range.

           Handpiece operates in the low speed range.                         Reset all: Press to return all pedals and
                                                                              buttons back to their default setting.
           Handpiece operates in oscillate mode.
                                                                              Reset: Press to return the selected footswitch
                            RUN MODE                                          button back to its default setting.
           Footswitch defaults to the settings selected on
           the handpiece adjust screen.

           Variable: Variable speed control. Speed
           responds to varying degrees of pressure on the
           footswitch.

           Nonvariable: Handpiece operates at a
           constant speed level determined by the
           maximum speed selected from the handpiece
           screen.

           One touch: The one touch function is similar to
           an on/off toggle. Tap the footswitch to operate
           the handpiece at the maximum speed selected
           from the handpiece screen. Tap any trigger
           device again to stop operation.




                                                              20


     Handpiece Button Mapping Screen
                                                                   Access this screen from the Handpiece Adjustment
                                                                   screen. Use it to change handpiece button func-
                                                                   tions.

                                                                   Depending on the features of the handpiece, as
                                                                   many as five buttons can be reprogrammed. Identify
                                                                   corresponding button numbers by pressing the buttons
                                                                   on the handpiece. When the handpiece button is
                                                                   selected, the corresponding function is displayed on the
                                                                   screen. Use the arrow icons to scroll through the
                                                                   function options. Stop on the desired option. See the
                                                                   list below for a description of the options.

                                                                   NOTE: Available options are handpiece specific.

                                                                   BUTTON FUNCTIONS

                                                                               Reset: Select to return a single button to its
                                                                               default function.

                                                                               Reset all: Select to return all buttons to their
                                                                               default functions.

                                                                               Return: Return to previous screen.




                                                 Button Functions List

 Button Function   Description                                   Button Function     Description

    Main trigger   Starts handpiece in default direction         Osc <> High/low     Toggles the run mode between oscillate
                   and mode.                                                         and high or low.

    FWD trigger    Starts handpiece in forward                       High <> Low     Toggles the run mode between high and
                   direction in default mode.                                        low.

     REV trigger   Starts handpiece in reverse                  Forward <> Reverse Toggles the running direction.
                   direction in default mode.
                                                                     Change port     Changes the active handpiece port.
     OSC trigger   Starts handpiece in oscillate mode.
                                                                Change attachment Scrolls through the attachment list for the
Speed increment    Increments the set point speed.                                selected handpiece.

Speed decrement    Decrements the set point speed.                    Pump flush     Turns the pump on at the flush rate. Once
                                                                                     started the pump can be stopped by
Water increment    Increments the pump flow set point.                               pressing the button again or by starting
                                                                                     the handpiece.
Water decrement    Decrements the pump flow set
                   point.                                        Make port active    Makes the selected handpiece active.

    Water on/off   Toggles the pump on/off button. If
                   pressed and held, the pump can be
                   turned on without running the
                   handpiece. Once started, the pump
                   can be stopped by pressing the
                   button again or by starting the
                   handpiece.




                                                           21


Surgeon Preference Screen
                                            Access the SURGEON PREFERENCE screen from the MAIN
                                            OPTIONS screen.

                                            The console is able to capture and store the preferred settings of
                                            different surgeon's.

                                            There are three options:
                                            • Factory default settings
                                            • Settings saved by a previous surgeon
                                            • Collection and storage of new settings

                                            Using factory settings
                                            1. Use the arrows to obtain "Stryker" and "Factory Default."

                                            NOTE: The EDIT, DELETE and padlock icons do not function
                                            while factory default settings are selected.

                                            Using the settings saved by a previous user
                                            1. Use the arrows to select the surgeon and procedure.
                                            2. Select LOAD. Screen returns to the MAIN OPTION screen.
                                            3. Proceed with surgery.

                                            Collect and store preferred settings
                                            1. Select NEW. The editor screen will appear with the selected
                                               surgeon's name.
                                            2. To create a new procedure under this surgeons name, select
                                               ENTER. Or if you wish to collect and store settings under a
       This is the key pad screen used to      new surgeon name, use the key pad to delete (DEL) the
       enter the doctor's name and name        existing name then key-in the new name. Upon completion,
       of procedure.                           select ENTER.
                                            3. Use the key pad to enter the procedure name.
                                            4. Upon completion, select ENTER. The screen returns to the
                                               SURGEON PREFERENCE screen.
                                            5. Toggle padlock icon so that the padlock appears open.
                                            6. Select LOAD.
                                            7. Configure system settings.
                                            8. Upon completion, return to the SURGEON PREFERENCE
                                               screen.
                                            9. Toggle the padlock icon so that the padlock appears locked.

                                            NOTE: If the padlock icon remains in the unlocked position, the
Padlock opened to gather preferences.       selected settings will be continuously updated with current
                                            settings.

Padlock closed to store preferences.                   Select to add a surgeon name.

                                                       Select to change the doctor name and/or procedure.

                                                       NOTE: Toggle the UPPER/LOWERCASE pad on the
                                                       editor screen to select letter case.

                                                       Delete: Select to delete the currently displayed file.


                                                       Select and use with the open padlock to gather (load)
                                                       new preference settings.

                                                       Default: Using the arrows, scroll the SURGEON
                                                       PREFERENCE screen to the desired surgeon and
                                                       procedure settings before activating DEFLT. This
                                                       selection becomes the default power on setting for the
                                                       system until a different selection is made.


                                               22


Messages
Message                                                      If you select OK to this question:

Delete all the surgeon's procedures?                         The surgeon ID and all procedures will be deleted.

Change the name of all the surgeon's                         Procedures listed under the surgeon will be moved under
procedures?                                                  the current surgeon's name.

Identical record found.

Maximum number of records exceeded. Please delete inactive records.

Initializing console hardware. Please wait.

Handpiece has reached recommended service interval. Please return for service at earliest convenience.

Handpiece does not support the selected preference. Default handpiece setting will be used.

Handpiece temperature has exceeded its nominal operating range and may cause burning.

Handpiece temperature has exceeded its operating range. Allow to cool before restarting.

Procedure name unspecified.

Ensure handpiece speed does not exceed specified attachment limitations. Failure to do so may result in user and/or patient
injury.




Error Messages
Message                                                                         Action to Take
Error 001.   Console hardware fault detected.                                   Return console to Stryker for repair.

Error 002.   Console hardware fault detected.                                   Turn unit off and on again. If problem persists, return
             Contact your Stryker service representative.                       console to Stryker for repair.

Error 003.   Console hardware fault detected.                                   Turn console off and on again. If problem persists, return
             Contact your Stryker service representative.                       console to Stryker for repair.

Error 004.   Footswitch fault detected, right pedal will be disabled.           Unplug Footswitch from console and plug in again.
             Contact your Stryker service representative.                       If problem persists, return footswitch to Stryker for repair.

Error 005.   Footswitch fault detected, left pedal will be disabled.            Unplug Footswitch from console and plug in again.
             Contact your Stryker service representative.                       If problem persists return footswitch to Stryker for repair.

Error 006.   Footswitch unreadable.                                             Unplug Footswitch from console and
             Contact your Stryker service representative.                       plug in again. If problem persists,
                                                                                return footswitch to Stryker for repair.

Error 007.   Handpiece fault detected, handpiece triggers will be               Unplug cord from handpiece and plug in again.
             disabled. Contact your Stryker service representative.             If problem persists, return handpiece to Stryker for repair.

Error 008.   Handpiece unreadable.                                              Unplug handpiece from console and plug in again.
             Contact your Stryker service representative.                       If problem persists, return handpiece Stryker for repair.

Error 009.   Handpiece requires additional console hardware.                    Call your Stryker Instruments sales representative.
             Contact your Stryker service representative.

Error 010    Handpiece requires additional console hardware.                    Call your Stryker Instruments sales representative.
             Contact your Stryker service representative.

Error 011    Handpiece requires additional console hardware.                    Call your Stryker Instruments sales representative.
             Contact your Stryker service representative.

The Total Performance System is not field repairable. In case of operating difficulties, Stryker products must be returned for maintenance
or repair.




                                                                   23


Specifications
 Models: 5100-1 TPS Console
                                                                                                    Class I
         5100-50 TPS Irrigation Console
                                                                                                      PORT       TYPE     SYMBOL
 Size:     11.8 in. [299 mm] width
           7.0 in. [179 mm] height                                                                    Endo         B
           9.0 in. [229 mm] depth
           12.2 in. [310 mm] depth (units with irrigation pump)                                       TPS1        BF

 Weight: 9 lbs. [4.1 Kg]                                                                              TPS2        BF
         14.1 lbs. [6.4 Kg] (units with irrigation pump)


 Models: 5100-201 TPS Hermes READY™ Console                                                         IPX0 Ordinary Equipment
         5100-250 TPS Hermes READY™ Irrigation Console
                                                                                                    Protective Earth Ground
 Size:     11.8 in. [299 mm] width
           7.0 in. [179 mm] height                                                                  Duty Cycle: Continuous operation with
           9.4 in. [240 mm] depth                                                                               intermittent loading
           12.7 in. [322 mm] depth (units with irrigation pump)                                                 Refer to cycle times defined in
                                                                                                                the TPS handpiece instruc-
 Weight: 9 lbs. [4.1 Kg]                                                                                        tions.
         14.1 lbs. [6.4 Kg] (units with irrigation pump)


  Electrical:   100-120VAC, 50-60Hz 6.0A

  Approval:
                CSA International
                • UL 2601-1
                • CAN/CSA-C22.2 No. 601.1 M90
                • IEC 60601-1


Handling your console and equipment                                          Environmental Conditions
• When setting up your console, place on a sturdy, flat surface,             These conditions apply to all components of the TPS system
  and carefully follow all setup instructions.                               unless otherwise specified in the information supplied with
                                                                             that device.
• When connecting or disconnecting a cable, always hold the
  cable by its connector (the plug, not the cord).
                                                                               Environmental Conditions:      Operation   Storage and Transportation

• Never force a connector into a port. If the connector and port
  do not join with reasonable ease, they probably don't match.                 Temperature:

  Make sure that the connector matches the port and that you
  have positioned the connector correctly in relation to the port.
                                                                               Relative humidity:

• To ensure the longevity, performance, and safety of this
  equipment, package in original package materials when storing
  or transporting.
                                                                               Atmospheric Pressure:

If the console experiences sporadic electrical interference:

• Turn off all electrical equipment not in use in the operating room.

• Relocate electrical equipment; increase spacial distance.
                                                                             Specifications listed are approximate and may vary slightly from
• Plug the TPS console and other operating room equipment into               unit to unit or by power supply fluctuations.
  different outlets.


Federal Communications Commission
Compliance Statement (US only.)                                                                                               FCC ID: Q9R-5100
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation.
Note that FCC regulations provide that changes or modifications not expressly approved by Stryker
Instruments could void your authority to operate this equipment.

                                                                        24


Repair and Loaner Program

This service is available in the United States only. Outside the U.S.A., contact your Stryker sales
representative or your nearest subsidiary listed on the last page.

On request, Stryker Instruments will provide a loaner unit for your use while repairs are
being made.
Please clean and sterilize all potentially contaminated products being sent in for repair,
credit, or return of a loaner unit. The policy of Stryker Instruments is not to accept or
process potentially contaminated products which do not meet this requirement.

Also, please be aware that it is unlawful to transport bio-contaminated products through
interstate commerce which are not properly packaged and labeled as such.

1. Contact Stryker Customer Service at 1-800-253-3210 to request a loaner. Provide a
   name and address for shipping. Every effort will be made to send a loaner unit immediately.

2. Send the inoperative unit to Stryker with a purchase order number of authorization for
   repair. The order should explain the nature of the difficulty. Also, provide a name and
   address for shipping the repaired instruments.

   Return the inoperative unit to:         Stryker Instruments
                                           Repair Department
                                           4100 E. Milham
                                           Kalamazoo, Michigan, 49001.

3. The repaired unit will be shipped back and the repair invoice will follow under separate
   cover. Under most conditions, repair turnaround time will be approximately 2-3 weeks.

4. As soon as your repaired unit is returned, return the loaner to Stryker Instruments.




Limited Warranty
For all TPS products unless otherwise specified.
In the U.S.A. only, products of Stryker Instruments are warranted to the original purchaser for a period of one
year from the date of purchase, with exceptions noted below. Products are warranted to be free from defects in
material and workmanship. Abnormal wear and tear or damage caused by misuse or by failure to perform
normal and routine maintenance as set out in the Maintenance Manual or Operating Instructions, or as demon-
strated by an authorized Stryker Instruments representative, is not covered by the warranty. Any effort at field
repair or adjustment may invalidate your warranty.

The warranty extends to all purchasers and is limited to the repair or replacement of the product without charge
when returned prepaid to Stryker Instruments. There are no other expressed warranties. This warranty gives
you specific legal rights and you may have other rights which vary by state and municipality.

For selected products.
• Universal Handswitch is warranted for a period of 6 months from date of invoice.
• Handpiece cords are warranted for a period of 6 months from date of invoice.
• Cutting accessories are not warranted.




                                                                    25


 Stryker International Subsidiaries

Stryker SA                                 Phone: 41-21-963-87-01         Stryker Far East Inc., Singapore        Phone: 65-287-8851
European Headquarters                        Fax: 41-21-963-87-00         Block 204, #04-103                             65-287-8353
Cite-Centre, Grand-Rue 92                                                 Hougang Street 21                         Fax: 65-382-3920
CH-1820 Montreux, Switzerland                                             Singapore 1953

Stryker BV                                  Phone: 31-40-292-2522         Stryker Far East Inc., Taiwan        Phone: 886-2-2322-2895
Postbus 8747                                  Fax: 31-40-292-2555         5F-1, 23 Pa-Te Road                    Fax: 886-2-2357-8543
5605 LS Eindhoven                                                         Section 1, Taipei, Taiwan ROC
The Netherlands
                                                                          Stryker Korea                          Phone: 82-2-565-7303
Stryker Corp.- U.K.Branch                  Phone: 44-163-52-62400         11F, Dongsung B/D, 158-24                Fax: 82-2-552-4156
Medway House                                 Fax: 44-163-55-80300         Samsung-dong, Kangman-ku,
5000 Newbury Business Park                                                Seoul 135-090, Korea
London Road, Newbury
Berkshire, U.K. RG14 2ST                                                  Stryker Malaysia                       Phone: 603-715-3650
                                                                          No 55, Lorung Rahim Kajai 13             Fax: 603-715-5228
Stryker Deutschland GmbH                     Phone: 49-20899-9060         Taman Tun Dr. Ismail
Gewerbeallee 18                               Fax: 49-208999-0666         6000 Kuala Lumpur, Malaysia
D-45478 Mulheim an der Ruhr
Germany                                                                   Stryker Singapore Ltd.                  Phone: 65-293-0119
                                                                          70 Bendemeer Road                         Fax: 65-293-7028
Stryker Polska Sp. Zo.o                    Phone: 48-22-631-20-13         #03-02 Hiap Juat House
ul. Kolejowa 10/21                           Fax: 48-22-631-20-15         Singapore 339940
01-217 Warsawa, Poland
                                                                          Stryker Middle East-Africa             Phone: 971-2-312-145
Stryker Finland                             Phone: 358-9-477-3400         PO Box 26589                             Fax: 971-2-313-698
Nuijamiestentie 5B,                        Fax: 011-358-9-477-3344        Abu Dhabi, UAE
Fin-00400
Helsinki, Finland                                                         Nippon Stryker K.K.                   Phone: 81-6-6203-2060
                                                                          4-7 Awajimachi Nichome, Chuo-ku         Fax: 81-6-6202-3548
Stryker France SARL                        Phone: 33-1-48-17-50-00        Osaka 541-0047, Japan
BP 50040-95946 Roissy CDG                      Fax: 33-1-48632175
France                                                                    Stryker Korea Limited                  Phone: 82-2-718-2972
                                                                          Room 1407, Guhsung Bldg.                 Fax: 82-2-718-2974
Dimso Iberica SA                              Phone: 34-1323-1731         541, Dohwa-Dong, Mapo-Ku
Calle Puente Cesures                            Fax: 34-1315-2782         Seoul, Korea
1 Bajos 28020 Madrid
                                                                          Stryker Americas-Middle East           Phone: 269-385-2600
Stryker Portugal, Produtos Medicos, Lda.    Phone: 351-1-839 49 10        2725 Fairfield Road                           800-726-2725
Avenida Marechal Gomes da Costa, 35           Fax: 351-1-839 49 19        Kalamazoo, Michigan 49002 USA            Fax: 269-385-1062
1 800-255 Lisbon Portugal                                                 Mailing Address:
                                                                          P.O. Box 4085
Stryker Italy SrL                             Phone: 39-06-330541         Kalamazoo, Michigan 49003-4085 USA
Via Ghisalba, 158                             Fax: 39-06-33625826
00188 Rome                                                                Stryker Chile SRL                       Phone:562-244-3600
Italy                                                                     Avenida Nueve Tajamar 481                 Fax: 562-244-3696
                                                                          Torre Norte
                                                                          Piso 8 Oficina 805
Stryker South Africa                        Phone: 27-11-888-4841         Santiago, Chile
195 DF Malan Drive                            Fax: 27-11-782-4080
2195 Northcliff                                                           Stryker Latin America                  Phone: 305-821-1888
Johannesburg, South Africa                                                Plaza Royale, Suite 304                  Fax: 305-826-0067
                                                                          15600 NW 67th Ave
Stryker C.I.S.                              Phone: 7-095-917 3484         Miami Lakes, FL 33014
Pokerovka Str 42/5                             Fax: 7-095-97 3484
3rd Floor                                                                 Stryker Mexico, S.A. de C.V.           Phone: 525-488-0890
103062 Moscow, Russia                                                     Montecito No. 38 Piso 12                 Fax: 525-488-0891
                                                                          Oficina 31, Col. Napoles
Stryker China, Limited                        Phone: 852-814-7463         Mexico D.F. 03810
10/F., Sungib Industrial Centre                FAX: 852-873-0210
53 Wong Chuk Hang Road                                                    Stryker Canada - Toronto               Phone: 905-332-3235
Aberdeen, Hong Kong                                                       3375 North Service Road                  Fax: 905-332-7674
                                                                          Unit C-9
Stryker Australia Pty. Ltd.                 Phone: 61-29-439-5100         Burlington, Ontario
Unit 20/39 Herbert St.                        Fax: 61-29-439-6400         Canada L7N3G2
St. Leonards NSW 2065
PO Box 50                                                                 Stryker Canada - Montreal              Phone: 514-685-4024
Australia                                                                 72 3rd Avenue North                      Fax: 514-685-4024
                                                                          Roxboro, Quebec
Stryker Beijing Liaison Office               Phone: 86-1-831-3388         Canada H8Y 2L9
Room 2037, Xiyuan Hotel                           Extension: 2037
Beijing, China                                 Fax: 86-1-831-4577
                                                  Extension: 2037

Stryker Far East Inc., India               Phone: 91-11-686-25677
1st floor 94 Uday Park                        Fax: 91-11-651-5496
New Delhi 110 049 India




                                                                     26


27


4100 E. Milham
Kalamazoo, Michigan
(USA) 49001
1-800-253-321
1-269-323-7700




        28



Document Created: 2003-07-07 15:01:35