Q9DMST200_Class II report

FCC ID: Q9DMST200

Test Report

Download: PDF
FCCID_1903900

                                                                   FCC ID: Q9DMST200




        EMC TEST REPORT for Class II permissive change
                              No. SH12120553-002

               Applicant           : Aruba Networks, Inc.
                                    1344 Crossman Ave. Sunnyvale California 95089
                                    United States
               Manufacturer        : Aruba Networks, Inc.
                                    1344 Crossman Ave. Sunnyvale California 95089
                                    United States

               Product Name        : Outdoor Wireless Mesh Access Router

            Type/Model             : MST2H13N1-XX(where –
                                     XX can be any alphanumeric or blank)




SUMMARY
The equipment complies with the requirements according to the following standard(s):

47CFR Part 15 (2010): Radio Frequency Devices

ANSI C63.4 (2003): American National Standard for Methods of Measurement
of Radio-Noise Emissions from Low-Voltage Electrical and Electronic
Equipment in the Range of 9 kHz to 40 GHz



Date of issue: Jan 13, 2013


Prepared by:                                           Reviewed by:




Wakeyou Wang (Project Engineer)                        Daniel Zhao (Reviewer)




                                        Page 1 of 15


                                                              FCC ID: Q9DMST200


Description of Test Facility
Name:        Intertek Testing Services Limited Shanghai
Address:     Building No.86, 1198 Qinzhou Road(North), Shanghai 200233, P.R. China

FCC Registration Number: 236597
IC Assigned Code: 2042B-1


Name of contact: Steve Li
Tel: +86 21 64956565 ext. 214
Fax: +86 21 54262335 ext. 214




                                     Page 2 of 15


                                                                                                                        FCC ID: Q9DMST200


                                                                       Content

SUMMARY.......................................................................................................................................................... 1
DESCRIPTION OF TEST FACILITY ......................................................................................................................... 2
1.  GENERAL INFORMATION ............................................................................................................................ 4
     1.1 Applicant Information ..................................................................................................... 4
     1.2 Identification of the EUT ................................................................................................ 4
     1.3 Technical specification ................................................................................................... 5
     1.4 Mode of operation during the test / Test peripherals used .............................................. 6
2.      TEST SPECIFICATION .................................................................................................................................. 7
     2.1 Instrument list ................................................................................................................. 7
     2.2 Test Standard .................................................................................................................. 7
     2.3 Test Summary ................................................................................................................. 8
3.      RADIATED EMISSION ................................................................................................................................... 9
     3.1 Test limit ......................................................................................................................... 9
     3.2 Test Configuration .......................................................................................................... 9
     3.3 Test procedure and test setup ........................................................................................ 10
     3.4 Test protocol ................................................................................................................. 11
4.      POWER LINE CONDUCTED EMISSION ........................................................................................................ 13
     4.1 Limit .............................................................................................................................. 13
     4.2 Test configuration ......................................................................................................... 13
     4.3 Test procedure and test set up ....................................................................................... 14
     4.4 Test protocol ................................................................................................................. 15




                                                                        Page 3 of 15


                                                               FCC ID: Q9DMST200


1. General Information

1.1 Applicant Information

Applicant:                      Aruba Networks, Inc.
                                1344 Crossman Ave. Sunnyvale California 95089
                                United States

Name of contact:                Ivaylo Tankov
Tel:                            408-754-3035
Fax:                            408-227-4550
Manufacturer:                   Aruba Networks, Inc.
                                1344 Crossman Ave. Sunnyvale California 95089
                                United States
Sample received date        :    Dec 10, 2012
Sample Identification No    :    *0121210-17-001*
Date of test                :    Dec 10, 2012 ~ Dec 30, 2012



1.2 Identification of the EUT

Equipment:                      Outdoor Wireless Mesh Access Router
Type/model:                     MST2H13N1-XX(where –
                                XX can be any alphanumeric or blank)
FCC ID:                         Q9DMST200




                                    Page 4 of 15


                                                               FCC ID: Q9DMST200


1.3 Technical specification

Operation Frequency Band:     5745 – 5825 MHz, 5755 – 5795MHz
Modulation:                    DBPSK @1Mbps
                               DQPSK@2Mbp
                               CCK@5.5/11Mbps
                               BPSK@6/9 Mbps
                               QPSK@12/18Mbps
                               16-QAM@24Mbps
                               64-QAM@48/54Mpb and above
Gain of Antenna:               Internal, 13dBi
Rating:                       100-240Va.c., 0.5A, 50/60Hz
Description of EUT:           Here are a series of models. They are electrically
                              identical except for different model names.
                              The EUT supports wireless network of
                              802.11a/n.
                              The RF module used contains of two chains,
                               namely chain 1 and chain 2.

Port identification:
                                 Port        Description         Type          Number

                                   1              Console      USB2.0              1

                                   4              Ethernet       RJ45              1

Dimension:                    26cm * 18cm *8cm
Declared Temperature range:   -30C ~ 60C
Channel Description:
                                HT 20        Frequency        HT 40         Frequency
                               Channel            (MHz)      Channel         (MHz)
                                 149              5745         151            5755
                                 153              5765         159            5795
                                 157              5785
                                 161              5805                  /
                                 165              5825




                                   Page 5 of 15


                                                                     FCC ID: Q9DMST200


1.4 Mode of operation during the test / Test peripherals used

While testing transmitting mode of EUT, the internal modulation and continuously
transmission was applied.
The power level setting for 802.11a/b/g/n is “11.0” indicated in software offered by the
manufactory.




Test peripherals used:
   Item No    Description                Band and Model                     S/No
       1      Laptop computer            FUJITSU SIMENS, LIFEBOOK NA




The lowest, middle and highest channel were tested as representatives.
For 802.11a----- lowest, 5745MHz; middle, 5785MHz; highest, 5825MHz.
For 802.11n HT20 ----- lowest, 5745MHz; middle, 5785MHz; highest, 5825MHz.
For 802.11n HT40 ----- lowest, 5755MHz; highest, 5795MHz.
   .




                                         Page 6 of 15


                                                                     FCC ID: Q9DMST200


2. Test Specification

2.1 Instrument list
    Equipment            Type         Manu.           Internal no.    Cal. Date     Due date
  Test Receiver         ESIB 26        R&S             EC 3045       2012-10-21   2013-10-20
  Semi-anechoic            -         Albatross         EC 3048       2012-5-21     2013-5-20
     chamber                          project
  Bilog Antenna        CBL 6112D      TESEQ           EC 4206        2011-5-16    2013-5-15
   Horn antenna           HF 906       R&S            EC 3049        2011-5-13    2013-5-12
   Pre-amplifier       Pre-amp 18      R&S            EC 3222        2013-4-12    2013-4-11
  Test Receiver          ESCS 30       R&S            EC 2107        2012-10-21   2013-10-20
      A.M.N.            ESH2-Z5        R&S            EC 3119         2012-1-9     2013-1-8
      A.M.N.            ESH3-Z5        R&S            EC 2109        2012-1-10     2013-1-9
 High Pass Filter        WHKX        Wainwright       EC4297-1        2012-2-8     2013-2-7
                      1.0/15G-10SS
 High Pass Filter        WHKX        Wainwright       EC4297-2        2012-2-8     2013-2-7
                      2.8/18G-12SS
 High Pass Filter        WHKX        Wainwright       EC4297-3        2012-2-8     2013-2-7
                      7.0/1.8G-8SS
Band Reject Filter      WRCGV        Wainwright       EC4297-4        2012-2-8     2013-2-7
                       2400/2483-
                       2390/2493-
                         35/10SS
  Test Receiver           FSV40         R&S               /          2012-10-21   2013-10-20
  Preamplifier          AP-025C        Quietek        QT-AP003       2012-11-25   2013-11-24
  Preamplifier          AP-180C        Quietek          CHM-         2012-11-25   2013-11-24
                                                       0602013
Broad-Band Horn       BBHA9120D      Schwarzbeck         496         2012-11-25   2013-11-24
    Antenna
Broad-Band Horn        BBHA9170      Schwarzbeck          294        2012-11-25   2013-11-24
    Antenna



2.2 Test Standard

47CFR Part 15 (2010)
ANSIC63.4 (2003)




                                       Page 7 of 15


                                                               FCC ID: Q9DMST200


2.3 Test Summary

This report applies to tested sample only. This report shall not be reproduced in part
without written approval of Intertek Testing Service Shanghai Limited.

          TEST ITEM             FCC REFERANCE         IC REFERANCE         RESULT
Radiated emission                15.205 & 15.209            -                Pass
Power line conducted emission         15.207                -                Pass




                                     Page 8 of 15


                                                                      FCC ID: Q9DMST200


3. Radiated emission

   Test result:       PASS

3.1 Test limit

The radiated emissions which fall in the restricted bands, as defined in §15.205(a), must also
comply with the radiated emission limits specified in §15.209(a) showed as below:

Frequency          Field Strength     Measurement Distance
(MHz)               (dBuV/m)                (m)
___________________________________________________________
30 - 88               40.0                   3
88 - 216              43.5                   3
216 - 960             46.0                   3
Above 960              54.0                  3
________________________________________________________________




3.2 Test Configuration




                                                                         EUT

           Antenna mast
                                                                        Turn Table




                            Test receiver




                                            Page 9 of 15


                                                                     FCC ID: Q9DMST200



3.3 Test procedure and test setup

The measurement was applied in a semi-anechoic chamber. While testing for spurious
emission higher than 1GHz, if applied, the pre-amplifier would be equipped just at the output
terminal of the antenna.
The EUT and simulators were placed on a 0.8m high wooden turntable above the horizontal
metal ground plane. The turn table rotated 360 degrees to determine the position of the
maximum emission level. The EUT was set 3 meters away from the receiving antenna which
was mounted on an antenna mast. The antenna moved up and down between from 1meter to
4 meters to find out the maximum emission level.
The EUT was tested according to DTS test procedure of KDB558074 D01 DTS “Meas
Guidance v02” for compliance to FCC 47CFR 15.247 requirements.

The radiated emission was measured using the Spectrum Analyzer with the resolutions
bandwidth set as:
RBW = 100kHz, VBW = 300kHz (30MHz-1GHz)
RBW = 1MHz, VBW = 3MHz (>1GHz for PK);
RBW = 1MHz, VBW = 10Hz (>1GHz for AV);




                                        Page 10 of 15


                                                               FCC ID: Q9DMST200


3.4 Test protocol

Dual chain, 11na, HT20 mode (which mode with max. output power):
CH    Polarization Frequency Correct       Corrected      Limit      Margin Detector
                     (MHz)   Factor         Reading     (dBuV/m)      (dB)
                             (dB/m)        (dBuV/m)
           V         5747.29     33.60       117.10    Fundamental     /       PK
           V          131.08     15.10        41.00       43.50       2.50     PK
           H          340.02     16.60        43.50       46.00       2.50     PK
           H          749.23     22.90        35.70       46.00      10.30     PK
 L
           V         1000.00     24.60        35.30       54.00      18.70     PK
           V         5460.00      0.10        43.20       54.00      10.80     PK
           V         11466.03    12.90        61.20       74.00      12.80     PK
           V         11465.92    12.90        51.50       54.00       2.50     AV
           V         5780.86     33.60       117.30    Fundamental     /       PK
           V          131.08     15.10        41.00       43.50       2.50     PK
           H          340.02     16.60        43.50       46.00       2.50     PK
           H          749.23     22.90        35.70       46.00      10.30     PK
 M
           V         1000.00     24.60        35.30       54.00      18.70     PK
           V         5460.00      0.10        43.60       54.00      10.40     PK
           V         11565.67    13.30        60.50       74.00      13.50     PK
           V         11565.53    13.30        50.90       54.00       3.10     AV
           V         5828.33     33.60       117.80    Fundamental     /       PK
           V          131.08     15.10        41.00       43.50       2.50     PK
           H          340.02     16.60        43.50       46.00       2.50     PK
           H          749.23     22.90        35.70       46.00      10.30     PK
 H
           V         1000.00     24.60        35.30       54.00      18.70     PK
           V         5460.00      0.10        43.20       54.00      10.80     PK
           V         11648.71    13.70        60.10       74.00      13.90     PK
           V         11648.60    13.70        51.00       54.00       3.00     AV




                                     Page 11 of 15


                                                                  FCC ID: Q9DMST200


Remark: 1. Correct Factor = Antenna Factor + Cable Loss (-Amplifier, is employed)
       2. Corrected Reading = Original Receiver Reading + Correct Factor
       3. Margin = limit – Corrected Reading
       4. If the PK reading is lower than AV limit, the AV test can be elided.


Example: Assuming Antenna Factor = 30.20dB/m, Cable Loss = 2.00dB,
         Gain of Preamplifier = 32.00dB, Original Receiver Reading = 10dBuV.
         Then Correct Factor = 30.20 + 2.00 – 32.00 = 0.20dB/m; Corrected Reading =
         10dBuV + 0.20dB/m = 10.20dBuV/m
         Assuming limit = 54dBuV/m, Corrected Reading = 10.20dBuV/m, then Margin =
          54 -10.20 = 43.80dBuV/m




                                       Page 12 of 15


                                                                     FCC ID: Q9DMST200


4. Power line conducted emission

   Test result:           Pass


4.1 Limit

                                                Conducted Limit (dBuV)
   Frequency of Emission (MHz)
                                                QP                      AV

             0.15-0.5                      66 to 56*                 56 to 46 *
                  0.5-5                         56                       46
                  5-30                          60                       50
  * Decreases with the logarithm of the frequency.




4.2 Test configuration




                                         EUT
                      Peripheral
                       devices




                          LISN           LISN                     EMI receiver




   For table top equipment, wooden support is 0.8m height table

   For floor standing equipment, wooden support is 0.1m height rack.




                                       Page 13 of 15


                                                                   FCC ID: Q9DMST200


4.3 Test procedure and test set up

The EUT are connected to the main power through a line impedance stabilization network
(LISN). This provides a 50Ω/50uH coupling impedance for the measuring equipment. The
peripheral devices are also connected to the main power through a LISN that provides a
50Ω/50uH coupling impedance with 50Ω termination.
Both sides (Line and Neutral) of AC line are checked for maximum conducted interference.
In order to find the maximum emission, the relative positions of equipment and all of the
interface cables must be changed according to ANSI C63.4 on conducted measurement.
The bandwidth of the test receiver is set at 9 kHz.




                                       Page 14 of 15


                                                                 FCC ID: Q9DMST200


4.4 Test protocol




   Frequency   Correct Factor   Corrected Reading        Limit               Margin
                   (dB)              (dBuV)             (dBuV)                 (dB)
                                   QP      AV          QP    AV             QP      AV
    0.47 (N)        3.00         38.88       38.60    56.52   46.52    17.64       7.92

    0.75 (N)        3.00         36.94       35.56    56.00   46.00    19.06      10.44

    0.84 (N)        3.00         35.80       34.36    56.00   46.00    20.20      11.64

    0.94 (L)        3.00         32.90       30.75    56.00   46.00    23.10      15.25

    1.87 (L)        3.00         31.46       24.80    56.00   46.00    24.54      21.20

    2.90 (N)        3.00         26.95       14.47    56.00   46.00    29.05      31.53
  Remark: 1. Correction Factor (dB) = LISN Factor (dB) + Cable Loss (dB).
          2. Margin (dB) = Limit - Corrected Reading.




                                      Page 15 of 15



Document Created: 2013-01-30 15:08:53
Document Modified: 2013-01-30 15:08:53

© 2025 FCC.report