Q9DMST200_MPE

FCC ID: Q9DMST200

RF Exposure Info

Download: PDF
FCCID_1697671

                                                                     FCC ID: Q9DMST200
                                                                       IC: 4675A- MST200

                     Statement of compliance to
                Maximum Permissible Exposure (MPE)

               Applicant           : Aruba Networks, Inc.
                                    1322 Crossman Ave., Sunnyvale CA 94089 USA

            Type/Model             : MST2H23N0-XX(where –
                                     XX can be any alphanumeric or blank)


According to §2.1091, §2.1093 and §1.1307(b), systems operating under the provisions of
this section shall be operated in a manner that ensures that the public is not exposed to
radio frequency energy level in excess of the Commission’s guidelines.


The S = PG / (4πR²)
Where S = power density in mW/cm²
       P = transmit power in mW
       G = numeric gain of transmit antenna
       R = distance (cm)

As we can see from the test reports SH12020037-001 and SH12020037-002:

The maximum P = 20.63Bm = 115.611mW
The gain of antenna G = 13dBi = 19.953
R is chosen to be 20cm,
S = PG / (4πR²) =115.611 * 19.953 / (4 * 3.14 * 20 * 20) = 0.46mW/cm²


This level is below the 1 mW/cm² MPE for General Population / Uncontrolled Exposure as
stated in OET BULLETIN 65 Edition 97-01.



Date of issue: Sep 16, 2012

Prepared by:                                          Reviewed by:




Wakeyou Wang (Project Engineer)                       Daniel Zhao (Reviewer)



                                        Page 1 of 2


                                                                    FCC ID: Q9DMST200
                                                                      IC: 4675A- MST200


                                      Appendix I
Definition below must be outlined in the User Manual:

To satisfy FCC RF exposure requirements, a separation distance of 20 cm or more should be
maintained between the antenna of this device and persons during device operation.
To ensure compliance, operations at closer than this distance is not recommended.




                                         Page 2 of 2



Document Created: 2012-05-02 10:25:34
Document Modified: 2012-05-02 10:25:34

© 2024 FCC.report