MPE Test report

FCC ID: Q9DASIN0301

RF Exposure Info

Download: PDF
FCCID_4476336

MPE/RF EXPOSURE TEST REPORT
FCC CFR 47 Part 1.1310

REPORT No:. HPEN141-U12_MPE Rev A




                     Company: Hewlett Packard Enterprise

                            Model No:. ASIN0301


MPE/RF EXPOSURE TEST REPORT

        Company: Hewlett Packard Enterprise

                    Model: ASIN0301

             To: FCC CFR 47 Part 1.1310

 Test Report Serial No.: HPEN141-U12_MPE Rev A

             This report supersedes: NONE



                  Applicant:     Hewlett Packard Enterprise
                                 3333 Scott Blvd.
                                 Santa Clara, California 95054
                                 USA



                 Issue Date:     3rd September 2019




This Test Report is Issued Under the Authority of:

   MiCOM Labs, Inc.
   575 Boulder Court
   Pleasanton California 94566
   USA
   Phone: +1 (925) 462-0304
   Fax: +1 (925) 462-0306
   www.micomlabs.com

 MiCOM Labs is an ISO 17025 Accredited Testing Laboratory


                                                     Title:     Hewlett Packard Enterprise, Aruba User Experience Insight
                                                       To:      FCC CFR 47 Part 1.1310
                                                  Serial #:     HPEN141-U12_MPE Rev A




1. MAXIMUM PERMISSABLE EXPOSURE
Calculations for Maximum Permissible Exposure Levels
Power Density = Pd (mW/cm2) = EIRP/(4*π*d2)
EIRP = P * G
P = Peak output power (mW)
G = Antenna numeric gain (numeric)
d = Separation distance (cm)
Numeric Gain = 10 ^ (G (dBi)/10)

The calculations in the table below use the highest conducted power values together with the lowest antenna
gain specified for the EUT. These calculations represent worst case in terms of the exposure levels.
                                                                                                                                 Calculated
                                                                                  Calculated                          Min
                                                        Peak         Peak                          Power                           Power
                             Ant       Numeric                                      Power                         Calculated
                                                       Output       Output                        Density                         Density
   Freq. Band (MHz)         Gain        Gain                                       Density                            safe
                                                       Power        Power                          Limit                         (mW/cm2)
                            (dBi)     (numeric)                                   (mW/cm2)                        distance for
                                                       (dBm)        (mW)                         (mW/cm2)                          @ Safe
                                                                                   @ 20cm                          Limit (cm)
                                                                                                                                  Distance
    5150.0 - 5250.0          4.90        3.09          20.55         134.00          0.08           1.00              5.7            1.00
    5470.0 - 5725.0          4.90        3.09          21.19         131.77          0.08           1.00              5.7            1.00
    5725.0 - 5850.0          4.90        3.09          21.18         131.26          0.08           1.00              5.8            1.00
    5250.0 - 5350.0          4.90        3.09          20.72         118.03          0.07           1.00              4.8            1.00
 2400.0 - 2483.5 (Wi-Fi)     2.00        1.58          21.41         138.21          0.04           1.00              4.2            1.00
 2400.0 - 2483.5 (BLE)       1.80        1.51           3.06          2.00           0.001          1.00              0.5            1.00


Assessment for simultaneous operation:
Only the BLE and highest Power Density used for simultaneous operation.
                                                        Peak         Peak           Power
                            Ant        Numeric
                                                       Output       Output       Density Limit      Power Density
  Freq. Band (MHz)         Gain         Gain                                                                                     Ei/Eref
                                                       Power        Power         (mW/cm2)            (mW/cm2)
                           (dBi)      (numeric)
                                                       (dBm)        (mW)             Eref
 2400.0 - 2483.5 (BLE)      1.80         1.51           3.06          2.00            1.00                 0.001                 0.001
    5470.0 - 5725.0         4.90         3.09          21.19         131.50           1.00                 0.08                  0.08
                                                                                                Summation of Ratio:              0.081
The Total Evaluation was calculated using the formula:



Where
Ei: calculated E-field Strength for transmitter
Eref: E-field strength related limit

Note: for mobile or fixed location transmitters the minimum separation distance is 20cm, even if calculations
indicate the MPE distance to be less.

Specification - Maximum Permissible Exposure Limits

The Limit is defined in Table 1 of FCC §1.1310.




                  Issue Date:       3rd September 2019                                         Page:       3 of 4
                 This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                            personnel. All changes will be noted in the Document History section of the report.
    MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


       575 Boulder Court
Pleasanton, California 94566, USA
     Tel: +1 (925) 462 0304
     Fax: +1 (925) 462 0306
      www.micomlabs.com



Document Created: 2019-10-12 02:51:15
Document Modified: 2019-10-12 02:51:15

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC