RFx

FCC ID: Q9DAPIN0214215

RF Exposure Info

Download: PDF
FCCID_2410538

                               Maximum Permissible Exposure

ARUB179-1;                  Aruba APIN0214, APIN0215

FCC, Part 15 §1.1310
Industry Canada RSS-Gen §5.6

Calculations for Maximum Permissible Exposure Levels
Power Density = Pd (mW/cm2) = EIRP/(4πd2)
EIRP = P * G
P = Peak output power (mW)
G = Antenna numeric gain (numeric)
d = Separation distance (cm)
Numeric Gain = 10 ^ (G (dBi)/10)
Because the EUT belongs to the General Population/Uncontrolled Exposure the limit of
power density is 1.0 mW/cm2

The calculations in the table below use highest gain antennas for the client EUT. Where
the antenna gain exceeds 6dBi the transmitter power is reduced where necessary to
meet the EIRP requirements. These calculations represent worst case in terms of the
exposure levels.

                                               Peak        Peak      Calculated         Minimum
                                  Numeric
  Freq. Band      Antenna                     Output      Output    Safe Distance      Separation
                                   Gain
    (MHz)         Gain (dBi)                  Power       Power      @ 1mW/cm2          Distance
                                 (numeric)
                                              (dBm)       (mW)        Limit(cm)           (cm)
 2400 – 2483.5        7.5          5.62        23.32       215           9.9               20
  5725 - 5850         7.5          5.62        22.87       194            9.4              20
  5150 - 5250         7.5          5.62        16.84        49            4.7              20
  5250 - 5350         7.5          5.62        22.39       174            8.9              20
  5470 - 5725         7.5          5.62        22.41       175            8.9              20

Note: for mobile or fixed location transmitters the minimum separation distance is 20cm,
even if calculations indicate the MPE distance to be less.

Specification
Maximum Permissible Exposure Limits


 FCC §1.1310 Limit = 1mW / cm2 from 1.310 Table 1

 RSS-Gen §5.6 Category I and Category II equipment shall comply with the applicable
 requirements of RSS-102.

Laboratory Measurement Uncertainty for Power Measurements

 Measurement uncertainty                       ±1.33 dB



Document Created: 2014-08-22 12:02:07
Document Modified: 2014-08-22 12:02:07

© 2024 FCC.report