MPE 15 247

FCC ID: Q9DAP120121SDR

RF Exposure Info

Download: PDF
FCCID_951196

May 28, 2008

Maximum Permissible Exposure

FCC, Part 15 Subpart C §15.247(i)
Industry Canada RSS-Gen §5.5

Calculations for Maximum Permissible Exposure Levels
Power Density = Pd (mW/cm2) = EIRP/(4πd2)
EIRP = P * G
P = Peak output power (mW)
G = Antenna numeric gain (numeric)
d = Separation distance (cm)
Numeric Gain = 10 ^ (G (dBi)/10)

The Aruba AP120, AP121 has three transmitters. The peak power in the table below is calculated
by assuming a worst case scenario where the three transmitters are operating simultaneously in
the same band. The Peak Power in mW is calculated by taking the maximum allowable
conducted power measured in each band and multiplying by 3.
Because the EUT belongs to the General Population/Uncontrolled Exposure the limit of power
density is 1.0 mW/cm2

                                                                                  Calculated
                                                     Peak            Peak                             Minimum
    Freq.        Antenna          Numeric                                            Safe
                                                    Output          Output                           Separation
    Band          Gain             Gain                                           Distance @
                                                    Power           Power                             Distance
    (GHz)         (dBi)          (numeric)                                         1mW/cm2
                                                    (dBm)           (mW)                                (cm)
                                                                                   Limit(cm)
     2.4             12             15.85            24.00           753.6            30.83              30.83
     5.8             14             25.11            21.12          388.26            27.85              27.85

*Note: for mobile or fixed location transmitters the minimum separation distance is 20cm, even if
calculations indicate the MPE distance to be less.

Specification
Maximum Permissible Exposure Limits

 §15.247(i) Systems operating under the provisions of this section shall be operated in a manner that
 ensures that the public is not exposed to radio frequency levels in excess of the Commission’s
 guidelines.

 FCC §1.1310 Limit = 1mW / cm2 from 1.310 Table 1

 RSS-Gen §5.5 Before equipment certification is granted, the applicable requirements of RSS-102
 shall be met.




  440 Boulder Court, Suite 200, Pleasanton, California 94566, USA Tel.: +1 925 462 0304, Fax: +1 925 462 0306