MPE Prediction

FCC ID: Q9D651

RF Exposure Info

Download: PDF
FCCID_1111416

                                                                      the wireless lab


Maximum Permissible Exposure
FCC, Part 15 Subpart C §15.407(f)
Industry Canada RSS-Gen §5.5


Calculations for Maximum Permissible Exposure Levels
Power Density = Pd (mW/cm2) = EIRP/(4πd2)
EIRP = P * G * 3
P = Peak output power (mW)
G = Antenna numeric gain (numeric)
d = Separation distance (cm)
Numeric Gain = 10 ^ (G (dBi)/10)
The Aruba 651-XX has three transmitters. The peak power in the table below is
calculated by assuming a worst case scenario where the three transmitters are operating
simultaneously in the same band. The Peak Power in mW is calculated by taking the
maximum conducted power measured in each band and multiplying by 3.
Because the EUT belongs to the General Population/Uncontrolled Exposure the limit of
power density is 1.0 mW/cm2

                                                                            Calculated
                                                  Peak          Peak                      Minimum
                                 Numeric                                       Safe
 Freq. Band     Antenna                          Output        Output                    Separation
                                  Gain                                      Distance @
   (MHz)        Gain (dBi)                       Power         Power                      Distance
                                (numeric)                                    1mW/cm2
                                                 (dBm)         (mW)                         (cm)
                                                                             Limit(cm)
 5150 - 5250        5.8              3.8          +17.00        150.4            6.7        20

Note: for mobile or fixed location transmitters the minimum separation distance is 20cm,
even if calculations indicate the MPE distance to be less.

Specification
Maximum Permissible Exposure Limits


 FCC §1.1310 Limit = 1mW / cm2 from 1.310 Table 1

 RSS-Gen §5.5 Before equipment certification is granted, the application requirements of
 RSS-102 shall be met.




                    MiCOM Labs, 440 Boulder Court, Suite 200, Pleasanton, CA 94566
               Tel: +1 (925) 462-0304, Fax: +1 (925) 462-0306, Web: www.micomlabs.com



Document Created: 2009-05-15 11:19:30
Document Modified: 2009-05-15 11:19:30