@l                                                                                 Report Number: 1901FS16




                         SAR Exclusion Evaluation Report




Applicant                  Mobile Action Technology Inc.

Product Type               Bluetooth 4.0 Low Energy Wristband

Trade Name                 Q—Watch

Model Number               Q—90

Received Date              Jan. 11, 2019

Test Period                Jan. 23, 2019

Issue Date                 Jan. 28, 2019



                                                Issue by




 Approved By         :     ‘:’;AIEOVL HU                  Tested By

                                (Edison Hu)


A Test Lab Techno Corp.
No. 140—1, Changan Street, Bade District,

Taoyuan City 33465, Taiwan (R.O.C)
Tel : +886—3—2710188 / Fax : +886—3—2710190
Taiwan Accreditation Foundation accreditation number: 1330
Test Firm MRA designation number: TWOO10

 Note: This report shall not be reproduced except in full, without the written approval of A Test Lab Techno
 Corp.. This document may be altered or revised by A Test Lab Techno Corp. personnel only, and shall be
 noted in. the revision section of the document. The client should not use it .to claim product endorsement
 by TAF, or any government agencies. The test results in the report only apply to the tested sample.




                                                 1 of 7


                                                     Report Number: 1901FS16




                               Revision History


Rev.    Issue Date                       Revisions         Revised By
00     Jan. 28, 2019   Initial Issue                       Shelly Chen




                                       2 of 7


                                                                                                  Report Number: 1901FS16




                                                   Contents

1.   Description of Equipment under Test (EUT) ....................................................................4
2.   Reference Testing Standards ..........................................................................................4
3.   SAR Test Exclusion .........................................................................................................5
     3.1        Conducted Power ...............................................................................................6
     3.2        Antenna Location ................................................................................................6
     3.3        Evaluation Results ..............................................................................................7




                                                          3 of 7


                                                                                            Report Number: 1901FS16


1.   Description of Equipment under Test (EUT)
                                      Mobile Action Technology Inc.
      Applicant
                                      5F., No.205-3, Sec.3, Beishin Rd., Shindian City Taipei Taiwan 231
                                      Heisei Technology Co., Ltd.
      Manufacturer
                                      2F.,No.5,Aly.8,Ln.45.,Baoxing Rd.,Xindian Dist.,New Taipei City 231,Taiwan,R.O.C.
      Product Type                    Bluetooth 4.0 Low Energy Wristband
      Trade Name                      Q-Watch
      Model Number                    Q-90
      FCC ID                          Q7Z-19H90R1
                                                                                            Frequency Range
                                                   Operate Band
      Frequency Range                                                                            (MHz)
                                                    Bluetooth LE                               2402 ~ 2480
                                                                                                Max. Gain
                                                        Type
      Antenna Information                                                                         (dBi)
                                                    FPC Antenna                                   -7.33

     The above equipment was tested by A Test Lab Techno Corp. For compliance with the requirements set forth in 47
     CFR § 2.1093. The results of testing in this report apply only to the product/system, which was tested. Other similar
     equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties.




2.   Reference Testing Standards
               Standard                                         Description                                   Version
                                  American National Standard safety levels with respect to human
      ANSI/IEEE C95.1             exposure to radio frequency electromagnetic fields, 300 KHz to 100           1992
                                  GHz, New York.
                                  IEEE Recommended Practice for Determining the Peak
      IEEE 1528                   Spatial-Average Specific Absorption Rate (SAR) in the Human Head             2013
                                  From Wireless Communications Devices: Measurement Techniques.
      FCC 47 CFR Part 2.1093      Radiofrequency radiation exposure evaluation: portable devices.               ---
                                  SAR measurement 100 MHz to 6 GHz - describes SAR
      FCC KDB 865664 D01          measurement procedures for devices operating between 100 MHz to             v01r04
                                  6 GHz
                                  RF Exposure Reporting - provides general reporting requirements as
      FCC KDB 865664 D02          well as certain specific information required to support MPE and SAR        v01r02
                                  compliance.
                                  General RF Exposure Guidance - provides guidance pertaining to
      FCC KDB 447498 D01          RF exposure requirements for mobile and portable device equipment             v06
                                  authorizations.




                                                       4 of 7


                                                                                             Report Number: 1901FS16


3.   SAR Test Exclusion
     As RF exposure evaluation of portable device, SAR test is not required when the evaluation results. According to

     KDB 447498 4.3.1, unless excluded by specific FCC test procedures, portable devices shall include SAR data for

     equipment approval. SAR test necessity will be based on the exclusion result.


     The test exclusion refers KDB 447498 as below:

     ≤50 mm:
     [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for

     1-g SAR and ≤ 7.5 for 10-g extremity SAR



     >50 mm and <200 mm:
     a) [Power allowed at numeric threshold for 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)]

         mW, at 100 MHz to 1500 MHz

     b) [Power allowed at numeric threshold for 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500

         MHz and ≤ 6 GHz




                                                       5 of 7


@l                                                                                               Report Number: 1901516




3.1   Conducted Power

      The conducted power turn—up folerance, please reference manufacturer specifcation
        Operate Band      |Modulation Type     D(EhtAEbE:]te            Frmf;}“y            Ave’ffgr:]“w”
                                                                         24020                  10
        Blustooth LE          srek                   1                   2eso 0                 as1
                                                                         2seo 0                 280


3.2. Antenna Location

                               Transmitter and entenn imglementation
                       Operate Band                                     Bluetooth Antenns
                        Bluetooth LE                                            v

                                                     Antenna to user distance
            Ant Used                                              imm}
                                             Front                                 Back
        Bluetooth Antenna                      s                                     s
      Note We use a minimum distance of 5mm for blustooth function




                                                               6 of 7


                                                                                       Report Number: 1901FS16




3.3 Evaluation Results

    The evaluation of SAR test reduction according to KDB447498

    SAR test is not required when the results showed “EXEMPT”.


                                                    SAR test reduction

                                        Frequency            Tune-Power              Calculated threshold value
       Ant. Used          Band
                                          (GHz)         (dBm)       (mW)             Front                Back

       Bluetooth                                                                      0.5                  0.5
                      Bluetooth LE         2.48              2      1.585
       Antenna                                                                     EXEMPT               EXEMPT



    Exclusion Considerations: SAR is not required


    Note: 1. Calculated Value include string "mW",that is meam through compare output power with threshold, if the
              output power more than threshold value the SAR test should be perform. Otherwise,the SAR test could be
              exempt. (> 50 mm)
          2. Calculated Value only inculde number format, that is mean through compare output power with threshold,
             if the Calculated value more than 3, the SAR test should be perform. Otherwise, the SAR test could be
             exempt. (<50 mm)
          3. When an antenna qualifies for the standalone SAR test exclusion of KDB 447498 section 4.3.1 and also
             transmits simultaneously with other antennas, the standalone SAR value must be estimated according to
             KDB 447498 section "4.3.2. Simultaneous transmission SAR test exclusion considerations b) ".
          4. We used highest frequency and power, that result should be evaluated the worst case.
          5. Power and distance are rounded to the nearest mW and mm before calculation.
          6. The result is rounded to one decimal place for comparison.
          7. We use a minimum distance of 5 mm for bluetooth function.