Test Report

FCC ID: Q5ETP66001

Test Report

Download: PDF
FCCID_2608378

                                               FCC PART 90
                                               TEST REPORT

                                                               For

                        Kirisun Communications Co., Ltd.
3-6Flrs, ROBETA Building, No.1, QiMin Road, Song Ping Shan Area, Science & Industry Park, Nanshan
                               District, Shenzhen 518057 P.R.China



                                         FCC ID: Q5ETP66001


           Report Type:                                       Product Type:
           Original Report                                    DMR Two Way Radio



                  Test Engineer:         Dean Liu

                Report Number:           RDG150122002-00

                    Report Date:         2015-04-13


                                         Jerry Zhang
                   Reviewed By:          EMC Manager

               Test Laboratory:          Bay Area Compliance Laboratories Corp. (Dongguan)
                                         No.69 Pulongcun, Puxinhu Industrial Zone,
                                         Tangxia, Dongguan, Guangdong, China
                                         Tel: +86-769-86858888
                                         Fax: +86-769-86858891
                                         www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report is valid only
with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                           Report No.: RDG150122002-00




                                                       TABLE OF CONTENTS


GENERAL INFORMATION .......................................................................................................................................4
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................4
 OBJECTIVE ...................................................................................................................................................................4
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................4
 TEST METHODOLOGY ..................................................................................................................................................4
 TEST FACILITY .............................................................................................................................................................5
SYSTEM TEST CONFIGURATION ..........................................................................................................................6
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................6
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7

FCC §1.1310 & §2.1093 - RF EXPOSURE..................................................................................................................8
  APPLICABLE STANDARD ..............................................................................................................................................8
  TEST RESULT ...............................................................................................................................................................8
FCC §2.1046§90.205- RF OUTPUT POWER .............................................................................................................9
  APPLICABLE STANDARD ..............................................................................................................................................9
  TEST PROCEDURE ........................................................................................................................................................9
  TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................9
  TEST DATA ..................................................................................................................................................................9
FCC §2.1047 & §90.207 - MODULATION CHARACTERISTIC ..........................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  TEST PROCEDURE ......................................................................................................................................................11
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................11
  TEST DATA ................................................................................................................................................................11
FCC §2.1049 &§90.209 & §90.210 – OCCUPIED BANDWIDTH & EMISSION MASK ....................................15
  APPLICABLE STANDARD ............................................................................................................................................15
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................16
  TEST PROCEDURE ......................................................................................................................................................16
  TEST DATA ................................................................................................................................................................16
FCC §2.1051 & §90.210 - SPURIOUS EMISSIONS AT ANTENNA TERMINALS ............................................22
  APPLICABLE STANDARD ............................................................................................................................................22
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................22
  TEST PROCEDURE ......................................................................................................................................................23
  TEST DATA ................................................................................................................................................................23
FCC §2.1053 & §90.210 - RADIATED SPURIOUS EMISSIONS ..........................................................................26
  APPLICABLE STANDARD ............................................................................................................................................26
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................26
  TEST PROCEDURE ......................................................................................................................................................26
  TEST DATA ................................................................................................................................................................27
FCC §2.1055 & §90.213- FREQUENCY STABILITY ...........................................................................................28
  APPLICABLE STANDARD ............................................................................................................................................28
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................28
  TEST PROCEDURE ......................................................................................................................................................28

FCC Part 90                                                                                                                                              Page 2 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                           Report No.: RDG150122002-00


    TEST DATA ................................................................................................................................................................28
FCC §90.214 - TRANSIENT FREQUENCY BEHAVIOR ......................................................................................30
  APPLICABLE STANDARD ............................................................................................................................................30
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................30
  TEST PROCEDURE ......................................................................................................................................................30
  TEST DATA ................................................................................................................................................................31




FCC Part 90                                                                                                                                               Page 3 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                                Report No.: RDG150122002-00


GENERAL INFORMATION
Product Description for Equipment under Test (EUT)
The Kirisun Communications Co. ,Ltd.’s product, model: TP660 (FCC ID: Q5ETP66001) (the "EUT") in
this report is a DMR Two Way Radio, which was measured approximately: 22.2 cm (H) x5.9 cm (W) x 3.9
cm (T), rated input voltage: DC 7.4V from lithium battery.

* All measurement and test data in this report was gathered from production sample serial number:
 411915010000001(Assigned by applicant). The EUT was received on 2015-01-23.


Objective
This test report is prepared on behalf of Kirisun Communications Co. ,Ltd. in accordance with Part 2 and
Part 90 of the Federal Communications Commission rules.


Related Submittal(s)/Grant(s)
No related submittal(s).


Test Methodology
All tests and measurements indicated in this document were performed in accordance with the Code of
federal Regulations Title 47 Part 2, Sub-part J as well as the following individual parts:

Part 90 – Private Land Mobile Radio Service

Applicable Standards: TIA 603-D and ANSI 63.4-2003.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).
The radiated testing was performed at an antenna-to-EUT distance of 3 meters.




FCC Part 90                                                                                         Page 4 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG150122002-00


Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industrial Zone, Tangxia, Dongguan, Guangdong, China

Test site at Bay Area Compliance Laboratories Corp. (Dongguan) has been fully described in reports
submitted to the Federal Communications Commission (FCC). The details of these reports have been
found to be in compliance with the requirements of Section 2.948 of the FCC Rules on February 06, 2015.
The facility also complies with the radiated and AC line conducted test site criteria set forth in ANSI
C63.4-2009.
The Federal Communications Commission has the reports on file and is listed under FCC Registration No.:
273710. The test site has been approved by the FCC for public use and is listed in the FCC Public Access
Link (PAL) database.




FCC Part 90                                                                                 Page 5 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                                   Report No.: RDG150122002-00


SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in a test mode.


EUT Specification:

                Operating Frequency Band                    136 -174 MHz
                Modulation Mode                             FM/4FSK
                Channel Separation                          12.5 kHz
                                                            High power level: 5 W
                Rated Output Power                          Low power level: 1 W


Block Diagram of Test Setup




                                                                   Load




                                                                                                  1.0 Meter
                                                                 EUT



                                 Non-conductive table 150 cm
                                   Non-conductive
                                 above            table 150 cm
                                       Ground Plane
                                   above Ground Plane

        Non-conductive table 80 cm
        above Ground Plane

                                                     1.5 Meter




FCC Part 90                                                                                                   Page 6 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RDG150122002-00


SUMMARY OF TEST RESULTS


                FCC Rules                     Description of Test                     Results

                  §2.1093                           RF Exposure                      Compliant

              §2.1046;§90.205                  RF Output Power                       Compliant

              §2.1047;§90.207              Modulation Characteristic                 Compliant
              §2.1049;§90.209;
                                     Occupied Bandwidth & Emission Mask              Compliant
                  §90.210
              §2.1051;§90.210        Spurious Emission at Antenna Terminal           Compliant

              §2.1053;§90.210             Spurious Radiated Emissions                Compliant

              §2.1055;§90.213                 Frequency Stability                    Compliant

                  §90.214                Transient Frequency Behavior                Compliant




FCC Part 90                                                                                     Page 7 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)              Report No.: RDG150122002-00


FCC §1.1310 & §2.1093 - RF EXPOSURE
Applicable Standard
FCC§1.1310 and §2.1093.


Test Result
Compliance, please refer to the SAR report: RDG150122002-20A




FCC Part 90                                                                    Page 8 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                                Report No.: RDG150122002-00


FCC §2.1046§90.205- RF OUTPUT POWER
Applicable Standard
FCC §2.1046 and §90.205.


Test Procedure
Conducted RF Output Power:

TIA-603-D section 2.2.1

The RF output of the transmitter was connected to the input of the spectrum analyzer through sufficient
attenuation.

Spectrum Analyzer setting:

                                      RBW                               VBW
                                     100 kHz                           300 kHz


Test Equipment List and Details

                                                                                   Calibration   Calibration
      Manufacturer             Description         Model No.       Serial No.
                                                                                      Date        Due Date

            R&S             Spectrum Analyzer        FSP 38          100478        2014-05-09     2015-05-09

   * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
    have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

           Temperature:              21.5 °C
      Relative Humidity:              50 %
         ATM Pressure:               102 kPa

     The testing was performed by Dean Liu on 2015-02-03.




FCC Part 90                                                                                        Page 9 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG150122002-00

Test Result: Compliant. Please refer to following tables.


                                                               Conducted
                                                fc
      Modulation          Channel                             Output Power
                                                            High        Low                Note
        mode             Separation
                                              MHz
                                                             W          W
                                            136.0125        5.18       1.06        Not for FCC Review
          FM                                155.0125        5.15       1.04                 /
                                            173.9875        5.16       1.05                 /
                           12.5 kHz
                                            136.0125        5.17       1.03        Not for FCC Review
         4FSK                               155.0125        5.18       1.04                 /
                                            173.9875        5.16       1.06                 /




FCC Part 90                                                                                     Page 10 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG150122002-00


FCC §2.1047 & §90.207 - MODULATION CHARACTERISTIC
Applicable Standard
FCC§2.1047 & §90.207:

    (a) Equipment which utilizes voice modulated communication shall show the frequency response of
        the audio modulating circuit over a range of 100 to 5000 Hz. for equipment which is required to
        have a low pass filter, the frequency response of the filter, or all of the circuitry installed between
        the modulation limited and the modulated stage shall be supplied.
    (b) Equipment which employs modulation limiting, a curve showing the percentage of modulation
        versus the modulation input voltage shall be supplied.


Test Procedure
Test Method: TIA/EIA-603 2.2.3


Test Equipment List and Details

                                                                                 Calibration    Calibration
     Manufacturer             Description           Model No.     Serial No.
                                                                                    Date         Due Date
                          RF Communications
           HP                                          8920A        00 235       2014-05-09     2015-05-09
                               Test Set

   * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
   have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

           Temperature:                21.5°C
      Relative Humidity:                50 %
         ATM Pressure:                 102 kPa

     The testing was performed by Dean Liu on 2015-02-03.


     Test Result: Compliant. Please refer to following plots.




FCC Part 90                                                                                        Page 11 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG150122002-00

                                     MODULATION LIMITING

          Carrier Frequency: 155.0125 MHz, Channel Separation = 12.5 kHz, high power level

               AUDIO INPUT           DEVIATION      DEVIATION   DEVIATION
                                                                                 Limit
                 LEVEL                (@300Hz)       (@ 1kHz)    (@ 3kHz)
                    dB                  kHz            kHz         kHz           kHz
                   20.0                 1.493          1.832       1.752         2.5
                   15.0                 1.436          1.826       1.713         2.5
                   10.0                 0.999          1.792       1.652         2.5
                    5.0                 0.588          1.669       1.555         2.5
                    0.0                 0.350          1.500       1.519         2.5
                   -5.0                 0.228          0.853       1.328         2.5
                  -10.0                 0.153          0.501       0.806         2.5
                  -15.0                 0.123          0.304       0.471         2.5
                  -20.0                 0.095          0.197       0.282         2.5




FCC Part 90                                                                              Page 12 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG150122002-00


                                        Audio Frequency Response

          Carrier Frequency: 155.0125 MHz, Channel Separation = 12.5 kHz, high power level

                              Audio                      Response
                            Frequency                   Attenuation
                               Hz                           dB
                               300                        -12.59
                               400                         -9.34
                               500                         -6.99
                               600                         -5.02
                               700                         -3.54
                               800                         -2.08
                               900                         -1.05
                              1000                         0.00
                              1200                         1.66
                              1400                         3.14
                              1600                         4.35
                              1800                         5.52
                              2000                         6.66
                              2200                         7.43
                              2400                         8.17
                              2600                         8.84
                              2800                         9.16
                              3000                         8.36




FCC Part 90                                                                             Page 13 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG150122002-00


                              Audio Frequency Low Pass Filter Response

          Carrier Frequency: 155.0125 MHz, Channel Separation = 12.5 kHz, high power level

                                 Audio          Response
                                                              Limit
                               Frequency       Attenuation
                                  kHz               dB           dB
                                   3.0             -2.1          0.0
                                   3.5            -10.3         -6.7
                                   4.0            -17.7        -12.5
                                   5.0            -27.7        -22.2
                                   7.0            -44.7        -36.8
                                  10.0            -59.5        -52.3
                                  15.0            -78.5        -69.9
                                  20.0            -84.3        -82.5
                                  30.0            -84.3        -82.5
                                  50.0            -85.0        -82.5
                                  70.0            -84.6        -82.5




FCC Part 90                                                                             Page 14 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                                    Report No.: RDG150122002-00


FCC §2.1049 &§90.209 & §90.210 – OCCUPIED BANDWIDTH &
EMISSION MASK
Applicable Standard
FCC §2.1049,§90.209 and §90.210

                                            Applicable Emission Masks
                                            Mask for equipment                        Mask for equipment
 Frequency band (MHz)                         with audio low                           without audio low
                                                pass filter                                pass filter
            Below 25                              A or B                                    A or C
              25-50                                  B                                         C
              72-76                                  B                                         C
             150-174                            B, D, or E                                 C, D or E
        150 paging only                              B                                         C
             220-222                                 F                                         F
             421-512                            B, D, or E                                 C, D, or E
        450 paging only                              B                                         G
        806-809/851-854                              B                                         H
        809-824/854-869                              B                                         G
        896-901/935-940                              I                                         J
             902-928                                 K                                         K
             929-930                                 B                                         G
        4940-4990 MHz                             L or M                                    L or M
           5850-5925
         All other bands                              B                                         C

      Emission Mask D—12.5 kHz channel bandwidth equipment. For transmitters designed to operate with a 12.5
kHz channel bandwidth, any emission must be attenuated below the power (P) of the highest emission contained
within the authorized bandwidth as follows:

      (1) On any frequency from the center of the authorized bandwidth f0 to 5.625 kHz removed from f0: Zero dB.

     (2) On any frequency removed from the center of the authorized bandwidth by a displacement frequency (fd in
kHz) of more than 5.625 kHz but no more than 12.5 kHz: At least 7.27(fd−2.88 kHz) dB.

     (3) On any frequency removed from the center of the authorized bandwidth by a displacement frequency (fd in
kHz) of more than 12.5 kHz: At least 50 + 10 log (P) dB or 70 dB, whichever is the lesser attenuation.

      (4) The reference level for showing compliance with the emission mask shall be established using a resolution
bandwidth sufficiently wide (usually two or three times the channel bandwidth) to capture the true peak emission of
the equipment under test. In order to show compliance with the emission mask up to and including 50 kHz removed
from the edge of the authorized bandwidth, adjust the resolution bandwidth to 100 Hz with the measuring instrument
in a peak hold mode. A sufficient number of sweeps must be measured to insure that the emission profile is
developed. If video filtering is used, its bandwidth must not be less than the instrument resolution bandwidth. For
emissions beyond 50 kHz from the edge of the authorized bandwidth, see paragraph (o) of this section. If it can be
shown that use of the above instrumentation settings do not accurately represent the true interference potential of the
equipment under test, an alternate procedure may be used provided prior Commission approval is obtained.




FCC Part 90                                                                                              Page 15 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG150122002-00

Test Equipment List and Details

                                                                                   Calibration   Calibration
      Manufacturer             Description         Model No.       Serial No.
                                                                                      Date        Due Date

            R&S             Spectrum Analyzer        FSEM           DE31388        2014-05-09     2015-05-09
                           RF Communications
              HP                                     8920A           00 235        2014-05-09     2015-05-09
                                Test Set

   * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
   have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Procedure
The RF output of the transmitter was connected to the input of the spectrum analyzer through sufficient
attenuation.


Test Data
     Environmental Conditions

           Temperature:            20~26.1 °C
      Relative Humidity:            38~74 %
         ATM Pressure:           100.3~102.1 kPa

     The testing was performed by Dean Liu from 2015-02-03 to 2015-04-02.




FCC Part 90                                                                                        Page 16 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG150122002-00

     Test Result: Compliant. Please refer to the following tables and plots.

                                   Channel                         26 dB
                Modulation                            fc                          Power
                                  Separation                     Bandwidth
                  Mode                                                            Level
                                     kHz            MHz              kHz
                     FM                                             10.37
                                                                                   High
                    4FSK                                             8.68
                                     12.5         155.0125
                     FM                                             10.36
                                                                                   Low
                    4FSK                                             8.55




                     Occupied Bandwidth – FM, 155.0125 MHz, High Power Level




FCC Part 90                                                                                    Page 17 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                Report No.: RDG150122002-00


                                        Emission Mask - Type D




                    Occupied Bandwidth – FM, 155.0125 MHz, Low Power Level




FCC Part 90                                                                      Page 18 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                Report No.: RDG150122002-00


                                        Emission Mask - Type D




                   Occupied Bandwidth –4FSK, 155.0125 MHz, High Power Level




FCC Part 90                                                                      Page 19 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                Report No.: RDG150122002-00


                                        Emission Mask - Type D




                   Occupied Bandwidth – 4FSK, 155.0125 MHz, Low Power Level




FCC Part 90                                                                      Page 20 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                Report No.: RDG150122002-00


                                        Emission Mask - Type D




FCC Part 90                                                                      Page 21 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                                    Report No.: RDG150122002-00


FCC §2.1051 & §90.210 - SPURIOUS EMISSIONS AT ANTENNA
TERMINALS
Applicable Standard

      Emission Mask D—12.5 kHz channel bandwidth equipment. For transmitters designed to operate with a 12.5
kHz channel bandwidth, any emission must be attenuated below the power (P) of the highest emission contained
within the authorized bandwidth as follows:

      (1) On any frequency from the center of the authorized bandwidth f0 to 5.625 kHz removed from f0: Zero dB.

     (2) On any frequency removed from the center of the authorized bandwidth by a displacement frequency (fd in
kHz) of more than 5.625 kHz but no more than 12.5 kHz: At least 7.27(fd−2.88 kHz) dB.

     (3) On any frequency removed from the center of the authorized bandwidth by a displacement frequency (fd in
kHz) of more than 12.5 kHz: At least 50 + 10 log (P) dB or 70 dB, whichever is the lesser attenuation.

      (4) The reference level for showing compliance with the emission mask shall be established using a resolution
bandwidth sufficiently wide (usually two or three times the channel bandwidth) to capture the true peak emission of
the equipment under test. In order to show compliance with the emission mask up to and including 50 kHz removed
from the edge of the authorized bandwidth, adjust the resolution bandwidth to 100 Hz with the measuring instrument
in a peak hold mode. A sufficient number of sweeps must be measured to insure that the emission profile is
developed. If video filtering is used, its bandwidth must not be less than the instrument resolution bandwidth. For
emissions beyond 50 kHz from the edge of the authorized bandwidth, see paragraph (o) of this section. If it can be
shown that use of the above instrumentation settings do not accurately represent the true interference potential of the
equipment under test, an alternate procedure may be used provided prior Commission approval is obtained.


Test Equipment List and Details

                                                                                        Calibration    Calibration
       Manufacturer              Description          Model No.        Serial No.
                                                                                           Date         Due Date

            R&S               Spectrum Analyzer         FSEM            DE31388         2014-05-09     2015-05-09
                             RF Communications
              HP                                        8920A            00 235         2014-05-09     2015-05-09
                                  Test Set

   * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
   have been performed, traceable to National Primary Standards and International System of Units (SI).




FCC Part 90                                                                                              Page 22 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG150122002-00

Test Procedure
Adjust the spectrum analyzer for the following settings:
1) Resolution Bandwidth = 100 kHz for spurious emissions below 1 GHz, and 1 MHz for spurious
   emissions above 1 GHz.
2) Video Bandwidth ≥3 times the resolution bandwidth.
3) Sweep Speed ≤2000 Hz per second.
4) Detector Mode = RMS or average power.


Test Data
     Environmental Conditions

           Temperature:           20~27.3 °C
      Relative Humidity:           38~74 %
         ATM Pressure:          100.1~102.1 kPa

     The testing was performed by Dean Liu from 2015-02-03 to 2015-04-15.


Note: for conducted spurious emissions were tested at high rated power, which was the worst case. And
      there was a band reject filter between the EUT and test equipment when testing.




FCC Part 90                                                                                 Page 23 of 32


    Bay Area Compliance Laboratories Corp. (Dongguan)                  Report No.: RDG150122002-00


                                    155.0125 MHz –FM Mode,High Power




Fundamental test
with Band Reject
Filter




    FCC Part 90                                                                        Page 24 of 32


    Bay Area Compliance Laboratories Corp. (Dongguan)                   Report No.: RDG150122002-00


                                   155.0125 MHz –4FSK Mode,High Power




Fundamental test
with Band Reject
Filter




    FCC Part 90                                                                         Page 25 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG150122002-00


FCC §2.1053 & §90.210 - RADIATED SPURIOUS EMISSIONS
Applicable Standard
FCC §2.1053 and §90.210


Test Equipment List and Details

                                                                                Calibration      Calibration
     Manufacturer            Description          Model No.      Serial No.
                                                                                   Date           Due Date

         HP               Signal Generator          8648A       3426A00831       2013-11-06      2014-11-06
        Sunol
                              Antenna                JB3         A060611-3       2014-07-28      2017-07-27
       Sciences
                          Adjustable Dipole
        EMCO                                        3121C         9109-753          N/A              N/A
                              Antenna
          HP                  Amplifier             8447E       2434A02181       2014-09-01      2015-09-01
         R&S             EMI Test Receiver          ESCI           100224        2014-05-09      2015-05-09
        Agilent           Signal Generator         E8247C       MY43321350       2014-10-16      2015-10-16
      Mini-Circuit            Amplifier         ZVA-213-S+       054201245       2015-02-19      2016-02-19
       TDK RF               Horn Antenna          HRN-0118         130 084       2012-09-06      2015-09-06
   ETS LINDGREN             Horn Antenna            3115         000 527 35      2012-09-06      2015-09-06
         R&S             Spectrum Analyzer          FSEM          DE31388        2014-05-09      2015-05-09

   * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
   have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Procedure
The transmitter was placed on a wooden turntable, and it was transmitting into a non-radiating load, which
was also placed on the turntable.

The measurement antenna was placed at a distance of 3 meters from the EUT. During the tests, the antenna
height and polarization as well as EUT azimuth were varied in order to identify the maximum level of
emissions from the EUT .The test was performed by placing the EUT on 3-orthogonal axis.

The frequency range up to tenth harmonic of the fundamental frequency was investigated.

Remove the EUT and replace it with substitution antenna. A signal generator was connected to the
substitution antenna by a non-radiating cable. The absolute levels of the spurious emissions were measured
by the substitution.

For part 90:
Spurious emissions in dB =10 1og10 (TXpwr in Watts/0.001)-the absolute level

Spurious attenuation limit in dB =50+10 Log10 (power out in Watts) for EUT with a 12.5 kHz channel
bandwidth.




FCC Part 90                                                                                        Page 26 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG150122002-00

Test Data
     Environmental Conditions

           Temperature:             24.3 °C
      Relative Humidity:             52 %
         ATM Pressure:             101.3 kPa

     The testing was performed by Dean Liu on 2015-04-10.

  Test Mode: Transmitting (FM mode, high power level)

                               S.A.      S.G.    Antenna     Cable   Absolute
     Frequency      Polar                                                        Limit    Margin
                             Reading     Level     Gain      Loss     Level
        MHz         H/V       dBµV       dBm     dBd/dBi      dB      dBm         dBm       dB
                                         Frequency:155.0125 MHz
      310.025        H        32.73      -73.5      0.0       0.5      -74.0      -20.0     54.0
      465.038        H        45.60      -45.2      0.0       0.7      -45.9      -20.0     25.9
      620.050        H        33.49      -58.8      0.0       0.8      -59.6      -20.0     39.6
      775.063        H        49.76      -41.3      0.0       0.9      -42.2      -20.0     22.2
      930.075        H        38.52      -50.6      0.0        1       -51.6      -20.0     31.6
      1085.088       H        30.11      -69.9      7.5       1.1      -63.5      -20.0     43.5
      310.025        V        46.16      -57.6      0.0       0.5      -58.1      -20.0     38.1
      465.038        V        47.68      -41.3      0.0       0.7      -42.0      -20.0     22.0
      620.050        V        36.58      -51.8      0.0       0.8      -52.6      -20.0     32.6
      775.063        V        41.29      -47.5      0.0       0.9      -48.4      -20.0     28.4
      930.075        V        39.58      -46.6      0.0        1       -47.6      -20.0     27.6
      1085.088       V        38.54      -61.8      7.5       1.1      -55.4      -20.0     35.4

  Test Mode: Transmitting (4FSK mode, high power level)

                               S.A.      S.G.    Antenna     Cable   Absolute
     Frequency      Polar                                                        Limit    Margin
                             Reading     Level     Gain      Loss     Level
        MHz         H/V       dBµV       dBm     dBd/dBi      dB      dBm         dBm       dB
                                         Frequency:155.0125 MHz
      310.025        H        32.67      -73.6      0.0       0.5      -74.1      -20.0     54.1
      465.038        H        45.58      -45.2      0.0       0.7      -45.9      -20.0     25.9
      620.050        H        33.44      -58.9      0.0       0.8      -59.7      -20.0     39.7
      775.063        H        49.71      -41.4      0.0       0.9      -42.3      -20.0     22.3
      930.075        H        38.42      -50.7      0.0        1       -51.7      -20.0     31.7
      1085.088       H        30.08      -69.9      7.5       1.1      -63.5      -20.0     43.5
      310.025        V        46.06      -57.7      0.0       0.5      -58.2      -20.0     38.2
      465.038        V        47.61      -41.4      0.0       0.7      -42.1      -20.0     22.1
      620.050        V        36.50      -51.9      0.0       0.8      -52.7      -20.0     32.7
      775.063        V        41.21      -47.6      0.0       0.9      -48.5      -20.0     28.5
      930.075        V        39.50      -46.7      0.0        1       -47.7      -20.0     27.7
      1085.088       V        38.49      -61.8      7.5       1.1      -55.4      -20.0     35.4

Note1: For radiated spurious emissions were tested at high rated power, which was the worst case.
Note2: The unit of Antenna Gain is dBd for frequency below 1GHz, and the unit of Antenna Gain is dBi
       for frequency above 1GHz.
Note3: Absolute Level = SG Level - Cable loss + Antenna Gain
       Margin = Limit-Absolute Level




FCC Part 90                                                                               Page 27 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG150122002-00


FCC §2.1055 & §90.213- FREQUENCY STABILITY
Applicable Standard
FCC §2.1055,§90.213


Test Equipment List and Details

                                                                                 Calibration     Calibration
     Manufacturer           Description         Model No.         Serial No.
                                                                                    Date          Due Date
          R&S           Spectrum Analyzer         FSP 38            100478       2014-05-09      2015-05-09
                        High Temperature
       Dongzhixu                                  DP1000         201105083-3     2014-08-11      2015-08-11
                          Test Chamber
         UNI-T             Multimeter             UT39A          M130199938      2014-04-10      2015-04-10

   * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
   have been performed, traceable to National Primary Standards and International System of Units (SI).



Test Procedure
Frequency Stability vs. Temperature: The equipment under test was connected to DC power supply and
the RF output was connected to a frequency counter via feed-through attenuators. The EUT was placed
inside the temperature chamber. The power leads and RF output cable exited the chamber through an
opening made for the purpose.

After the temperature stabilized for approximately 20 minutes, the frequency output was recorded from the
counter.
The frequency stability shall be measured with variation of primary supply voltage as follows:

(1) Vary primary supply voltage from 85 to 115 percent of the nominal value for other than hand carried
    battery equipment.

(2) For hand carried, battery powered equipment, reduce primary supply voltage to the battery operating
    end point which shall be specified by the manufacturer.


Test Data
     Environmental Conditions

           Temperature:               21.5°C
      Relative Humidity:               50 %
         ATM Pressure:                102kPa

     The testing was performed by Dean Liu on 2015-02-03.




FCC Part 90                                                                                        Page 28 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG150122002-00

     Test Mode: Transmitting

                             Reference Frequency: 155.0125 MHz, Limit: 5.0 ppm
                   Temerature        Voltage          Reading         Frequency Error
                       ℃               VDC             MHz                  ppm
                       -30             7.4          155.012728              1.47
                       -20             7.4          155.012721              1.43
                       -10             7.4          155.012737              1.53
                        0              7.4          155.012747              1.59
                       10              7.4          155.012714              1.38
                       20              7.4          155.012714              1.38
                       30              7.4          155.012713              1.37
                       40              7.4          155.012718              1.41
                       50              7.4          155.012752              1.63
                                       8.5          155.012760              1.68
                       20
                                       6.7          155.012784              1.83

         Note: The battery operating end point is 6.7V which specified by the manufacturer.




FCC Part 90                                                                                   Page 29 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                                   Report No.: RDG150122002-00


FCC §90.214 - TRANSIENT FREQUENCY BEHAVIOR
Applicable Standard
Regulations: FCC §90.214
Test method: ANSI/TIA-603-D 2010, section 2.2.19.3


Test Equipment List and Details
                                                                                      Calibration   Calibration
      Manufacturer               Description          Model No.     Serial No.
                                                                                         Date        Due Date
           R&S               Spectrum Analyzer           FSEM        DE31388          2014-05-09    2015-05-09
              HP              Signal Generator           8648A     3426A00831         2013-11-06    2014-11-06

   * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
   have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Procedure
a) Connect the EUT and test equipment as shown on the following block diagram.
b) Set the Spectrum Analyzer to measure FM deviation, and tune the RF frequency to the transmitter
   assigned frequency.
c) Set the signal generator to the assigned transmitter frequency and modulate it with a 1 kHz tone at
   ±12.5 kHz deviation and set its output level to -100dBm.
d) Turn on the transmitter.
e) Supply sufficient attenuation via the RF attenuator to provide an input level to the Spectrum Analyzer
   that is 40 dB below the maximum allowed input power when the transmitter is operating at its rated
   power level. Note this power level on the Spectrum Analyzer as P0.
f) Turn off the transmitter.
g) Adjust the RF level of the signal generator to provide RF power equal to P0. This signal generator RF
   level shall be maintained throughout the rest of the measurement.
h) Remove the attenuation 1, so the input power to the Spectrum Analyzer is increased by 30 dB when the
   transmitter is turned on.
i) Adjust the vertical amplitude control of the spectrum analyzer to display the 1000 Hz at ±4 divisions
   vertically centered on the display. Set trigger mode of the Spectrum Analyzer to “Video”, and tune the
   “trigger level” on suitable level. Then set the “tiger offset” to -10ms for turn on and -15ms for turn off.
j) Turn on the transmitter and the transient wave will be captured on the screen of Spectrum Analyzer.
   Observe the stored display. The instant when the 1 kHz test signal is completely suppressed is
   considered to be ton. The trace should be maintained within the allowed divisions during the period t1
   and t2.
k) Then turn off the transmitter, and another transient wave will be captured on the screen of Spectrum
   Analyzer. The trace should be maintained within the allowed divisions during the period t3.


        EUT             Attenuator 1           Attenuator 2
                                                                         Combiner




                                                                                          Spectrum  Analyzer
                                                                                           Spectrum Analyzer
      Signal
     Generator




FCC Part 90                                                                                          Page 30 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                     Report No.: RDG150122002-00

Test Data
     Environmental Conditions

           Temperature:             21.5°C
      Relative Humidity:             50 %
         ATM Pressure:              102 kPa

     The testing was performed by Dean Liu on 2015-02-03.


       Channel Separation           Transient Period        Maximum frequency
                                                                                    Result
            (kHz)                        (ms)                   difference
                                         <5(t1 )                ±12.5 kHz
               12.5                     <20(t2 )                ±6.25 kHz            Pass
                                         <5(t3 )                ±12.5 kHz

       Please refer to the following plots.




FCC Part 90                                                                           Page 31 of 32


Bay Area Compliance Laboratories Corp. (Dongguan)                     Report No.: RDG150122002-00


                              Turn on – 155.0125 MHz, High power level




                              Turn off – 155.0125 MHz, High power level




                               ***** END OF REPORT *****

FCC Part 90                                                                           Page 32 of 32



Document Created: 2015-05-08 18:27:41
Document Modified: 2015-05-08 18:27:41

© 2024 FCC.report