Test report

FCC ID: Q5EM50-4G

Test Report

Download: PDF
FCCID_4235972

                                                   TEST REPORT
Report Reference No. .................... :               CHTEW19030147                   Report verification:

Project No. ...................................... :      SHT1902018202EW

FCC ID ............................................. :    Q5EM50-4G

Applicant’s name ........................... :            Kirisun Communication Co.,Ltd.

Address ............................................. :   3rd Floor, Building A, Tongfang Information Habour, No.11
                                                          Langshan Road, Nanshan District, Shenzhen 518057, P.R.China

Manufacturer....................................:         Kirisun Communication Co.,Ltd.

Address ............................................. :   3rd Floor, Building A, Tongfang Information Habour, No.11
                                                          Langshan Road, Nanshan District, Shenzhen 518057, P.R.China

Test item description .................... :              PoC Trunked Mobile Radio

Trade Mark ....................................... :      KIRISUN

Model/Type reference ....................... :            M50

Listed Model(s) ................................. :       iTALK 450

Standard ......................................... :      FCC CFR Title 47 Part 15 Subpart C Section 15.225

Date of receipt of test sample……….:                       Feb 25, 2019

Date of testing………………………...:                              Feb 26, 2019- Mar 20, 2019

Date of issue…………………………..:                                Mar 21, 2019

Result .................. …………………...:                     PASS

Compiled by
( position+printedname+signature) ... :                   File administrators Silvia Li

Supervised by
(position+printedname+signature) .... :                   Project Engineer Aaron Fang

Approved by
(position+printedname+signature) .... :                   RF Manager Hans Hu

Testing Laboratory Name ............. :                   Shenzhen Huatongwei International Inspection Co., Ltd.

Address ............................................. :   1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road,
                                                          Tianliao, Gongming, Shenzhen, China

Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen Huatongwei International Inspection Co., Ltd. is acknowledged as copyright owner and source
of the material. Shenzhen Huatongwei International Inspection Co., Ltd. takes no responsibility for and will
not assume liability for damages resulting from the reader's interpretation of the reproduced material due to
its placement and context.
The test report merely correspond to the test sample.

                                                                 Page: 1 of 23


Report No : CHTEW19030147                     Page 2 of 23               Issued: 2019-03-21




                                              Contents

1.      TEST STANDARDS AND REPORT VERSION                                                           3

1.1.    Test Standards                                                                          3
1.2.    Report version information                                                              3

2.      TEST DESCRIPTION                                                                            4

3.      SUMMARY                                                                                     5

3.1.    Client Information                                                                      5
3.2.    Product Description                                                                     5
3.3.    EUT operation mode                                                                      6
3.4.    EUT configuration                                                                       6

4.      TEST ENVIRONMENT                                                                            7

4.1.    Address of the test laboratory                                                          7
4.2.    Test Facility                                                                           7
4.3.    Environmental conditions                                                                8
4.4.    Statement of the measurement uncertainty                                                8
4.5.    Equipments Used during the Test                                                         9

5.      TEST CONDITIONS AND RESULTS                                                             11

5.1.    Antenna requirement                                                                     11
5.2.    AC Power Conducted Emissions                                                            12
5.3.    Field Strength of the Fundamental and Mask Measurement                                  13
5.4.    20dB Bandwidth                                                                          15
5.5.    Radiated Emission                                                                       17
5.6.    Frequency Stability                                                                     21

6.      TEST SETUP PHOTOS OF THE EUT                                                            22

7.      EXTERNAL AND INTERNAL PHOTOS OF THE EUT                                                 23




Shenzhen Huatongwei International Inspection Co., Ltd.       Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                         Page 3 of 23               Issued: 2019-03-21



1. TEST STANDARDS AND REPORT VERSION
1.1. Test Standards
The tests were performed according to following standards:
FCC Rules Part 15.225: Operation within the band 13.110-14.010 MHz.
ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices.


1.2. Report version information
      Revision No.                Date of issue                          Description
          N/A                     2019-03-21                               Original




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                     Page 4 of 23                     Issued: 2019-03-21



2. TEST DESCRIPTION
               Test Item                       Section in CFR 47             Result       Test Engineer
         Antenna requirement                         15.203                   PASS        Xiaokang Tan
 AC Power Line Conducted Emissions                   15.207                    N/A             N/A
 Field Strength of the Fundamental and
                                                 15.225(a)(b)(c)               N/A             N/A
           Mask Measurement
            20dB Bandwidth                           15.215                   PASS         Michael Jie
          Radiated Emission                    15.225(d)&15.209               PASS        Xiaokang Tan
          Frequency Stability                      15.225(e)                  PASS         Shower Dai




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                     Page 5 of 23                    Issued: 2019-03-21



3. SUMMARY
3.1. Client Information
Applicant:                   Kirisun Communication Co.,Ltd.

                             3rd Floor, Building A, Tongfang Information Habour, No.11 Langshan Road,
Address:
                             Nanshan District, Shenzhen 518057, P.R.China

Manufacturer:                Kirisun Communication Co.,Ltd.

                             3rd Floor, Building A, Tongfang Information Habour, No.11 Langshan Road,
Address:
                             Nanshan District, Shenzhen 518057, P.R.China

3.2. Product Description
Name of EUT:                 PoC Trunked Mobile Radio

Trade Mark:                  KIRISUN

Model No.:                   M50

Listed Model(s):             iTALK 450

Power supply:                DC 12V

RF Specification

Operation frequency:         13.56MHz

Channel number:              1

Modulation Type:             ASK




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                     Page 6 of 23                   Issued: 2019-03-21

3.3. EUT operation mode
TEST MODE
 For RF test items
 The engineering test program was provided and enabled to make EUT continuous transmit.
 For AC power line conducted emissions:
 The EUT was set to connect with large package sizes transmission.


3.4. EUT configuration
The following peripheral devices and interface cables were connected during the measurement:
● - supplied by the manufacturer
○ - supplied by the lab

                                            Manufacturer : /
                                              Model No. : /
                                            Manufacturer : /
                                              Model No. : /




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                          Page 7 of 23                        Issued: 2019-03-21



4. TEST ENVIRONMENT
4.1. Address of the test laboratory
Laboratory: Shenzhen Huatongwei International Inspection Co., Ltd.
Address: 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China
Phone: 86-755-26748019 Fax: 86-755-26748089
4.2. Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

CNAS-Lab Code: L1225

Shenzhen Huatongwei International Inspection Co., Ltd. has been assessed and proved to be in compliance
with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025:
2005 General Requirements) for the Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No. 3902.01

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing.

FCC-Registration No.: 762235

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from
the FCC is maintained in our files. Registration 762235.

IC-Registration No.: 5377B-1

Two 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No. 5377B-1.

ACA

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory can also perform testing for the
Australian C-Tick mark as a result of our A2LA accreditation.




Shenzhen Huatongwei International Inspection Co., Ltd.                   Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                       Page 8 of 23                      Issued: 2019-03-21



4.3. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:                                         15~35°C
Relative Humidity:                                       30~60 %
Air Pressure:                                            950~1050mba

4.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors in calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report according to TR-100028-01 “Electromagnetic
compatibility and Radio spectrum Matters (ERM);Uncertainties in the measurement of mobile radio
equipment characteristics;Part 1” and TR-100028-02 “Electromagnetic compatibility and Radio spectrum
Matters (ERM);Uncertainties in the measurementof mobile radio equipment characteristics;Part 2” and is
documented in the Shenzhen Huatongwei International Inspection Co., Ltd quality system according to
ISO/IEC 17025. Further more, component and process variability of devices similar to that tested may result
in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device.

Here after the best measurement capability for Shenzhen Huatongwei is reported:

                      Test Items                           Measurement Uncertainty             Notes
Conducted Disturbance 9KHz-30MHz                                     3.35 dB                     (1)
Radiated emissions below 1GHz                                        4.28 dB                     (1)
Radiated emissions above 1GHz                                        5.16 dB                     (1)
Occupied Bandwidth                                                    18 Hz                      (1)
(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
    level using a coverage factor of k=1.96.




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                         Page 9 of 23                   Issued: 2019-03-21

4.5. Equipments Used during the Test
●      Conducted Emission
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)

 ●     Shielded Room         Albatross projects        N/A             N/A        2018/09/28       2023/09/27

 ●     EMI Test Receiver           R&S                 ESCI          101247       2018/10/27       2019/10/26

 ●     Artificial Mains      SCHWARZBECK            NNLK 8121          573        2018/10/27       2019/10/26

 ●     Pulse Limiter               R&S               ESH3-Z2         100499       2018/10/27       2019/10/26

 ●     RF Connection Cable   HUBER+SUHNER             EF400            N/A        2018/11/15       2019/11/14

 ●     Test Software               R&S                ES-K1            N/A            N/A              N/A
       Single Balanced
 ○                                 FCC            FCC-TLISN-T2-02    20371        2018/10/28       2019/10/27
       Telecom Pair ISN
       Two Balanced
 ○                                 FCC            FCC-TLISN-T4-02    20373        2018/10/28       2019/10/27
       Telecom Pairs ISN
       Four Balanced
 ○                                 FCC            FCC-TLISN-T8-02    20375        2018/10/28       2019/10/27
       Telecom Pairs ISN
 ○     V-Network                   R&S               ESH3-Z6         100211       2018/10/27       2019/10/26

 ○     V-Network                   R&S               ESH3-Z6         100210       2018/10/27       2019/10/26

 ○     2-Line V-Network            R&S               ESH3-Z5         100049       2018/10/27       2019/10/26


 ●     Radiated Emission-6th test site
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)
       Semi-Anechoic
 ●                           Albatross projects     SAC-3m-02          N/A        2018/09/30       2021/09/29
       Chamber
 ●     EMI Test Receiver           R&S                 ESCI          100900       2018/10/28       2019/10/27

 ○     Loop Antenna                R&S               HFH2-Z2         100020       2017/11/20       2020/11/19
       Ultra-Broadband
 ●                           SCHWARZBECK             VULB9163          546        2017/04/05       2020/04/04
       Antenna
 ●     Pre-Amplifer          SCHWARZBECK             BBV 9742          N/A        2018/11/15       2019/11/14

 ●     RF Connection Cable   HUBER+SUHNER              N/A             N/A        2018/09/28       2019/09/27
 ●     RF Connection Cable   HUBER+SUHNER          SUCOFLEX104      501184/4      2018/09/28       2019/09/27
 ●     Test Software               R&S                ES-K1            N/A            N/A              N/A

 ●     Turntable             Maturo Germany          TT2.0-1T          N/A            N/A              N/A

 ●     Antenna Mast          Maturo Germany        CAM-4.0-P-12        N/A            N/A              N/A


 ●     Radiated emission-7th test site
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)
       Semi-Anechoic
 ●                           Albatross projects     SAC-3m-01          N/A        2018/09/30       2021/09/29
       Chamber
 ●     Spectrum Analyzer           R&S                FSP40          100597       2018/10/27       2019/10/26

 ●     Horn Antenna          SCHWARZBECK              9120D           1011        2017/03/27       2020/03/26

 ○     Pre-amplifier              BONN             BLWA0160-2M      1811887       2018/11/14       2019/11/13

 ●     Pre-amplifier                CD               PAP-0102        12004        2018/11/14       2019/11/13
       Broadband Pre-
 ●                           SCHWARZBECK             BBV 9718       9718-248      2018/04/28       2019/04/27
       amplifier
 ●     RF Connection Cable   HUBER+SUHNER            RE-7-FH           N/A        2018/11/15       2019/11/14

 ●     RF Connection Cable   HUBER+SUHNER             RE-7-FL          N/A        2018/11/15       2019/11/14

 ●     Test Software               Audix                E3             N/A            N/A              N/A

 ●     Turntable             Maturo Germany          TT2.0-1T          N/A            N/A              N/A

 ●     Antenna Mast          Maturo Germany        CAM-4.0-P-12        N/A            N/A              N/A

Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                     Page 10 of 23                    Issued: 2019-03-21


 ●     RF Conducted Method
                                                                               Last Cal. Date   Next Cal. Date
Used      Test Equipment     Manufacturer         Model No.       Serial No.
                                                                               (YY-MM-DD)        (YY-MM-DD)
       Signal and spectrum
 ●                               R&S               FSV40           100048       2018/10/28       2019/10/27
       Analyzer
 ○     Spectrum Analyzer        Agilent            N9020A        MY50510187     2018/09/29       2019/09/28
       Radio communication
 ○                               R&S              CMW500          137688-Lv     2018/09/29       2019/09/28
       tester
 ○     Test software          Tonscend          JS1120-1(LTE)        N/A            N/A              N/A

 ○     Test software          Tonscend          JS1120-2(WIFI)       N/A            N/A              N/A

 ○     Test software          Tonscend        JS1120-3(WCDMA)        N/A            N/A              N/A

 ○     Test software          Tonscend         JS1120-4(GSM)         N/A            N/A              N/A




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                       Page 11 of 23                      Issued: 2019-03-21



5. TEST CONDITIONS AND RESULTS
5.1. Antenna requirement
Requirement
FCC CFR Title 47 Part 15 Subpart C Section 15.203:
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of anantenna
that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken
antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is
prohibited.

Refer to statement below for compliance.
The manufacturer may design the unit so that the user can replace a broken antenna, but the use of a
standard antenna jack or electrical connector is prohibited. Further, this requirement does not apply to
intentional radiators that must be professionally installed.

TEST RESULTS

   Passed               Not Applicable

The directional gain of the antenna less than 6 dBi, please refer to the below antenna photo.




Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                      Page 12 of 23                    Issued: 2019-03-21



5.2. AC Power Conducted Emissions
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.207:
                                                                      Limit (dBuV)
          Frequency range (MHz)
                                                      Quasi-peak                        Average
                  0.15-0.5                             66 to 56*                        56 to 46*
                    0.5-5                                 56                               46
                    5-30                                  60                               50
* Decreases with the logarithm of the frequency.

TEST CONFIGURATION




TEST PROCEDURE

1. The EUT was setup according to ANSI C63.10:2013
2. The EUT was placed on a plat form of nominal size, 1 m by 1.5 m, raised 80 cm above the conducting
   ground plane. The vertical conducting plane was located 40 cm to the rear of the EUT. All other surfaces
   of EUT were at least 80 cm from any other grounded conducting surface.
3. The EUT and simulators are connected to the main power through a line impedance stabilization
   network (LISN). The LISN provides a 50ohm / 50uH coupling impedance for the measuring equipment.
4. The peripheral devices are also connected to the main power through a LISN. (Please refer to the block
   diagram of the test setup and photographs)
5. Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor,was
   individually connected through a LISN to the input power source.
6. The excess length of the power cord between the EUT and the LISN receptacle were folded back and
   forth at the center of the lead to form a bundle not exceeding 40 cm in length.
7. Conducted emissions were investigated over the frequency range from 0.15MHz to 30MHz using a
   receiver bandwidth of 9 kHz.
8. During the above scans, the emissions were maximized by cable manipulation.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                        Page 13 of 23                     Issued: 2019-03-21



5.3. Field Strength of the Fundamental and Mask Measurement
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.225(a)(b)(c)
                                    Field strength of fundamental              Field strength of fundamental
  Fundamental frequency(MHz)
                                            (uV/m @30m)                               (dBuV/m @3m)
            13.553-13.567                            15848                                 124.0
     13.410-13.553&13.567-13.710                      334                                  90.5
     13.110-13.410&13.710-14.010                      106                                  80.5

Note: Limit dBuV/m @3m =Limit dBuV/m @30m +40*log(30/3)= Limit dBuV/m @30m + 40.
TEST CONFIGURATION




TEST PROCEDURE

1.     The EUT was setup and tested according to ANSI C63.10:2013 requirements.
2.     The EUT is placed on a turn table which is 0.8 meter above ground. The turn table is rotated 360 degrees
       to determine the position of the maximum emission level.
3.     The EUT waspositioned such that the distance from antenna to the EUT was 3 meters.
4.     The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. Thisis
       repeated for both horizontal and vertical polarization of the antenna. In order to find the maximum
       emission, all of the interface cables were manipulated according to ANSI C63.10:2013 on radiated
       measurement.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

     Passed              Not Applicable




Shenzhen Huatongwei International Inspection Co., Ltd.               Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                     Page 14 of 23                     Issued: 2019-03-21


                               Field Strength of The Fundamental and Mask




     Frequency(MHz)          QuasiPeak(dBuV/m)                Limit(dBuV/m)             Test Result
          13.35                    38.86                          80.50                   Pass
          13.52                    41.09                          90.50                   Pass
          13.56                    61.01                         124.00                   Pass
          13.61                    39.79                          90.50                   Pass
          13.77                    35.23                          80.50                   Pass




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                      Page 15 of 23                     Issued: 2019-03-21



5.4. 20dB Bandwidth
Limit
FCC CFR Title 47 Part 15 Subpart C Section 15.215
Intentional radiators must be designed to ensure that the 20dB emission bandwidth in the specific band
13.553~13.567MHz.

TEST CONFIGURATION




TEST PROCEDURE
1. The transmitter output was connected to the spectrum analyzer through an attenuator, the path loss was
   compensated to the results for each measurement.
2. Set to the maximum power setting and enable the EUT transmit continuously
3. Use the following spectrum analyzer settings:
   Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping channel
   RBW ≥ 1% of the 20 dB bandwidth, VBW ≥ RBW
   Sweep = auto, Detector function = peak, Trace = max hold
4. Measure and record the results in the test report.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                     Page 16 of 23                Issued: 2019-03-21


               20dB Bandwidth(kHz):                                       4.848




                                                              fL>13.553
     Frequency Range (MHz)
                                                              fH<13.567




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                     Page 17 of 23                     Issued: 2019-03-21



5.5. Radiated Emission
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.209&15.225(d)
Limit for frequency below 30MHz:
                                              Measurement
         Frequency            Limit (uV/m)                             Remark
                                               Distance(m)
        0.009~0.490          2400/F(kHz)                 300         Quasi-peak
        0.490~1.705         24000/F(kHz)                 30          Quasi-peak
        1.705~30.0                30                     30          Quasi-peak
Note: Limit dBuV/m @3m = Limit dBuV/m @300m + 40*log(300/3)= Limit dBuV/m @300m +80,
Limit dBuV/m @3m = Limit dBuV/m @30m +40*log(30/3)= Limit dBuV/m @30m + 40.

Limit for frequency above 30MHz:
         Frequency          Limit (dBuV/m@3m)            Remark
     30MHz~88MHz                   40.00             Quasi-peak
    88MHz~216MHz                   43.50             Quasi-peak
    216MHz~960MHz                  46.00             Quasi-peak
     960MHz-1GHz                   54.00             Quasi-peak
                                   54.00                 Average
        Above 1GHz
                                   74.00                  Peak


TEST CONFIGURATION
   9 kHz ~ 30 MHz




   30 MHz ~ 1 GHz




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                         Page 18 of 23                       Issued: 2019-03-21

     Above 1 GHz




TEST PROCEDURE
1.    The EUT was setup and tested according to ANSI C63.10:2013 requirements.
2.    The EUT is placed on a turn table which is 0.8 meter above ground for below 1 GHz, and 1.5 m for above
      1 GHz. The turn table is rotated 360 degrees to determine the position of the maximum emission level.
3.    The EUT was set 3 meters from the receiving antenna, which was mounted on the top of a variable
      height antenna tower.
4.    For each suspected emission, the EUT was arranged to its worst case and then tune the Antenna tower
      (from 1 m to 4 m) and turntable (from 0 degree to 360 degrees) to find the maximum reading. A pre-amp
      and a high pass filter are used for the test in order to get better signal level to comply with the guidelines.
5.    Set to the maximum power setting and enable the EUT transmit continuously.
6.    Use the following spectrum analyzer settings
      (1) Span shall wide enough to fully capture the emission being measured;
      (2) Below 30MHz:
          RBW=10 kHz, VBW=30 kHz, Sweep=auto, Detector function=peak, Trace=max hold;
      (3) 30MHz to 1 GHz:
          RBW=120 kHz, VBW=300 kHz, Sweep=auto, Detector function=peak, Trace=max hold;
          If the emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit,
          the peak emission level will be reported. Otherwise, the emission measurement will be repeated
          using the quasi-peak detector and reported.
                             th
      (4) From 1 GHz to 10 harmonic:
          RBW=1MHz, VBW=3MHz Peak detector for Peak value.
          RBW=1MHz, VBW=3MHz RMS detector for Average value.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

     Passed              Not Applicable




Shenzhen Huatongwei International Inspection Co., Ltd.                  Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                     Page 19 of 23                 Issued: 2019-03-21

Below 30MHz:




  Frequency(MHz)           QuasiPeak(dBuV/m)             Limit(dBuV/m)              Test Result
        0.02                     46.58                      122.11                    Pass
        0.04                     43.11                      115.13                    Pass
        0.24                     44.82                       96.40                    Pass
        0.45                     44.93                       85.56                    Pass
        0.95                     42.21                       68.08                    Pass
       13.56                     54.15                         N/A                     N/A




Shenzhen Huatongwei International Inspection Co., Ltd.          Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                     Page 20 of 23                       Issued: 2019-03-21

Above 30MHz:
Polarization:                                            Vertical




Polarization:                                            Horizontal




Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Repor No CHEwrovsota7                        Page 21 o23                      lesved: 2010.08—21

56. Frequency Stability
umt
The requency falerance ofthe carlr signal shallbe maintained wthin £0.019%of the oporating frequency
over a temperature variation of 20 degrees to + 50 dagrees C atntmal sipply valtage, and for a vartion in
the primany supply vatage ram 89% to 115%of e rated supply vatage ata temperatue of 20 degrees C
For batery operated eaulpment,the equlpment testsshllbe perfarmed using a now battery
Test conricuration




Test pnocenure
1. The equipment under test was connected to an extemal power supply
2.. RF output was connected to a fequiency counteror spactrum analyzer va feed through atenators
8. The EUT was placed inslde the temperature chamber
a Set e spectuum analyzer RBW low enough to obtainthe desed frequaney resoliton and measure EUT
    257 eperating frequency as reference requency
5. Tum EUT off and setthe chambe tempratureto ~20t. Atorthe termperatirestalized for
    «pproximately 20 minites recarded the frequency.
.. Repeat stop mensure wit 10 Iereased per tage untl he highesttemporature of +50°C reached
Test wooe
Please refet he clause 38
rest nesuuts
[ Passed           [ Not Applicable

       imemenm                Fewoer                     Feqrey
    Valage Temperslire(G)—]_ Reading(Mi)                  Em                  Un               l
                  zo           Tesos                     nomor              oom                 Pass
                  o            Tesoor                    n.o05%             Foome               Pass
                    o          Tesooor                   n.o05%             xoom:               Pass
                   To          Teseoos                   .0007%             Foome               Pass
  norz oov        zo           Taseos                    n.o00%             *oome               Pass
                  s            Taseos                    o.0007%            *oome               Pass
                  4            Tescore                   0.0000%            *oome               Pass
                   so          Tascors                   s.oou1%            *oome               Pass
  sozsooy         zo           Teseoor                   n.o05%             *oome               Pass
  bapem           zo           Taseos                    o.0007%            *ooms               Pass



Shenehen Hratongwel hformational nspectin Go, Lid                 Recor Template Version: VaT (2018—00


Report No : CHTEW19030147                     Page 22 of 23               Issued: 2019-03-21



6. TEST SETUP PHOTOS OF THE EUT
Radiated Emissions




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : CHTEW19030147                     Page 23 of 23                 Issued: 2019-03-21

7. EXTERNAL AND INTERNAL PHOTOS OF THE EUT

    Reference to the test report No.: CHTEW19030141




                                        --------End of Report--------