SAR report part 3

FCC ID: Q5EDSJ-M9

RF Exposure Info

Download: PDF
FCCID_4344410

                               Appendix A: SAR Test Data Plots

Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab     Date: 6/12/2019

GSM 850-Body

Communication System: UID 0, Generic GPRS(TDMA, GMSK, TN 0-1-2) (0); Frequency: 824.2
MHz;Duty Cycle: 1:2.66993
Medium parameters used: f = 825 MHz; σ = 0.964 S/m; εr = 55.449; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.2℃;Liquid Temperature:21.9℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(10.46, 10.46, 10.46) @ 824.2 MHz; Calibrated: 3/25/2019
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 3/19/2019
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Rear/CH 128/Area Scan (61x101x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.471 W/kg

Rear/CH 128/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 22.13 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 0.544 W/kg
SAR(1 g) = 0.370 W/kg; SAR(10 g) = 0.272 W/kg
Maximum value of SAR (measured) = 0.472 W/kg




              0 dB = 0.472 W/kg = -3.26 dBW/kg




                                                                                Plot No.14


                                 Appendix A: SAR Test Data Plots

Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 6/14/2019

GSM 1900-Body

Communication System: UID 0, Generic GPRS(TDMA, GMSK, TN 0-1-2) (0); Frequency: 1850.2
MHz;Duty Cycle: 1:2.66993
Medium parameters used (interpolated): f = 1850.2 MHz; σ = 1.517 S/m; εr = 53.775; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.1℃;Liquid Temperature:21.9℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8.38, 8.38, 8.38) @ 1850.2 MHz; Calibrated: 3/25/2019
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 3/19/2019
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Rear/CH 512/Area Scan (61x101x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 0.355 W/kg

Rear/CH 512/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 8.363 V/m; Power Drift = -0.12 dB
Peak SAR (extrapolated) = 0.423 W/kg
SAR(1 g) = 0.241 W/kg; SAR(10 g) = 0.144 W/kg

Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.350 W/kg




               0 dB = 0.350 W/kg = -4.56 dBW/kg




                                                                                       Plot No.15


                                Appendix A: SAR Test Data Plots

Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 6/14/2019

WCDMA Band II-Body

Communication System: UID 0, Generic UMTS (0); Frequency: 1907.6 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 1907.6 MHz; σ = 1.557 S/m; εr = 53.715; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.3℃;Liquid Temperature:22.0℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8.38, 8.38, 8.38) @ 1907.6 MHz; Calibrated: 3/25/2019
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 3/19/2019
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Rear/CH 9538/Area Scan (61x101x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 0.348 W/kg

Rear/CH 9538/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 6.919 V/m; Power Drift = 0.05 dB
Peak SAR (extrapolated) = 0.407 W/kg
SAR(1 g) = 0.236 W/kg; SAR(10 g) = 0.142 W/kg

Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.338 W/kg




              0 dB = 0.338 W/kg = -4.71 dBW/kg



                                                                                     Plot No.16


                                Appendix A: SAR Test Data Plots

Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 6/13/2019

WCDMA Band IV-Body

Communication System: UID 0, Generic UMTS (0); Frequency: 1752.6 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 1752.6 MHz; σ = 1.444 S/m; εr = 53.892; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.1℃;Liquid Temperature:21.9℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8.51, 8.51, 8.51) @ 1752.6 MHz; Calibrated: 3/25/2019
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 3/19/2019
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Front/CH 1513/Area Scan (61x101x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 0.910 W/kg

Front/CH 1513/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 13.54 V/m; Power Drift = -0.10 dB
Peak SAR (extrapolated) = 1.04 W/kg
SAR(1 g) = 0.604 W/kg; SAR(10 g) = 0.380 W/kg

Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.862 W/kg




              0 dB = 0.862 W/kg = -0.64 dBW/kg



                                                                                     Plot No.17


                                Appendix A: SAR Test Data Plots

Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 6/12/2019

WCDMA Band V-Body

Communication System: UID 0, Generic UMTS (0); Frequency: 826.4 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 826.4 MHz; σ = 0.964 S/m; εr = 55.439; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.2℃;Liquid Temperature:21.9℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(10.46, 10.46, 10.46) @ 826.4 MHz; Calibrated: 3/25/2019
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 3/19/2019
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Rear/CH 4132/Area Scan (61x101x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 0.213 W/kg

Rear/CH 4132/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 15.06 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 0.237 W/kg
SAR(1 g) = 0.161 W/kg; SAR(10 g) = 0.119 W/kg

Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.206 W/kg




              0 dB = 0.206 W/kg = -6.86 dBW/kg


                                                                                   Plot No.18


                               Appendix A: SAR Test Data Plots

Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab     Date: 6/14/2019

LTE Band 2-Body

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 1860 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1860 MHz; σ = 1.524 S/m; εr = 53.764; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:21.9℃;Liquid Temperature:21.7℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8.38, 8.38, 8.38) @ 1860 MHz; Calibrated: 3/25/2019
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 3/19/2019
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Rear/CH 18700/Area Scan (61x101x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.242 W/kg

Rear/CH 18700/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 5.770 V/m; Power Drift = -0.14 dB
Peak SAR (extrapolated) = 0.275 W/kg
SAR(1 g) = 0.157 W/kg; SAR(10 g) = 0.095 W/kg
Maximum value of SAR (measured) = 0.227 W/kg




              0 dB = 0.227 W/kg = -6.44 dBW/kg




                                                                                Plot No.19


                               Appendix A: SAR Test Data Plots

Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab     Date: 6/13/2019

LTE Band 4-Body

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 1745 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1745 MHz; σ = 1.434 S/m; εr = 53.883; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.1℃;Liquid Temperature:21.9℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8.51, 8.51, 8.51) @ 1745 MHz; Calibrated: 3/25/2019
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 3/19/2019
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Rear/CH 20300/Area Scan (61x101x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.106 W/kg

Rear/CH 20300/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 4.562 V/m; Power Drift = 0.07 dB
Peak SAR (extrapolated) = 0.124 W/kg
SAR(1 g) = 0.070 W/kg; SAR(10 g) = 0.044 W/kg
Maximum value of SAR (measured) = 0.102 W/kg




              0 dB = 0.102 W/kg = -9.91 dBW/kg




                                                                                Plot No.20


                                Appendix A: SAR Test Data Plots

Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 6/12/2019

LTE Band 5-Body

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 836.5 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.5 MHz; σ = 0.967 S/m; εr = 55.399; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.1℃;Liquid Temperature:21.8℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(10.46, 10.46, 10.46) @ 836.5 MHz; Calibrated: 3/25/2019
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 3/19/2019
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Rear/CH 20525/Area Scan (61x101x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 0.125 W/kg

Rear/CH 20525/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 11.32 V/m; Power Drift = -0.07 dB
Peak SAR (extrapolated) = 0.144 W/kg
SAR(1 g) = 0.097 W/kg; SAR(10 g) = 0.071 W/kg

Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.124 W/kg




              0 dB = 0.124 W/kg = -9.07 dBW/kg



                                                                                     Plot No.21


                               Appendix A: SAR Test Data Plots

Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab     Date: 6/19/2019

LTE Band 7-Body

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 2560 MHz;Duty Cycle: 1:1
Medium parameters used: f = 2560 MHz; σ = 2.109 S/m; εr = 52.848; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.2℃;Liquid Temperature:22.0℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(7.69, 7.69, 7.69) @ 2560 MHz; Calibrated: 3/25/2019
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 3/19/2019
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Rear/CH 21300/Area Scan (81x131x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 0.981 W/kg

Rear/CH 21300/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 0.7110 V/m; Power Drift = 0.13 dB
Peak SAR (extrapolated) = 1.19 W/kg
SAR(1 g) = 0.625 W/kg; SAR(10 g) = 0.340 W/kg
Maximum value of SAR (measured) = 0.952 W/kg




              0 dB = 0.952 W/kg = -0.21 dBW/kg




                                                                                Plot No.22


                                Appendix A: SAR Test Data Plots

Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 6/17/2019

LTE Band 12-Body

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 704 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 704 MHz; σ = 0.917 S/m; εr = 55.746; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:21.8℃;Liquid Temperature:21.5℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(10.81, 10.81, 10.81) @ 704 MHz; Calibrated: 3/25/2019
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 3/19/2019
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Rear/CH 23060/Area Scan (61x101x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 0.00713 W/kg

Rear/CH 23060/Zoom Scan (6x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 2.065 V/m; Power Drift = -0.18 dB
Peak SAR (extrapolated) = 0.00769 W/kg
SAR(1 g) = 0.00477 W/kg; SAR(10 g) = 0.00359 W/kg

Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.00637 W/kg




              0 dB = 0.00637 W/kg = -21.96 dBW/kg



                                                                                     Plot No.23


                               Appendix A: SAR Test Data Plots

Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab     Date: 6/17/2019

LTE Band 17-Body

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 710 MHz;Duty Cycle: 1:1
Medium parameters used: f = 710 MHz; σ = 0.919 S/m; εr = 55.736; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:21.9℃;Liquid Temperature:21.7℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(10.81, 10.81, 10.81) @ 710 MHz; Calibrated: 3/25/2019
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 3/19/2019
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Rear/CH 23790/Area Scan (61x101x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.00551 W/kg

Rear/CH 23790/Zoom Scan (6x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 1.811 V/m; Power Drift = -0.11 dB
Peak SAR (extrapolated) = 0.00571 W/kg
SAR(1 g) = 0.00344 W/kg; SAR(10 g) = 0.00264 W/kg
Maximum value of SAR (measured) = 0.00466 W/kg




             0 dB = 0.00466 W/kg = -23.32 dBW/kg




                                                                                Plot No.24


                               Appendix A: SAR Test Data Plots

Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab     Date: 6/19/2019

LTE Band 41-Body

Communication System: UID 0, Generic LTE-TDD (0); Frequency: 2645 MHz;Duty Cycle:
1:1.57979
Medium parameters used: f = 2645 MHz; σ = 2.192 S/m; εr = 52.705; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.0℃;Liquid Temperature:21.8℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(7.69, 7.69, 7.69) @ 2645 MHz; Calibrated: 3/25/2019
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 3/19/2019
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Rear/CH 41140/Area Scan (81x131x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 0.332 W/kg

Rear/CH 41140/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 5.658 V/m; Power Drift = -0.03 dB
Peak SAR (extrapolated) = 0.407 W/kg
SAR(1 g) = 0.209 W/kg; SAR(10 g) = 0.112 W/kg
Maximum value of SAR (measured) = 0.325 W/kg




              0 dB = 0.325 W/kg = -4.88 dBW/kg




                                                                                Plot No.25


                                Appendix A: SAR Test Data Plots

Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab       Date: 6/18/2019

WiFi 2.4G-Body

Communication System: UID 0, Generic WIFI (0); Frequency: 2437 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 2437 MHz; σ = 1.991 S/m; εr = 53.023; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.9℃;Liquid Temperature:21.7℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8, 8, 8) @ 2437 MHz; Calibrated: 3/25/2019
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 3/19/2019
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Front/CH 6/Area Scan (81x131x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (interpolated) = 0.0101 W/kg

Front/CH 6/Zoom Scan (8x8x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 1.550 V/m; Power Drift = 0.17 dB
Peak SAR (extrapolated) = 0.0140 W/kg
SAR(1 g) = 0.0036 W/kg; SAR(10 g) = 0.00133 W/kg

Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.00758 W/kg




             0 dB = 0.00758 W/kg = -21.20 dBW/kg


                                                                                   Plot No.26