User manual

FCC ID: Q3K-5XACULC

Users Manual

Download: PDF
FCCID_3223483

SU Pro, SU Air
Outdoor Subscriber Radio Unit

REFERENCE GUIDE


                                    Regulatory Compliance

    FCC/IC - Compliance
    This equipment has been tested and found to comply with the limits for a Class B digital device,
    pursuant to Part 15 of the FCC Rules and IC RSS standards. These limits are designed to provide
    reasonable protection against harmful interference in a residential installation. This equipment
    generates uses and can radiate radio frequency energy and, if not installed and used in
    accordance with the instructions, may cause harmful interference to radio communications.
    However, there is no guarantee that interference will not occur in a particular installation. If this
    equipment does cause harmful interference to radio or television reception, which can be
    determined by turning the equipment off and on, the user is encouraged to try to correct the
    interference by one or more of the following measures:
          • Reorient or relocate the receiving antenna.
          • Increase the separation between the equipment and receiver.
          • Connect the equipment into an outlet on a circuit different from that to which
            the receiver is connected.
    Consult the dealer or an experienced radio/TV technician for help.
    Changes or modifications to this equipment not expressly approved by the party
    responsible for compliance could void the user's authority to operate the equipment.


                       It is the responsibility of the installer to ensure that when using the outdoor
                       antenna kits, only those antennas certified with the product are used. The use
                       of any antenna other than those certified with the product is expressly
                       forbidden by FCC 47 CFR Part 15.204 and IC RSS standards.
    Warning
                       Il est de la responsabilité de l'installateur de s'assurer que lorsque vous
                       utilisez les kits d'antennes extérieures, seules les antennes certifiés avec le
                       produit sont utilisés. L'utilisation d'une antenne autre que ceux qui sont
Avertissement          certifiés avec le produit est expressément interdite par la réglementation FCC
                       partie 47 CFR 15.204 et IC normes RSS.



                      Outdoor units and antennas should be installed ONLY by experienced
                      installation professionals who are familiar with local building and safety codes
                      and, wherever applicable, are licensed by the appropriate government
                      regulatory authorities. Failure to do so may void the product warranty and
                      may expose the end user or the service provider to legal and financial
        Caution       liabilities. Resellers or distributors of this equipment are not liable for injury,
                      damage or violation of regulations associated with the installation of outdoor
                      units or antennas. The installer should configure the output power level of
                      antennas according to country regulations and antenna type.




    SU Pro, SU Air Reference Guide                                                                      i


                   Les unités extérieures et les antennes doivent être installés que par des
                   professionnels expérimentés d'installation qui sont familiers avec les normes
                   locales et les codes de sécurité et, si applicable, sont agréées par les autorités
                   gouvernementales de réglementation compétents. Ne pas le faire peut annuler
                   la garantie du produit et peuvent exposer l'utilisateur final ou le fournisseur de
   Prudence        services          d'obligations          juridiques         et          financiers.
                   Revendeurs ou distributeurs de ces équipements ne sont pas responsables des
                   blessures, des dommages ou violation des règlements liés à l'installation des
                   unités extérieures ou des antennes. L'installateur doit configurer le niveau de
                   puissance de sortie des antennes conformément aux réglementations
                   nationales et le type d'antenne.



                  This equipment should be installed and operated with a minimum distance of
                  50cm between the radiator and your body.
     Warning


                   Cet équipement doit être installé et utilisé à une distance minimale de 50cm
                   entre le radiateur et votre corps.
Avertissement



                  The module is granted to operate under FCC Rules in the 2.4 / 4.9 / 5.4 /
                  5.8 GHz bands.
     Warning




  This device complies with Part 15 of the FCC rules and with Industry Canada license-
  exempt RSS standard(s). Operation is subject to the following two conditions:
  (1) This device may not cause harmful interference.
  (2) This device must accept any interference received, including interference that may
  cause undesired operation.


  Cet appareil est conforme la norme d'Industrie Canada exempts de licence RSS (s). Son
  fonctionnement est soumis aux deux conditions suivantes:
  1. Cet appareil ne peut pas causer d'interférences, et
  2. Cet appareil doit accepter toute interférence, y compris les interférences qui peuvent
  causer un mauvais fonctionnement de l'appareil.

  This Class B digital apparatus complies with Canadian ICES-003.
  Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada

  SU Pro, SU Air Reference Guide                                                                    ii


Overview
The ‘SU Pro, SU Air’ is an Outdoor Subscriber Radio Unit operating in the 4.9 – 5.8 GHz
frequency bands. It is a TDD OFDM radio supporting 10 MHz, 20 MHz, 40 MHz and 80 MHz
channel bandwidths. The 2.4 GHz WiFi interface supports standard 802.11/n HT-20, HT-40
operation modes.
It supports cross polarized 2x2 MIMO antenna configuration for PtP and PtMP systems. The
‘SU Pro, SU Air’ also features an on-board WiFi 2.4 GHz interface module for short range
control purposes. The ‘SU Pro, SU Air’ is powered by a 24Vdc PoE device.
The ‘SU Pro, SU Air’ is certified with the FCC ID: Q3K-5XACULC and IC: 5100A- 5XACULC.


Condition of Use
The ‘SU Pro, SU Air’ is a proprietary radio device and can only be deployed and maintained
by RADWIN professional installers or its authorized subcontractors


FCC rules and IC Regulation Restrictions
The ODU firmware is factory programmed to operate under the FCC rules and Industry
Canada regulation restrictions. The firmware is locked and inaccessible by any third party.
As a result of the above the user interface allows both the installer and the user to control
the ODU only within the boundaries of the regional restrictions.


Antennas
The ‘SU Pro, SU Air’ is certified with a 17 dBi integrated flat crossed dual pole antenna type
covering both Point-to-Point and Point-to-Multipoint systems.



Certified Antenna
Following are the antennas certified for use with the ‘SU Pro, SU Air’:


                                           Model           Frequency          Antenna Max
 Antenna Type        Manufacturer
                                          Number             Range             Gain (dBi)
                                                           4940-4990                14

    Dual Pole                                              5150-5350                16
                      RADWIN Ltd.       MP0188280
    Integrated                                             5470-5725                17

                                                           5725-5850                16

      Omni            RADWIN Ltd.        On-Board         2400-2483.5               3


SU Pro, SU Air Reference Guide                                                              1


Maximum Output Power
5725 – 5850 MHz band - FCC/IC
The maximum output power can be set as follows, when operating in the 5.8 GHz band,
under FCC 47 CFR Part 15.407 New Rules and IC RSS-247 regulations. The power values
are for PtP systems and PtMP systems. For PtMP systems the total EIRP is limited to 36
dBm. Therefore the output power of these systems will be reduced to comply with 36 dBm
EIRP limit.
The highest conducted output power shall be limited to 29 dBm in all channel bandwidths


4940 – 4990 MHz band - FCC/IC
The maximum output power can be set as follows, when operating in the 4.9 GHz band,
under FCC 47 CFR Part 90Y Rule and IC RSS-111 regulations.

10 MHz: 21.0 dBm
20 MHz: 21.0 dBm


5150 – 5250 MHz band – FCC
The maximum output power can be set as follows when transmitting in the 5.1 GHz band,
under FCC 47 CFR Part 15.407 New Rules and regulations.
The total EIRP limit for PtP applications is 45 dBm.
The total EIRP limit for PtMP applications is 36 dBm.
The total EIRP limit for PtMP applications when transmitting at elevations above 30° relative
to the horizon is 21 dBm.

10   MHz:   26.0   dBm
20   MHz:   28.0   dBm
40   MHz:   28.0   dBm
80   MHz:   29.0   dBm


2400 – 2483.5 MHz band - FCC/IC
The maximum output power can be set as follows, when operating in the 2.4 GHz band,
under FCC 47 CFR Part 15.247 and IC RSS-247 regulations. The power values are for Wi-Fi
systems for HT-20 and HT-40 Channel BW.
The highest conducted output power shall be limited to 26 dBm in all channel bandwidths


5250 – 5350 MHz band – FCC/IC
The maximum output power can be set as follows, when operating in the 5.3 GHz band. The
total EIRP limit is 30 dBm.

10   MHz:   11.0   dBm
20   MHz:   14.0   dBm
40   MHz:   14.0   dBm
80   MHz:   14.0   dBm




SU Pro, SU Air Reference Guide                                                           2


5470 – 5725 MHz band – FCC/IC
The maximum output power can be set as follows, when operating in the 5.4 GHz band. The
total EIRP limit is 30 dBm.

10   MHz:   10.0   dBm
20   MHz:   13.0   dBm
40   MHz:   13.0   dBm
80   MHz:   13.0   dBm




                         Channel Bandwidths and Frequency Range


                         Channel BW             Center Freq. Range
                           [MHz]                      [MHz]
                             10                     5730 - 5845
                             20                     5735 - 5840
                             40                     5745 - 5825
                             80                     5765 - 5810
                             10                     4945 - 4985
                             20                     4950 - 4980
                             10                     5160 - 5245
                             20                     5165 - 5240
                             40                     5170 - 5230
                             80                     5190 - 5210
                             20                     2412 - 2462
                             40                     2422 - 2452
                             10                     5255 - 5340
                             20                     5260 - 5340
                             40                     5270 - 5330
                             80                     5290 - 5310
                             10                     5480 - 5715
                             20                     5485 - 5710
                             40                     5495 - 5700
                             80                     5520 - 5680




Radio parameters accessed by end-user

The following parameters can be accessed by user:

     1. Output Power
     2. Frequency channel
     3. Channel bandwidth




SU Pro, SU Air Reference Guide                                                     3



Document Created: 2016-12-07 18:10:05
Document Modified: 2016-12-07 18:10:05

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC