MPE

FCC ID: Q3K-5XACMOD

RF Exposure Info

Download: PDF
FCCID_2526355

RDWN34-U10 MPE                  Maximum Permissible Exposure


FCC, Part 15 §1.1310


Calculations for Maximum Permissible Exposure Levels
Power Density = Pd (mW/cm2) = EIRP/(4d2)
EIRP = P * G
P = Peak output power (mW)
G = Antenna numeric gain (numeric)
d = Separation distance (cm)
Numeric Gain = 10 ^ (G (dBi)/10)
Because the EUT belongs to the General Population/Uncontrolled Exposure the limit of
power density is 1.0 mW/cm2

The calculations in the table below use highest gain antennas for the client EUT. Where the
antenna gain exceeds 6dBi the transmitter power is reduced where necessary to meet the
EIRP requirements. These calculations represent worst case in terms of the exposure levels.


Worst case results for each antenna type
                                                                          Calculated
                                                      Peak        Peak                       Power
                                 Ant     Numeric                             Safe
    Antenna                                          Output      Output                    Density @
                      Type      Gain      Gain                            Distance @
     Model                                           Power       Power                       20cm
                                (dBi)   (numeric)                          1mW/cm2
                                                     (dBm)        (mW)                     (mW/cm2)
                                                                          Limit (cm)
                     Sector
                   Dual Pole
   MT0128930                     11       12.59          24.85   305.49     17.49            0.77
                   Integrated
                    120 Deg
                     Sector
                   Dual Pole
   AM0135060                     12       15.85          23.94   247.74     17.68            0.78
                   Integrated
                     95 Deg
                   Shark Fin
 RW-9401-5002                   11.5*     14.13          24.44   277.97     17.68            0.78
                   Monopole
                     Sector
 RW-9061-5002      Dual Pole    14.5*     28.18          23.4    218.78     22.15            1.23
                     60 Deg
                   Flat Panel
   AM0111760       Dual Pole     16       39.81          26.94   494.31     39.57            3.91
                   Integrated
                   Flat Panel
   MT0070760       Dual Pole    23.5      223.87         26.94   494.31     93.84            22.02
                   Integrated
                   Flat Panel
 RW-9622-5001      Dual Pole     28*      630.96         24.94   311.89     125.14           39.15
                    External
                   Dual Pole
 RW-9732-4958                    31*     1258.93         21.94   156.31     125.14           39.15
                      Dish

* Gain includes 1 dB feeder loss for external antennas

Note: for mobile or fixed location transmitters the minimum separation distance is 20cm,
even if calculations indicate the MPE distance to be less.

Specification
Maximum Permissible Exposure Limits

 FCC §1.1310 Limit = 1mW / cm2 from 1.310 Table 1
 Ref FCC KDB 447498 General RF Exposure Guidance

 RSS-Gen §5.6 Category I and Category II equipment shall comply with the applicable
 requirements of RSS-102.

Laboratory Measurement Uncertainty for Power Measurements
 Measurement uncertainty                 1.33 dB