                                           FCC PART 15.247
                                               TEST REPORT
                                                              For

                                        Summer Infant, Inc.
                      1275 Park East Drive, Woonsocket, Rhode Island, United States



                                            FCC ID: PZK-956AT


              Report Type:                                       Product Type:
              Original Report                                    Baby Monitor



                      Test Engineer:         Haiguo Li


                    Report Number:           RSZ160519003-00A


                        Report Date:         2016-05-30

                                             Bell Hu
                       Reviewed By:          RF Engineer

                        Prepared By:         Bay Area Compliance Laboratories Corp. (Shenzhen)
                                             6/F, the 3rd Phase of WanLi Industrial Building
                                             ShiHua Road, FuTian Free Trade Zone
                                             Shenzhen, Guangdong, China
                                             Tel: +86-755-33320018
                                             Fax: +86-755-33320008
                                             www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the equipment described herein. It may not be duplicated
or used in part without prior written consent from Bay Area Compliance Laboratories Corp.


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                                            Report No.: RSZ160519003-00A




                                                        TABLE OF CONTENTS


GENERAL INFORMATION .......................................................................................................................................4
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................4
 OBJECTIVE ...................................................................................................................................................................4
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................4
 TEST METHODOLOGY ..................................................................................................................................................4
 TEST FACILITY .............................................................................................................................................................5
SYSTEM TEST CONFIGURATION ..........................................................................................................................6
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................6
  EQUIPMENT MODIFICATIONS .......................................................................................................................................6
  EUT EXERCISE SOFTWARE ..........................................................................................................................................6
  SUPPORTED EQUIPMENT ...............................................................................................................................................6
  EXTERNAL I/O CABLE..................................................................................................................................................7
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................7
SUMMARY OF TEST RESULTS ...............................................................................................................................8
FCC §15.247 (i) & §1.1310 & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE).........................................9
  APPLICABLE STANDARD ..............................................................................................................................................9
  RESULT ........................................................................................................................................................................9
FCC §15.203 - ANTENNA REQUIREMENT...........................................................................................................10
  APPLICABLE STANDARD ............................................................................................................................................10
  ANTENNA CONNECTOR CONSTRUCTION ....................................................................................................................10
FCC §15.207 (a) – AC LINE CONDUCTED EMISSIONS .....................................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  MEASUREMENT UNCERTAINTY ..................................................................................................................................11
  EUT SETUP ................................................................................................................................................................11
  EMI TEST RECEIVER SETUP .......................................................................................................................................12
  TEST PROCEDURE ......................................................................................................................................................12
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................12
  CORRECTED FACTOR & MARGIN CALCULATION .......................................................................................................12
  TEST RESULTS SUMMARY ..........................................................................................................................................13
  TEST DATA ................................................................................................................................................................13
FCC §15.209, §15.205 & §15.247(d) - SPURIOUS EMISSIONS.............................................................................16
  APPLICABLE STANDARD ............................................................................................................................................16
  MEASUREMENT UNCERTAINTY ..................................................................................................................................16
  EUT SETUP ................................................................................................................................................................16
  EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP ..............................................................................................17
  TEST PROCEDURE ......................................................................................................................................................17
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................18
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................18
  TEST RESULTS SUMMARY ..........................................................................................................................................19
  TEST DATA ................................................................................................................................................................19
FCC §15.247(a) (2) – 6 dB EMISSION BANDWIDTH ............................................................................................21
  APPLICABLE STANDARD ............................................................................................................................................21
  TEST PROCEDURE ......................................................................................................................................................21
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................21
  TEST DATA ................................................................................................................................................................21

FCC Part 15.247                                                                                                                                          Page 2 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                                         Report No.: RSZ160519003-00A


FCC §15.247(b) (3) - MAXIMUM CONDUCTED OUTPUT POWER ..................................................................24
  APPLICABLE STANDARD ............................................................................................................................................24
  TEST PROCEDURE ......................................................................................................................................................24
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................24
  TEST DATA ................................................................................................................................................................25
FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE .......................................................26
  APPLICABLE STANDARD ............................................................................................................................................26
  TEST PROCEDURE ......................................................................................................................................................26
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................26
  TEST DATA ................................................................................................................................................................27
FCC §15.247(e) - POWER SPECTRAL DENSITY .................................................................................................29
  APPLICABLE STANDARD ............................................................................................................................................29
  TEST PROCEDURE ......................................................................................................................................................29
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................29
  TEST DATA ................................................................................................................................................................30




FCC Part 15.247                                                                                                                                       Page 3 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ160519003-00A

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)
The Summer Infant, Inc.’s product, model number: 29560A(FCC ID: PZK-956AT) in this report is a Baby
Monitor, which includes a Baby Monitor, The baby unit was measured approximately: 8.4 cm (L) x 8.7cm
(W) x 5.9 cm (H), rated with input voltage: DC4.8V Ni-MH battery or 7.5V from adapter.

Adapter Information:
Model: P6 0750500
Input: AC 100~240V, 50~ 60 Hz, 250 mA
Output: DC 7.5V, 500 mA

* All measurement and test data in this report was gathered from production sample serial number: 1602299.
(Assigned by BACL, Shenzhen). The EUT supplied by the applicant was received on 2016-05-19.


Objective
This report is prepared on behalf of Summer Infant, Inc. in accordance with Part 2-Subpart J, Part 15-
Subparts A, B and C of the Federal Communication Commission’s rules.

The tests were performed in order to determine compliance with FCC Part 15, Subpart C, and section
15.203, 15.205, 15.207, 15.209 and 15.247 rules.


Related Submittal(s)/Grant(s)
N/A


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.

All emissions measurement was performed at Bay Area Compliance Laboratories Corp. (Shenzhen). The
radiated testing was performed at an antenna-to-EUT distance of 3 meters.

Measurement uncertainty with RF radiated emission is 5.81 dB for 30MHz-1GHz and 4.88 dB for above
1GHz, 1.95dB for conducted measurement.




FCC Part 15.247                                                                                   Page 4 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: RSZ160519003-00A

Test Facility
The test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located on
the 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen,
Guangdong, China.

Test site at Bay Area Compliance Laboratories Corp. (Shenzhen) has been fully described in reports
submitted to the Federal Communication Commission (FCC). The details of these reports have been found
to be in compliance with the requirements of Section 2.948 of the FCC Rules on October 31, 2013. The
facility also complies with the radiated and AC line conducted test site criteria set forth in ANSI C63.10-
2013.

The Federal Communications Commission has the reports on file and is listed under FCC Registration No.:
382179. The test site has been approved by the FCC for public use and is listed in the FCC Public Access
Link (PAL) database.




FCC Part 15.247                                                                             Page 5 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                      Report No.: RSZ160519003-00A

SYSTEM TEST CONFIGURATION
Description of Test Configuration
For 802.11g, 11 channels are provided to test:

                                                                             Frequency
                  Channel          Frequency (MHz)           Channel
                                                                               (MHz)
                     1                    2412                  8               2447
                     2                    2417                  9               2452
                     3                    2422                 10               2457
                     4                    2427                 11               2462
                     5                    2432                  /                 /
                     6                    2437                  /                 /
                     7                    2442                  /                /

For 802.11g mode, EUT was tested with Channel 1, 6 and 11.

EUT was tested under default setting with 100% duty cycle.

Equipment Modifications
No modification was made to the EUT tested.

EUT Exercise Software
“LivCam V1.0.1” provided by the manufacturer.

Supported equipment

          Manufacturer                Description            Model            Serial Number

               N/A                    Mobile phone            N/A                    N/A




FCC Part 15.247                                                                          Page 6 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ160519003-00A

External I/O Cable

                  Cable Description                   Length (m)         From Port                   To

      Un-Shielding Un-Detachable DC Cable                    2.0           EUT                     Adapter


Block Diagram of Test Setup
For conducted emission

                                                                         Adapter
                                                                                                    LISN


                                      Mobile phone                 EUT
                                                                          10cm



                                                                          Receptacle




              Non-Conductive Table                                                     1.0 Meter
              80 cm above Ground Plane

                                                1.5 Meters




FCC Part 15.247                                                                                    Page 7 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ160519003-00A

SUMMARY OF TEST RESULTS


                  FCC Rules                           Description of Test                Result

       §15.247 (i),1.1310& §2.1091                      RF Exposure                    Compliance

                   §15.203                          Antenna Requirement                Compliance

                  §15.207 (a)                AC Line Conducted Emissions               Compliance
            §15.205, §15.209,
                                                     Spurious Emissions                Compliance
               §15.247(d)
              §15.247 (a)(2)                   6 dB Emission Bandwidth                 Compliance

              §15.247(b)(3)                Maximum Conducted Output Power              Compliance

                  §15.247(d)           100 kHz Bandwidth of Frequency Band Edge        Compliance

                  §15.247(e)                        Power Spectral Density             Compliance




FCC Part 15.247                                                                             Page 8 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ160519003-00A

FCC §15.247 (i) & §1.1310 & §2.1091- MAXIMUM PERMISSIBLE
EXPOSURE (MPE)
Applicable Standard
According to subpart 15.247 (i) and subpart 1.1310, 2.1091 systems operating under the provisions of this
section shall be operated in a manner that ensures the public is not exposed to RF energy level in excess of
the communication guidelines.

                                Limits for General Population/Uncontrolled Exposure

                               Limits for General Population/Uncontrolled Exposure
             Frequency           Electric Field     Magnetic Field        Power           Averaging
               Range                Strength           Strength          Density            Time
               (MHz)                 (V/m)              (A/m)           (mW/cm2)          (Minutes)
               0.3-1.34                 614              1.63           *(100)                  30
               1.34-30               824/f              2.19/f         *(180/f2)                30
                30-300                  27.5            0.073               0.2                 30
               300-1500                  /                /             f/1500                  30
           1500-100,000                  /                /                 1.0                 30

f = frequency in MHz
* = Plane-wave equivalent power density

Result
Calculated Formulary:

Predication of MPE limit at a given distance

                                                         PG
                                                   S=
                                                        4R 2
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW).
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
    factor, is normally numeric gain.
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)


                                               Maximum tune –up    Evaluation          Power
   Frequency              Antenna Gain                                                                MPE Limit
                                                Conducted Power     Distance          Density
     (MHz)                                                                                            (mW/cm2)
                    (dBi)       (numeric)      (dBm)      (mW)       (cm)            (mW/cm2)
   2412-2462          0             1          15.00     31.62         20               0.006              1

Note: To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm
from nearby persons.

Result: Compliance




FCC Part 15.247                                                                                      Page 9 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ160519003-00A

FCC §15.203 - ANTENNA REQUIREMENT
Applicable Standard
According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
furnished by the responsible party shall be used with the device. The use of a permanently attached
antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered
sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a
broken antenna can be replaced by the user, but the user of a standard antenna jack or electrical connector
is prohibited. The structure and application of the EUT were analyzed to determine compliance with
section §15.203 of the rules. §15.203 state that the subject device must meet the following criteria:

a. Antenna must be permanently attached to the unit.
b. Antenna must use a unique type of connector to attach to the EUT.
Unit must be professionally installed, and installer shall be responsible for verifying that the correct
antenna is employed with the unit.
And according to FCC 47 CFR section 15.247 (b), if the transmitting antennas of directional gain greater
than 6dBi are used, the power shall be reduced by the amount in dB that the directional gain of the antenna
exceeds 6 dBi.


Antenna Connector Construction
The EUT has a PCB antenna arrangement, which was permanently attached and the antenna gain is
0 dBi, fulfill the requirement of this section. Please refer to the EUT photos.


Result: Compliance.




FCC Part 15.247                                                                              Page 10 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                                   Report No.: RSZ160519003—00A.


FCC §15.207 (a)— AC LINE CONDUCTED EMISSIONS

Applicable Standard

FCC§15.207


Measurement Uncertainty

Input quantities to be considered for conducted disturbance measurements maybe receiver reading,
attenuation of the connection between LISN and receiver, LISN voltage division factor, LISN VDF
frequency interpolation and receiver related input quantities, etc.

Based on CISPR 16—4—2:2011, the expended combined standard uncertainty of conducted disturbancetest
at Bay Area Compliance Laboratories Corp. (Shenzhen) is shown as below. And the uncertainty will not
be takeninto consideration for the test data recorded in the report.

                             Port                              Expanded Measurement uncertainty

                           AC Mains                            3.34 dB (k=2, 95% level of confidence)
                            CAT3                               3.72 dB (k=2, 95% level of confidence)
                            CAT S                              3.74 dB (k=2, 95% level of confidence)
                            CAT 6                              4.54 dB (k=2, 95% level of confidence)



EUT Setup

                              ... Vertical Reference
                                  Ground Plane                                          Test Receiver


                  * 40 em |                                                         /
                                      Eut                                        lz|5ces
                                                                                     a pa0
                                  N
                                                        BOcm




                                  uiss       P
                      >\                          1                             1
                                                                        N
                              ~
                                      Bonded to Horizontal            Horizontal Reference
                                      Ground Plane                    Ground Plane

                    Note: 1. Supp ort units were connected to second LISN.
                          2. Both of LISNs (AMN) 80 cm from EUT and at the least 80 cm
                                  from other units and other metal planes support units.

The setup of EUT is according with per ANSI C63.10—2013 measurement procedure. The specification
used was with the FCC Part 15.207 limits.

The spacing between the peripherals was 10 cm.

FCC Part 15.247                                                                                         Page 11 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                                Report No.: RSZ160519003-00A

EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                                Frequency Range                         IF B/W
                               150 kHz – 30 MHz                          9 kHz



Test Procedure
During the conducted emission test, the adapter was connected to the outlet of the LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All final data was recorded in the Quasi-peak and average detection mode.


Test Equipment List and Details

                                                                                   Calibration    Calibration
    Manufacturer            Description            Model        Serial Number
                                                                                      Date         Due Date
       Schwarz           EMI Test Receiver          ESCI           101122          2015-06-03      2016-06-02
                                                                3560.6650.12-
   Rohde & Schwarz             LISN               ENV216                           2015-12-01      2016-12-01
                                                                 101613-Yb
   Rohde & Schwarz       Transient limitator      ESH3Z2          DE25985          2016-05-14      2017-05-13
   Rohde & Schwarz       CE Test software         EMC 32            V8.53             NCR             NCR
       Ducommun         Conducted Emission
                                                  RG-214            CB031          2015-06-15      2016-06-15
      technologies            Cable

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed in accordance to requirements that traceable to National Primary Standards and International System
of Units (SI).


Corrected Factor & Margin Calculation
The Corrected factor is calculated by adding LISN VDF (Voltage Division Factor), Cable Loss and
Transient Limiter Attenuation. The basic equation is as follows:

      Correction Factor = LISN VDF + Cable Loss + Transient Limiter Attenuation

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:

      Margin = Limit – Corrected Amplitude




FCC Part 15.247                                                                                   Page 12 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ160519003-00A

Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.207, the worst
margin reading as below:

                          11.1dB at 0.348690MHz in the Neutral conducted mode

Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level complies with the limit if

                                            Lm + U(Lm) ≤ Llim + Ucispr

In BACL, U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.


Test Data
     Environmental Conditions

              Temperature:               25 ℃
        Relative Humidity:               56 %
            ATM Pressure:              101.0 kPa

     The testing was performed by Haiguo Li on 2016-05-26.

     Test Mode: Charging & Communication




FCC Part 15.247                                                                                   Page 13 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                                            Report No.: RSZ160519003-00A

     AC 120 V, 60 Hz, Line:

                                                            EMI Auto Test L


                          90

                          80

                          70
                                                                                                              QP
                          60
                                                                                                              AV
           Level in dBμ




                          50

                          40

                          30

                          20

                          10

                          0
                          150k    300   400 500   800 1M           2M     3M     4M 5M 6     8 10M     20M    30M
                                                              Frequency in Hz


                                 Corrected        Correction
         Frequency                                                       Limit             Margin      Detector
                                 Amplitude         Factor
           (MHz)                                                        (dBμV)              (dB)     (PK/QP/Ave.)
                                  (dBμV)            (dB)
          0.229500                  43.2             20.0                62.5               19.3             QP
          0.253500                 41.8              19.9                61.6               19.8             QP
          0.278501                 40.3              19.9                60.9               20.6             QP
          0.344750                 40.4              19.9                59.1               18.7             QP
          0.368450                 36.7              19.9                58.5               21.8             QP
          1.073650                 32.0              20.0                56.0               24.0             QP
          0.229500                 39.2              20.0                52.5               13.3         Ave.
          0.253500                 36.8              19.9                51.6               14.8         Ave.
          0.278501                 36.0              19.9                50.9               14.8         Ave.
          0.344750                 35.4              19.9                49.1               13.7         Ave.
          0.368450                 31.2              19.9                48.5               17.3         Ave.
          1.073650                 27.5              20.0                46.0               18.5         Ave.




FCC Part 15.247                                                                                               Page 14 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                                         Report No.: RSZ160519003-00A


     AC 120V, 60 Hz, Neutral:

                                                          EMI Auto Test N


                          90

                          80

                          70
                                                                                                           QP
                          60
                                                                                                           AV
           Level in dBμ




                          50

                          40

                          30

                          20

                          10

                          0
                          150k   300   400 500   800 1M          2M     3M     4M 5M 6    8 10M      20M    30M
                                                            Frequency in Hz



                                 Corrected       Correction
         Frequency                                                     Limit         Margin         Detector
                                 Amplitude        Factor
           (MHz)                                                      (dBμV)          (dB)        (PK/QP/Ave.)
                                  (dBμV)           (dB)
          0.205500                 44.0             20.0               63.4              19.4          QP
          0.249500                 41.9             20.0               61.8              19.9          QP
          0.301500                 42.7             19.9               60.2              17.5          QP
          0.348690                 42.2             19.9               59.0              16.8          QP
          0.348810                 42.6             19.9               59.0              16.4          QP
          1.042130                 35.2             20.0               56.0              20.8          QP
          0.205500                 39.7             20.0               53.4              13.7         Ave.
          0.249500                 36.9             20.0               51.8              14.9         Ave.
          0.301500                 37.9             19.9               50.2              12.3         Ave.
          0.348690                 37.9             19.9               49.0              11.1         Ave.
          0.348810                 37.8             19.9               49.0              11.2         Ave.
          1.042130                 28.8             20.0               46.0              17.2         Ave.

Note:
1) Corrected Amplitude = Reading + Correction Factor
2) Correction Factor =LISN VDF (Voltage Division Factor) + Cable Loss
3) Margin = Limit – Corrected Amplitude




FCC Part 15.247                                                                                            Page 15 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                             Report No.: RSZ160519003—00A


FCC §15.209, §15.205 & §15.247(d) — SPURIOUS EMISSIONS

Applicable Standard

FCC §15.247 (d); §15.209; §15.205;

Measurement Uncertainty

All measurements involve certain levels of uncertainties, especially in field of EMC. The factors
contributing to uncertainties are spectrum analyzer, cable loss, antennafactor calibration, antenna
directivity, antenna factor variation with height, antenna phase center variation, antenna factor frequency
interpolation, measurement distance variation, site imperfections, mismatch (average), and system
repeatability.

Based on CISPR 16—4—2:2011, the expended combined standard uncertainty ofradiation emissions at Bay
Area Compliance Laboratories Corp. (Shenzhen) is 5.81 dB for 30MHz—1GHz and 4.88 dB for above
1GHz, 1.95dB for conducted measurementat antenna port. And the uncertainty will not be taken into
consideration for the test data recorded in the report


EUT Setup

Below 1 GHz:

                                                             Ant. Tow             Ldm
                                                                                  Nariable
               EUT&                                                          /
               Support Units

                                        Turn Table

                  0.8m I

                                                    1
                                            Ground Plane

                                            Test R&czivqr\
                                                             %          E__3
                                                                 *l PmX o 0 o o
                                                                          a o e




FCC Part 15.247                                                                               Page 16 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                             Report No.: RSZ160519003-00A


Above 1GHz:




The radiated emission tests were performed in the 3 meters test site, using the setup accordance with the
ANSI C63.10-2013. The specification used was the FCC 15.209, and FCC 15.247 limits.


EMI Test Receiver & Spectrum Analyzer Setup
The system was investigated from 30 MHz to 25 GHz.

During the radiated emission test, the EMI test receiver & Spectrum Analyzer Setup were set with the
following configurations:

          Frequency Range            RBW            Video B/W          IF B/W           Detector

         30 MHz – 1000 MHz          100 kHz           300 kHz          120 kHz             QP
                                     1MHz             3 MHz               /                PK
            Above 1 GHz
                                     1MHz              10 Hz              /               Ave.


Test Procedure
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

Data was recorded in Quasi-peak detection mode for frequency range of 30 MHz-1 GHz, peak and
Average detection modes for frequencies above 1 GHz.




FCC Part 15.247                                                                              Page 17 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ160519003-00A

Test Equipment List and Details

                                                                      Serial        Calibration    Calibration
    Manufacturer             Description             Model
                                                                     Number            Date         Due Date
          HP                 Amplifier            HP8447E          1937A01046       2016-05-06      2017-05-06
  Rohde & Schwarz        EMI Test Receiver          ESCI             101120         2015-12-15      2016-12-14
    Sunol Sciences        Bi-log Antenna             JB1            A040904-2       2014-12-07      2017-12-06
         Mini                Amplifier          ZVA-183-S+         5969001149       2016-04-23      2017-04-23
     A.H. System           Horn Antenna         SAS-200/571            135          2015-08-18      2018-08-17
  Rohde & Schwarz         Signal Analyzer          FSIQ26          8386001028       2015-12-11      2016-12-11
    the electro-
                           Horn Antenna             3116            9510-2270       2013-10-14      2016-10-13
   Mechanics Co.
       TDK                   Chamber             Chamber A              2#          2013-10-15      2016-10-15
         TDK                 Chamber             Chamber B              1#          2015-07-23      2016-07-22
                                                   ALN-
    DUCOMMUN               Pre-amplifier                            991373-01       2015-08-03      2016-08-03
                                                22093530-01
         R&S             Auto test Software       EMC32              V9.10             NCR             NCR
      Ducommun                                  UFA210A-1-         MFR64369
                             RF Cable                                               2015-06-15      2016-06-15
     technologies                               4724-30050U        223410-001
      Ducommun
                             RF Cable              104PEA           218124002       2015-06-15      2016-06-15
     technologies
      Ducommun
                             RF Cable              RG-214               1           2015-06-15      2016-06-15
     technologies
      Ducommun
                             RF Cable              RG-214               2           2015-06-15      2016-06-15
     technologies

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed in accordance to requirements that traceable to National Primary Standards and International System
of Units (SI).


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit – Corrected Amplitude




FCC Part 15.247                                                                                    Page 18 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ160519003-00A

Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Title 47, Part 15,
Subpart C, section 15.205, 15.209 and 15.247.

                  4.62dB at 2483.59 MHz in the Horizontal polarization for High Channel

Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level complies with the limit if

                                            Lm + U(Lm) ≤ Llim + Ucispr

In BACL, U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.


Test Data
     Environmental Conditions

              Temperature:               25 ℃
        Relative Humidity:               56 %
             ATM Pressure:             101.0 kPa

     The testing was performed by Haiguo Li on 2016-05-26.

Test Mode: Transmitting

                                                                                FCC Part
                       Receiver      Turn   Rx Antenna Corrected Corrected
 Frequency                                                                    15.247/205/209
                                     table              Factor Amplitude
   (MHz)        Reading  Detector   Degree Height Polar  (dB)    (dBμV/m)    Limit     Margin
                (dBμV) (PK/QP/Ave.)         (m) (H/V)                      (dBμV/m)      (dB)
                                            Low Channel(2412MHz)
    183.51         47.66       QP           118    1.6     H     -14.9            32.76       43.5       10.79
     2412         106.89       PK            92    1.7     H     -6.46           100.43         /          /
     2412          95.98       Ave.          92    1.7     H     -6.46            89.52         /          /
     2412         104.63       PK           220    1.2     V     -6.46            98.17         /          /
     2412          94.11       Ave.         220    1.2     V     -6.46            87.65         /          /
   2388.47         64.81       PK             9    1.4     H     -6.46            58.35        74        15.65
   2388.47         49.92       Ave.           9    1.4     H     -6.46           43.46         54        10.54
   2389.33         66.18       PK            17    2.3     H     -6.46            59.72        74        14.28
   2389.33         50.17       Ave.          17    2.3     H     -6.46           43.71         54        10.29
   2499.37         49.65       PK           338    1.8     H     -4.74            44.91        74        29.09
   2499.37         35.24       Ave.         338    1.8     H     -4.74           30.50         54        23.50
     4824          42.53       PK           313     2      V      3.79            46.32        74        27.68
     4824          28.61       Ave.         313     2      V      3.79            32.40        54        21.60
     7236          42.12       PK           198     2      V      9.79            51.91        74        22.09
     7236          27.34       Ave.         198     2      V      9.79            37.13        54        16.87
     9648          41.35       PK           145    1.7     V     11.85            53.20        74        20.80
     9648          27.12       Ave.         145    1.7     V     11.85            38.97        54        15.03




FCC Part 15.247                                                                                   Page 19 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                        Report No.: RSZ160519003-00A

                                                                                FCC Part
                       Receiver      Turn   Rx Antenna Corrected Corrected
 Frequency                                                                    15.247/205/209
                                     table              Factor Amplitude
   (MHz)        Reading  Detector   Degree Height Polar  (dB)    (dBμV/m)    Limit     Margin
                (dBμV) (PK/QP/Ave.)         (m) (H/V)                      (dBμV/m)      (dB)
                                          Middle Channel(2437MHz)
    183.54         47.62       QP          158     1.4     H     -14.9    32.72      43.5      10.78
     2437         106.29       PK           30     2.4     H     -6.46    99.83        /         /
     2437          96.75       Ave.         30     2.4     H     -6.46    90.29        /         /
     2437         105.49       PK           29     2.2     V     -6.46    99.03        /         /
     2437          95.63       Ave.         29     2.2     V     -6.46    89.17        /         /
   2388.95         54.54       PK           78     1.4     H     -6.46    48.08       74       25.92
   2388.95         40.12       Ave.         78     1.4     H     -6.46    33.66       54       20.34
   2389.11         55.26       PK            0     1.9     H     -6.46     48.8       74       25.20
   2389.11         42.31       Ave.          0     1.9     H     -6.46    35.85       54       18.15
   2492.29         50.29       PK          277     2.1     H     -4.74    45.55       74       28.45
   2492.29         35.98       Ave.        277     2.1     H     -4.74    31.24       54       22.76
     4874          43.41       PK          302     2.2     V      3.56    46.97       74       27.03
     4874          29.27       Ave.        302     2.2     V      3.56    32.83       54       21.17
     7311          42.35       PK           87     2.5     V    10.11     52.46       74       21.54
     7311          29.74       Ave.         87     2.5     V    10.11     39.85       54       14.15
     9748          41.24       PK           51     1.3     V    11.85     53.09       74       20.91
     9748          27.56       Ave.         51     1.3     V    11.85     39.41       54       14.59
                                          High Channel(2462MHz)
    183.54         45.33       QP          178     1.4     H     -14.9    30.43      43.5      13.07
     2462         108.95       PK          345     1.1     H     -4.74   104.21        /          /
     2462          99.02       Ave.        345     1.1     H     -4.74    94.28        /          /
     2462         104.68       PK          305     1.5     V     -4.74    99.94        /          /
     2462          95.63       Ave.        305     1.5     V     -4.74    90.89        /          /
   2384.86         49.45       PK          109     1.3     H     -6.46    42.99       74       31.01
   2384.86         33.48       Ave.        109     1.3     H     -6.46   27.02        54       26.98
   2483.59         70.96       PK          192     1.4     H     -4.74    66.22       74        7.78
   2483.59         54.12       Ave.        192     1.4     H     -4.74   49.38        54        4.62
   2483.86         67.87       PK          253     1.7     H     -4.74    63.13       74       10.87
   2483.86         49.02       Ave.        253     1.7     H     -4.74   44.28        54        9.72
     4924          43.88       PK          157     2.2     V      3.56    47.44       74       26.56
     4924          29.46       Ave.        157     2.2     V      3.56    33.02       54       20.98
     7386          42.57       PK           86      1      V      8.17    50.74       74       23.26
     7386          28.37       Ave.         86      1      V      8.17    36.54       54       17.46
     9848          41.68       PK           19     1.7     V    13.21     54.89       74       19.11
     9848          27.31       Ave.         19     1.7     V    13.21     40.52       54       13.48

Note:
Corrected Factor = Antenna factor (RX) + Cable Loss – Amplifier Factor
Corrected Amplitude = Corrected Factor + Reading
Margin = Limit - Corrected. Amplitude




FCC Part 15.247                                                                         Page 20 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                                  Report No.: RSZ160519003-00A


FCC §15.247(a) (2) – 6 dB EMISSION BANDWIDTH
Applicable Standard
Systems using digital modulation techniques may operate in the 902–928 MHz, 2400–2483.5 MHz, and
5725–5850 MHz bands. The minimum 6 dB bandwidth shall be at least 500 kHz.


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect it to
   measurement instrument. Then set it to any one convenient frequency within its operating range. Set a
   reference level on the measuring instrument equal to the highest peak value.
3. Measure the frequency difference of two frequencies that were attenuated 6 dB from the reference
   level. Record the frequency difference as the emission bandwidth.
4. Repeat above procedures until all frequencies measured were complete.



                                                              Signal Analyzer
                     EUT                    Attenuator


Test Equipment List and Details

                                                                                     Calibration   Calibration
     Manufacturer              Description            Model        Serial Number
                                                                                        Date        Due Date
    Rohde & Schwarz          Signal Analyzer          FSIQ26         8386001028      2015-12-11    2016-12-11
       Ducommun
                                 RF Cable             RG-214              3          2015-06-15    2016-06-15
      technologies
     WEINSCHEL               10dB Attenuator           5324            AU0709        2015-06-18    2016-06-18

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed in accordance to requirements that traceable to National Primary Standards and International System
of Units (SI).

Test Data
     Environmental Conditions

              Temperature:                  26 ℃
        Relative Humidity:                  56 %
            ATM Pressure:                101.0 kPa

     The testing was performed by Haiguo Li on 2016-05-24.

     Test Result: Pass.
     Please refer to the following table and plots.



FCC Part 15.247                                                                                    Page 21 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                             Report No.: RSZ160519003-00A

    EUT operation mode: Transmitting

                                                              6 dB Emission
                                            Frequency                                  Limit
              Channel                                           Bandwidth
                                              (MHz)                                    (kHz)
                                                                  (MHz)
                   Low                        2412                 15.50               ≥500
                  Middle                      2437                 16.41               ≥500
                  High                        2462                 15.76               ≥500

                                                     Low Channel




             Date: 24.MAY.2016   17:26:25




FCC Part 15.247                                                                                Page 22 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)             Report No.: RSZ160519003-00A

                                             Middle Channel




             Date: 24.MAY.2016   17:56:11




                                              High Channel




             Date: 24.MAY.2016   18:08:41




FCC Part 15.247                                                              Page 23 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ160519003-00A

FCC §15.247(b) (3) - MAXIMUM CONDUCTED OUTPUT POWER
Applicable Standard
According to FCC §15.247(b) (3), for systems using digital modulation in the 902-928 MHz, 2400-2483.5
MHz, and 5725-5850 MHz bands: 1 Watt. As an alternative to a peak power measurement, compliance
with the one Watt limit can be based on a measurement of the maximum conducted output power.
Maximum Conducted Output Power is defined as the total transmit power delivered to all antennas and
antenna elements averaged across all symbols in the signaling alphabet when the transmitter is operating at
its maximum power control level. Power must be summed across all antennas and antenna elements. The
average must not include any time intervals during which the transmitter is off or is transmitting at a
reduced power level. If multiple modes of operation are possible (e.g., alternative modulation methods),
the maximum conducted output power is the highest total transmit power occurring in any mode.


Test Procedure

1. Place the EUT on a bench and set it in transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to one
    test equipment.
3. Add a correction factor to the display.


                                                           Power Meter
                  EUT                     Attenuator



Test Equipment List and Details

                                                                                 Calibration      Calibration
    Manufacturer           Description            Model        Serial Number
                                                                                    Date           Due Date
          HP               Power Meter           N1912A         MY5000448         2015-12-18      2016-12-17

          HP               Power Sensor          N1921A         MY54210016        2015-12-18      2016-12-17

     WEINSCHEL           10dB Attenuator          5324            AU0709          2015-06-18      2016-06-18

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed in accordance to requirements that traceable to National Primary Standards and International System
of Units (SI).




FCC Part 15.247                                                                                   Page 24 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                        Report No.: RSZ160519003-00A

Test Data
     Environmental Conditions

             Temperature:                26 ℃
        Relative Humidity:               56 %
            ATM Pressure:             101.0 kPa

     The testing was performed by Haiguo Li on 2016-05-24.

    EUT operation mode: Transmitting

                                                  Max Conducted   Max Conducted
                             Frequency             Peak Output    Average Output         Limit
      Channel
                               (MHz)                  Power           Power              (dBm)
                                                      (dBm)           (dBm)
        Low                    2412                    18.07           14.46               30
       Middle                  2437                    18.52           14.58               30
       High                    2462                    17.61           13.53               30




FCC Part 15.247                                                                         Page 25 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ160519003-00A


FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE
Applicable Standard
In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated
intentional radiator is operating, the radio frequency power that is produced by the intentional radiator
shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level
of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter
demonstrates compliance with the peak conducted power limits. If the transmitter complies with the
conducted power limits based on the use of RMS averaging over a time interval, as permitted under
paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20
dB. Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated
emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated
emission limits specified in §15.209(a) (see §15.205(c)).


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect its
   antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured
   frequency within its operating range, and make sure the instrument is operated in its linear range.
3. Set RBW to 100 kHz and VBW of spectrum analyzer to 300 kHz with a convenient frequency span
   including 100 kHz bandwidth from band edge.
4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the
   graph with marking the highest point and edge frequency.
5. Repeat above procedures until all measured frequencies were complete.


                                                             Signal Analyzer
                     EUT                  Attenuator


Test Equipment List and Details

                                                                   Serial         Calibration     Calibration
     Manufacturer           Description           Model
                                                                  Number             Date          Due Date
    Rohde & Schwarz        Signal Analyzer       FSIQ26          8386001028       2015-12-11      2016-12-11
       Ducommun
                              RF Cable           RG-214               3           2015-06-15      2016-06-15
      technologies
     WEINSCHEL             10dB Attenuator         5324            AU0709         2015-06-18      2016-06-18

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed in accordance to requirements that traceable to National Primary Standards and International System
of Units (SI).




FCC Part 15.247                                                                                   Page 26 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                         Report No.: RSZ160519003-00A

Test Data
     Environmental Conditions

              Temperature:                     26 ℃
        Relative Humidity:                      56 %
            ATM Pressure:                     101.0 kPa

     The testing was performed by Haiguo Li 2016-05-24

     EUT operation mode: Transmitting

     Test Result: Compliance

     Please refer to the following plots.

                                                   Band Edge, Left Side




               Date: 24.MAY.2016   17:33:32




FCC Part 15.247                                                                          Page 27 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                   Report No.: RSZ160519003-00A



                                            Band Edge, Right Side




             Date: 24.MAY.2016   18:14:58




FCC Part 15.247                                                                    Page 28 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ160519003-00A

FCC §15.247(e) - POWER SPECTRAL DENSITY
Applicable Standard
For digitally modulated systems, the power spectral density conducted from the intentional radiator to the
antenna shall not be greater than 8 dBm in any 3 kHz band during any time interval of continuous
transmission. This power spectral density shall be determined in accordance with the provisions of
paragraph (b) of this section. The same method of determining the conducted output power shall be used to
determine the power spectral density.

Test Procedure
1.  Use this procedure when the maximum peak conducted output power in the fundamental emission is
    used to demonstrate compliance.
2. Set the RBW to: 3kHz≤ RBW≤100 kHz.
3. Set the VBW ≥ 3×RBW.
4. Set the span to 1.5 times the DTS bandwidth.
5. Detector = peak.
6. Sweep time = auto couple.
7. Trace mode = max hold.
8. Allow trace to fully stabilize.
9. Use the peak marker function to determine the maximum amplitude level within the RBW.
10. If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat.


                                                             Signal Analyzer
                      EUT                  Attenuator



Test Equipment List and Details

                                                                   Serial         Calibration     Calibration
      Manufacturer           Description          Model
                                                                  Number             Date          Due Date
     Rohde & Schwarz        Signal Analyzer       FSIQ26         8386001028       2015-12-11      2016-12-11
        Ducommun
                               RF Cable           RG-214              3           2015-06-15      2016-06-15
       technologies
      WEINSCHEL             10dB Attenuator        5324            AU0709         2015-06-18      2016-06-18

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed in accordance to requirements that traceable to National Primary Standards and International System
of Units (SI).




FCC Part 15.247                                                                                   Page 29 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ160519003-00A

Test Data
     Environmental Conditions

             Temperature:                     26 ℃
        Relative Humidity:                     56 %
            ATM Pressure:                    101.0 kPa

     The testing was performed by Haiguo Li on 2016-05-24

     EUT operation mode: Transmitting

     Test Result: Pass

                                             Frequency           PSD                  Limit
               Channel
                                               (MHz)          (dBm/3kHz)           (dBm/3kHz)

                   Low                          2412            -13.95                  ≤8
                  Middle                        2437            -13.47                  ≤8
                  High                          2462            -14.09                  ≤8

                                       Power Spectral Density, Low Channel




              Date: 24.MAY.2016   17:41:33




FCC Part 15.247                                                                              Page 30 of 31


Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ160519003-00A

                                    Power Spectral Density, Middle Channel




             Date: 24.MAY.2016   18:01:17




                                      Power Spectral Density, High Channel




             Date: 24.MAY.2016   18:13:13


                                        ***** END OF REPORT *****

FCC Part 15.247                                                                             Page 31 of 31



Document Created: 2019-11-12 00:39:43
Document Modified: 2019-11-12 00:39:43

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC