test rpt

FCC ID: PZK-02320

Test Report

Download: PDF
FCCID_734306

                                              SGS-CSTC Standards Technical Services Ltd.

    1/F., Building No. 1 Building, A
    No.198 Kezhu Road, Science Town Economic& Technology
    Development District Guangzhou, China 510663
    Telephone:      +86 (0) 20 8215 5555
    Fax:            +86 (0) 20 8207 5059
    Email: sgs_internet_operations@sgs.com

    FEDERAL COMMUNICATIONS COMMISSION
                                                                                  Report No.: SZEMO061002297RFI
    Registration number: 556682                                                   Page:       1 of 12
                                                                                  FCC ID:     PZK-02320

                                    FCC TEST REPORT
       Application No. :               SZEMO061002297RF
       Applicant:                      Summer Infant, Inc.
       FCC ID:                         PZK-02320
       Fundamental Carrier             Frequency : 2.4GHz
       Equipment Under Test (EUT):
       Name:                           02170-Secure Sounds 2.4GHz Digital Monitor and 02320-2 Receiver
                                       Digital Audio Monitor
       Item No.:                       02170 and 02320♣
       Country of Origin:              China
       Country of Destination:         US
       ♣                               Please refer to section 2 of this report which indicates which item was
                                       actually tested and which were electrically identical.
       Standards:                      FCC PART 15: 2006
       Date of Receipt:                30 October 2006
       Date of Test:                   02 to 17 November 2006
       Date of Issue:                  22 November 2006

       Test Result :                     PASS *

   *      In the configuration tested, the EUT complied with the standards specified above.




 Authorized Signature:




 Robinson Lo
 Laboratory Manager

This report refers to the General Conditions for Inspection and Testing Services, printed overleaf
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product
sample detailed in this report.
This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that
detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. Any mention of SGS
International Electrical Approvals or testing done by SGS International Electrical Approvals in connection with, distribution or use of
the product described in this report must be approved by SGS International Electrical Approvals in writing.

                                    Member of the SGS Group (Société Générale de Surveillance)


                                    SGS-CSTC Standards Technical Services Ltd.
                                                             Report No.: SZEMO061002297RFI
                                                             Page:           2 of 12


2   Test Summary
                                                           Stanadard
     Test                     Test Requirement                                         Result
                                                           Paragraph
     Flied Strength of
                               FCC PART 15 :2006        Section 15.249 (a)             PASS
     Fundamental

     Flied Strength of                                  Section 15.249 (a)
     Harmornics or other       FCC PART 15 :2006                                       PASS *
     Frequency                                          Section 15.209

     Occupied Bandwidth        FCC PART 15 :2006        Section 15.249                 PASS

     Band Edges Measurement    FCC PART 15 :2006        Section 15.249 (d)             PASS

    * Remark:
    The EUT passed the Spurious Emission from Tx test after Modification as below:
    Add 27pF capacitance between L15 and F1 to earth.




FCC ID: PZK-02320


                                                                 SGS-CSTC Standards Technical Services Ltd.
                                                                                                         Report No.: SZEMO061002297RFI
                                                                                                         Page:                 3 of 12




3         Contents
                                                                                                                                                                         Page
1       COVER PAGE........................................................................................................................................... 1

2       TEST SUMMARY ................................ ................................ ................................ ................................ .................... 2

3       CONTENTS ................................ ................................ ................................ ................................ .............................. 3

4       GENERAL INFORMATION................................ ................................ ................................ ................................ ....4
    4.1         CLIENT INFORMATION ................................ ................................ ................................ ................................ .......4
    4.2         GENERAL DESCRIPTION OF E.U.T. ................................ ................................ ................................ .................. 4
    4.3         DESCRIPTION OF SUPPORT UNITS ................................ ................................ ................................ ................... 4
    4.4         STANDARDS APPLICABLE FOR TESTING ................................ ................................ ................................ ........... 4
    4.5         TEST LOCATION ................................ ................................ ................................ ................................ ................ 4
    4.6         OTHER INFORMATION REQUESTED BY THE CUSTOMER ................................ ................................ .................. 4
5       TEST RESULTS ................................ ................................ ................................ ................................ ...................... 5
    5.1     TEST INSTRUMENTS ................................ ................................ ................................ ................................ .......... 5
    5.2     E.U.T. OPERATION ................................ ................................ ................................ ................................ ........... 5
    5.3     TEST PROCEDURE & MEASUREMENT DATA ................................ ................................ ................................ ....6
       5.3.1 Spurious Radiated Emissions ................................ ................................ ................................ .................. 6
       5.3.2 Occupied Bandwidth & Band Edge ................................ ................................ ................................ . 11-12




FCC ID: PZK-02320


                                       SGS-CSTC Standards Technical Services Ltd.
                                                              Report No.: SZEMO061002297RFI
                                                              Page:        4 of 12



4    General Information
4.1 Client Information
     Applicant Name:           Summer Infant, Inc.
     Applicant Address:        582 Great Road, North Smithfield, RI 02896, USA

4.2 General Description of E.U.T.
     Product Name:             02170-Secure Sounds 2.4GHz Digital Monitor and 02320-2 Receiver
                               Digital Audio Monitor
     Item No.:                 02170 and 02320♣
     Power Supply:             Transmitter Part : 4.5V DC(3*1.5 “AAA” Size Batteries)


     Power Cord:               N/A-

4.3 Description of Support Units
     The EUT was tested as an independent unit.

4.4 Standards Applicable for Testing
     The customer requested FCC tests for 02170-Secure Sounds 2.4GHz Digital Monitor and 02320-2
     Receiver Digital Audio Monitor.
     The standard used was FCC PART 15, SUBPART C (2006) section 15.249.

4.5 Test Location
     All tests were performed at:-
    SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou EMC Laboratory, No.198 Kezhu
    Road, Science Town Economic& Technology Development District Guangzhou, China 510663

    Tel: +86 20 8215 5555             Fax: +86 20 8207 5059

4.6 Other Information Requested by the Customer
     None.




FCC ID: PZK-02320


                                    SGS-CSTC Standards Technical Services Ltd.
                                                             Report No.: SZEMO061002297RFI
                                                             Page:         5 of 12



5     Test Results
5.1 Test Instruments
                                                                     Cal.Date        Cal.Due date
    Item Test Equipment       Manufacturer          Serial No.
                                                                     (dd-mm-yy)      (dd-mm-yy)
         3m Semi-Anechoic
     1                        ETS-LINDGREN          SEL0017          28-04-2005      27-04-2007
         Chamber
     2   EMI Test Receiver    Rohde & Schwarz       100249           22-09-2006      21-09-2007
     3   EMI Test software    AUDIX                 E3               N/A             N/A
     4   Coaxial cable        SGS                   SEL0028          20-05-2006      19-05-2007
         BiConiLog Antenna
     5                        ETS-LINDGREN          00042673         03-03-2006      02-03-2007
         (26-3000MHz)
         Pre-amplifier
     6                        Agilent Technologies 2944A10861        26-08-2006      25-08-2007
         (0.1-1300MHz)
         Double-ridged horn
     7                        ETS-LINDGREN          00035926         30-12-2004      29-12-2006
         (1-18GHz)
         Pre-amplifier
     8                        Rohde & Schwarz       1091457          29-07-2005      28-07-2007
         (1-18GHz)
                              MCE Mobile
     9   Cable (0-18GHz)                            249439           20-05-2006      19-05-2007
                              Communications
     9   Shielding Room       ZhongYu Electron      SEL0042          N/A             N/A

    10   LISN                 ETS-LINDGREN          00033512         19-09-2006      18-09-2007

    11   EMI Test Receiver    Rohde & Schwarz       100119           03-03-2006      02-03-2007

    12   Coaxial Cable        SGS                   SEL0024          20-05-2006      19-05-2007



     5.2 E.U.T. Operation
     Input voltage:             Transmitter Part : 4.5V DC(3*1.5 “AAA” Size Batteries)
     Operating Environment:
     Temperature:               24.0 °C
     Humidity:                  52 % RH
     Atmospheric Pressure:      1015 mbar
     EUT Operation:             Test in transmitting mode:




FCC ID: PZK-02320


                                       SGS-CSTC Standards Technical Services Ltd.
                                                               Report No.: SZEMO061002297RFI
                                                               Page:         6 of 12



 5.3 Test Procedure & Measurement Data
 5.3.1 Spurious Radiated Emissions
 5.3.1.1 Test in transmitting mode
          Test Requirement:            FCC Part15 C
          Test Method:                 Based on FCC Part15 C Section 15.249
          Test Date:                   02 November 2006(Initial Test)
                                       17 November 2006(Test after Modification)
          Measurement Distance:        3m (Semi-Anechoic Chamber)
          Frequency range              30 MHz – 10GHz for transmitting mode.
                                       Test instrumentation resolution bandwidth
                                       120 kHz (30 MHz - 1000 MHz), 1 MHz (1000 M – 25GHz)
          Operation:                   Receive antenna scan height 1 - 4 m, polarization Vertical/
                                       Horizontal
          Requirements:
                                                                              Field Strength of Harmonics
           Fundamental Frequency         Field Strength of Fundamental
                                                                                and Spurious Emissions
                    (MHz)                       (dBuV/m @ 3m)
                                                                                    (dBuV/m @ 3m)
                 902 to 928                           94.0                                54.0
               2400 to 2483.5                         94.0                                54.0
                5725 to 5875                          94.0                                54.0
               24000 to 24250                         108.0                               68.0
          The fundamental frequency of the EUT is 2455MHz
          The limit for average field strength dBuv/m for the fundamental frequency = 94.0 dBµV/m.
          No fundamental is allowed in the restricted bands.
          The limit for average field strength dBµV/m for the harmonics and spurious frequencies = 54.0
          dBµV/m. Spurious in the restricted bands must be less than 54.0 dBuv/m or 15.209.


 Test Procedure: The procedure uesd was ANSI Standard C63.4-2003. The receive was scanned from
 30MHz to 25GHz.When an emission was found,the table was roated to produce the maximum signal
 strength. An initial pre-scan was performed for in peak detection mode using the receiver. The EUT was
 measured for both the Horizontal and Vertical polarities and performed a pre-test three orthogonal planes.
 For intentional radiators, measurements of the variation of the input power or the radiated signal level of
 the fundamental frequency component of the emission, as appropriate, shall be performed with the
 supply voltage varied between 85% and 115% of the nominal rated supply voltage. The worst case
 emissions were reported.




FCC ID: PZK-02320


                          SGS-CSTC Standards Technical Services Ltd.
                                        Report No.: SZEMO061002297RFI
                                        Page:    7 of 12



    Test Configuration:




FCC ID: PZK-02320


                                     SGS-CSTC Standards Technical Services Ltd.
                                                              Report No.: SZEMO061002297RFI
                                                              Page:        8 of 12

     The field strength is calculated by adding the Antenna Factor, Cable Factor & Peramplifier . The basic
     equation with a sample calculation is as follows:
     Final Test Level =Receiver Reading + Antenna Factor + Cable Factor – Peramlifer Factor
     The following test results were performed on the EUT:
    For Radiated Emission(30M—1GHz)
    Vertical
                                  Antenna    Preamp       Read
      Frequency       Cable                                             Level      Limit Line     Over
                                   Factor     Factor       Level
         (MHz)      Loss (dB)                                         (dBuV/m)     (dBuV/m)     Limit (dB)
                                   (dB/m)       (dB)     (dBuV)
        76.260         1.10          8.36      27.97       46.2         27.69         40.0        -12.31
        95.950         1.16          8.95      27.91      46.74         28.94         43.5        -14.56
       104.540         1.21          8.87      27.83      49.28         31.53         43.5        -11.97
       159.230         1.34          9.56      27.39      43.26         26.77         43.5        -16.73
       211.100         1.47         10.81      27.09      40.12         25.31         43.5        -18.19
       334.910         2.08         15.53      27.12      39.89         30.38         46.0        -15.62

    Horizontal
                                 Antenna     Preamp        Read
      Frequency      Cable                                              Level      Limit Line     Over
                                  Factor      Factor       Level
        (MHz)       Loss (dB)                                         (dBuV/m)     (dBuV/m)     Limit (dB)
                                  (dB/m)       (dB)       (dBuV)
       55.225         0.80          7.87      28.08        34.52        15.11         40.0        -24.89
       81.550         1.10          7.87      27.99        34.25        15.23         40.0        -24.77
       117.625        1.25          8.07      27.71        35.10        16.71         43.5        -26.79
       186.850        1.38         10.04      27.22        35.15        19.35         43.5        -24.15
       285.325        1.84         13.27      26.77        32.81        21.15         46.0        -24.85
       431.575        2.34         16.54      27.51        33.01        24.38         46.0        -21.62




FCC ID: PZK-02320


                                          SGS-CSTC Standards Technical Services Ltd.
                                                                  Report No.: SZEMO061002297RFI
                                                                  Page:         9 of 12

Above 1GHz
                                             Peak Measurement
     Test Frequency      Measuring Level (dBuV/m)               Limits            Margin (dB)
          (GHz)           V er t ic a l      H o r i zontal   (dBuV/m)    Ver t i c a l   H or i zontal
           2.4554           87.8                 77.6          114. 0       26.20            36.40
                                          Average M easurem en t
           2 .45 5 4        73.4                63.2           94.0         20.60            30.80
     (2). Harmonics & Spurious Emissions
                                             Peak Measurement
      Test Frequency      Measuring Level (dBuV/m)              Limits            Margin (dB)
           (GHz)           Ver t ic a l      H o r i zontal   (dBuV/m)    Ver t i c a l   H or i zontal
      2)      4910.72        68.53              58.12          74.0         5.47            15.88
      3)      7366.08        65.67              55.41          74.0         8.33            18.59
      4)      9821.44        39.60              39.61          74.0        34.40            34.39
      5)      12276.80         N/A               N/A           74.0          N/A              N/A
      6)      14732.16         N/A               N/A           74.0          N/A              N/A
      7)      17187.52         N/A               N/A           74.0          N/A              N/A
      8)      19642.88         N/A               N/A           74.0          N/A              N/A
      9)      22098.24         N/A               N/A           74.0          N/A              N/A
     10)      24553.60         N/A               N/A           74.0          N/A              N/A
                                              Average Measurement
      2)      4910.72        48.84              39.85          54.0         5.16            15.15
      3)      7366.08        42.20              34.60          54.0        11.80            19.40
      4)      9821.44        36.00              30.90          54.0        18.00            23.10
      5)      12276.80         N/A               N/A           54.0          N/A              N/A
      6)      14732.16         N/A               N/A           54.0          N/A              N/A
      7)      17187.52         N/A               N/A           54.0          N/A              N/A
      8)      19642.88         N/A               N/A           54.0          N/A              N/A
      9)      22098.24         N/A               N/A           54.0          N/A              N/A
     10)      24553.60         N/A               N/A           54.0          N/A              N/A




FCC ID: PZK-02320


                                      SGS-CSTC Standards Technical Services Ltd.
                                                               Report No.: SZEMO061002297RFI
                                                               Page:         10 of 12



    N/A: refer to remark 1).


    Remark:
    1). For this intentional radiator operates below 10 GHz, the spectrum shall be investigated to the tenth
       harmonic of the highest fundamental frequency. And above the fifth harmonic of
                                                                                                 th
       this intentional radiator, the disturbance is very low. So the test result only displays to 4 harmonic.


    2). According to 15.249 (e) As shown in Section 15.35(b), for frequencies above 1000 MHz, the above
       field strength limits are based on average limits. However, the peak field strength of any emission
       shall not exceed the maximum permitted average limits specified above by more than 20 dB under
       any condition of modulation.


    TEST RESULTS: The unit does meet the FCC requirements.




FCC ID: PZK-02320


                                          SGS-CSTC Standards Technical Services Ltd.
                                                                  Report No.: SZEMO061002297RFI
                                                                  Page:         11 of 12




 5.3.2 Occupied Bandwidth & Band Edge
         Test Requirement:           FCC Part 15 C
         Test Method:                Based on FCC Part15 C Section 15.249:
                                     Operation within the band 2.4000 – 2.4835GHz
         Test Date:                  03 November 2006
         Requirements:               15.249 (d) Emissions radiated outside of the specified frequency bands,
                                     except for harmonics, shall be attenuated by at least 50 dB below the
                                     level of the fundamental or to the general radiated emission limits in
                                     Section 15.209, whichever is the lesser attenuation.
         Method of                   A small sample of the transmitter output was fed into the Spectrum
         measurement:                Analyzer and the attached plot was taken. The vertical is set to 10dB per
                                     division. The horizontal scale is set to 1MHz per division.

         The occupied bandwidth and band edge as below:
                                                         * RBW 100 kHz   Delta 3 [T1 ]
                                                         * VBW 300 kHz             -20.62 dB
              Ref   102 dBµV          * Att   10 dB      * SWT 500 ms       360.000000000 kHz
              100                                                        Marker 1 [T1 ]
                                                        1                          91.96 dBµV
                                                                              2.455420000 GHz    A
                      D1 91.9 dBµV
              90
                                                                         Delta 2 [T1 ]
     1 SA *
                                                                                   -20.07 dB
     VIEW
              80
                                                                           -480.000000000 kHz

                                                   2        3
                         D2 71.9 dBµV
              70


                                                                                                 PS
              60



              50

                                                                                                 3DB
              40



              30



              20



              10



              Center 2.45536 GHz                      1 MHz/                       Span 10 MHz




     N
     Date: 3.NOV.2006          09:29:52




FCC ID: PZK-02320


                                      SGS-CSTC Standards Technical Services Ltd.
                                                              Report No.: SZEMO061002297RFI
                                                              Page:         12 of 12




    The test result for the Emissions radiated outside of the specified frequency bands , please refer
    the section 5.3.1 of this report.                                                                a
    The worst case is 43.8dBuV/m at frequency 4.96440GHz, it’s below the limits in Section 15.209.
    For the field strength of Lower Edges:2.4000GHz is 23.6dBuV/m.
    For the field strength of Upper Edges:2.4835GHz is 29.7dBuV/m.
    The results: The unit does meet the FCC requirements.




FCC ID: PZK-02320



Document Created: 2019-06-25 10:24:14
Document Modified: 2019-06-25 10:24:14

© 2024 FCC.report