Test report

FCC ID: PZ3-FM72

Test Report

Download: PDF
FCCID_183834

              L.S. Compliance, Inc.
              W66 N220 Commerce Court
              Cedarburg, WI 53012
              262-375-4400

_____________________________________________________________________________




COMPLIANCE TESTING OF:

Quartex Synchronization Transmitter
Model FM-72


PREPARED FOR:

Quartex, Division of Primex, Inc.
965 Wells Street
Lake Geneva, WI 53147




TEST REPORT NUMBER:

301190 T

DATE(S) OF TESTING:
October 19th and 30th, 2001

All results of this report relate only to the items that were tested. This report is not to be
reproduced, except in full, without written approval of L. S. Compliance, Inc.


                                      Table of Contents


  Section                           Description                    Test     Page
                                                                   Type
   Index                                                                       2
     1           L. S. Compliance in Review                                    3
     2           A2LA Certificate of Accreditation                             4
     3           A2LA Scope of Accreditation                                   5
     4           Validation Letter-U.S. Competent Body for EMC                 6
                 Directive 89/336/EEC
     5           Signature Page                                               7
     6           Product and General Information                              8
     7           Product Description                                          8
     8           Test Requirements                                            8
     9           Summary of Test Report                                       9
    10           Introduction                                                 9
    11           Purpose                                                      9
    12           Radiated Emissions Test, enclosure                FCC      10-15
    13           Conducted Emission Test, AC line                  FCC      16-20
    14           Test Equipment List                                         21
 Appendix
    A            Part 90 Type Acceptance, Conducted Measurements              22




L.S. Compliance, Inc.                                                     Page 2 of 22
Test Report Number: 301190 T
Prepared For: Quartex


1. L. S. Compliance In Review
L. S. Compliance, Inc. is located in Cedarburg, Wisconsin – United States.

         We may be contacted by:

         Mail:      L. S. Compliance, Inc.
                    W66 N220 Commerce Court
                    Cedarburg, Wisconsin 53012

         Phone: 262-375-4400
         Fax:    262-375-4248
         E-mail: eng@lsr.com

As an EMC Testing Laboratory, our Accreditation and Assessments are recognized
through the following:

A2LA – American Association for Laboratory Accreditation
Accreditation based on ISO/IEC 17025 : 1999
with Electrical (EMC) Scope of Accreditation
A2LA Certificate Number: 1255.01

U. S. Conformity Assessment Body (CAB) Validation
Validated by the European Commission as a U. S. Conformity Assessment Body operating
under the U. S. /EU, Mutual Recognition Agreement (MRA) operating under the
European Union EMC Directive 89/336/EEC, Article 10.2.
Date of Validation: January 16, 2001

Federal Communications Commission (FCC) – USA
Listing of 3 Meter Semi-Anechoic Chamber based on 47CFR 2.948
FCC Registration Number: 90756

Listing of 3 and 10 meter OATS based on 47CFR 2.948
FCC Registration Number: 90757

Industry Canada
On-file, 3 Meter Semi-Anechoic Chamber based on 47CRF 2.948
File Number: IC 3088

On-file 3 and 10 Meter OATS based on RSS-210
File Number: IC 3088-A




L.S. Compliance, Inc.                                                        Page 3 of 22
Test Report Number: 301190 T
Prepared For: Quartex


2.    A2LA Certificate of Accreditation




L.S. Compliance, Inc.                     Page 4 of 22
Test Report Number: 301190 T
Prepared For: Quartex


3.    A2LA Scope of Accreditation




L.S. Compliance, Inc.               Page 5 of 22
Test Report Number: 301190 T
Prepared For: Quartex


4. Validation Letter – U.S. Competent Body for EMC Directive
                        89/336/EEC




L.S. Compliance, Inc.                                          Page 6 of 22
Test Report Number: 301190 T
Prepared For: Quartex


5.       Signature Page




Prepared By:                                                         November 9, 2001
                               Teresa A. White, Document Coordinator      Date




Tested By:                                                               November 9, 2001
                               Kenneth L. Boston, EMC Lab Manager            Date




Tested By:                                                              November 9, 2001

                               Thomas T. Lee, EMC Engineer                     Date
                               NARTE Test Lab Engineer, ALT-0064-E




Approved By:                                                              November 9, 2001
                               Kenneth L. Boston, EMC Lab Manager                Date
                               PE#31926 Licensed Professional Engineer
                               Registered in the State of Wisconsin, United States



L.S. Compliance, Inc.                                                             Page 7 of 22
Test Report Number: 301190 T
Prepared For: Quartex


6.    Product and General Information


Manufacturer:                  Quartex, Division of Primex, Inc.
Model No.:                     FM-72
Serial No.:                    Pre-production
Description:                   Data Transmitter
Frequency Range:               72.0 – 73.0 MHz


7.      Product Description
The FM-72 is a data transmitter, which sends telemetry to various co-located paging receivers,
which are located in wall clocks, for the purpose of time synchronization. It is provided for by
47 CFR, Part 90.238 as a telemetry device.




8.    Test Requirements

The following FCC requirements are met: 47 CFR, 2.1053, 90.257(b)(2), 90.210.




L.S. Compliance, Inc.                                                             Page 8 of 22
Test Report Number: 301190 T
Prepared For: Quartex


9.    Summary of Test Report

                               DECLARATION OF CONFORMITY

The Equipment Under Test (EUT) was found to MEET the requirements as described within
the specification of Title 47 CFR FCC, Part 90, Subpart J, and Part 2.1053 Radiated Spurious
Emissions for a low-power non-broadcast transmitter.


10.     Introduction

On October 19, 2001 a series of Radiated Emission tests were performed on the EUT. These
tests were performed using the procedures outlined in ANSI C63.4-2001 for unintentional
radiators, and in accordance with the limits set forth in FCC Part 90 for a non-voice and other
specialized operation transmitters. These tests were performed by Kenneth Boston, EMC Lab
Manager and Thomas T. Lee, EMC Engineer/NARTE Test Lab Engineer of L.S. Compliance.


11.     Purpose

All Radiated Emission tests upon the EUT were performed to measure the emissions in the
frequency bands described in title 47 CFR, FCC Part 90, including 90.210 (general technical
parts) to determine whether these emissions are below the limits expressed within the standards.
AC line Conducted Emissions were also measured and compared to the CFR, Part 15.207 limits,
as additional technical data. These tests were performed in accordance with the procedure
described in the American National Standard for methods of measurement of Radio-Noise
Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40
GHz (ANSI C63.4-2001). Another document used as a reference for the EMI Receiver
specification was the Comite International Special Des Perturbations Radioelelectriques
(CISPR) Number 16-1, 1993.




L.S. Compliance, Inc.                                                           Page 9 of 22
Test Report Number: 301190 T
Prepared For: Quartex


12. Radiated Emissions Test

Test Setup
The test setup was assembled in accordance with ANSI C63.4-2001. The Quartex FM-72 was
placed on an 80cm high non-conductive table centered on a flush mounted 2-meter diameter
turntable inside the 3 Meter Semi-Anechoic, FCC listed Chamber located at L. S. Compliance,
Inc., Cedarburg, Wisconsin. The EUT was operated in normal mode, using AC power as
provided by a wall transformer. The transmitter was set to operate continuously, on one channel
(72.24 MHz), and a suitable artificial antenna load was connected to the antenna port for the
duration of the radiated emissions tests. Signal levels that were seen to be close to the
regulatory limits were verified using a substitution method, with a tuned Dipole. The applicable
limits are provided at a 3 meter distance. The calculations to determine these limits are detailed
in the following pages. Please refer to Appendix A for a list of the test equipment.

Test Procedure
Spurious radiation measurements were performed on the EUT in the 3 Meter Semi-Anechoic,
FCC listed Chamber, located at L. S. Compliance, Inc. in Cedarburg, Wisconsin. The frequency
range from 30 MHz to 1000 MHz was scanned, and levels were manually noted at the various
fixed degree settings of azimuth on the turntable and antenna height. The EUT was placed on
the non-conductive wooden table in the 3 Meter Semi-Anechoic Chamber, with the antenna
mast placed such that the antenna was 3 meters from the test object. A Biconical Antenna was
used to measure emissions from 30 MHz to 300 MHz, and a Log Periodic Antenna was used to
measure emissions from 300 MHz to 1000 MHz.             The maximum radiated emissions were
found by raising and lowering the antenna between 1 and 4 meters in height, using both
horizontal and vertical antenna polarities.




L.S. Compliance, Inc.                                                           Page 10 of 22
Test Report Number: 301190 T
Prepared For: Quartex


Test Equipment Utilized
A list of the test equipment and antennas utilized for the Radiated Emissions test can be found
in Appendix A. Included in this list are calibration information and equipment descriptions. All
equipment is calibrated and used according to the operations manual supplied by the
manufacturer. All calibrations of the antennas used were performed at an N.I.S.T. traceable
site. In addition, the Connecting Cables were measured for losses using a calibrated Signal
Generator and a HP 8546A EMI Receiver. The resulting correction factors and the cable loss
factors from these calibrations were entered into the HP 8546A EMI Receiver database. As a
result, the data taken from the HP 8546A EMI Receiver accounts for the antenna correction
factor as well as cable loss or other corrections, and can therefore be entered into the database as
a corrected meter reading. The HP 8546A EMI Receiver was operated with a bandwidth of
120 kHz for measurements below 1 GHz. Both the Peak and Quasi-Peak Detector functions
were utilized.

Test Results
The EUT was found to MEET the Radiated Emissions requirements of Title 47 CFR, FCC Part
90.257(b)(2) for an unintentional radiator (Canada RSS-210). The frequencies with significant
signals were recorded and plotted as shown in the Data Charts and Graphs.

Notes:




L.S. Compliance, Inc.                                                             Page 11 of 22
Test Report Number: 301190 T
Prepared For: Quartex


                           Calculation of Radiated Emissions Limits

                        FIELD STRENGTH OF SPURIOUS/HARMONIC FREQUENCIES

                               In accordance with Section 90.210 (2.1053)
        All out of band spurious emissions must be below the mean power of the carrier by at least:

                                          43 + 10 log(carrier power)

                               which for a 1.0 watt rating on the test sample is:

                                                43 + 10 log(1))
                                                 43 = 43 dBc

                                    -43 dBc from 30 dBm = -13. dBm


             FIELD STRENGTH OF PART 90 LIMIT:                      AT R   = 3 METERS DSTANCE

   FROM THE STANDARD REFERENCE FORMULA FOR P OWER TRANSMITTED VERSUS ELECTRIC FIELD:

                                          Pt = (R**) x E** / 30

                                            Then to convert to dB:

                                    Pt = 20logE + 20log(R) - 10log(30)

      Insert additional terms to convert watts to milli-watts (in dB) and volts to micro-volts (in dBµV):

                  Pt = 20logEµv -20 log(1,000,000) +10log(1000) +20log(3) - 10log(30)

                                 Pt = 20logEµv - 120 +30 +9.54 - 14.77

                                          Pt = 20logEµv - 95.23

                                 OR;     20logEµv = Pt (in dBm) + 95.23

                      E (in dBµV) = -13 dBm + 95.23 = 82.23 dBµV/m , at 3 meters


Summary of Results and Conclusions
Based on the procedures outlined in this report, and the test results included in Appendices A and B, it
can be determined that the EUT does MEET the emission requirements of Title 47 CFR, FCC Part 15,
Subpart B (Industry Canada RSS-210) for an unintentional radiator.

The enclosed test results pertain to the samples of the test item listed, and only for the tests performed
per the data sheets. Any subsequent modification or changes to the test items could invalidate the data
contained herein, and could therefore invalidate the findings of this report.


L.S. Compliance, Inc.                                                                      Page 12 of 22
Test Report Number: 301190 T
Prepared For: Quartex


                              Measurement of Electromagnetic Radiated Emissions
                                      upon a 3 Meter I. C. Listed Site

                                Frequency Range inspected: 30 MHz - 1,000 MHz

            Date of Test:       October 19, 2001                   Manufacturer: Quartex, Div. Of Primex, Inc.

            Location of Test: L. S. Compliance, Inc.                Model No.:      FM-72
                              W66 N220 Commerce Court
                              Cedarburg, WI 53012                     Serial No.:   Pre-Production

                                                                   Configuration: Continuous TX on 72.24 MHz
               Specifications:         90.257(b)(2), 2.1053
             Detector(s) Used:         Peak

                     Distance: 3 Meters

            Equipment:      HP 8546A EMI Receiver; EMCO 3115 Double-Ridged Waveguide Antenna;
                            EMCO 3146A Log Periodic Antenna; EMCO 3110 Biconical Antenna


                            The following table depicts the level of significant emissions found:

Frequency    Antenna                      Height      Azimuth        EMI Meter Reading                        Margin
  (MHz)      Polarity    Channel         (meters)    (0° - 360°)        (dBµV/m)            (dBµV/m)           (dB)
   90.1         V          --              1.0          180°               30.0                82.2            52.2
   180.2        V          --              1.0          180°               25.0                82.2            57.2
   723.0        V          --              1.0          180°               29.0                82.2            53.2




        Notes: Emissions seen with antenna port terminated with a 50 ohm terminating load. All other
        signals seen were even further below the Part 90 limit of −13 dBµ except the fundamental,
        which is covered in the Appendix.

        L.S. Compliance, Inc.                                                                 Page 13 of 22
        Test Report Number: 301190 T
        Prepared For: Quartex


Photos Taken During Radiated Emissions Testing



                  Test Setup for Radiated Emissions Testing in the 3 Meter Chamber




                      View of the EUT during the Radiated Emissions Testing.
                 Antenna in place, but port internally terminated with a 50 Ohm load.




L.S. Compliance, Inc.                                                             Page 14 of 22
Test Report Number: 301190 T
Prepared For: Quartex


Graphs made during Radiated Emissions Testing


                               Signature Scan of Radiated Emissions
                                  Vertical Polarity, 30 MHz – 300 MHz




                               Signature Scan of Radiated Emissions
                                 Horizontal Polarity, 30 MHz – 300 MHz




L.S. Compliance, Inc.                                                    Page 15 of 22
Test Report Number: 301190 T
Prepared For: Quartex


                               Signature Scan of Radiated Emissions
                                  Vertical Polarity, 30 MHz – 1000 MHz




                               Signature Scan of Radiated Emissions
                                Horizontal Polarity, 300 MHz – 1000 MHz




L.S. Compliance, Inc.                                                     Page 16 of 22
Test Report Number: 301190 T
Prepared For: Quartex


13. Conducted Emissions Test (AC Line)

Test Setup
The Conducted Emissions test was performed within the 3 Meter Semi-Anechoic, FCC listed Chamber,
or FCC listed Shielded Room, located at L.S. Compliance, Inc. in Cedarburg, Wisconsin. The test area
and setup are in accordance with ANSI C63.4-2001 and with Title 47 CFR, FCC Part 15, Subpart B
(Industry Canada RSS-210). The EUT was placed on a non-conductive wooden table, with a height of
80 cm above the reference ground plane. The EUT’s power supply was plugged into a 50Ω (ohm),
50/250 µH Line Impedance Stabilization Network (LISN). The AC power supply of 120V was fed into
the 3 Meter Semi-Anechoic Chamber via an appropriate broadband EMI Filter, and then to the LISN line
input. Final readings were then taken and recorded. After the EUT was setup in the 3 Meter Semi-
Anechoic Chamber and connected to the LISN, the RF Sampling Port of the LISN was cabled to a 10 dB
Attenuator-Limiter, and then to the HP 8546A EMI Receiver. The EMCO LISN used has the ability to
terminate the unused port with a 50Ω (ohm) load when switched to either L1 (line) or L2 (neutral).

Test Procedure
The appropriate frequency range and bandwidths were entered into the EMI Receiver, and measurements
were made. The bandwidth used for these measurements is 9 kHz, as specified in CISPR 16-1 (1993),
Section 1, Table 1, for Quasi-Peak and Average detectors in the frequency range of 150 kHz to 30MHz.
Final readings were then taken and recorded.

Test Equipment Utilized
A list of the test equipment and accessories utilized for the Conducted Emissions test is found in
Appendix A. This list includes calibration information and equipment descriptions. All equipment is
calibrated and used according to the operations manual supplied by the manufacturer. Calibrations of the
LISN and Limiter are traceable to N.I.S.T. All cables are calibrated and checked periodically for
malfunction. The emissions are measured on the HP 8546A EMI Receiver, which has automatic
correction for all factors stored in memory and allows direct readings to be taken.

Test Results
The EUT was found to MEET the Conducted Emissions requirements of FCC Part 15, Conducted
Emissions. See the Data Charts and Graphs for more details of the test results.

Notes:
This test is not required of a Part 90 device, and was performed only as an additional step to insure a
higher performance level in the environments for which this product is intended.




L.S. Compliance, Inc.                                                                Page 17 of 22
Test Report Number: 301190 T
Prepared For: Quartex


                     Measurement of Electromagnetic Conducted Emission
                                   in the Shielded Room

                         Frequency Range inspected: 450 KHz to 30 MHz

  Date of Test:        October 30, 2001          Manufacturer: Quartex, Div. Of Primex, Inc.

  Location of Test: L. S. Compliance, Inc.         Model No.:     FM-72
                    W66 N220 Commerce Court
                    Cedarburg, WI 53012             Serial No.:   Pre-Production

                                                 Configuration: Continuous TX on 72.24 MHz
     Specifications: 15.207 used, not required
   Detector(s) Used: Quasi-Peak

             Distance:         N/A


  Equipment:       HP 8546A EMI Receiver; EMCO 3816nm L.I.S.N.



    Frequency                             EMI Reading          Limit               Margin
     (MHz)                      Line       (dBµV/m)          (dBµV/m)               (dB)
       .597                      L2           44.8              48.0                 3.2
       .897                      L2           43.6              48.0                 4.4
      1.040                      L2           43.8              48.0                 4.2
       .597                      L1           47.3              48.0                 0.7
       .898                      L1           46.2              48.0                 1.8
      1.370                      L1           45.5              48.0                 2.5




L.S. Compliance, Inc.                                                       Page 18 of 22
Test Report Number: 301190 T
Prepared For: Quartex


Photos Taken During Conducted Emissions Testing


                               Test Setup for Conducted Emissions Testing




                       Views of the EUT during the Conducted Emissions Testing.




L.S. Compliance, Inc.                                                             Page 19 of 22
Test Report Number: 301190 T
Prepared For: Quartex


Graphs made during Conducted Emissions Testing


                      Signature Scan of Conducted Emissions, Line 1




                      Signature Scan of Conducted Emissions, Line 2




L.S. Compliance, Inc.                                                 Page 20 of 22
Test Report Number: 301190 T
Prepared For: Quartex


14.   Test Equipment List

                                                                                             Calibration
                                                                                             Information
  Asset #       Manufacturer           Model #   Serial #        Description               Date    Due Date

 AA960004 EMCO                93146        9512-4276        Log-Periodic Antenna        02-28-01      02-28-02
 AA960005 EMCO                3110B        9601-2280        Biconical Antenna           09-24-01      09-24-02
 EE960004 EMCO                2090         9607-1164        Mast/Ttable Controller      N/A           N/A
 EE960013 HP                  8546A        3617A00320 Receiver RF Section               11-01-00      11-01-01
 EE960014 HP                  85460A       3448A00296 Receiver Pre-Selector             11-01-00      11-01-01
   N/A      LSC               Cable        0011             3 meter ½” Heliax Cable     12-07-00      12-07-01
   N/A      LSC               Cable        0038             1 meter RG 214 Cable        12-07-00      12-07-01
   N/A      LSC               Cable        0050             10 meter RG 214 Cable       12-07-00      12-07-01
   N/A      LSC               Attenuator                    10 db Attenuator
      Note 1* - Equipment calibrated within a traceable system.


               Table of Expanded Uncertainty Values, (K=2) for Specified Measurements
        Measurement Type              Particular Configuration          Uc Value in Appropriate
                                                                        Units
        Radiated Emissions            3 Meter Chamber,                  4.24 dB
                                      Biconical Antenna
        Radiated Emissions            3 Meter Chamber,                  4.80 dB
                                      Log Periodic Antenna
        Radiated Emissions            10 Meter OATS,                    4.18 dB
                                      Biconical Antenna
        Radiated Emissions            10 Meter OATS,                    3.92 dB
                                       Log Periodic Antenna
        Conducted Emissions           Shielded Room/EMCO LISN           1.60 dB




        L.S. Compliance, Inc.                                                         Page 21 of 22
        Test Report Number: 301190 T
        Prepared For: Quartex


                                    APPENDIX A

                      Part 90 Type Acceptance, Conducted Measurements




L.S. Compliance, Inc.                                                   Page 22 of 22
Test Report Number: 301190 T
Prepared For: Quartex



Document Created: 2019-07-02 16:25:42
Document Modified: 2019-07-02 16:25:42

© 2024 FCC.report