                                         SAR Compliance Test Report

 Test report no.:       FCC_RM-1135_04                       Date of report:         2015-06-23
 Template version:      19.85                                Number of pages:        21
 Testing laboratory:    TCC Microsoft Beijing                Client:                 Microsoft
                        Laboratory                                                   Beijing Economic and
                        Beijing Economic and                                         Technological Development
                        Technological Development                                    Area
                        Area                                                         No.5 Donghuan Zhonglu
                        No.5 Donghuan Zhonglu                                        Beijing
                        Beijing                                                      PRC China 100176
                                                                                     Tel. +86 10 8711 8888
                        PRC China 100176
                                                                                     Fax. +86 10 8711 4550
                        Tel. +86 10 8711 8888
                        Fax. +86 10 8711 4550
 Responsible test       Zhang Luwen                          Product contact         Hu Dongji
 engineer:                                                   person:
 Measurements made      Yuan Rui, He Ying
 by:

 Tested device:         RM-1135, HW0240 and HW0242
 FCC ID:                PYARM-1135                                             IC:   -

 Supplement reports:    FCC_RM-1135_01 and SAR_Photo_RM-1135_05

 Testing has been       47CFR §2.1093
 carried out in               Radiofrequency Radiation Exposure Evaluation: Portable Devices
 accordance with:       FCC published RF exposure KDB procedures
                        RSS-102, Issue 4
                              Evaluation Procedure for Mobile and Portable Radio Transmitters with Respect to
                              Health Canada’s Safety Code 6 for Exposure of Humans to Radio Frequency Fields
                        IEEE 1528 - 2013
                              IEEE Recommended Practice for Determining the Peak Spatial-Average Specific
                              Absorption Rate (SAR) in the Human Head from Wireless Communications Devices:
                              Measurement Technique

 Documentation:         The documentation of the testing performed on the tested devices is archived for 15 years
                        at TCC Microsoft.

 Test results:          The tested device complies with the requirements in respect of all parameters
                        subject to the test. The test results and statements relate only to the items tested. The
                        test report shall not be reproduced except in full, without written approval of the
                        laboratory.

 Date and signatures:
                                                                       Digitally signed by Zhang Luwen
 For the contents:                                                     DN: cn=Zhang Luwen,
                                                                       o=Microsoft, ou=RCL,
                                                                       email=luwen.zhang@microsoft.c
                                                                       om, c=CN
                                                                       Date: 2015.06.23 09:31:03 +08'00'
SAR Report                                                                                               Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                     Copyright  2015 TCC Microsoft

                                                      1/21


 ____________________________________________________________________________
 CONTENTS

 1.       SUMMARY OF SAR TEST REPORT ............................................................................................................................... 4
      1.1     TEST DETAILS ......................................................................................................................................................................... 4
      1.2     MAXIMUM RESULTS .............................................................................................................................................................. 4
         1.2.1 Head Configuration .................................................................................................................................................... 4
         1.2.2 Body-worn 15 mm Configuration.......................................................................................................................... 4
         1.2.3 Summary SAR data ..................................................................................................................................................... 5
         1.2.4 Maximum Drift ............................................................................................................................................................. 5
         1.2.5 Measurement Uncertainty ........................................................................................................................................ 5
 2.       DESCRIPTION OF THE DEVICE UNDER TEST .......................................................................................................... 6
      2.1           BANDS AND MODES OF THE DUT ...................................................................................................................................... 6
      2.2           DUT FEATURES AND TEST REQUIREMENTS ........................................................................................................................ 6
 3.       CONDUCTED POWERS ...................................................................................................................................................... 7
      3.1     GSM ....................................................................................................................................................................................... 7
         3.1.1 GSM850 Head, Body-worn 15 mm........................................................................................................................ 7
         3.1.2 GSM1900 Head, Body-worn 15 mm ..................................................................................................................... 7
 4.       DESCRIPTION OF THE TEST EQUIPMENT ................................................................................................................ 8
      4.1     MEASUREMENT SYSTEM AND COMPONENTS .................................................................................................................... 8
         4.1.1 Isotropic E-field Probe Type EX3DV4 .................................................................................................................... 9
      4.2     PHANTOMS ......................................................................................................................................................................... 10
      4.3     TISSUE SIMULANTS ............................................................................................................................................................. 10
         4.3.1 Tissue Simulant Recipes ......................................................................................................................................... 10
      4.4     SYSTEM VALIDATION AND SYSTEM CHECKING ................................................................................................................ 11
         4.4.1 System validation status ........................................................................................................................................ 11
         4.4.2 System checking ........................................................................................................................................................ 11
      4.5     TISSUE SIMULANTS USED IN THE MEASUREMENTS ......................................................................................................... 13
 5.       DESCRIPTION OF THE TEST PROCEDURE .............................................................................................................. 14
      5.1     DEVICE HOLDER .................................................................................................................................................................. 14
      5.2     TEST POSITIONS .................................................................................................................................................................. 14
         5.2.1 Against Phantom Head .......................................................................................................................................... 14
         5.2.2 Body-worn 15 mm Configuration....................................................................................................................... 14
      5.3     SCAN PROCEDURES ............................................................................................................................................................ 14
      5.4     SAR AVERAGING METHODS ............................................................................................................................................. 15
 6.       MEASUREMENT UNCERTAINTY ................................................................................................................................. 16
 7.       RESULTS................................................................................................................................................................................. 18
      7.1     THE MEASURED HEAD SAR VALUES FOR THE TEST DEVICE ............................................................................................ 18
         7.1.1 GSM 850 Head SAR results for HW0240......................................................................................................... 18
         7.1.2 GSM 850 Head SAR results for HW0242......................................................................................................... 18
         7.1.3 GSM 1900 Head SAR results for HW0240 ...................................................................................................... 19
         7.1.4 GSM 850 Head SAR results for HW0242......................................................................................................... 19
      7.2     THE MEASURED BODY-WORN 15 MM SAR VALUES FOR THE TEST DEVICE ................................................................. 20
SAR Report                                                                                                                                                                       Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                                                                               Copyright  2015 TCC Microsoft

                                                                                                 2/21


 ____________________________________________________________________________
     7.2.1 GSM 850 Body-worn 15 mm SAR results for HW0240 ............................................................................. 20
     7.2.2 GSM 850 Body-worn 15 mm SAR results for HW0242 ............................................................................. 20
     7.2.3 GSM 1900 Body-worn 15 mm SAR results for HW0240 .......................................................................... 21
     7.2.4 GSM 1900 Body-worn 15 mm SAR results for HW0242 .......................................................................... 21


 APPENDIX A: SYSTEM CHECK SCANS

 APPENDIX B: MEASUREMENT SCANS

 APPENDIX C: DIELECTRIC PARAMETERS OF THE TISSUE SIMULANTS

 APPENDIX D: RELEVANT PAGES FROM PROBE CALIBRATION REPORTS

 APPENDIX E: RELEVANT PAGES FROM DIPOLE VALIDATION REPORTS




SAR Report                                                                                                              Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                                Copyright  2015 TCC Microsoft

                                                                  3/21


 ____________________________________________________________________________
 1. SUMMARY OF SAR TEST REPORT

 1.1 Test Details

 Period of test                       2015-06-03 to 2015-06-18
 HW and SW numbers of tested device   RM-1135, HW: 0240 and 0242, SW: 10.02.14
 Batteries used in testing            BL-5CB: 54928, 54929, 54930, 54931
 Headsets used in testing             WH-108: 54873, 54874
 Other accessories used in testing    -
 State of sample                      Prototype unit
 Notes                                -



 1.2 Maximum Results

       The maximum reported SAR values for Head, Body-worn 15 mm configurations are given in section 1.2.1, 1.2.2
       respectively. The device conforms to the requirements of the standards when the maximum measured SAR value
       is less than or equal to the limit.

 1.2.1 Head Configuration

                                                      Reported*
                                                                          SAR limit
                            Mode                      SAR value                          Result   Plot #
                                                                          (1g avg)
                                                       (1g avg)
                          GSM850                      1.11 W/kg           1.6 W/kg      PASSED      H1
                          GSM1900                     0.98 W/kg           1.6 W/kg      PASSED      H2


 1.2.2 Body-worn 15 mm Configuration

                                                      Reported*
                                                                          SAR limit
                            Mode                      SAR value                          Result   Plot #
                                                                          (1g avg)
                                                       (1g avg)
                          GSM850                      0.46 W/kg           1.6 W/kg      PASSED      B1
                          GSM1900                     0.30 W/kg           1.6 W/kg      PASSED      B2



 * Reported SAR values are scaled to, or measured at, upper limit of power tuning tolerance.




SAR Report                                                                                            Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                  Copyright  2015 TCC Microsoft

                                                         4/21


 ____________________________________________________________________________
 1.2.3 Summary SAR data


                                                                    FCC-defined SAR values for the
                                        Description               Grants of Equipment Authorization

                                                                    PCE           DTS           NII

                              Maximum Head SAR values               1.11           -             -

                        {Max + Max} Simultaneous Head SAR value                    -

                        Maximum Body-worn 15 mm SAR values          0.46           -             -

                       {Max + Max} Simultaneous Body-worn 15 mm
                                                                                   -
                                       SAR value

                          Maximum Simultaneous SAR value
                                                                                  1.11
                                  Head SAR: GSM850


 Note:
      PCE contains the highest results between all cellular modes (cellular, AWS and PCS bands)
      DTS contains the highest results between WLAN 2.4 GHz + RLAN 5725-5850 MHz
      NII contains the highest results between RLAN 5150-5250, 5250-5350 and 5470-5725 MHz


 1.2.4 Maximum Drift

             Maximum drift during measurements                         ≤ 0.2 dB


 1.2.5 Measurement Uncertainty

               Expanded Uncertainty (k=2) 95 %                         ± 29.8 %




SAR Report                                                                                               Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                     Copyright  2015 TCC Microsoft

                                                           5/21


 ____________________________________________________________________________
 2. DESCRIPTION OF THE DEVICE UNDER TEST

                 Device category                                        Portable
                 Exposure environment                                   General population / uncontrolled


 2.1 Bands and Modes of the DUT

                                                                                                            Transmitter
                                                                                             Channel
                                       Modes of          Modulation           Duty                          Frequency
                        Bands                                                               Bandwidth
                                       Operation           Mode               Cycle                           Range
                                                                                              (MHz)
                                                                                                               (MHz)

                        850               GSM               GMSK               1/8                           824 – 849

                        1900              GSM               GMSK              1/8                           1850 – 1910




 2.2 DUT Features and Test Requirements

 Common features                   Testing / Specification / KDB
                                   HW0240:1
 Number of SIM cards:
                                   HW0242:1
                                   The Project RM-1135 has two HW versions, which are HW0240 and HW0242. The testing of all
                                   RM-1135 HW 0242 cellular bands has been minimised based on the earlier report FCC_RM-1135_01.
 Test bands
                                   The difference between HW 0240 and HW 0242 is that HW0242 have RF components from 2nd
                                   source supplier.
 Ambient temperature:              20.5 – 22.5 °C / Controlled
 Ambient humidity (RH %):          35 – 55 % RH / Controlled

 Antennas                          One antenna for cellular bands.

                                   The device output power was set to maximum power level for all tests.
 Output power and batteries
                                   A fully charged battery was used for every test sequence.

                                   In all operating bands the measurements were performed on lowest, middle and highest channels,
 Test channels
                                   and/or on all required test channels as defined in Published FCC KDB Procedures.
 GSM/GPRS/EGPRS                    KDB 941225 D03 SAR Test Reduction Procedures for GSM/GPRS/EDGE
 Call tester settings              CMU200: MS signal was always set to maximum power: Pmax 5 for GSM850 and 0 for GSM1900.




SAR Report                                                                                                         Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                              Copyright  2015 TCC Microsoft

                                                                     6/21


 ____________________________________________________________________________
 3. CONDUCTED POWERS

 The conducted output power of the device was measured by a separate test laboratory on the same units as used for
 SAR testing.

 Shaded lines in the tables below show which mode/configuration is used in testing.

 3.1 GSM

 3.1.1 GSM850 Head, Body-worn 15 mm

                                                                  HW0240
                                                                  GSM 850
  SN: 004402741723641                                          Conducted power (dBm)                      Time-averaged power (dBm)
                             Tuning
                                       Upper limit    CH 128          CH 190        CH 251        CH 128            CH 190          CH 251
        Slot configuration    target
                                         (dBm)       824.2 MHz       836.6 MHz     848.8 MHz    824.2 MHz         836.6 MHz       848.8 MHz
                             (dBm)
           GSM 1-slot         32.0        32.4          31.7           31.8            31.8        22.7             22.8              22.8
           GPRS 2-slot        N/A         N/A           N/A            N/A             N/A         N/A              N/A               N/A
           GPRS 3-slot        N/A         N/A           N/A            N/A             N/A         N/A              N/A               N/A
           GPRS 4-slot        N/A         N/A           N/A            N/A             N/A         N/A              N/A               N/A
                                                                  HW0242
                                                                  GSM 850
  SN: 004402741723468                                          Conducted power (dBm)                      Time-averaged power (dBm)
                             Tuning
                                       Upper limit    CH 128          CH 190        CH 251        CH 128            CH 190          CH 251
        Slot configuration    target
                                         (dBm)       824.2 MHz       836.6 MHz     848.8 MHz    824.2 MHz         836.6 MHz       848.8 MHz
                             (dBm)
           GSM 1-slot         32.0        32.4          31.9           32.0            32.0        22.9             23.0              23.0
           GPRS 2-slot        N/A         N/A           N/A            N/A             N/A         N/A              N/A               N/A
           GPRS 3-slot        N/A         N/A           N/A            N/A             N/A         N/A              N/A               N/A
           GPRS 4-slot        N/A         N/A           N/A            N/A             N/A         N/A              N/A               N/A
 3.1.2 GSM1900 Head, Body-worn 15 mm

                                                                  HW0240
                                                                  GSM 1900
  SN: 004402741722213                                          Conducted power (dBm)                      Time-averaged power (dBm)
                             Tuning
                                       Upper limit     CH 512         CH 661         CH 810       CH 512           CH 661          CH 810
        Slot configuration    target
                                         (dBm)       1850.2 MHz     1880.0 MHz     1909.8 MHz   1850.2 MHz       1880.0 MHz      1909.8 MHz
                             (dBm)
           GSM 1-slot         30.0        30.4          30.3           30.3            30.4        21.3             21.3              21.3
           GPRS 2-slot        N/A         N/A           N/A            N/A             N/A         N/A              N/A               N/A
           GPRS 3-slot        N/A         N/A           N/A            N/A             N/A         N/A              N/A               N/A
           GPRS 4-slot        N/A         N/A           N/A            N/A             N/A         N/A              N/A               N/A
                                                                  HW0242
                                                                  GSM 1900
  SN: 004402741723468                                          Conducted power (dBm)                      Time-averaged power (dBm)
                             Tuning
                                       Upper limit     CH 512         CH 661         CH 810       CH 512           CH 661          CH 810
        Slot configuration    target
                                         (dBm)       1850.2 MHz     1880.0 MHz     1909.8 MHz   1850.2 MHz       1880.0 MHz      1909.8 MHz
                             (dBm)
           GSM 1-slot         30.0        30.4          30.0           30.0            30.0        20.9             21.0              21.0
           GPRS 2-slot        N/A         N/A           N/A            N/A             N/A         N/A              N/A               N/A
           GPRS 3-slot        N/A         N/A           N/A            N/A             N/A         N/A              N/A               N/A
           GPRS 4-slot        N/A         N/A           N/A            N/A             N/A         N/A              N/A               N/A




SAR Report                                                                                                                    Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                               Copyright  2015 TCC Microsoft

                                                                   7/21


 ____________________________________________________________________________

 4. DESCRIPTION OF THE TEST EQUIPMENT

 4.1 Measurement System and Components

       The measurements were performed using an automated DASY near-field scanning system manufactured by
       Schmid & Partner Engineering AG (SPEAG) in Switzerland. The SAR extrapolation algorithm used in all
       measurements was the ‘advanced extrapolation’ algorithm.

       The following table lists calibration dates of SPEAG components:


                                                                                     Calibration
                          Test Equipment                      Serial Number                             Calibration expiry
                                                                                        date
       DAE 4                                                         860              2014-09                2015-09
       DAE 4                                                         480              2014-09                2015-09
       E-field Probe EX3DV4                                         3839              2014-09                2015-09
       E-field Probe EX3DV4                                         3574              2014-09                2015-09
       Dipole Validation Kit, D835V2                                4d005             2014-03                2016-03
       Dipole Validation Kit, D1900V2                                509              2014-09                2016-09
       DASY5 software                                          Version 52.8               -                     -




       Additional test equipment used in testing:


                                                                                         Calibration         Calibration
                     Test Equipment                 Model            Serial Number
                                                                                            date               expiry
       Signal Generator                             8648C             3847M00258              2015-04          2016-04
       Signal Generator                             SME03              846923/014             2015-04          2016-04
       Amplifier                                ZHL-42W                QA1252001                 -                  -
       Amplifier                               ZHL-4240W               e060204/1                 -                  -
       Power Meter                                   NRP                    101293            2015-04          2016-04
       Power Meter                                  NRVD               840297/008             2015-04          2016-04
       Power Sensor                             NRV-Z51                     101135            2015-04          2016-04
       Power Sensor                             NRP-Z51                     100410            2015-04          2016-04
       Call Tester                              CMU200                 835352/008                -                  -
       Call Tester                              CMU200                 831593/001                -                  -
       RF Network Analyzer                          E5071C            MY46104578              2015-04          2016-04
       RF Network Analyzer                          8753ES            My40002096              2015-04          2016-04
       Dielectric Probe Kit                     DAK-3.5                      1123                -                  -
       Dielectric Probe Kit                         85070C                   2577                -                  -




SAR Report                                                                                                      Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                          Copyright  2015 TCC Microsoft

                                                             8/21


 ____________________________________________________________________________
 4.1.1 Isotropic E-field Probe Type EX3DV4

   Construction
                                    Symmetrical design with triangular core
                                    Built-in shielding against static charges
                                    PEEK enclosure material (resistant to organic solvents, e.g., DGBE)

   Calibration                      Calibration certificate in Appendix D
   Frequency                        10 MHz to >6 GHz (dosimetry); Linearity: ± 0.2 dB (30 MHz to 6 GHz)
   Directivity                      ± 0.3 dB in HSL (rotation around probe axis)
                                    ± 0.5 dB in tissue material (rotation normal to probe axis)
   Dynamic Range                    10 µW/g to > 100 mW/g, Linearity: ± 0.2 dB
   Dimensions                       Overall length: 330 mm
                                    Tip length: 10 mm
                                    Body diameter: 12 mm
                                    Tip diameter: 2.5 mm
                                    Distance from probe tip to dipole centers: 1.0 mm

   Application                      General dosimetry up to 6 GHz
                                    Compliance tests of mobile phones
                                    Fast automatic scanning in arbitrary phantoms




SAR Report                                                                                                Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                  Copyright  2015 TCC Microsoft

                                                         9/21


 ____________________________________________________________________________
 4.2 Phantoms

       The phantom used for all Head SAR tests i.e. for both system checks and device testing, was the twin-headed
       "SAM Phantom", manufactured by SPEAG; the SAM phantom conforms to the requirements of IEEE 1528.

       The phantom used for all Body SAR tests i.e. for both system checks and device testing, was a flat phantom also
       manufactured by SPEAG this phantom conform to the requirements of FCC published RF Exposure KDB
       Procedures.

       The SPEAG device holder (see Section 5.1) was used to position the device in all tests whilst a tripod was used to
       position the validation dipoles against the flat section of phantom.


 4.3 Tissue Simulants

       Recommended values for the dielectric parameters of the tissue simulants are given in IEEE 1528 and FCC
       published RF Exposure KDB Procedures. All tests were carried out using simulants whose dielectric parameters
       were within  5% of the recommended values. All tests were carried out within 24 hours of measuring the
       dielectric parameters.

       The depth of the tissue simulant was at least 15.0 cm for all system check and device tests, measured from the
       ear reference point in the case of the SAM phantom and from the inner surface of the flat phantom.

 4.3.1 Tissue Simulant Recipes

       The following recipe(s) were used for Head and Body tissue simulant(s):


                                                      850 MHz band
                                                          Head                           Body
                  Ingredient
                                                      (% by weight)                  (% by weight)
                   Deionised Water                        39.74                          55.97
                   HEC                                    0.25                           1.21
                   Sugar                                  58.31                          41.76
                   Preservative                            0.15                           0.27
                   Salt                                   1.55                           0.79


                                                         Head                           Body
                  Ingredient
                                                     (% by weight)                  (% by weight)
                  Deionised Water                        51.50                          69.25
                  Tween 20                               47.35                          30.00
                  Salt                                    1.15                           0.75



                                                     1900 MHz band
                                                         Head                          Body
                  Ingredient
                                                     (% by weight)                 (% by weight)
                  Deionised Water                        54.50                          70.25
                  Tween 20                               45.23                          29.41
                  Salt                                   0.27                            0.34




SAR Report                                                                                                Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                    Copyright  2015 TCC Microsoft

                                                          10/21


 ____________________________________________________________________________

 4.4 System validation and System checking

 4.4.1 System validation status

            Probe                                                                                              DAE            Validation done
                                                                                          Calibrated
          Calibration          Test          DASY            Dipole          Probe                             unit          Head         Body
                                                                                            signal
             Point            System          SW            Type / SN      Type / SN                          Type /         tissue       tissue
                                                                                           type(s)
           f / MHz                                                                                             SN          simulant     simulant
                                TCC
                                                              D835V2 /     EX3DV4 /                           DAE4 /
             835              Beijing /      V52.8                                              CW                         2015-03        2015-03
                                                               4d005         3839                             860
                               SAR-1
                                TCC
                                                            D1900V2 /      EX3DV4 /                           DAE4 /
             1900             Beijing /      V52.8                                              CW                         2015-03        2015-03
                                                               509           3574                             480
                               SAR-4



 4.4.2 System checking

       The manufacturer calibrates the probes annually. Dielectric parameters of the tissue simulants were measured
       every day using the dielectric probe kit and the network analyser. A system check measurement was made
       following the determination of the dielectric parameters of the simulant, using the dipole validation kit. A power
       level of 250 mW was supplied to the dipole antenna. The dipole was placed under the flat section of the twin
       SAM phantom for head system checking, and under the flat phantom for body system checking. The system
       checking results (dielectric parameters and SAR values) are given in the table below.



                                                     System checking, head tissue simulant


                                                                                                  SAR 1g
                                                    Estimated                                                    Dielectric Parameters
   Dipole                                 Estimated           Scaled 1W Dielectric Parameters    Deviation
                                                                                                                 Deviation from target
                               SAR 1g                SAR 1g                                     from target                                 Temp    Plot
    freq.     Description                  SAR 1g              SAR 1g
                               [W/kg]               Dev. dSAR                                                                                [°C]    #
   [MHz]                                   [W/kg]              [W/kg]
                                                       [%]
                                                                            er        s [S/m]    dSAR [%]        der [%]        ds [%]

               Tolerances                              ±3%                                        ±10 %           ±5 %           ±5 %
              Target result                                                                                        TCC Bej / SAR1
                                  -           -         -          9.32     41.5       0.90
    835         SN:4d005                                                                                        3839 Head 835 MHz
               2015-06-03       2.35        2.40       2.13        9.40     41.6       0.91          0.86          0.24           1.11       21.1    -
               2015-06-05       2.32        2.34       0.86        9.28     41.9       0.89          -0.43         0.96          -1.11       20.5    -
               2015-06-18       2.39        2.42       1.26        9.56     40.9       0.91          2.58         -1.45           1.11       20.5    1
               Tolerances                              ±3%                                        ±10 %           ±5 %           ±5 %
              Target result                                                                                        TCC Bej / SAR4
                                  -           -         -         40.10     40.0       1.40
    1900         SN:509                                                                                         3574 Head 1900 MHz
               2015-06-03       9.58        9.55      -0.31       38.32     38.8       1.39          -4.44        -3.00          -0.71       21.0    -
               2015-06-18       9.54        9.66       1.26       38.16     38.3       1.37          -4.84        -4.25          -2.14       20.5    2

       * Dielectric parameter reference data taken from IEEE1528/IEC622094




SAR Report                                                                                                                               Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                                            Copyright  2015 TCC Microsoft

                                                                          11/21


 ____________________________________________________________________________
                                                System checking, body tissue simulant
                                                                                             SAR 1g
                                               Estimated                                                  Dielectric Parameters
   Dipole                            Estimated           Scaled 1W Dielectric Parameters    Deviation
                                                                                                          Deviation from target
                            SAR 1g              SAR 1g                                     from target                               Temp    Plot
    freq.   Description               SAR 1g              SAR 1g
                            [W/kg]             Dev. dSAR                                                                              [°C]    #
   [MHz]                              [W/kg]              [W/kg]
                                                  [%]
                                                                       er        s [S/m]   dSAR [%]       der [%]        ds [%]

             Tolerances                           ±3%                                        ±10 %         ±5 %           ±5 %
            Target result                                                                                   TCC Bej / SAR1
                              -          -         -        9.31       55.2       0.97
    835       SN:4d005                                                                                   3839 Body 835 MHz
             2015-06-03      2.42      2.45       1.24      9.68       53.3       0.94        3.97         -3.44          -3.09       21.1    -
             2015-06-18      2.49      2.52       1.20      9.96       53.6       0.96        6.98         -2.90          -1.03       20.5    3
             Tolerances                           ±3%                                        ±10 %         ±5 %           ±5 %
            Target result                                                                                   TCC Bej / SAR4
                              -          -         -        38.70      53.3       1.52
    1900       SN:509                                                                                    3574 Body 1900 MHz
             2015-06-03      9.18      9.25       0.76      36.72      52.6       1.49        -5.12        -1.31          -1.97       21.0    4
             2015-06-18      9.39      9.30      -0.96      37.56      53.7       1.51        -2.95         0.75          -0.66       20.5    -



       * Dielectric parameter reference data taken from FCC Published RF Exposure KDB Procedures

       Plots of the system checking scans are given in Appendix A.




SAR Report                                                                                                                        Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                                     Copyright  2015 TCC Microsoft

                                                                    12/21


 ____________________________________________________________________________
 4.5 Tissue Simulants used in the Measurements

                                        Head tissue simulant measurements

                                                                          Dielectric Parameters
                                                        Dielectric
                        f                                                    Deviation from       Temp
                                                       Parameters
                                                                          recommended value

                   [MHz]         Description          er       s [S/m]     der [%]     ds [%]     [°C]
                                 Tolerances                                 ±5 %        ±5 %
                       835   Recommended value       41.5          0.90
                                 2015-06-03          41.6          0.91      0.24        1.11     21.1
                                 2015-06-05          41.9          0.89      0.96       -1.11     20.5
                                 2015-06-18          40.9          0.91     -1.45        1.11     20.5
                                 Tolerances                                 ±5 %        ±5 %
                   1880      Recommended value       40.0          1.40
                                 2015-06-03          38.9          1.37     -2.75       -2.14     21.0
                                 2015-06-18          38.4          1.35     -4.00       -3.57     20.5



                                        Body tissue simulant measurements

                                                                          Dielectric Parameters
                                                        Dielectric
                        f                                                    Deviation from       Temp
                                                       Parameters
                                                                          recommended value

                   [MHz]         Description          er       s [S/m]     der [%]     ds [%]     [°C]
                                 Tolerances                                 ±5 %        ±5 %
                       835   Recommended value       55.2          0.97
                                 2015-06-03          53.3          0.94     -3.44       -3.09     21.1
                                 2015-06-18          53.6          0.96     -2.90       -1.03     20.5
                                 Tolerances                                 ±5 %        ±5 %
                   1880      Recommended value       53.3          1.52
                                 2015-06-03          52.7          1.47     -1.13       -3.29     21.0
                                 2015-06-18          53.7          1.49      0.75       -1.97     20.5
 Dielectric parameter data for the band edges is given in Appendix C.




SAR Report                                                                                               Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                    Copyright  2015 TCC Microsoft

                                                           13/21


 ____________________________________________________________________________
 5. DESCRIPTION OF THE TEST PROCEDURE

 5.1 Device Holder

       The device was placed in the device holder (illustrated below) that is supplied by SPEAG as an integral part of
       the Dasy system.




                                                Device holder supplied by SPEAG

       A spacer (illustrated below) was used to position the device within the SPEAG holder. The spacer positions the
       device so that the holder has minimal effect on the test results but still holds the device securely. The spacer was
       removed before the tests.




                                                             Spacer

 5.2 Test Positions

 5.2.1 Against Phantom Head

       Measurements were made in “cheek” and “tilt” positions on both the left hand and right hand sides of the
       phantom.

       The positions used in the measurements were according to IEEE 1528 "IEEE Recommended Practice for
       Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless
       Communications Devices: Measurement Techniques".

 5.2.2 Body-worn 15 mm Configuration

       The device was placed in the SPEAG holder using the spacer and placed below the flat phantom. The distance
       between the device and the phantom was kept at the separation distance indicated in Section 1.2 using a
       separate flat spacer that was removed before the start of the measurements. The device was oriented with both
       sides facing the phantom to find the highest results.

       Microsoft Body-worn accessories are commonly available for the separation distance used in this testing.

 5.3 Scan Procedures

       First, area scans were used for determination of the field distribution. Next, a zoom scan, a minimum of 5x5x7
       points covering a volume of at least 30x30x30mm, was performed around the highest E-field value to determine
SAR Report                                                                                                 Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                     Copyright  2015 TCC Microsoft

                                                           14/21


 ____________________________________________________________________________
       the averaged SAR value. Drift was determined by measuring the same point at the start of the area scan and
       again at the end of the zoom scan. Fast SAR is measured according to the KDB 447498 D01 General RF Exposure
       Guidance v05r01.

 5.4 SAR Averaging Methods

       The maximum SAR value was averaged over a cube of tissue using interpolation and extrapolation.

       The interpolation, extrapolation and maximum search routines within Dasy52 are all based on the modified
       Quadratic Shepard’s method (Robert J. Renka,”Multivariate Interpolation of Large Sets of Scattered Data”,
       University of North Texas ACM Transactions on Mathematical Software, vol. 14, no. 2, June 1988, pp. 139-148).

       The interpolation scheme combines a least-square fitted function method with a weighted average method. A
       trivariate 3-D / bivariate 2-D quadratic function is computed for each measurement point and fitted to
       neighbouring points by a least-square method. For the zoom scan, inverse distance weighting is incorporated to
       fit distant points more accurately. The interpolating function is finally calculated as a weighted average of the
       quadratics.

       In the zoom scan, the interpolation function is used to extrapolate the Peak SAR from the deepest measurement
       points to the inner surface of the phantom.




SAR Report                                                                                               Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                   Copyright  2015 TCC Microsoft

                                                         15/21


 ____________________________________________________________________________
 6. MEASUREMENT UNCERTAINTY

                    Table 6.1 – Measurement uncertainty evaluation for 1g Full SAR in 0.3-6G Hz range
                                                          Secti
                                                          on in     Tol.    Prob                ci       ci .ui   vi
        Uncertainty Component                                                         Div
                                                          IEEE      (%)      Dist                        (%)
                                                          1528
        Measurement System
        Probe Calibration                                 E2.1      6.6       N       1         1        6.6    
        Axial Isotropy                                    E2.2      4.7       R      3     (1-cp)1/2    1.9    
        Hemispherical Isotropy                            E2.2      9.6       R      3      (cp)1/2     3.9    
        Boundary Effect                                   E2.3      2.0       R      3         1        1.2    
        Linearity                                         E2.4      4.7       R      3         1        2.7    
        System Detection Limits                           E2.5      1.0       R      3         1        0.6    
        Modulation response                               E2.5      2.4       R      3         1        1.4
        Readout Electronics                               E2.6      0.3       N       1         1        0.3    
        Response Time                                     E2.7      0.8       R      3         1        0.5    
        Integration Time                                  E2.8      2.6       R      3         1        1.5    
        RF Ambient Conditions - Noise                     E6.1      3.0       R      3         1        1.7    
        RF Ambient Conditions - Reflections               E6.1      3.0       R      3         1        1.7    
        Probe Positioner Mechanical Tolerance             E6.2      0.8       R      3         1        0.5    
        Probe Positioning with respect to Phantom
                                                          E6.3      6.7       R      3         1        3.9    
        Shell
        Extrapolation, interpolation and Integration
                                                            E5      4.0      R       3        1         2.3    
        Algorithms for Max. SAR Evaluation
        Test sample Related
        Test Sample Positioning                            E4.2     6.0      N       1         1         6.0    11
        Device Holder Uncertainty                          E4.1     3.6      N       1         1         3.6     5
        Output Power Variation - SAR drift
                                                           E2.9     5.0      R       3        1         2.9    
        measurement
        Phantom and Tissue Parameters
        Phantom Uncertainty (shape and thickness
                                                           E3.1     6.6      R       3        1         3.8    
        tolerances)
        SAR correction                                     E3.2     1.9      R       3        1         1.1    
        Conductivity Target - tolerance                    E3.4     5.0      R       3       0.6        1.8    
        Conductivity - measurement uncertainty             E3.3     5.5      N        1       0.6        3.5    5
        Permittivity Target - tolerance                    E3.4     5.0      R       3       0.6        1.7    
        Permittivity - measurement uncertainty             E3.3     2.9      N        1       0.6        1.7    5
        Combined Standard Uncertainty                                        RSS                         14.0    198
        Coverage Factor for 95%                                              k=2
        Expanded Uncertainty                                                                             28.2




SAR Report                                                                                               Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                   Copyright  2015 TCC Microsoft

                                                         16/21


 ____________________________________________________________________________
                    Table 6.2 – Measurement uncertainty evaluation for 1g Fast SAR in 0.3-6G Hz range
                                     Relative DASY5 Uncertainty Budget for Fast SAR Tests
                                      According to IEEE 1528/2011 and IEC 62209-1/2011
                                                       (0.3-6 GHz range)
                                                              Tol.        Prob                     ci           ci .ui      vi
        Uncertainty Component                                                          Div.
                                                              (%)         Dist.                                 (%)
        Measurement System
        Probe Calibration                                    ±6.6           N            1         0
        Axial Isotropy                                       ±4.7           R           3      (1-cp)1/2       ±1.9        
        Hemispherical Isotropy                               ±9.6           R           3       (cp)1/2        ±3.9        
        Boundary Effect                                      ±2.0           R           3         1            ±1.2        
        Linearity                                            ±4.7           R           3         1            ±2.7        
        System Detection Limits                              ±1.0           R           3         1            ±0.6        
        Modulation Response                                  ±2.4           R           3         1            ±1.4        
        Readout Electronics                                  ±0.3           N           1          0
        Response Time                                        ±0.8           R           3         0
        Integration Time                                     ±2.6           R           3         1            ±1.5        
        RF Ambient Conditions - Noise                        ±3.0           R           3         1            ±1.7        
        RF Ambient Conditions - Reflections                  ±3.0           R           3         0
        Probe Positioner Mechanical Tolerance                ±0.8           R           3         1            ±0.5        
        Probe Positioning with respect to Phantom Shell      ±6.7           R           3         1            ±3.9        
        Spatial x-y Resolution                               ±10.0          R           3         1            ±5.8        
        Fast SAR z Approximation                             ±14.0          R           3         1            ±8.1        
        Test sample Related
        Test Sample Positioning                              ±6.0           N            1         1            ±6.0        12
        Device Holder Uncertainty                            ±3.6           N            1          1           ±3.6         5
        Output Power Variation - SAR drift
                                                             ±5.0           R           3         1            ±2.9        
        measurement
        Power Scaling                                          ±0           R           3         0
        Phantom and Setup
        Phantom Uncertainty (shape and thickness
                                                              ±6.6          R           3          1           ±3.8        
        tolerances)
        SAR correction                                        ±1.9          R           3          0
        Conductivity Target - tolerance                       1.9          R           3          0
        Conductivity - measurement uncertainty                5.0          R           3          0
        Permittivity Target - tolerance                       5.5          N            1          0
        Permittivity - measurement uncertainty                5.0          R           3          0

        Combined Standard Uncertainty                                      RSS                                 ±14.9     748
        Coverage Factor for 95%                                            k=2
        Expanded Uncertainty                                                                                   ±29.8




SAR Report                                                                                                  Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                   Copyright  2015 TCC Microsoft

                                                         17/21


 ____________________________________________________________________________
 7. RESULTS

 7.1 The measured Head SAR values for the test device

 7.1.1 GSM 850 Head SAR results for HW0240

                                                         GSM850
                                       Measured 1g SAR [W/kg]      Reported* 1g SAR [W/kg]
                                                                                                       Max
         Device            SAR         CH 128   CH 190    CH 251   CH 128     CH 190     CH 251                 Plot
                                                                                                     Deviation*
       orientation     measurement      824.2    836.6     848.8    824.2      836.6      848.8                  #
                                        MHz      MHz       MHz      MHz        MHz        MHz         [W/kg]
              Upper limit                        32.4                      Scaling factor*
            Conducted Power            31.7      31.8      31.8      0.7        0.6           0.6       dB
          Time-averaged Power          22.7      22.8      22.8     1.17       1.15          1.15       Lin
                       Estimated SAR   0.786    0.856      0.928   0.917       0.983         1.063
        Left Cheek                                                                                     0.01        -
                          Full SAR       -        -        0.921      -          -           1.055
                       Estimated SAR     -      0.399        -        -        0.458           -
         Left Tilt                                                                                     0.03        -
                          Full SAR       -      0.373        -        -        0.428           -
                       Estimated SAR   0.781    0.855      0.910   0.911       0.982         1.042
       Right Cheek                                                                                     0.01        -
                          Full SAR       -        -        0.904      -          -           1.036
                       Estimated SAR     -      0.379        -        -        0.435           -
        Right Tilt                                                                                       -         -
                          Full SAR       -        -          -        -          -             -
        Left Cheek     Estimated SAR     -        -        0.974      -          -           1.116
                                                                                                       0.01       H1
         Repeated         Full SAR       -        -        0.966      -          -           1.107

 7.1.2 GSM 850 Head SAR results for HW0242

                                                         GSM850
                                       Measured 1g SAR [W/kg]      Reported* 1g SAR [W/kg]
                                                                                                       Max
         Device            SAR         CH 128   CH 190    CH 251   CH 128     CH 190     CH 251                 Plot
                                                                                                     Deviation*
       orientation     measurement      824.2    836.6     848.8    824.2      836.6      848.8                  #
                                        MHz      MHz       MHz      MHz        MHz        MHz         [W/kg]
              Upper limit                        32.4                      Scaling factor*
            Conducted Power            31.9      32.0      32.0      0.5        0.4           0.4       dB
          Time-averaged Power          22.9      23.0      23.0     1.12       1.10          1.10       Lin
                       Estimated SAR   0.716    0.794      0.868   0.803       0.871         0.952
        Left Cheek                                                                                     0.00        -
                          Full SAR       -        -        0.866      -          -           0.950
        Left Cheek     Estimated SAR     -        -        0.907      -          -           0.995
                                                                                                         -         -
         Repeated         Full SAR       -        -        0.907      -          -           0.995




SAR Report                                                                                                   Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                   Copyright  2015 TCC Microsoft

                                                          18/21


 ____________________________________________________________________________
 7.1.3 GSM 1900 Head SAR results for HW0240

                                                         GSM1900
                                       Measured 1g SAR [W/kg]       Reported* 1g SAR [W/kg]
                                                                                                        Max
         Device            SAR         CH 512   CH 661     CH 810   CH 512     CH 661     CH 810                 Plot
                                                                                                      Deviation*
       orientation     measurement     1850.2   1880.0     1909.8   1850.2     1880.0     1909.8                  #
                                        MHz      MHz        MHz      MHz        MHz        MHz         [W/kg]
              Upper limit                        30.4                       Scaling factor*
            Conducted Power            30.3      30.3      30.4       0.1        0.1            -        dB
          Time-averaged Power          21.3      21.3      21.4      1.02       1.02          1.00       Lin
                       Estimated SAR   0.822    0.835      0.875    0.841       0.854         0.875
        Left Cheek                                                                                      0.00        -
                          Full SAR       -        -        0.878       -          -           0.878
                       Estimated SAR     -      0.312        -         -        0.319           -
         Left Tilt                                                                                        -         -
                          Full SAR       -        -          -         -          -             -
                       Estimated SAR   0.965    0.984      0.988    0.987       1.007         0.988
       Right Cheek                                                                                      0.03       H2
                          Full SAR       -      0.957        -         -        0.979           -
                       Estimated SAR     -      0.347        -         -        0.355           -
        Right Tilt                                                                                      0.00        -
                          Full SAR       -      0.342        -         -        0.350           -
       Right Cheek     Estimated SAR     -      0.965        -         -        0.987           -
                                                                                                        0.02        -
        Repeated          Full SAR       -      0.947        -         -        0.969           -


 7.1.4 GSM 850 Head SAR results for HW0242

                                                         GSM1900
                                       Measured 1g SAR [W/kg]       Reported* 1g SAR [W/kg]
                                                                                                        Max
         Device            SAR         CH 512   CH 661     CH 810   CH 512     CH 661     CH 810                 Plot
                                                                                                      Deviation*
       orientation     measurement     1850.2   1880.0     1909.8   1850.2     1880.0     1909.8                  #
                                        MHz      MHz        MHz      MHz        MHz        MHz         [W/kg]
              Upper limit                        30.4                       Scaling factor*
            Conducted Power            30.0      30.0      30.0       0.4        0.4           0.4       dB
          Time-averaged Power          21.3      21.3      21.4      1.10       1.10          1.10       Lin
                       Estimated SAR   0.814    0.855      0.876    0.893       0.937         0.961
       Right Cheek                                                                                      0.04        -
                          Full SAR       -        -        0.832       -          -           0.912
       Right Cheek     Estimated SAR     -        -        0.856       -          -           0.939
                                                                                                        0.03        -
        Repeated          Full SAR       -        -        0.828       -          -           0.908
 Individual Head SAR plots are given in Appendix B.
 Note:
 * Reported SAR values are scaled to, or measured at, upper limit of power tuning tolerance.
 The highest result within individual zoom scan or individual expanded zoom scan results is given in Section 1.2 for
 each transmitter. The highest result within contributing individual zoom scan, individual expanded zoom scan, Speag
 combined algorithm or combined expanded zoom scan results is given in the Section for the simultaneous transmitter
 combination giving the highest combinated value.




SAR Report                                                                                                    Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                    Copyright  2015 TCC Microsoft

                                                          19/21


 ____________________________________________________________________________
 7.2 The measured Body-worn 15 mm SAR values for the test device

 7.2.1 GSM 850 Body-worn 15 mm SAR results for HW0240

                                                         GSM850
                                       Measured 1g SAR [W/kg]      Reported* 1g SAR [W/kg]
                                                                                                       Max
         Device            SAR         CH 128   CH 190    CH 251   CH 128     CH 190     CH 251                 Plot
                                                                                                     Deviation*
       orientation     measurement      824.2    836.6     848.8    824.2      836.6      848.8                  #
                                        MHz      MHz       MHz      MHz        MHz        MHz         [W/kg]
              Upper limit                        32.4                      Scaling factor*
            Conducted Power            31.7      31.8      31.8      0.7        0.6           0.6       dB
          Time-averaged Power          22.7      22.8      22.8     1.17       1.15          1.15       Lin
                       Estimated SAR     -      0.342        -        -        0.393           -
           Back                                                                                          -         -
                          Full SAR       -        -          -        -          -             -
                       Estimated SAR   0.371    0.387      0.403   0.433       0.444         0.462
         Display                                                                                         -        B1
                          Full SAR       -        -        0.403      -          -           0.462
         Display       Estimated SAR     -        -        0.322      -          -           0.369
                                                                                                         -         -
         WH-108           Full SAR       -        -          -        -          -             -


 7.2.2 GSM 850 Body-worn 15 mm SAR results for HW0242

                                                         GSM850
                                       Measured 1g SAR [W/kg]      Reported* 1g SAR [W/kg]
                                                                                                       Max
         Device            SAR         CH 128   CH 190    CH 251   CH 128     CH 190     CH 251                 Plot
                                                                                                     Deviation*
       orientation     measurement      824.2    836.6     848.8    824.2      836.6      848.8                  #
                                        MHz      MHz       MHz      MHz        MHz        MHz         [W/kg]
              Upper limit                        32.4                      Scaling factor*
            Conducted Power            31.9      32.0      32.0      0.5        0.4           0.4       dB
          Time-averaged Power          22.9      23.0      23.0     1.12       1.10          1.10       Lin
                       Estimated SAR   0.368    0.381      0.396   0.413       0.418         0.434
         Display                                                                                         -         -
                          Full SAR       -        -        0.396      -          -           0.434




SAR Report                                                                                                   Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                   Copyright  2015 TCC Microsoft

                                                          20/21


 ____________________________________________________________________________
 7.2.3 GSM 1900 Body-worn 15 mm SAR results for HW0240

                                                         GSM1900
                                       Measured 1g SAR [W/kg]       Reported* 1g SAR [W/kg]
                                                                                                        Max
         Device            SAR         CH 512   CH 661     CH 810   CH 512     CH 661     CH 810                 Plot
                                                                                                      Deviation*
       orientation     measurement     1850.2   1880.0     1909.8   1850.2     1880.0     1909.8                  #
                                        MHz      MHz        MHz      MHz        MHz        MHz         [W/kg]
              Upper limit                        30.4                       Scaling factor*
            Conducted Power            30.3      30.3      30.4       0.1        0.1            -        dB
          Time-averaged Power          21.3      21.3      21.4      1.02       1.02          1.00       Lin
                       Estimated SAR     -      0.262        -         -        0.268           -
           Back                                                                                           -         -
                          Full SAR       -        -          -         -          -             -
                       Estimated SAR   0.294    0.294      0.314    0.301       0.301         0.314
         Display                                                                                        0.01       B2
                          Full SAR       -        -        0.304       -          -           0.304
         Display       Estimated SAR     -        -        0.273       -          -           0.273
                                                                                                          -         -
         WH-108           Full SAR       -        -          -         -          -             -
 7.2.4 GSM 1900 Body-worn 15 mm SAR results for HW0242

                                                         GSM1900
                                       Measured 1g SAR [W/kg]       Reported* 1g SAR [W/kg]
                                                                                                        Max
         Device            SAR         CH 512   CH 661     CH 810   CH 512     CH 661     CH 810                 Plot
                                                                                                      Deviation*
       orientation     measurement     1850.2   1880.0     1909.8   1850.2     1880.0     1909.8                  #
                                        MHz      MHz        MHz      MHz        MHz        MHz         [W/kg]
              Upper limit                        30.4                       Scaling factor*
            Conducted Power            30.0      30.0      30.0       0.4        0.4           0.4       dB
          Time-averaged Power          21.3      21.3      21.4      1.10       1.10          1.10       Lin
                       Estimated SAR   0.240    0.238      0.251    0.263       0.261         0.275
         Display                                                                                        0.00        -
                          Full SAR       -        -        0.247       -          -           0.271
 Individual Body-worn 15 mm SAR plots are given Appendix B.

 Note:
 * Reported SAR values are scaled to, or measured at, upper limit of power tuning tolerance.
 The highest result within individual zoom scan or individual expanded zoom scan results is given in Section 1.2 for
 each transmitter. The highest result within contributing individual zoom scan, individual expanded zoom scan, Speag
 combined algorithm or combined expanded zoom scan results is given in the Section for the simultaneous transmitter
 combination giving the highest combinated value.




SAR Report                                                                                                    Type: RM-1135
FCC_RM-1135_04
Applicant: Microsoft                                                                    Copyright  2015 TCC Microsoft

                                                          21/21



Document Created: 2015-06-23 09:31:03
Document Modified: 2015-06-23 09:31:03

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC