                                         FCC Part 22/24 Compliance Test Report

 Test Report no.:                    FCC_Cellular_RM-1135_03.docx               Date of Report:   15-Jun-2015
 Number of pages:                    9                                          Customer’s        Hu Dongji
                                                                                Contact person:

 Testing laboratory:                 TCC Microsoft Beijing Laboratory           Customer:         Microsoft
                                     Beijing Economic and                                         Beijing Economic and
                                     Technological Development Area                               Technological Development Area
                                     No.5 Donghuan Zhonglu                                        No.5 Donghuan Zhonglu
                                     Beijing                                                      Beijing
                                     PRC China 100176                                             PRC China 100176
                                     Tel. +86 10 8711 8888                                        Tel. +86 10 8711 8888
                                     Fax. +86 10 8711 4550                                        Fax. +86 10 8711 4550
 FCC listing no.:                    975940
 IC recognition no.:                 661AH-1


 Tested devices/                     Phone RM-1135 / Battery BL-5CB / Charger AC-18E / Headset WH-108
 accessories:

 FCC ID:                             PYARM-1135                                 IC:               -


 Supplement reports:                 -


 Testing has been                    CFR 47, FCC rules Parts 22/24, TIA-603-C-2004 and IC standards, RSS-GEN (Issue 4,
 carried out in                      November 2014), RSS-132 (Issue 3, January 2013), RSS-133 (Issue 6, January 2013).
 accordance with:                    Deviations, modifications or clarifications (if any) to above mentioned documents are
                                     written in each section under "Test method and limit".

 Documentation:                      The test report must always be reproduced in full; reproduction of an excerpt only is subject to
                                     written approval of the testing laboratory. The documentation of the testing performed on the
                                     tested devices is archived for 15 years at TCC Microsoft.

 Test Results:                       The EUT complies with the requirements in respect of all parameters subject to the test.
                                     The test results relate only to devices specified in this document


 Date and signature                                                                     Digitally signed by Emma Ma
 for the contents:                                                                      DN: cn=Emma Ma, o=Microsoft, ou=TCC RCL,
                                                                                        email=emma.1.ma@microsoft.com, c=CN
                                                                                        Date: 2015.06.15 14:46:56 +08'00'

                                                                       Ma Emma, Specialist, EMC




FCC Part 22 Compliance Test Report                                                                TCC Microsoft Beijing Laboratory
/ Template Version 15.0                                                 1 (9)                     Beijing Economic and
                                                                                                  Technological Development Area
FCC_Cellular_RM‐1135_03                                                                           No.5 Donghuan Zhonglu
Copyright © TCC Microsoft                                                                         Beijing
                                                                                                  PRC China 100176
                                                                                                  Tel. +86 10 8711 8888
                                                                                                  Fax. +86 10 8711 4550


1.            Summary for FCC Part 22/24 Compliance Test Report
 Date of receipt                                   02-Jun-2015
 Testing completed                                 03-Jun-2015
 The customer's contact person                     Hu Dongji
 Test Plan referred to                             T:\Projects\RM-1135\TestPlan\RS_testplan_RM-1135.xlsm
 Notes                                             -
 Document name                                     FCC_Cellular_RM-1135_03.docx

1.1.          EUT and Accessory Information
The EUT is a mobile phone with following features:
GSMThe EUT is tested with maximum rated TX power.

Devices under tests
     Product            Type                             SN                              HW       MV            SW                 DUT
      Phone            RM-1135                     004402741723757                      0240       -          10.02.14            55005
     Battery           BL-5CB                495540W094S13100967;0670619                  -        -              -               54985
     Charger           AC-18E                4868674482340513172;0675735                  -        -              -               54842
     Headset           WH-108                          3022D71                            -        -              -               54459



1.2.          Summary of Test Results
 GSM 850:
                                           Section in RSS-GEN
         Section in CFR 47                                                         Name of the test                               Result
                                                or RSS-132
   §2.1046(a), 22.913(a)                  4.4                       Conducted RF output power                                 NP
   §22.913(a)                             4.4                       Radiated RF output power                                  NP
   N/A                                    5.4                       Peak to average power ratio                               NP
   §2.1049(h)                             6.6                       99 % occupied bandwidth                                   NP
   §22.917(a)                             4.5                       Band edge compliance                                      NP
   §22.917(a), §2.1051                    4.5                       Spurious emissions at antenna terminals                   NP
   §22.917(a), §2.1053                    4.5                       Spurious radiated emissions                               PASSED
   §2.1055(a)                             4.3                       Frequency stability, temperature variation                NP
   §2.1055(d)                             4.3                       Frequency stability, voltage variation                    NP

 GSM 1900:
                                           Section in RSS-GEN
         Section in CFR 47                                                         Name of the test                               Result
                                                or RSS-133
   §2.1046(a)                             6.4                       Conducted RF output power                                 NP
   §24.232(b)                             6.4                       Radiated RF output power                                  NP
   N/A                                    6.4                       Peak to average power ratio                               NP
   §2.1049(h)                             6.6                       99 % occupied bandwidth                                   NP
   §24.238(a)                             6.5                       Band edge compliance                                      NP
   §24.238(a), §2.1051                    6.5                       Spurious emissions at antenna terminals                   NP
   §24.238(a), §2.1053                    6.5                       Spurious radiated emissions                               PASSED
   §2.1055(a)                             6.3                       Frequency stability, temperature variation                NP
   §2.1055(d)                             6.3                       Frequency stability, voltage variation                    NP


PASSED                               The EUT complies with the essential requirements in the standard.
FAILED                               The EUT does not comply with the essential requirements in the standard.
NP                                   The test was not performed by the TCC Microsoft Laboratory.



FCC Part 22 Compliance Test Report                                                             TCC Microsoft Beijing Laboratory
/ Template Version 15.0                                             2 (9)                      Beijing Economic and
                                                                                               Technological Development Area
FCC_Cellular_RM‐1135_03                                                                        No.5 Donghuan Zhonglu
Copyright © TCC Microsoft                                                                      Beijing
                                                                                               PRC China 100176
                                                                                               Tel. +86 10 8711 8888
                                                                                               Fax. +86 10 8711 4550


CONTENTS


1.     Summary for FCC Part 22/24 Compliance Test Report .......................................... 2
1.1.      EUT and Accessory Information ...........................................................................................................2
1.2.      Summary of Test Results .....................................................................................................................2
2. Spurious radiated emissions
(FCC §22.917(a), §24.238(a), §2.1053, §2.1053, RSS-132 4.5, RSS-133 6.5) ................. 4
2.2.      Test method and limit ...........................................................................................................................4
2.3.      GSM 850 test results ............................................................................................................................6
2.4.      GSM 1900 test results ..........................................................................................................................6
3.     Test Equipment .......................................................................................................... 7
3.1.      Conducted measurements ...................................................................................................................7
3.2.      Radiated measurements ......................................................................................................................7




FCC Part 22 Compliance Test Report                                                                              TCC Microsoft Beijing Laboratory
/ Template Version 15.0                                                      3 (9)                              Beijing Economic and
                                                                                                                Technological Development Area
FCC_Cellular_RM‐1135_03                                                                                         No.5 Donghuan Zhonglu
Copyright © TCC Microsoft                                                                                       Beijing
                                                                                                                PRC China 100176
                                                                                                                Tel. +86 10 8711 8888
                                                                                                                Fax. +86 10 8711 4550


2.            Spurious radiated emissions
              (FCC §22.917(a), §24.238(a), §2.1053, §2.1053, RSS-132 4.5, RSS-133 6.5)

   EUT with DUT number                     RM-1135, DUT 55005
   Accessories with DUT numbers            BL-5CB, DUT 54985 ; AC-18E, DUT 54842 ; WH-108, DUT 54459
   Operation Voltage [V] / [Hz]            Nominal
   Results                                 PASSED
   Remarks                                 Test was done in Lab1
   Temp [oC] / Humidity [%RH] /
                                           23/51.3/101.1
   Air Pressure [kPa]
   Date of measurements                    03-Jun-2015
   Measured by                             Ma Emma

2.1.1      Test setup




              Communication
              Tester


                                     EUT
              Tower / table
              controller                                              Filter
                                                                      bank          Receiver




2.2.          Test method and limit
The measurement is made according to TIA-603-C-2004 as follows:

The measurement is divided into the Preliminary Measurement and the Final Measurement.

The suspected frequencies are searched for in Preliminary Measurement with absorbers on the floor and
measuring antenna at fixed height using 2-axis EUT position system.

The Final Measurement is performed in the Semi-Anechoic Chamber with conducting metal floor, if the
Preliminary Measurement results are closer than 20 dB to the permissible value.

The EUT is placed at nonconductive plate at the turntable center.

For each suspected frequency, the turntable is rotated 360 degrees and antenna is scanned from 1 to 4 m.
This is repeated for both horizontal and vertical receive antenna polarizations.

The emissions less than 20 dB below the permissible value are reported.
The substitution method is used. Substitution values at each frequencies are measured beforehand and
saved to the test software.

The substitution corrections are obtained as described below:

           ASUBST = PSUBST_TX - PSUBST_RX - LSUBST_CABLES + GSUBST_TX_ANT


FCC Part 22 Compliance Test Report                                             TCC Microsoft Beijing Laboratory
/ Template Version 15.0                                    4 (9)               Beijing Economic and
                                                                               Technological Development Area
FCC_Cellular_RM‐1135_03                                                        No.5 Donghuan Zhonglu
Copyright © TCC Microsoft                                                      Beijing
                                                                               PRC China 100176
                                                                               Tel. +86 10 8711 8888
                                                                               Fax. +86 10 8711 4550


Where ASUBST is the final substitution correction including receive antenna gain. PSUBST_TX is signal
generator level, PSUBST_RX is receiver level, LSUBST_CABLES is cable losses including both TX and
RX cables and GSUBST_TX_ANT is substitution antenna gain.

The measurement results are obtained as described below:

           P [dBm] = PMEAS + ATOT

Where PMEAS is receiver reading in dBm and ATOT is total correction factor including cable loss,
preamplifier gain and substitution correction (ATOT = LCABLES - GPREAMP + ASUBST).

Limits for spurious radiated emissions measurements
            Operation band           Frequency range [MHz]               Limit [dBm]
                 GSM 850                   30 - 8500                         -13
                GSM 1900                  30 - 19100                         -13
              WCDMA 850                    30 - 8500                         -13
                    LTE7                  30 - 25700                         -13




FCC Part 22 Compliance Test Report                                          TCC Microsoft Beijing Laboratory
/ Template Version 15.0                                5 (9)                Beijing Economic and
                                                                            Technological Development Area
FCC_Cellular_RM‐1135_03                                                     No.5 Donghuan Zhonglu
Copyright © TCC Microsoft                                                   Beijing
                                                                            PRC China 100176
                                                                            Tel. +86 10 8711 8888
                                                                            Fax. +86 10 8711 4550


2.3.          GSM 850 test results

Channel 190 / 836.6 MHz

Peak detector
    Frequency [MHz]                  P [dBm]   P [µW]    PMEAS [dBm]   ATOT [dB]       Polarisation               Results

           854.412                   -76.47     2E-05      -74.87        -1.6         HORIZONTAL                  PASSED
          1673.226                   -49.82    0.01042     -55.02         5.2          VERTICAL                   PASSED
          1673.267                   -46.73    0.02123     -52.13         5.4         HORIZONTAL                  PASSED
           2509.9                     -47.1     0.0195      -58.8        11.7         HORIZONTAL                  PASSED
          3346.333                   -53.01     0.005      -60.71         7.7         HORIZONTAL                  PASSED
*Substitution method could not be utilized as no emissions above noise floor were found during
measurements.


2.4.          GSM 1900 test results

Channel 661 / 1880.0 MHz

Peak detector
    Frequency [MHz]                  P [dBm]   P [µW]    PMEAS [dBm]   ATOT [dB]       Polarisation               Results

          2417.087                   -50.14    0.00968     -64.04        13.9          VERTICAL                   PASSED
          2419.299                   -49.29    0.01178     -63.49        14.2         HORIZONTAL                  PASSED
          2467.036                   -49.53    0.01114     -64.13        14.6         HORIZONTAL                  PASSED
          9729.419                   -42.19    0.06039     -67.79        25.6          VERTICAL                   PASSED
          9867.415                    -42.2    0.06026      -68.1        25.9         HORIZONTAL                  PASSED
          9992.256                   -42.55    0.05559     -68.15        25.6         HORIZONTAL                  PASSED
*Substitution method could not be utilized as no emissions above noise floor were found during
measurements.




FCC Part 22 Compliance Test Report                                                 TCC Microsoft Beijing Laboratory
/ Template Version 15.0                                     6 (9)                  Beijing Economic and
                                                                                   Technological Development Area
FCC_Cellular_RM‐1135_03                                                            No.5 Donghuan Zhonglu
Copyright © TCC Microsoft                                                          Beijing
                                                                                   PRC China 100176
                                                                                   Tel. +86 10 8711 8888
                                                                                   Fax. +86 10 8711 4550


3.            Test Equipment
3.1.          Conducted measurements
  Eq. No                    Equipment                      Type                  Manufacturer              Used in
  -                         BT / WLAN Antenna              SPA 2400/75/9/0/V     Huber-Suhner              15C, 15B
  -                         BT / WLAN Antenna              SPA 2400/75/9/0/V     Huber-Suhner              15C, 15B
  -                         RF Emission Software           EMC32 Test Software   R&S                       22/24/27, 15C, 15B
  BJPCHW0020                DC Power supply                Hp6632B               HP                        22/24/27, 15C
  BJPCPT0040                Receiver                       ESCS30                R&S                       15C,15B
  BJPCPT0069                LISN 50 µH                     ESH3-Z5               R&S                       15C,15B
  BJPCTC0323                Signal Generator               SMR 27                R&S                       22/24/27, 15C, 15B
  BJPCPT0073                Signal Generator               SMR 20                R&S                       22/24/27, 15C, 15B
  BJPCPT0191                Pulse Limiter                  ESH3-Z2               R&S                       15C,15B
  BJPCPT0208                UPS                            PULSAR RX10           Merlin gerin              15C.15B
  BJPCTC0001                DIGITAL CAMERA                 PC1015                CANON                     15C.15R
  BJPCTC0017                Communication Tester           CMU200                R&S                       22/24/27, 15C, 15B
  BJPCTC0062                AC Power source                6812B                 Hp                        15C.15B
  BJPCTC0067                Bluetooth Tester               CBT                   R&S                       22/24/27, 15C
  BJPCTC0082                Humidity and Temperature       175-H2                Testo                     15B,15C
                            Sensor
  BJPCTC0088                Absolut pressure meter         testo 511             Testo                     22/24/27, 15B,15C
  BJPCTC0089                Tempreture Test chamber        VT4002                Votsch                    22/24/27, 15C
                                                                                 industrietechnik
  BJPCTC0090                FSP spectrum analyzer          FSP30                 R&S                       22/24/27, 15C
  BJPCTC0094                GPIB-RS232 convertor           GPIB-RS232            NI                        22/24/27, 15C
  BJPCTC0112                Power Splitter                 11667B                Agilent                   22/24/27, 15C
  BJPCTC0115                Communication Tester           CMU200                R&S                       22/24/27, 15B, 15C
  BJPCTC0127                AC Power source                SOYI-500VA            SOYI                      15B 15C
  BJPCTC0128                Communication antenna          JXTXLB-10180          A-INFOMW                  22/24/27 15B 15C
  BJPCTC0129                Communication antenna          JXTXLB-10180          A-INFOMW                  22/24/27 15B 15C
  BJPCTC0131                Communication tester           CMW500                R&S                       22/24/27 15B 15C
  BJPCTC0136                Communication antenna          JXTXLB-880-NF         A-INFOMW                  15B 15C
  BJPCTC0306                Power Splitter                 11667B                Agilent                   22/24/27, 15C
  BJPCTC0305                GPIB converter                 GPIB-RS232            NI                        22/24/27, 15C
  BJPCTC0304                Spectrum Analyser              FSV30                 R&S                       22/24/27, 15C
  BJPCTC0309                GPIB-RS232 convertor           RS232                 NI                        22/24/27, 15C
  BJPCTC0307                Dual channel battery/charger   2306                  KEITHLEY                  22/24/27, 15C
                            simulator
  BJPCTC0308                Dual channel battery/charger   2306                  KEITHLEY                  22/24/27, 15C
                            simulator
  BJPCTC0352                Signal Generator 20GHz         MG3692B               Anritsu                   22/24/27, 15C
  BJBDATC0169               Tempreture Test chamber        VT4002                Votsch                    22/24/27, 15C
  BJPCTC0334                Communication Tester           CMU200                R&S                       22/24/27, 15C, 15B
  BJPCTC0342                Communication Tester           CMU200                R&S                        15B, 15C
  BJPCTC0343                Power Spliter                  1167A                 Agilent                   EN300328
  BJPCTC0344                Power Spliter                  1167A                 Agilent                   EN300328
  BJPCTC0345                Power Spliter                  1167A                 Agilent                   EN300328
  BJPCTC0346                Attenuator                     8496A                 Agilent                   EN300328
  BJPCTC0347                Directional Coupler            4226-20               Narda                     EN300328
  BJPCTC0348                Signal generator               E4438C                Agilent                   EN300328
  BJPCTC0336                Signal Generator               SMP22                 R&S                       22/24/27, 15C
  BJPCTC0357                Signal Generator               SMB100A               R&S                       -



3.2.          Radiated measurements
  Eq. No                    Equipment                      Type                  Manufacturer              Used in
  -                         BT / WLAN Antenna              SPA 2400/75/9/0/V     Huber-Suhner              15C, 15B
  -                         BT / WLAN Antenna              SPA 2400/75/9/0/V     Huber-Suhner              15C, 15B
  -                         RF Emission Software           EMC32 Test Software   R&S                       22/24/27, 15C, 15B
FCC Part 22 Compliance Test Report                                                     TCC Microsoft Beijing Laboratory
/ Template Version 15.0                                           7 (9)                Beijing Economic and
                                                                                       Technological Development Area
FCC_Cellular_RM‐1135_03                                                                No.5 Donghuan Zhonglu
Copyright © TCC Microsoft                                                              Beijing
                                                                                       PRC China 100176
                                                                                       Tel. +86 10 8711 8888
                                                                                       Fax. +86 10 8711 4550


  Eq. No                    Equipment                     Type                       Manufacturer                Used in
  BJPCPT0072                Receiver                      ESI B26                    R&S                         22/24/27, 15C, 15B
  BJPCPT0150                High Pass Filter              WHKS1200-10SS              Wainwright                  22/24/27, 15C, 15B
  BJPCPT0151                Band Reject Filter            WRCD1880/2000-0.2/40-      Wainwright                  24, 15B
                                                          5SSK
  BJPCPT0154                Band Reject Filter            WRCT2402/2480-             Wainwright                  15C, 15B
                                                          2400/2483.5-30-20SS
  BJPCPT0166                Antenna                       VUBA 9117                  Swarzbeck                   22/24/27
  BJPCPT0208                UPS                           PULSAR RX10                Merlin gerin                15C.15B
  BJPCTC0001                DIGITAL CAMERA                PC1015                     CANON                       15C.15R
  BJPCTC0007                Antenna                       HL562                      R&S                         22/24/27, 15C, 15B
  BJPCTC0029                Antenna                       HF906                      R&S                         22/24/27, 15C, 15B
  BJPCTC0034                Band Reject Filter            WRCT 800/880-0.2/40-       Wainwright                  22, 15B
                                                          5SSK
  BJPCTC0049                Preamplifier                  Blma 0118-1A-Bt            Bonn                        22/24/27, 15C, 15B
  BJPCTC0055                Communication Tester          CMU200                     R&S                         22/24/27,15C,15B
  BJPCTC0058                Bluetooth Tester              CBT                        R&S                         15C, 15B
  BJPCTC0062                AC Power source               6812B                      Hp                          15C.15B
  BJPCTC0064                Band Reject Filter            WRCG1877/1883-             Wainwright                  24, 15B
                                                          1870/1890-40/6SS
  BJPCTC0071                Multi-Device Controller       2090                       EMCO                        22/24/27, 15C, 15B
  BJPCTC0072                Anechoic Chamber              3 m Semi / Full Anechoic   ETS                         22/24/27, 15C, 15B
                                                          Chamber
  BJPCTC0073                MAST                          Model-TR/POL               ETS                         22/24/27, 15C, 15B
  BJPCTC0074                MAST                          Model 2070-2               ETS                         22/24/27, 15C, 15B
  BJPCTC0075                Turntable                     Model 2188                 ETS-EMCO                    22/24/27, 15C, 15B
  BJPCTC0081                Humidity and Temperature      175-H2                     Testo                       15B, 15C
                            Sensor
  BJPCTC0088                Absolut pressure meter        testo 511                  Testo                       22/24/27, 15B,15C
  BJPCTC0115                Communication Tester          CMU200                     R&S                         22/24/27, 15B, 15C
  BJPCTC0124                Attenuator                    SA18N200W-40               Fairview Microwave          -
  BJPCTC0125                Loop Antenna                  HFH2-Z2                    R&S                         15C
  BJPCTC0126                Tripod                        FHU-Z                      R&S                         15C
  BJPCTC0128                Communication antenna         JXTXLB-10180               A-INFOMW                    22/24/27 15B 15C
  BJPCTC0129                Communication antenna         JXTXLB-10180               A-INFOMW                    22/24/27 15B 15C
  BJPCTC0131                Communication tester          CMW500                     R&S                         22/24/27 15B 15C
  BJPCTC0133                Open Swith and contril unit   OSP 150                    R&S                         15B,15C
  BJPCTC0134                Open Swith and contril unit   OSP 150                    R&S                         15B,15C
  BJPCTC0135                Open Swith and contril unit   OSP 130                    R&S                         15B,15C
  BJPCTC0136                Communication antenna         JXTXLB-880-NF              A-INFOMW                    15B 15C
  BJPCTC0171                Broad-band Horn Antenna       BBHA9120 D                 SCHWARZBECK                 22/24/27, 15C, 15B
                                                                                     MESS -
                                                                                     ELEKTRONIK
  BJPCTC0310                Horn Antenna                  QSH20SMA                   Q-par                       22/24/27, 15C, 15B
  BJPCTC0311                Horn Antenna                  QSH18SMA                   Q-par                       22/24/27, 15C, 15B
  BJPCTC0312                Relay Switch Unit             -                          -                           22/24/27, 15C, 15B
  BJPCTC0313                High Pass Filter              WHKX1.0/15G-12SS           Wainwright                  22/24/27, 15C, 15B
  BJPCTC0314                High Pass Filter              WHKX8.0/18G-88SS           Wainwright                  22/24/27, 15C, 15B
  BJPCTC0315                High Pass Filter              WHKX3.0/18G-12SS           Wainwright                  22/24/27, 15C, 15B
  BJPCTC0316                Preamplifier                  AMT-5F-18002550-25-        -                           22/24/27, 15C, 15B
                                                          108
  BJPCTC0317                Preamplifier                  AMF-6D-02001800-29-        -                           22/24/27, 15C, 15B
                                                          20P
  BJPCTC0350                Preamplifier                  AMF-4D-01000800-30-        Miteq                       22/24/27, 15C, 15B
                                                          29P
  BJPCTC0324                Preamplifier                  AFS4-00100300-20-23P-      Miteq                       22/24/27, 15C, 15B
                                                          6
  BJPCTC0329                Relay Switch Unit             -                          -                           22/24/27, 15C, 15B
  BJPCTC0334                Communication Tester          CMU200                     R&S                         22/24/27, 15C, 15B
  BJPCTC0342                Communication Tester          CMU200                     R&S                          15B, 15C

FCC Part 22 Compliance Test Report                                                           TCC Microsoft Beijing Laboratory
/ Template Version 15.0                                        8 (9)                         Beijing Economic and
                                                                                             Technological Development Area
FCC_Cellular_RM‐1135_03                                                                      No.5 Donghuan Zhonglu
Copyright © TCC Microsoft                                                                    Beijing
                                                                                             PRC China 100176
                                                                                             Tel. +86 10 8711 8888
                                                                                             Fax. +86 10 8711 4550


  Eq. No                    Equipment      Type                  Manufacturer                Used in
  BJPCTC0349                Preamplifier   AMF-4D-01000800-30-   Miteg                       22/24/27, 15C, 15B
                                           79P
  BJPCTC0350                Preamplifier   AMF-4D-01000800-30-   Miteg                       22/24/27, 15C, 15B
                                           29P
  BJPCTC0351                Preamplifier   AFS4-00101800         -                           22/24/27, 15C, 15B
  BJPCTC0113                Receiver       ESI B26               R&S                         22/24/27, 15B, 15C




FCC Part 22 Compliance Test Report                                       TCC Microsoft Beijing Laboratory
/ Template Version 15.0                         9 (9)                    Beijing Economic and
                                                                         Technological Development Area
FCC_Cellular_RM‐1135_03                                                  No.5 Donghuan Zhonglu
Copyright © TCC Microsoft                                                Beijing
                                                                         PRC China 100176
                                                                         Tel. +86 10 8711 8888
                                                                         Fax. +86 10 8711 4550



Document Created: 2015-06-15 14:46:56
Document Modified: 2015-06-15 14:46:56

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC