SAR Report part 3

FCC ID: PY7PM-0611

RF Exposure Info

Download: PDF
FCCID_2230939

No. I14Z45356-SEM01
    Page 109 of 147


No. I14Z45356-SEM01
    Page 110 of 147


No. I14Z45356-SEM01
     Page 111 of 147


No. I14Z45356-SEM01
    Page 112 of 147


No. I14Z45356-SEM01
    Page 113 of 147


No. I14Z45356-SEM01
    Page 114 of 147


No. I14Z45356-SEM01
    Page 115 of 147


TME

Calibration Laboratory of                                                                                   s       Schweizerischer Kalibrierdienst
Schmid & Partner                                                                                            c       Service suisse d‘étalonnage
  Engineering AG                                                                                                    Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                        Swiss Calibration Service



 Accredited by the Swiss Accreditation Service (SAS)                                            Accreditation No.: SCS 108
 The Swiss Accreditation Service is one of the signatories to the EA
 Multilateral Agreement for the recagnition of calibration certificates

 Client      TMC—BJ (Auden)                                                                     Certificate No: D1900V2—50101_Jul13

|CALIBRATION CERTIFICATE
 Object                                D1900V2 — SN: 5d101


 Calibration procedure(s)              QA CAL—05.v9
                                       Calibration procedure for dipole validation kits above 700 MHz



  Calibration date:                    July 69, 2013



  This calibration certificate documents the traceabilty to national standards, which realize the physical units of measurements (S1).
  The measurements and the uncertainties with confidence probablity are given on the following pages and are part of the certficate.

  All callbrations have been conducted in the closed laboratory faciity: environment temperature (22 a 3)°C and humidity < 70%.


  Calibration Equipment used (M&TE eritical for calibration)


  Primary Standards                      1D A                      Cal Date (Certificate No.)                            Scheduled Calibration
  Power meter EPM—442A                   Ga37480704                01—Nov—12 (No. 217—01640)                             Oct—13
  Power sensor HP 8481A                  Us37202783                01—Nav—12 (No. 217—01640)                             Oct—13
  Reference 20 dB Aftenuator             SN: 5058 (20k)            04—Apr—18 (No. 217—01736)                             Aprts
  Type—N mismatch combination            SN: 5047.3 / 06327        O4—Apr—18 (No. 217—01739)                             Apriis
  Reference Probe ESSDV3                 SN: 3205                  28—Dac—12 (No. ES9—3205_Dec12)                        Dec—13
  DAE4                                   SN: so1                   25—Apr—13 (No. DAE4—601_Apr13)                        Aprits

  Secondary Standards                    1D #                      Check Date (in house)                                 Scheduted Check
  Power sensor HP 8481A                  MY41002317                18—0ct—02 (in house chack Oct—11)                     in house check: Oct—13
  RF generator R&S SMT—08                100006                    04—Aug—99 (in house check Oct—11)                     In house check: Oct—18
  Network Analyzer HP 8758E              Uss7390585 4206           18—0ct—01 (in house check Oct—12)                     In house check: Oct—13




                                                                                                                       sip>"
                                         Name                                   Function
  Calibrated by:                         Leif Kiysner                           Laboratory Tachnician



  Approved by:
                                                                                                                     o
                                         Katia Pokovie                          Technical Manager



                                                                                                                         Issued: July 9, 2013
  This calibration certificate shall not be reproducad except in full without written approval of the laboratory.


 Certificate No: D1900V2—5d101_Jul13                                   Page 1 of 8