RF Exposure Info._20170207_v1 - PY7-84773W_FCC RFExp_Appendix A

FCC ID: PY7-84773W

RF Exposure Info

Download: PDF
FCCID_3286198

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab    Date: 2016/10/20


System Check_Head_835MHz
DUT: D835V2­4d200

Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium: HSL_850_161020 Medium parameters used: f = 835 MHz; σ = 0.892 S/m; εr = 43.176; ρ =
1000 kg/m3
A i T                  :23.4 ℃; Li i T                   :22.4 ℃

DASY5 Configuration
­ Probe: EX3DV4 ­ SN3820; ConvF(9, 9, 9); Calibrated: 2016/6/27;
­ Sensor­Surface: 1.4mm (Mechanical Surface Detection)
­ Electronics: DAE4 Sn679; Calibrated: 2016/6/13
­ Phantom: SAM_Left; Type: QD000P40CD; Serial: S/N:1796
­ Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7373)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 3.27 W/kg

Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 62.11 V/m; Power Drift = ­0.02 dB
Peak SAR (extrapolated) = 3.61 W/kg
SAR(1 g) = 2.46 W/kg; SAR(10 g) = 1.66 W/kg
Maximum value of SAR (measured) = 3.18 W/kg




               0 dB = 3.18 W/kg = 5.02 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab    Date: 2016/10/20


System Check_Body_835MHz
DUT: D835V2­4d200

Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium: MSL_850_161020 Medium parameters used: f = 835 MHz; σ = 0.979 S/m; εr = 56.473; ρ =
1000 kg/m3
A i T                  :23.8 ℃; Li i T                   :22.8 ℃

DASY5 Configuration
­ Probe: EX3DV4 ­ SN3820; ConvF(8.86, 8.86, 8.86); Calibrated: 2016/6/27;
­ Sensor­Surface: 1.4mm (Mechanical Surface Detection)
­ Electronics: DAE4 Sn679; Calibrated: 2016/6/13
­ Phantom: SAM_Left; Type: QD000P40CD; Serial: S/N:1796
­ Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7373)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 3.45 W/kg

Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 60.83 V/m; Power Drift = ­0.04 dB
Peak SAR (extrapolated) = 3.81 W/kg
SAR(1 g) = 2.59 W/kg; SAR(10 g) = 1.72 W/kg
Maximum value of SAR (measured) = 3.39 W/kg




               0 dB = 3.39 W/kg = 5.30 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab    Date: 2016/10/21


System Check_Head_1900MHz
DUT: D1900V2­5d210

Communication System: CW; Frequency: 1900 MHz;Duty Cycle: 1:1
Medium: HSL_1900_161021 Medium parameters used: f = 1900 MHz; σ = 1.416 S/m; εr = 41.59; ρ =
1000 kg/m3
A i T                  :23.6 ℃; Li i T                   :22.6 ℃

DASY5 Configuration
­ Probe: EX3DV4 ­ SN3820; ConvF(7.8, 7.8, 7.8); Calibrated: 2016/6/27;
­ Sensor­Surface: 1.4mm (Mechanical Surface Detection)
­ Electronics: DAE4 Sn679; Calibrated: 2016/6/13
­ Phantom: SAM_Left; Type: QD000P40CD; Serial: S/N:1796
­ Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7373)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 15.0 W/kg

Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 103.2 V/m; Power Drift = ­0.01 dB
Peak SAR (extrapolated) = 17.6 W/kg
SAR(1 g) = 9.69 W/kg; SAR(10 g) = 5.16 W/kg
Maximum value of SAR (measured) = 14.6 W/kg




               0 dB = 14.6 W/kg = 11.64 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab    Date: 2016/10/17


System Check_Body_1900MHz
DUT: D1900V2­5d210

Communication System: CW; Frequency: 1900 MHz;Duty Cycle: 1:1
Medium: MSL_1900_161017 Medium parameters used: f = 1900 MHz; σ = 1.55 S/m; εr = 55.257; ρ
= 1000 kg/m3
A i T                  :23.3 ℃; Li i T                   :22.3 ℃

DASY5 Configuration
­ Probe: EX3DV4 ­ SN3820; ConvF(7.41, 7.41, 7.41); Calibrated: 2016/6/27;
­ Sensor­Surface: 1.4mm (Mechanical Surface Detection)
­ Electronics: DAE4 Sn679; Calibrated: 2016/6/13
­ Phantom: SAM_Right; Type: QD000P40CD; Serial: S/N:1801
­ Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7373)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 15.1 W/kg

Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 102.2 V/m; Power Drift = ­0.15 dB
Peak SAR (extrapolated) = 17.7 W/kg
SAR(1 g) = 10 W/kg; SAR(10 g) = 5.37 W/kg
Maximum value of SAR (measured) = 14.9 W/kg




               0 dB = 14.9 W/kg = 11.73 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab    Date: 2016/10/19


System Check_Body_1900MHz
DUT: D1900V2­5d210

Communication System: CW; Frequency: 1900 MHz;Duty Cycle: 1:1
Medium: MSL_1900_161019 Medium parameters used: f = 1900 MHz; σ = 1.518 S/m; εr = 54.712; ρ
= 1000 kg/m3
A i T                  :23.2 ℃; Li i T                   :22.2 ℃

DASY5 Configuration
­ Probe: EX3DV4 ­ SN3820; ConvF(7.41, 7.41, 7.41); Calibrated: 2016/6/27;
­ Sensor­Surface: 1.4mm (Mechanical Surface Detection)
­ Electronics: DAE4 Sn679; Calibrated: 2016/6/13
­ Phantom: SAM_Left; Type: QD000P40CD; Serial: S/N:1796
­ Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7373)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 15.2 W/kg

Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 102.2 V/m; Power Drift = ­0.03 dB
Peak SAR (extrapolated) = 17.7 W/kg
SAR(1 g) = 10.1 W/kg; SAR(10 g) = 5.43 W/kg
Maximum value of SAR (measured) = 14.9 W/kg




               0 dB = 14.9 W/kg = 11.73 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab    Date: 2016/11/3


System Check_Head_2450MHz
DUT: D2450V2­926

Communication System: CW; Frequency: 2450 MHz;Duty Cycle: 1:1
Medium: HSL_2450_161103 Medium parameters used: f = 2450 MHz; σ = 1.798 S/m; εr = 39.866; ρ
= 1000 kg/m3
A i T                  :23.5 ℃; Li i T                   :22.5 ℃

DASY5 Configuration
­ Probe: EX3DV4 ­ SN3931; ConvF(7.6, 7.6, 7.6); Calibrated: 2016/10/3;
­ Sensor­Surface: 1.4mm (Mechanical Surface Detection)
­ Electronics: DAE3 Sn577; Calibrated: 2016/9/28
­ Phantom: SAM_Right; Type: QD000P40CD; Serial: S/N:1801
­ Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7373)


Pin=250mW/Area Scan (71x71x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 20.4 W/kg

Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 114.9 V/m; Power Drift = 0.10 dB
Peak SAR (extrapolated) = 28.1 W/kg
SAR(1 g) = 13.4 W/kg; SAR(10 g) = 6.25 W/kg
Maximum value of SAR (measured) = 22.6 W/kg




               0 dB = 22.6 W/kg = 13.54 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab    Date: 2016/11/3


System Check_Body_2450MHz
DUT: D2450V2­926

Communication System: CW ; Frequency: 2450 MHz;Duty Cycle: 1:1
Medium: MSL_2450_161103 Medium parameters used: f = 2450 MHz; σ = 1.899 S/m; εr = 52.183; ρ
= 1000 kg/m3
A i T                  :23.5 ℃; Li i T                   :22.5 ℃

DASY5 Configuration
­ Probe: EX3DV4 ­ SN3820; ConvF(6.79, 6.79, 6.79); Calibrated: 2016/6/27;
­ Sensor­Surface: 1.4mm (Mechanical Surface Detection)
­ Electronics: DAE4 Sn679; Calibrated: 2016/6/13
­ Phantom: SAM_Left; Type: QD000P40CD; Serial: S/N:1796
­ Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7373)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 20.3 W/kg

Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 105.1 V/m; Power Drift = ­0.19 dB
Peak SAR (extrapolated) = 23.8 W/kg
SAR(1 g) = 12.5 W/kg; SAR(10 g) = 6.12 W/kg
Maximum value of SAR (measured) = 19.9 W/kg




               0 dB = 19.9 W/kg = 12.99 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab    Date: 2016/11/3


System Check_Body_2450MHz
DUT: D2450V2­926

Communication System: CW ; Frequency: 2450 MHz;Duty Cycle: 1:1
Medium: MSL_2450_161103 Medium parameters used: f = 2450 MHz; σ = 1.899 S/m; εr = 52.183; ρ
= 1000 kg/m3
A i T                  :23.5 ℃; Li i T                   :22.5 ℃

DASY5 Configuration
­ Probe: EX3DV4 ­ SN3931; ConvF(7.73, 7.73, 7.73); Calibrated: 2016/10/3;
­ Sensor­Surface: 1.4mm (Mechanical Surface Detection)
­ Electronics: DAE3 Sn577; Calibrated: 2016/9/28
­ Phantom: SAM_Left; Type: QD000P40CD; Serial: S/N:1796
­ Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7373)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 20.5 W/kg

Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 107.2 V/m; Power Drift = ­0.14 dB
Peak SAR (extrapolated) = 24.5 W/kg
SAR(1 g) = 12.2 W/kg; SAR(10 g) = 5.79 W/kg
Maximum value of SAR (measured) = 20.2 W/kg




               0 dB = 20.2 W/kg = 13.05 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab    Date: 2016/10/21


System Check_Head_2600MHz
DUT: D2600V2­1113

Communication System: CW; Frequency: 2600 MHz;Duty Cycle: 1:1
Medium: HSL_2600_161021 Medium parameters used: f = 2600 MHz; σ = 1.924 S/m; εr = 38.52; ρ =
1000 kg/m3
A i T                  :23.2 ℃; Li i T                   :22.2 ℃

DASY5 Configuration
­ Probe: EX3DV4 ­ SN3820; ConvF(6.49, 6.49, 6.49); Calibrated: 2016/6/27;
­ Sensor­Surface: 1.4mm (Mechanical Surface Detection)
­ Electronics: DAE4 Sn679; Calibrated: 2016/6/13
­ Phantom: SAM_Right; Type: QD000P40CD; Serial: S/N:1801
­ Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7373)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 23.6 W/kg

Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 107.3 V/m; Power Drift = ­0.01 dB
Peak SAR (extrapolated) = 29.0 W/kg
SAR(1 g) = 14.1 W/kg; SAR(10 g) = 6.55 W/kg
Maximum value of SAR (measured) = 23.4 W/kg




               0 dB = 23.4 W/kg = 13.69 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab    Date: 2016/10/18


System Check_Body_2600MHz
DUT: D2600V2­1113

Communication System: CW; Frequency: 2600 MHz;Duty Cycle: 1:1
Medium: MSL_2600_161018 Medium parameters used: f = 2600 MHz; σ = 2.154 S/m; εr = 52.74; ρ
= 1000 kg/m3
A i T                  :23.6 ℃; Li i T                   :22.6 ℃

DASY5 Configuration
­ Probe: EX3DV4 ­ SN3820; ConvF(6.52, 6.52, 6.52); Calibrated: 2016/6/27;
­ Sensor­Surface: 1.4mm (Mechanical Surface Detection)
­ Electronics: DAE4 Sn679; Calibrated: 2016/6/13
­ Phantom: SAM_Left; Type: QD000P40CD; Serial: S/N:1796
­ Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7373)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 23.6 W/kg

Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 107.7 V/m; Power Drift = ­0.04 dB
Peak SAR (extrapolated) = 29.3 W/kg
SAR(1 g) = 14.4 W/kg; SAR(10 g) = 6.63 W/kg
Maximum value of SAR (measured) = 23.7 W/kg




               0 dB = 23.7 W/kg = 13.75 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab    Date: 2016/10/20


System Check_Body_2600MHz
DUT: D2600V2­1113

Communication System: CW; Frequency: 2600 MHz;Duty Cycle: 1:1
Medium: MSL_2600_161020 Medium parameters used: f = 2600 MHz; σ = 2.151 S/m; εr = 52.823; ρ
= 1000 kg/m3
A i T                  :23.7 ℃; Li i T                   :22.7 ℃

DASY5 Configuration
­ Probe: EX3DV4 ­ SN3820; ConvF(6.52, 6.52, 6.52); Calibrated: 2016/6/27;
­ Sensor­Surface: 1.4mm (Mechanical Surface Detection)
­ Electronics: DAE4 Sn679; Calibrated: 2016/6/13
­ Phantom: SAM_Right; Type: QD000P40CD; Serial: S/N:1801
­ Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7373)


Pin=250mW/Area Scan (61x61x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 23.3 W/kg

Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 108.1 V/m; Power Drift = ­0.12 dB
Peak SAR (extrapolated) = 28.5 W/kg
SAR(1 g) = 14.1 W/kg; SAR(10 g) = 6.51 W/kg
Maximum value of SAR (measured) = 23.4 W/kg




               0 dB = 23.4 W/kg = 13.69 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab    Date: 2016/10/24


System Check_Head_5300MHz
DUT: D5GHzV2­1040

Communication System: CW; Frequency: 5300 MHz;Duty Cycle: 1:1
Medium: HSL_5G_161024 Medium parameters used: f = 5300 MHz; σ = 4.712 S/m; εr = 37.267; ρ =
1000 kg/m3
A i T                  :23.5 ℃; Li i T                   :22.5 ℃

DASY5 Configuration
­ Probe: EX3DV4 ­ SN3820; ConvF(4.41, 4.41, 4.41); Calibrated: 2016/6/27;
­ Sensor­Surface: 1.4mm (Mechanical Surface Detection)
­ Electronics: DAE4 Sn679; Calibrated: 2016/6/13
­ Phantom: SAM_Right; Type: QD000P40CD; Serial: S/N:1801
­ Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7373)


Pin=100mW/Area Scan (71x71x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 18.8 W/kg

Pin=100mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 68.21 V/m; Power Drift = ­0.02 dB
Peak SAR (extrapolated) = 30.9 W/kg
SAR(1 g) = 8.41 W/kg; SAR(10 g) = 2.53 W/kg
Maximum value of SAR (measured) = 19.3 W/kg




               0 dB = 19.3 W/kg = 12.86 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab    Date: 2016/10/26


System Check_Body_5300MHz
DUT: D5GHzV2­1040

Communication System: CW ; Frequency: 5300 MHz;Duty Cycle: 1:1
Medium: MSL_5G_161026 Medium parameters used: f = 5300 MHz; σ = 5.592 S/m; εr = 46.846; ρ =
1000 kg/m3
A i T                  :23.5 ℃; Li i T                   :22.5 ℃

DASY5 Configuration
­ Probe: EX3DV4 ­ SN3820; ConvF(3.95, 3.95, 3.95); Calibrated: 2016/6/27;
­ Sensor­Surface: 1.4mm (Mechanical Surface Detection)
­ Electronics: DAE4 Sn679; Calibrated: 2016/6/13
­ Phantom: SAM_Right; Type: QD000P40CD; Serial: S/N:1801
­ Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7373)


Pin=100mW/Area Scan (71x71x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 17.7 W/kg

Pin=100mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 67.67 V/m; Power Drift = ­0.01 dB
Peak SAR (extrapolated) = 29.0 W/kg
SAR(1 g) = 8.09 W/kg; SAR(10 g) = 2.29 W/kg
Maximum value of SAR (measured) = 18.6 W/kg




               0 dB = 18.6 W/kg = 12.70 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab    Date: 2016/10/24


System Check_Head_5600MHz
DUT: D5GHzV2­1040

Communication System: CW; Frequency: 5600 MHz;Duty Cycle: 1:1
Medium: HSL_5G_161024 Medium parameters used: f = 5600 MHz; σ = 5.019 S/m; εr = 36.838; ρ =
1000 kg/m3
A i T                  :23.5 ℃; Li i T                   :22.5 ℃

DASY5 Configuration
­ Probe: EX3DV4 ­ SN3820; ConvF(4.14, 4.14, 4.14); Calibrated: 2016/6/27;
­ Sensor­Surface: 1.4mm (Mechanical Surface Detection)
­ Electronics: DAE4 Sn679; Calibrated: 2016/6/13
­ Phantom: SAM_Right; Type: QD000P40CD; Serial: S/N:1801
­ Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7373)


Pin=100mW/Area Scan (71x71x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 18.7 W/kg

Pin=100mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 68.12 V/m; Power Drift = 0.08 dB
Peak SAR (extrapolated) = 31.9 W/kg
SAR(1 g) = 8.04 W/kg; SAR(10 g) = 2.34 W/kg
Maximum value of SAR (measured) = 19.1 W/kg




               0 dB = 19.1 W/kg = 12.81 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab    Date: 2016/10/26


System Check_Body_5600MHz
DUT: D5GHzV2­1040

Communication System: CW; Frequency: 5600 MHz;Duty Cycle: 1:1
Medium: MSL_5G_161026 Medium parameters used: f = 5600 MHz; σ = 5.989 S/m; εr = 46.334; ρ =
1000 kg/m3
A i T                  :23.5 ℃; Li i T                   :22.5 ℃

DASY5 Configuration
­ Probe: EX3DV4 ­ SN3820; ConvF(3.54, 3.54, 3.54); Calibrated: 2016/6/27;
­ Sensor­Surface: 1.4mm (Mechanical Surface Detection)
­ Electronics: DAE4 Sn679; Calibrated: 2016/6/13
­ Phantom: SAM_Right; Type: QD000P40CD; Serial: S/N:1801
­ Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7373)


Pin=100mW/Area Scan (71x71x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 20.2 W/kg

Pin=100mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 68.27 V/m; Power Drift = ­0.12 dB
Peak SAR (extrapolated) = 30.7 W/kg
SAR(1 g) = 7.72 W/kg; SAR(10 g) = 2.26 W/kg
Maximum value of SAR (measured) = 18.8 W/kg




               0 dB = 18.8 W/kg = 12.74 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab    Date: 2016/10/24


System Check_Head_5800MHz
DUT: D5GHzV2­1040

Communication System: CW; Frequency: 5800 MHz;Duty Cycle: 1:1
Medium: HSL_5G_161024 Medium parameters used: f = 5800 MHz; σ = 5.224 S/m; εr = 36.58; ρ =
1000 kg/m3
A i T                  :23.5 ℃; Li i T                   :22.5 ℃

DASY5 Configuration
­ Probe: EX3DV4 ­ SN3820; ConvF(4.14, 4.14, 4.14); Calibrated: 2016/6/27;
­ Sensor­Surface: 1.4mm (Mechanical Surface Detection)
­ Electronics: DAE4 Sn679; Calibrated: 2016/6/13
­ Phantom: SAM_Right; Type: QD000P40CD; Serial: S/N:1801
­ Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7373)


Pin=100mW/Area Scan (71x71x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 19.4 W/kg

Pin=100mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 68.12 V/m; Power Drift = ­0.18 dB
Peak SAR (extrapolated) = 31.2 W/kg
SAR(1 g) = 7.63 W/kg; SAR(10 g) = 2.25 W/kg
Maximum value of SAR (measured) = 18.3 W/kg




               0 dB = 18.3 W/kg = 12.62 dBW/kg


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab    Date: 2016/10/26


System Check_Body_5800MHz
DUT: D5GHzV2­1040

Communication System: CW; Frequency: 5800 MHz;Duty Cycle: 1:1
Medium: MSL_5G_161026 Medium parameters used: f = 5800 MHz; σ = 6.259 S/m; εr = 45.995; ρ =
1000 kg/m3
A i T                  :23.5 ℃; Li i T                   :22.5 ℃

DASY5 Configuration
­ Probe: EX3DV4 ­ SN3820; ConvF(3.7, 3.7, 3.7); Calibrated: 2016/6/27;
­ Sensor­Surface: 1.4mm (Mechanical Surface Detection)
­ Electronics: DAE4 Sn679; Calibrated: 2016/6/13
­ Phantom: SAM_Right; Type: QD000P40CD; Serial: S/N:1801
­ Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7373)


Pin=100mW/Area Scan (71x71x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 16.1 W/kg

Pin=100mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 61.71 V/m; Power Drift = ­0.02 dB
Peak SAR (extrapolated) = 27.7 W/kg
SAR(1 g) = 6.91 W/kg; SAR(10 g) = 2.04 W/kg
Maximum value of SAR (measured) = 17.0 W/kg




               0 dB = 17.0 W/kg = 12.30 dBW/kg