Test Report_20181223_v2 - ZR20189002706-15B, RPT

FCC ID: PY7-50241M

Test Report

Download: PDF
FCCID_4119235

                                                               SGS-CSTC Standards Technical Services Co., Ltd.
                                                               Shenzhen Branch

No. 1 Workshop, M-10, Middle section, Science & Technology Park,
Shenzhen, Guangdong, China 518057
Telephone:            +86 (0) 755 2601 2053                                                                                       Report No.: ZR/2018/9002706
Fax:                  +86 (0) 755 2671 0594
                                                                                                                                  Page:        1 of 24
Email:                ee.shenzhen@sgs.com




                                                                    TEST REPORT
Application No.:                                            ZR/2018/90027
Applicant:                                                  Sony Mobile Communications INC
Address of Applicant:                                       4-12-3 Higashi-shinagawa, Shinagawa-ku, Tokyo, 140-0002, Japan
Manufacturer:                                               Sony Mobile Communications Inc.
Address of Manufacturer:                                    4-12-3 Higashi-shinagawa, Shinagawa-ku, Tokyo, 140-0002, Japan
Factory:                                                    Dong Guan Huabel Electronic Technology Co., Ltd
Address of Factory:                                         No.9 Industrial Northern Road, National High-Tech Industrial Development
                                                            Zone, SongShan Lake, Dong Guan City
Equipment Under Test (EUT):
EUT Description:                                            Mobile Phone
FCC ID:                                                     PY7-50241M
Trade mark:                                                 Sony
Standard(s) :                                               47 CFR Part 15, Subpart B
Date of Receipt:                                            2018-10-17
Date of Test:                                               2018-10-19 to 2018-10-24
Date of Issue:                                              2018-12-14
Test Result:                                                Pass*
* In the configuration tested, the EUT complied with the standards specified above.




                   Keny Xu
             EMC Laboratory Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new
system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS International
Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS International
Electrical Approvals in writing.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       2 of 24


                                                                                            Revision Record
                 Version                    Chapter                                           Date                                        Modifier                               Remark

             Rev.00                                                                   2018-11-15                                                                                 Original
             Rev.01                                                                   2018-12-14                                                                               1st revised




       Authorized for issue by:




                                                                     Leo Lai /Project Engineer




                                                                     Eric Fu /Reviewer




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       3 of 24


2          Test Summary
            Emission Part
                              Item                               Standard                                    Method                                     Requirement                               Result
            Conducted Emissions
                                                           47 CFR Part 15,
             at Mains Terminals                                                                     ANSI C63.4:2014                                           Class B                               Pass
                                                              Subpart B
              (150kHz-30MHz)
              Radiated Emissions                           47 CFR Part 15,
                                                                                                    ANSI C63.4:2014                                           Class B                               Pass
                (30MHz-1GHz)                                  Subpart B
              Radiated Emissions                           47 CFR Part 15,
                                                                                                    ANSI C63.4:2014                                           Class B                               Pass
                (above 1GHz)                                  Subpart B


                       Internal Source                                                                                  Upper Frequency
                      Below 1.705MHz                                                                                               30MHz
                 1.705MHz to 108MHz                                                                                                 1GHz
                   108MHz to 500MHz                                                                                                 2GHz
                      500MHz to 1GHz                                                                                                5GHz
                          Above 1GHz                                     5th harmonic of the highest frequency or 40GHz, whichever is lower




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       4 of 24


3          Contents
                                                                                                                                                                                                     Page
1         COVER PAGE ............................................................................................................................................1

2         TEST SUMMARY .......................................................................................................................................3

3         CONTENTS ................................................................................................................................................4

4         GENERAL INFORMATION ........................................................................................................................5
     4.1            DETAILS OF E.U.T. ...............................................................................................................................5
     4.2            DESCRIPTION OF SUPPORT UNITS .........................................................................................................5
     4.3            MEASUREMENT UNCERTAINTY ..............................................................................................................5
     4.4            TEST LOCATION....................................................................................................................................6
     4.5            TEST FACILITY......................................................................................................................................6
     4.6            DEVIATION FROM STANDARDS ...............................................................................................................6
     4.7            ABNORMALITIES FROM STANDARD CONDITIONS .....................................................................................6
5         EQUIPMENT LIST ......................................................................................................................................7

6         EMISSION TEST RESULTS ......................................................................................................................9
     6.1     CONDUCTED EMISSIONS AT MAINS TERMINALS (150KHZ-30MHZ) ..........................................................9
        6.1.1 E.U.T. Operation ............................................................................................................................9
        6.1.2 Test Setup Diagram .......................................................................................................................9
        6.1.3 Measurement Data ........................................................................................................................9
     6.2     RADIATED EMISSIONS (30MHZ-1GHZ) ................................................................................................14
        6.2.1 E.U.T. Operation ..........................................................................................................................15
        6.2.2 Test Setup Diagram .....................................................................................................................15
        6.2.3 Measurement Data ......................................................................................................................15
     6.3     RADIATED EMISSIONS (ABOVE 1GHZ)..................................................................................................18
        6.3.1 E.U.T. Operation ..........................................................................................................................19
        6.3.2 Test Setup Diagram .....................................................................................................................19
        6.3.3 Measurement Data ......................................................................................................................19
7         PHOTOGRAPHS ......................................................................................................................................24
     7.1            TEST SETUP .......................................................................................................................................24
     7.2            EUT CONSTRUCTIONAL DETAILS (EUT PHOTOS).................................................................................24




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       5 of 24


4          General Information
4.1 Details of E.U.T.
           Power supply:                                    DC 3.85V from internal battery or AC/DC adapter
                                                            1. AC Adaptor: UCH20
                                                            2. Car Charger: AN430
           Cable:                                           Type C USB cable: Sony, AI-0162, 100cm shielded
                                                            Earphone cable: Sony, 110cm unshielded.


4.2 Description of Support Units
           Description                                             Manufacturer                                           Model No.                                          Serial No.
           Laptop                                                         Lenovo                                               T430u                                 REF. No.SEA1800
           Mouse                                                          Lenovo                                         M-U0025-O                                   REF. No.:SEA2400
           Router                                                     NETGEAR                                              DGN2200                                   REF. No.SEA2200


4.3 Measurement Uncertainty

                No.                                                      Item                                                             Measurement Uncertainty
                   1                                      Conduction Emission                                                             ± 3.0dB (150kHz to 30MHz)
                                                                                                                                            ± 4.5dB (30MHz-1GHz)
                   2                                        Radiated Emission
                                                                                                                                               ± 4.8dB (1GHz-6GHz)
                   3                                          Temperature test                                                                                 ± 1°C
                   4                                              Humidity test                                                                                 ± 3%




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       6 of 24

4.4 Test Location
            All tests were performed at:
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch
            No. 1 Workshop, M-10, Middle Section, Science & Technology Park, Shenzhen, Guangdong, China.
            518057.
            Tel: +86 755 2601 2053                                    Fax: +86 755 2671 0594
            No tests were sub-contracted.

4.5 Test Facility
            The test facility is recognized, certified, or accredited by the following organizations:
            • CNAS (No. CNAS L2929)
            CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
            Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
            Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
            Laboratories) for the competence in the field of testing.
            • A2LA (Certificate No. 3816.01)
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
            American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
            • VCCI
            The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
            Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
            Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
            been registered in accordance with the Regulations for Voluntary Control Measures with Registration
            No.: G-20026, R-14188, C-12383 and T-11153 respectively.
            • FCC –Designation Number: CN1178
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
            as an accredited testing laboratory.
            Designation Number: CN1178. Test Firm Registration Number: 406779.
            • Innovation, Science and Economic Development Canada
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
            by ISED as an accredited testing laboratory.
            CAB identifier: CN0006.
            IC#: 4620C.
4.6 Deviation from Standards
            None
4.7 Abnormalities from Standard Conditions
            None




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       7 of 24


5          Equipment List
Conducted Emissions at Mains Terminals (150kHz-30MHz)
            Equipment                                   Manufacturer                             Model No                   Inventory No                      Cal Date                Cal Due Date
        Shielding Room                           ChangZhou ZhongYu                                  GB-88                     SEM001-06                    2017-05-10                   2020-05-09
 Measurement Software                                          AUDIX                         e3 V5.4.1221d                            N/A                          N/A                         N/A
          Coaxial Cable                                          SGS                                   N/A                    SEM024-01                    2018-07-12                   2019-07-11
                   LISN                             Rohde & Schwarz                                ENV216                     SEM007-01                    2018-09-25                   2019-09-24
                   LISN                               ETS-LINDGREN                                  3816/2                    SEM007-02                    2018-04-02                   2019-04-01
      EMI Test Receiver                             Rohde & Schwarz                                   ESCI                    SEM004-02                    2018-04-02                   2019-04-01


Radiated Emissions (30MHz-1GHz)
            Equipment                                   Manufacturer                             Model No                   Inventory No                      Cal Date                Cal Due Date
    10m Semi-Anechoic
                                                              SAEMC                             FSAC1018                      SEM001-03                    2018-03-31                   2021-03-30
        Chamber
                                                                                             e3 V8.2014-6-
 Measurement Software                                          AUDIX                                                                  N/A                          N/A                         N/A
                                                                                                  27
          Coaxial Cable                                          SGS                                   N/A                    SEM029-01                    2018-07-12                   2019-07-11
      EMI Test Receiver
                                                    Rohde & Schwarz                                   ESR                     SEM004-03                    2018-04-02                   2019-04-01
        (9kHz-7GHz)
    Trilog-Broadband
                                                         Schwarzbeck                            VULB9168                      SEM003-18                    2016-06-29                   2019-06-28
 Antenna(30MHz-1GHz)
                                                   Sonoma Instrument
           Pre-amplifier                                                                             310N                     SEM005-04                    2018-04-13                   2019-04-12
                                                         Co


Radiated Emissions (above 1GHz)
            Equipment                                   Manufacturer                             Model No                   Inventory No                      Cal Date                Cal Due Date
     3m Semi-Anechoic
                                                               AUDIX                                   N/A                    SEM001-02                    2018-03-13                   2021-03-12
         Chamber
                                                                                             e3 V8.2014-6-
 Measurement Software                                          AUDIX                                                                  N/A                          N/A                         N/A
                                                                                                  27
          Coaxial Cable                                          SGS                                   N/A                    SEM026-01                    2018-07-12                   2019-07-11
                                                  AgilentTechnologies
EXA Spectrum Analyzer                                                                              N9010A                     SEM004-09                    2018-04-13                   2019-04-12
                                                          Inc
Horn Antenna(1-18GHz)                               Rohde & Schwarz                                 HF907                     SEM003-07                    2018-04-13                   2021-04-12
                                                       Compliance
       Pre-Amplifier(0.1-
                                                   Directions Systems                            PAP-0126                     SEM004-11                    2018-09-27                   2019-09-26
           26.5GHz)
                                                           Inc.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       8 of 24


General used equipment
             Equipment                                  Manufacturer                             Model No                   Inventory No                      Cal Date                Cal Due Date
                                                         Shanghai
  Humidity/ Temperature
                                                       Meteorological                               ZJ1-2B                    SEM002-03                    2018-09-27                   2019-09-26
        Indicator
                                                      Industry Factory
                                                         Shanghai
  Humidity/ Temperature
                                                       Meteorological                               ZJ1-2B                    SEM002-04                    2018-09-27                   2019-09-26
        Indicator
                                                      Industry Factory
  Humidity/ Temperature
                                                                Mingle                                 N/A                    SEM002-08                    2018-09-27                   2019-09-26
        Indicator
                                                        Changchun
              Barometer                                Meteorological                                DYM3                     SEM002-01                    2018-04-08                   2019-04-07
                                                      Industry Factory




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       9 of 24



6          Emission Test Results
6.1 Conducted Emissions at Mains Terminals (150kHz-30MHz)
           Test Requirement:                                47 CFR Part 15, Subpart B
           Test Method:                                     ANSI C63.4:2014
           Frequency Range:                                 150kHz to 30MHz
           Limit:
           0.15M-0.5MHz                                     66dB(µV)-56dB(µV) quasi-peak, 56dB(µV)-46dB(µV) average
           0.5M-5MHz                                        56dB(µV) quasi-peak, 46dB(µV) average
           5M-30MHz                                         60dB(µV) quasi-peak, 50dB(µV) average
           Detector:                                        Peak for pre-scan (9kHz resolution bandwidth) 0.15M to 30MHz

6.1.1 E.U.T. Operation
      Operating Environment:
      Temperature:      20.4 °C          Humidity: 51.6 % RH        Atmospheric Pressure: 1010 mbar
      Pretest these     j: Transfer data between the EUT and the PC
      modes to find     k: Telecom Idle+BT+FM+NFC+WLAN+GPS Rx+playing MP4+earphone+adapter
      the worst case:
                        l: Telecom Idle+BT+FM+NFC+WLAN+GPS Rx+camera(Front)+earphone+adapter
                        m: Telecom Idle+BT+FM+NFC+WLAN+GPS
                        Rx+camera(Back)+earphone+adapter
                        n: GSM 850+BT+FM+NFC+WLAN+GPS Rx+earphone+adapter
                        p: WCDMA Band II+BT+FM+NFC+WLAN+GPS Rx+earphone+adapter
                        r: LTE band 2+BT+FM+NFC+WLAN+GPS Rx+earphone+adapter
      The worst case    j: Transfer data between the EUT and the PC
      for final test:   k: Telecom Idle+BT+FM+NFC+WLAN+GPS Rx+playing MP4+earphone+adapter
6.1.2 Test Setup Diagram




6.1.3 Measurement Data
      An initial pre-scan was performed with peak detector.Quasi-Peak or Average measurement were
      performed at the frequencies with maximized peak emission were detected.



This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       10 of 24


Mode:j; Line:Live Line




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       11 of 24


Mode:j; Line:Neutral Line




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       12 of 24


Mode:k; Line:Live Line




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       13 of 24


Mode:k; Line:Neutral Line




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       14 of 24


6.2 Radiated Emissions (30MHz-1GHz)
           Test Requirement:                                47 CFR Part 15, Subpart B
           Test Method:                                     ANSI C63.4:2014
           Frequency Range:                                 30MHz to 1GHz
           Measurement Distance:                            10m
           Limit of 3m:
           30MHz -88MHz                                     40(dBµV/m) quasi-peak
           88MHz-216MHz                                     43.5(dBµV/m) quasi-peak
           216MHz-960MHz                                    46(dBµV/m) quasi-peak
           960MHz-1000MHz                                   54(dBµV/m) quasi-peak
           Detector:                                        Peak for pre-scan (120kHz resolution bandwidth) 30M to1000MHz




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       15 of 24



6.2.1 E.U.T. Operation
      Operating Environment:
      Temperature:      25 °C            Humidity: 51 % RH          Atmospheric Pressure: 1010 mbar
      Pretest these     j: Transfer data between the EUT and the PC
      modes to find     k: Telecom Idle+BT+FM+NFC+WLAN+GPS Rx+playing MP4+earphone+adapter
      the worst case:
                        l: Telecom Idle+BT+FM+NFC+WLAN+GPS Rx+camera(Front)+earphone+adapter
                        m: Telecom Idle+BT+FM+NFC+WLAN+GPS
                        Rx+camera(Back)+earphone+adapter
                        n: GSM 850+BT+FM+NFC+WLAN+GPS Rx+earphone+adapter
                        o: GSM 1900+BT+FM+NFC+WLAN+GPS Rx+earphone+adapter
                        p: WCDMA Band II+BT+FM+NFC+WLAN+GPS Rx+earphone+adapter
                        q: WCDMA Band V+BT+FM+NFC+WLAN+GPS Rx+earphone+adapter
                        r: LTE band 2+BT+FM+NFC+WLAN+GPS Rx+earphone+adapter
                        s: LTE band 5+BT+FM+NFC+WLAN+GPS Rx+earphone+adapter
                        t: LTE band 7+BT+FM+NFC+WLAN+GPS Rx+earphone+adapter
      The worst case    j: Transfer data between the EUT and the PC
      for final test:   l: Telecom Idle+BT+FM+NFC+WLAN+GPS Rx+camera(Front)+earphone+adapter
6.2.2 Test Setup Diagram




6.2.3 Measurement Data
      An initial pre-scan was performed in the chamber using the spectrum analyser in peak detection
      mode. Quasi-peak measurements were conducted based on the peak sweep graph. The EUT was
      measured by BiConiLog antenna with 2 orthogonal polarities.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       16 of 24


Mode:j;



                                                                                    Radiated Emissions


   Polarization                Frequency                 Cable_ Antenna                             Pre-                Reading                  Net                    Limit                Margin
                                 (MHz)                  Loss (dB) Factor                            Amp                 at 10m                  at 3m                   at 3m                 (dB)
                                                                   (dB)                             Gain                (dBµV)                (dBµV/m)                (dBµV/m)
                                                                                                    (dB)
    Horizontal                   51.481                     6.93               12.66               32.45                  30.33                   27.93                   40.00              -12.07
    Horizontal                   93.768                     7.19               8.96                32.47                  34.76                   28.90                   43.50              -14.60
    Horizontal                  135.982                     7.38               12.47               32.44                  32.38                   30.25                   43.50              -13.25
    Horizontal                  216.024                     7.69               9.91                32.39                  34.07                   29.74                   46.00              -16.26
    Horizontal                  399.030                     8.31               14.84               32.34                  32.25                   33.52                   46.00              -12.48
    Horizontal                  699.305                     9.08               20.10               32.31                  26.73                   34.06                   46.00              -11.94
     Vertical                    58.819                     7.01               12.09               32.45                  35.08                   32.19                   40.00               -7.81
     Vertical                    86.200                     7.16               8.64                32.47                  34.82                   28.61                   40.00              -11.39
     Vertical                   128.113                     7.34               11.93               32.44                  32.56                   29.85                   43.50              -13.65
     Vertical                   216.024                     7.69               9.91                32.39                  32.22                   27.89                   46.00              -18.11
     Vertical                   298.268                     8.00               12.62               32.36                  32.88                   31.60                   46.00              -14.40
     Vertical                   399.030                     8.31               14.84               32.34                  29.90                   31.17                   46.00              -14.83


NOTES:
    1.           Quasi-Peak detector is used except for others stated.
    2.           All measurements were made at 10 meters.
    3.           Negative value in the margin column shows emission below limit.
    4.           Final Test Leve l (Net at 3m) =Receiver Reading + Antenna Factor + Cable Factor + F1 –
                  Preamplifier Factor
            The calculation of field strength between 10m and 3m test distance.




            F1: is the factor of distance 10m to 3m = 20log(10/3) =10.458




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       17 of 24


Mode:l;



                                                                                    Radiated Emissions


   Polarization                Frequency                 Cable_ Antenna                             Pre-                Reading                  Net                    Limit                Margin
                                 (MHz)                  Loss (dB) Factor                            Amp                 at 10m                  at 3m                   at 3m                 (dB)
                                                                   (dB)                             Gain                (dBµV)                (dBµV/m)                (dBµV/m)
                                                                                                    (dB)
    Horizontal                   40.702                     6.83               13.26               32.46                  25.94                   24.03                   40.00              -15.97
    Horizontal                  154.821                     7.46               13.40               32.43                  26.79                   25.68                   43.50              -17.82
    Horizontal                  283.979                     7.96               12.26               32.37                  26.27                   24.58                   46.00              -21.42
    Horizontal                  413.271                     8.35               15.23               32.34                  26.15                   27.85                   46.00              -18.15
    Horizontal                  605.659                     8.89               18.83               32.37                  26.28                   32.09                   46.00              -13.91
    Horizontal                  766.057                     9.22               20.96               32.21                  27.41                   35.84                   46.00              -10.16
     Vertical                    43.812                     6.86               13.00               32.46                  27.21                   25.07                   40.00              -14.93
     Vertical                    72.084                     6.95               9.73                32.46                  30.02                   24.70                   40.00              -15.30
     Vertical                   166.068                     7.50               12.79               32.42                  26.78                   25.11                   43.50              -18.39
     Vertical                   309.998                     8.04               12.95               32.36                  27.42                   26.51                   46.00              -19.49
     Vertical                   638.369                     8.96               19.39               32.35                  27.61                   34.07                   46.00              -11.93
     Vertical                   912.862                     9.50               22.40               31.48                  25.97                   36.85                   46.00               -9.15


NOTES:
    1.           Quasi-Peak detector is used except for others stated.
    2.           All measurements were made at 10 meters.
    3.           Negative value in the margin column shows emission below limit.
    4.           Final Test Leve l (Net at 3m) =Receiver Reading + Antenna Factor + Cable Factor + F1 –
                  Preamplifier Factor
            The calculation of field strength between 10m and 3m test distance.




            F1: is the factor of distance 10m to 3m = 20log(10/3) =10.458




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       18 of 24


6.3 Radiated Emissions (above 1GHz)
           Test Requirement:                                47 CFR Part 15, Subpart B
           Test Method:                                     ANSI C63.4:2014
           Frequency Range:                                 Above 1GHz
           Measurement Distance:                            3m
           Limit:
           Above 1GHz                                       74(dBµV/m) peak, 54(dBµV/m) average
           Detector:                                        Peak for pre-scan (1000kHz resolution bandwidth) 1000M to18000MHz




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       19 of 24



6.3.1 E.U.T. Operation
      Operating Environment:
      Temperature:      21.9 °C          Humidity: 60.3 % RH        Atmospheric Pressure: 1010 mbar
      Pretest these     j: Transfer data between the EUT and the PC
      modes to find     k: Telecom Idle+BT+FM+NFC+WLAN+GPS Rx+playing MP4+earphone+adapter
      the worst case:
                        l: Telecom Idle+BT+FM+NFC+WLAN+GPS Rx+camera(Front)+earphone+adapter
                        m: Telecom Idle+BT+FM+NFC+WLAN+GPS
                        Rx+camera(Back)+earphone+adapter
                        n: GSM 850+BT+FM+NFC+WLAN+GPS Rx+earphone+adapter
                        o: GSM 1900+BT+FM+NFC+WLAN+GPS Rx+earphone+adapter
                        p: WCDMA Band II+BT+FM+NFC+WLAN+GPS Rx+earphone+adapter
                        q: WCDMA Band V+BT+FM+NFC+WLAN+GPS Rx+earphone+adapter
                        r: LTE band 2+BT+FM+NFC+WLAN+GPS Rx+earphone+adapter
                        s: LTE band 5+BT+FM+NFC+WLAN+GPS Rx+earphone+adapter
                        t: LTE band 7+BT+FM+NFC+WLAN+GPS Rx+earphone+adapter
      The worst case    j: Transfer data between the EUT and the PC
      for final test:   k: Telecom Idle+BT+FM+NFC+WLAN+GPS Rx+playing MP4+earphone+adapter
6.3.2 Test Setup Diagram




6.3.3 Measurement Data
      An initial pre-scan was performed in the chamber using the spectrum analyser in peak detection
      mode. Average measurements were conducted based on the peak sweep graph. The EUT was
      measured by Horn antenna with 2 orthogonal polarities.
      Scan from 1GHz to 29.125GHz, the disturbance above 6GHz was very low. The points marked on
      above plots are the highest emissions could be found when testing, so only above points had been
      displayed.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       20 of 24


Mode:j; Polarization:Horizontal




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       21 of 24


Mode:j; Polarization:Vertical




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       22 of 24


Mode:k; Polarization:Horizontal




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       23 of 24


Mode:k; Polarization:Vertical




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: ZR/2018/9002706
                                                                                                                                 Page:       24 of 24


7         Photographs
7.1 Test Setup
            Please refer to setup photos.

7.2 EUT Constructional Details (EUT Photos)
           Please refer to external and internal photos for details.

                                                                                     - End of the Report -




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.



Document Created: 2018-12-24 03:31:14
Document Modified: 2018-12-24 03:31:14

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC