Calibration Laboratory of                                                                                   S      Schweizerischer Kalibrierdienst
Schmid & Partner                                                                                                   Service suisse d'etalonnage
 Engineering AG
                                                                                                            C
                                                                                                                   Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                s      Swiss Calibration Service


Accredited by the Swiss Accreditation Service (SAS)                                                          Accreditation No.:     SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client      Sporton                                                                             Certificate No:    CD835V3-1045_Sep18

CALIBRATION CERTIFICATE
 Object                                CD835V3 - SN: 1045


 Calibration procedure(s)              QA CAL-20.v6
                                       Calibration procedure for dipoles in air



 Calibration date:                     September 19, 2018

 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (SI).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 ± 3)°C and humidity < 70%.

 Calibration Equipment used (M&TE critical for calibration)
 Primary Standards                      ID#                        Cal Date (Certificate No.)                           Scheduled Calibration
 Power meter NAP                        SN: 104778                04-Apr-18 (No. 217-02672/02673)                       Apr-19
 Power sensor NRP-Z91                   SN: 103244                04-Apr-18 (No. 217-02672)                             Apr-19
 Power sensor NRP-Z91                   SN: 103245                04-Apr-18 (No. 217-02673)                             Apr-19
 Reference 20 dB Attenuator             SN: 5058 (20k)            04-Apr-18 (No. 217-02682)                             Apr-19
 Type-N mismatch combination            SN: 5047 .2 / 06327       04-Apr-18 (No. 217-02683)                             Apr-19
 Probe EF3DV3                           SN: 4013                  05-Mar-18 (No. EF3-4013_Mar18)                        Mar-19
 DAE4                                   SN: 781                   17-Jan-18 (No. DAE4-781 _Jan18)                       Jan-19



 Secondary Standards                    ID#                       Check Date (in house)                                 Scheduled Check
 Power meter Agilent 44196              SN: GB42420191            09-0ct-09 (in house check Oct-17)                     In house check: Oct-20
 Power sensor HP E4412A                 SN: US38485102            05-Jan-10 (in house check Oct-17)                     In house check: Oct-20
 Power sensor HP 8482A                  SN: US37295597            09-0ct-09 (in house check Oct-17)                     In house check: Oct-20
 RF generator R&S SMT-06                SN: 832283/01 1           27-Aug-12 (in house check Oct-17)                     In house check: Oct-20
 Network Analyzer Agilent E8358A        SN: US41080477            31-Mar-14 (in house check Oct-17)                     In house check: Oct- 18

                                        Name                                   Function                                 Signature
 Calibrated by:                         Leif Klysner                           Laboratory Technician



 Approved by:                           Katja Pokovic                          Technical Manager




                                                                                                                       Issued: September 24, 2018
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




Certificate No: CD835V3-1045_Sep 18                         Page 1 of 5


Calibration Laboratory of
Schmid & Partner
                                                                                           s   Schweizerischer Kalibrierdienst
                                                                                               Service suisse d'etalonnage
                                                                                           C
 Engineering AG                                                                                Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                               s   Swiss Calibration Service

Accredited by the Swiss Accreditation Service (SAS)                                        Accreditation No.:   SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates


References
[1]       ANSI-C63.19-2011
          American National Standard, Methods of Measurement of Compatibility between Wireless Communications
          Devices and Hearing Aids.
Methods Applied and Interpretation of Parameters:
      •   Coordinate System: y-axis is in the direction of the dipole arms. z-axis is from the basis of the antenna
          (mounted on the table} towards its feed point between the two dipole arms. x-axis is normal to the other axes.
          In coincidence with the standards [1 ], the measurement planes (probe sensor center) are selected to be at a
          distance of 15 mm above the top metal edge of the dipole arms.
      •   Measurement Conditions: Further details are available from the hardcopies at the end of the certificate. All
          figures stated in the certificate are valid at the frequency indicated. The forward power to the dipole connector
          is set with a calibrated power meter connected and monitored with an auxiliary power meter connected to a
          directional coupler. While the dipole under test is connected, the forward power is adjusted to the same level.
      •   Antenna Positioning: The dipole is mounted on a HAC Test Arch phantom using the matching dipole
          positioner with the arms horizontal and the feeding cable coming from the floor. The measurements are
          performed in a shielded room with absorbers around the setup to reduce the reflections.
          It is verified before the mounting of the dipole under the Test Arch phantom , that its arms are perfectly in a
          line. It is installed on the HAC dipole positioner with its arms parallel below the dielectric reference wire and
          able to move elastically in vertical direction without changing its relative position to the top center of the Test
          Arch phantom. The vertical distance to the probe is adjusted after dipole mounting with a DASY5 Surface
          Check job. Before the measurement, the distance between phantom surface and probe tip is verified. The
          proper measurement distance is selected by choosing the matching section of the HAC Test Arch phantom
          with the proper device reference point (upper surface of the dipole) and the matching grid reference point (tip
          of the probe) considering the probe sensor offset. The vertical distance to the probe is essential for the
          accuracy.
      •   Feed Point Impedance and Return Loss: These parameters are measured using a HP 8753E Vector Network
          Analyzer. The impedance is specified at the SMA connector of the dipole. The influence of reflections was
          eliminating by applying the averaging function while moving the dipole in the air, at least 70cm away from any
          obstacles.
      •   E-tield distribution: E field is measured in the x-y-plane with an isotropic ER3D-field probe with 100 mW
          forward power to the antenna feed point. In accordance with [1 ], the scan area is 20mm wide, its length
          exceeds the dipole arm length (180 or 90mm). The sensor center is 15 mm (in z) above the metal top of the
          dipole arms. Two 30 maxima are available near the end of the dipole arms. Assuming the dipole arms are
          perfectly in one line, the average of these two maxima (in subgrid 2 and subgrid 8) is determined to
          compensate for any non-parallelity to the measurement plane as well as the sensor displacement. The E-field
          value stated as calibration value represents the maximum of the interpolated 30-E-field, in the plane above
          the dipole surface.




 The reported uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the
 coverage factor k=2, which for a normal distribution corresponds to a coverage probability of approximately 95%.




Certificate No: CD835V3-1045_Sep18                     Page 2 of 5


Measurement Conditions
    DASY svstem confiquration, as far as not aiven on paae 1.
      DASY Version                                               DASY5                        V52.10.1
      Phantom                                                HAC Test Arch
      Distance Dipole Top - Probe Center                         15 mm
      Scan resolution                                        dx, dy= 5 mm
      Frequency                                          835 MHz± 1 MHz
      Input power drift                                         < 0.05 dB



Maximum Field values at 835 MHz

      E-field 15 mm above dipole surface                            condition          Interpolated maximum
      Maximum measured above high end                         100 mW input power      109.3 Vim= 40.77 dBVlm
      Maximum measured above low end                          100 mW input power      108.2 Vim= 40.68 dBVlm
     Averaged maximum above arm                               100 mW input power      108.8 Vim± 12.8 % (k=2)



Appendix (Additional assessments outside the scope of SCS 0108)

Antenna Parameters

      Frequency                                                   Return Loss                Impedance
      800 MHz                                                        16.0 dB               40.8 Q - 11.3 jQ
      835 MHz                                                        32.3 dB               49.4 Q + 2.3 jQ
      880 MHz                                                        18.1 dB               57.9 Q - 11.0 jQ
      900 MHz                                                        18.2 dB               48.3 Q -12.1 jQ
      945 MHz                                                        20.5 dB               49.1 Q + 9.3 jQ



3.2 Antenna Design and Handling

The calibration dipole has a symmetric geometry with a built-in two stub matching network, which leads to the
enhanced bandwidth.
The dipole is built of standard semi rigid coaxial cable. The internal matching line is open ended. The antenna is
therefore open for DC signals.
Do not apply force to dipole arms, as they are liable to bend. The soldered connections near the feedpoint may be
damaged. After excessive mechanical stress or overheating, check the impedance characteristics to ensure that the
internal matching network is not affected.

After long term use with 40W radiated power, only a slight warming of the dipole near the feedpoint can be measured.




Certificate No: CD835V3-1045_Sep18             Page 3 of 5


Impedance Measurement Plot




      File         View   Channel    Sweep     Calibration   Trace       Scale   Marker—      System        Window     Help

        10.00             811                                                                                                         dpooo0 M            958 d8
        s.00                                                                                                                   ;     5—000000—MH        30.31548
                                                                                                                                   200 (PODGO MHz      —18.10448
        0.00                                        ==—i———                                                            T           sotopooot hhie      "To T990F)
        s on                                                         Bs                                                    s       _____§a5 00000 We     i 52208
        F10.00                                                                                                     (
        H15.00                                                                                                     “

        L20.00                                                                      BA                _Lesx34—[/
                                                                                         \I       /          6
        25.00                                                                                                +
             f                                                                                T
                                                                                              [
        F20.00
        F35.00
        H0.00        Ch 1 Aug= 20
            Ch1: Start 395.000 MHe        ——                                                                                                     Stop 1.33500 GHz


                                                                                                                           1       500 000000 MHz        40753 0
                                                                                                                                          17 £80 pF
                                                                                                                           2       #35 000000 MHz
                                                                                                                                         442 05 pH
                                                                                                                                   @80 000000 MHz
                                                                                                                                          16 511 pF
                                                                                                                           4       400 000000 MHz
                                                                                                                                          14 6R4pF
                                                                                                                           5       245 000000 MHz
                                                                                                                                         15710 nH




                          Ch1Aug= 20
                 Ch1: Start 395.000 MHa   ——                                                                                                     Stop 1.33500 GHz

        Status            CH 1:     ETI                      C* 1—Port                            Avg=20 Delay                                         LCL




Certificate No: CD835V3—1045_Sep18                               Page 4 of 5


DASY5 E-field Result

                                                                                              Date: 19.09.20 18

Test Laboratory: SPEAG Lab2

DUT: HAC-Dipole 835 MHz; Type: CD835V3; Serial: CD835V3 - SN: 1045

Communication System: UID O - CW ; Frequency: 835 MHz
Medium parameters used: cr = 0 Sim, e, = I ; p = 0 kg/m3
Phantom section: RF Section
Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19-20 1 l )

DASY52 Configuration:

    •   Probe : EF3DV3 - SN4013; ConvF(l, 1, 1) @ 835 MHz; Calibrated : 05.03.2018
    •   Sensor-Surface: (Fix Surface)
    •   Electronics: DAE4 Sn781; Calibrated: 17.01.2018
    •   Phantom : HAC Test Arch with AMCC; Type: SD HAC POl BA; Serial : 1070
    •   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)



Dipole E-Field measurement@ 835MHz/E-Scan - 835MHz d=15mm/Hearing Aid Compatibility Test (41x361xl):
Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value= 132.0 V/m; Power Drift= 0.00 dB
Applied MIF = 0.00 dB
RF audio interference level= 40.77 dBV/m
Emission category: M3
                                         MIF scaled E-field

                                          Grid 1 M3      Grid 2 M3    Grid 3 M3
                                          40.25 dBV/m 40.68 dBV/m 40.63 dBV/m

                                          Grid 4 M4      Grid 5 M4    Grid 6 M4
                                          35.68 dBV/m 35.97 dBV/m 35.93 dBV/m

                                          Grid 7 M3      Grid 8 M3    Grid 9 M3
                                          40.47 dBV/m 40.77 dBV/m 40.67 dBV/m



             dB
             D


              -1.92


              -3.84


              -5.77


              -7.69


              -9.61
                        0 dB = 109.3 V/m = 40.77 dBV/m




Certificate No: CD835V3-1045_Sep18              Page 5 of 5


Calibration Laboratory of
Schmid & Partner
                                                                                                            s
                                                                                                            C
                                                                                                                   Schweizerischer Kalibrierdienst
                                                                                                                   Service suisse d'etalonnage
 Engineering AG                                                                                                    Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                s      Swiss Calibration Service


Accredited by the Swiss Accreditation Service (SAS)                                                          Accreditation No.:     SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client      Sporton                                                                             Certificate No:    CD1880V3-1038_Sep18

!CALIBRATION CERTIFICATE
 Object                                CD1880V3 - SN: 1038


 Calibration procedure(s)              QA CAL-20.v6
                                       Calibration procedure for dipoles in air




 Calibration date:                     September 19, 2018

 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (SI).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 ± 3)°C and humidity < 70%.

 Calibration Equipment used (M&TE critical for calibration)
 Primary Standards                      ID#                       Cal Date (Certificate No.)                            Scheduled Calibration
 Power meter NAP                        SN: 104778                04-Apr-18 (No. 217-02672/02673)                       Apr-19
 Power sensor NRP-291                   SN: 103244                04-Apr-18 (No. 217-02672)                             Apr-1 9
 Power sensor NRP-291                   SN: 103245                04-Apr-1 8 (No. 217-02673)                            Apr-19
 Reference 20 dB Attenuator             SN: 5058 (20k)            04-Apr-18 (No. 217-02682)                             Apr-1 9
 Type-N mismatch combination            SN: 5047.2 / 06327        04-Apr-18 (No. 217-02683)                             Apr-19
 Probe EF3DV3                           SN: 4013                  05-Mar-18 (No. EF3-4013_Mar18)                        Mar-19
 DAE4                                   SN: 781                    17-Jan-18 (No. DAE4-781_Jan18)                      Jan-19



 Secondary Standards                    ID#                       Check Date (in house)                                 Scheduled Check
 Power meter Agilent 4419B              SN: GB42420191            09-0ct-09 (in house check Oct-17)                     In house check: Oct-20
 Power sensor HP E4412A                 SN: US38485102            05-Jan-10 (in house check Oct-17)                     In house check: Oct-20
 Power sensor HP 8482A                  SN: US37295597            09-0ct-09 (in house check Oct-17)                     In house check: Oct-20
 RF generator R&S SMT-06                SN: 832283/011            27-Aug-12 (in house check Oct-17)                     In house check: Oct-20
 Network Analyzer HP 8358A              SN: US41080477            31-Mar-14 (in house check Oct-17)                     In house check: Oct-18

                                        Name                                   Function                                 Signature
 Calibrated by:                         Leif Klysner                           Laboratory Technician



 Approved by:                           Katja Pokovic                          Technical Manager




                                                                                                                       Issued: September 24, 2018
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




Certificate No: CD1880V3-1038_Sep18                         Page 1 of 7


Calibration Laboratory of
Schmid & Partner
                                                                                           s   Schweizerischer Kalibrierdienst
                                                                                               Service suisse d'etalonnage
                                                                                           C
 Engineering AG                                                                                Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                               s   Swiss Calibration Service

Accredited by the Swiss Accreditation Service (SAS)                                        Accreditation No.:   SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates


References
[1]       ANSI-C63.19-2011
          American National Standard, Methods of Measurement of Compatibility between Wireless Communications
          Devices and Hearing Aids.
Methods Applied and Interpretation of Parameters:
      •   Coordinate System: y-axis is in the direction of the dipole arms. z-axis is from the basis of the antenna
          (mounted on the table) towards its teed point between the two dipole arms. x-axis is normal to the other axes.
          In coincidence with the standards [1], the measurement planes (probe sensor center) are selected to be at a
          distance of 15 mm above the top metal edge of the dipole arms.
      •   Measurement Conditions: Further details are available from the hardcopies at the end of the certificate. All
          figures stated in the certificate are valid at the frequency indicated. The forward power to the dipole connector
          is set with a calibrated power meter connected and monitored with an auxiliary power meter connected to a
          directional coupler. While the dipole under test is connected, the forward power is adjusted to the same level.
      •   Antenna Positioning: The dipole is mounted on a HAC Test Arch phantom using the matching dipole
          positioner with the arms horizontal and the feeding cable coming from the floor. The measurements are
          performed in a shielded room with absorbers around the setup to reduce the reflections.
          It is verified before the mounting of the dipole under the Test Arch phantom, that its arms are perfectly in a
          line. It is installed on the HAC dipole positioner with its arms parallel below the dielectric reference wire and
          able to move elastically in vertical direction without changing its relative position to the top center of the Test
          Arch phantom. The vertical distance to the probe is adjusted after dipole mounting with a DASY5 Surface
          Check job. Before the measurement, the distance between phantom surface and probe tip is verified. The
          proper measurement distance is selected by choosing the matching section of the HAC Test Arch phantom
          with the proper device reference point (upper surface of the dipole) and the matching grid reference point (tip
          of the probe) considering the probe sensor offset. The vertical distance to the probe is essential tor the
          accuracy.
      •   Feed Point Impedance and Return Loss: These parameters are measured using a HP 8753E Vector Network
          Analyzer. The impedance is specified at the SMA connector of the dipole. The influence of reflections was
          eliminating by applying the averaging function while moving the dipole in the air, at least 70cm away from any
          obstacles.
      •   E-field distribution: E field is measured in the x-y-plane with an isotropic ER3D-field probe with 100 mW
          forward power to the antenna feed point. In accordance with [1 J, the scan area is 20mm wide, its length
          exceeds the dipole arm length (180 or 90mm). The sensor center is 15 mm (in z) above the metal top of the
          dipole arms. Two 3D maxima are available near the end of the dipole arms. Assuming the dipole arms are
          perfectly in one line, the average of these two maxima (in subgrid 2 and subgrid 8) is determined to
          compensate for any non-parallelity to the measurement plane as well as the sensor displacement. The E-field
          value stated as calibration value represents the maximum of the interpolated 3D-E-field, in the plane above
          the dipole surface.




 The reported uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the
 coverage factor k=2, which for a normal distribution corresponds to a coverage probability of approximately 95%.




Certificate No: CD1880V3-1038_Sep18                    Page 2 of 7


Measurement Conditions
    DA SY svstem configuration, as far as not aiven on page 1.
      DASY Version                                               DASY5                    V52.10.1
      Phantom                                                HAC Test Arch
      Distance Dipole Top - Probe Center                         15 mm
     Scan resolution                                         dx, dy=5 mm
                                                         1730 MHz± 1 MHz
      Frequency
                                                         1880 MHz± 1 MHz
      Input power drift                                        < 0.05 dB



Maximum Field values at 1730 MHz

      E-field 15 mm above dipole surface                           condition       Interpolated maximum
      Maximum measured above high end                         100 mW input power   97.0 Vim= 39.74 dBV/m
      Maximum measured above low end                          100 mW input power   96.0 Vim= 39.65 dBV/m
     Averaged maximum above arm                               100 mW input power   96.5 Vim± 12.8 % (k=2)



Maximum Field values at 1880 MHz

      E-field 15 mm above dipole surface                           condition       Interpolated maximum
     Maximum measured above high end                          100 mW input power   90.3 Vim= 39.11 dBV/m
     Maximum measured above low end                           100 mW input power   88.8 Vim= 38.97 dBV/m
     Averaged maximum above arm                               100 mW input power   89.5 Vim ± 12.8 % (k=2)




Certificate No: CD1880V3-1038_Sep18            Page 3 of 7


Appendix (Additional assessments outside the scope of SCS 0108)

Antenna Parameters

Nominal Frequencies

      Frequency                                              Return Loss                     Impedance
      1730 MHz                                                  22.9 dB                    55.7 Q + 5.1 jQ
      1880 MHz                                                  21.2 dB                    59.3 Q + 2.0 jQ
      1900 MHz                                                  21.6 dB                     59.1 Q-1.1 jQ
      1950 MHz                                                  25.9 dB                     50.7 Q -5.0 jQ
      2000 MHz                                                  20.7 dB                    43.8 Q + 6.1 jQ

Additional Frequencies

      Frequency                                              Return Loss                     Impedance
      1730 MHz                                                  22.9 dB                    55.7 Q + 5.1 jQ



3.2 Antenna Design and Handling

The calibration dipole has a symmetric geometry with a built-in two stub matching network, which leads to the
enhanced bandwidth.
The dipole is built of standard semirigid coaxial cable. The internal matching line is open ended. The antenna is
therefore open for DC signals.
Do not apply force to dipole arms, as they are liable to bend. The soldered connections near the feedpoint may be
damaged. After excessive mechanical stress or overheating, check the impedance characteristics to ensure that the
internal matching network is not affected.

After long term use with 40W radiated power, only a slight warming of the dipole near the feedpoint can be measured.




Certificate No: CD1880V3-1038_Sep18          Page 4 of 7


Impedance Measurement Plot




     File     Yiew    Channel     Sweep     Calibration   Trace       Scale Marker   System    Window     Help
       7 0                                                                                                                   000                  6 dB
       200                                                                                                   a      1 4e0000.544             212g548
        5            _                                                                                           __—+        notorz          2T 3940E
       [**"                  ==E——                                                                          3       —rfamorone              se
       s on                            >                                                                  _4—s      > 100000 nite            on79048

       F13.00
       Fis.00                                                                                         /
                                                                                                 lj
       es oo                                                    +               e    B    LC
                                                                  1                       y
       Lze.00                                                         >                   z7
       F33.00
       F38.00
       F43.00                 = |20
             Ch1: Start 1.38000 GHa—   ——                                                                                            Stop 2.38000 GHz


                                                                                                             1          30                   55 664 0
                                                                                                                        465 71 pH
                                                                                                             2      1 ©80000 GHz                 66
                                                                                                                            b4pH             2 0038 0
                                                                                                                    1900000 GHz              59 058 0
                                                                                                                         79        539 pF     110531 0
                                                                                                             4      1 $50000 GHz             50 704 0
                                                                                                                         16 182 pF           3      a
                                                                                                             5     2000000 GHe
                                                                                                                         481.73pH            6,0536 0




                      Ch1 Aug= 20
             Chi: Start 1.38000 GHe    ——                                                                                           Stop 2.38000 GHz

       Status        CH 1:                                C* 1—Port                  Avg=20 Delay                                           LCL




Certificate No: CD1880V3—1038_Sep18                           Page 5 of 7


DASY5 E-field Result

                                                                                                        Date: 19.09.2018

Test Laboratory: SPEAG Lab2

DUT: HAC Dipole 1880 MHz; Type: CD1880V3; Serial: CD1880V3 - SN: 1038

Communication System: UID O - CW ; Frequency: 1880 MHz, Frequency: 1730 MHz
Medium parameters used: cr = 0 Sim,£,= I; p = 0 kg/m 3
Phantom section: RF Section
Measurement Standard: DASY5 (IEEE/IEC/ ANSI C63.I9-2011 )

DASY52 Configuration:

    •   Probe: EF3DV3 - SN4013; ConvF(l, 1, 1)@ 1880 MHz, ConvF{l, 1, 1)@ 1730 MHz; Calibrated: 05.03.2018
    •   Sensor-Surface: {Fix Surface)
    •   Electronics: DAE4 Sn781; Calibrated: 17.01.2018
    •   Phantom: HAC Test Arch with AMCC; Type: SD HAC POl BA; Serial: 1070
    •   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)



Dipole E-Field measurement@ 1880MHz/E-Scan - 1880MHz d=l5mm/Hearing Aid Compatibility Test (4lxl8lxl):
Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Re ference Point: 0, 0, -6.3 mm
Reference Value = 155.2 V/m; Power Drift= -0.03 dB
Applied MlF = 0.00 dB
RF audio interference level = 39. 11 dBV/m
Emission category: M2
                                        MIF scaled E-field

                                        Grid 1 M2      Grid 2 M2    Grid 3 M2
                                        38.75 dBV/m 39.11 dBV/m 39.05 dBV/m

                                        Grid 4 M2      Grid 5 M 2   Grid 6 M2
                                        36.11 dBV/m 36.24 dBV/m 36.17 dBV/m

                                        Grid 7 M2      Grid 8 M2    Grid 9 M2
                                        38.77 dBV/m 38.97 dBV/m 38.81dBV/m




Certificate No: CD1880V3-1038_ Sep18          Page 6 of 7


Dipole E-Field measurement@ 1730MHz/E-Scan - 1730MHz d=15mm/Hearing Aid Compatibility Test (41x181xl):
Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0 , -6.3 mm
Reference Value= 168.4 V/m; Power Drift= 0.00 dB
Applied MIF = 0.00 dB
RF audio interference level= 39.74 dBV/m
Emission category: M2
                                      MIF scaled E-field

                                       Grid 1 M2       Grid 2 M2   Grid 3 M2
                                       39.27 dBV/m 39.65 dBV/m 39.59dBV/m
                                       Grid 4 M2       Grid 5 M2   Grid 6 M2
                                       36.98dBV/m 37.17 dBV/m 37.12 dBV/m

                                       Grid 7 M2       Grid 8 M2   Grid 9 M2
                                       39.5 dBV/m      39.74 dBV/m 39.61 dBV/m




             dB
              0


             -0.97


             -1.95


             -2.92


             -3.90


             -4.87
                       0 dB= 90.29 V/m = 39.11 dBV/m




Certificate No: CD1880V3-1038_Sep18         Page 7 of 7


Calibration Laboratory of                                            \&ylxl                                          Schweizerischer Kalibrierdienst




                                                                                                            in 0 n
Schmid & Partner                                                      ue




                                                                io
                                                                                                                     Service suisse d‘étalonnage
   Engineering AG                                                                                                    Servizio svizzero di taratura




                                                              )
                                                              s«i
Zeughausstrasse 48, 8004 Zurich, Switzerland                         ty     NAW                                      Swiss Calibration Service
                                                                          To als®

Accredited by the Swiss Accreditation Service (SAS)                                                            Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client      Sporton                                                                               Certificate No: CD2600V3—1018_Aug18

|CALIBRATION CERTIFICATE                                                                                                                               |

 Object                               CD2600V3 — SN: 1018

 Calibration procedure(s)             QA CAL—20.v6
                                      Calibration procedure for dipoles in air



 Calibration date:                    August 22, 2018

 This calibration certifcate documents the traceabily to national standards, which realize the physical units of measurements (S1)
 The measurements and the uncertainties with confidence probabilty are given on the following pages and are part of the certiicate.

 All callorations have been conducted in the closed laboratory faciity: environmenttemperature (22 8)°C and humidity < 70%.

 Calibration Equipment used (M&TE critical for calibration)
 Primary Standards                      1D 4                      Cal Date (Certiicate No.)                               Scheduled Calioration
 Power meter NRP                        SN: 104778                04—Apr—18 (No. 217—02672/02673)                         Aor19
 Power sensor NRP—291                   SN: 103244                04—Apr—18 (No. 217—02672)                               Aor19
 Power sensor NRP—Z91                   SN: 103245                04—Ap—18 (No. 217—02673)                                Aor19
 Reference 20 dB Aftenuator             SN: 5058 (20k)            04—Apr—18 (No. 217—02602)                               Apr19
 Type—N mismatch combination            SN: 5047.2/ O6s27         04—Apr—18 (No. 217—02683)                               Aor—19
 Probe EF3DV3                           SN: 4013                  05—Mar—18 (No. EF3—4013_Mari8)                          Mar—19
 DAE                                    SN: 701                   17—an—18 (No. DAE4—761_Jan18)                           Jan—19




 Secondary Standards                    1D #                      Check Date (in house)                                   Scheduled Check
 Power meter Agilent 44198              ShN: aBaza20101           09—0ct—08 (in house check Oct—17)                       in house check: Oct—20
 Power sensor HP E4412A                 SN: US38485102            05—Jan—10 (in house check Oct—17)                       in house check: Oct—20
 Power sensor HP 8482A                  SN: US37205507            09—Oct—09 (in house check Oct—17)                       in house check: Oct—20
 RF generator R&S SMT—06                SN: 882289/011            27—Aug—12 (in house check Oct—17)                       In house check: Oct—20
 Network Analyzer HP 8358A              SN: US41080477            31—Mar—14 (in house chack Oct—17)                       In house check: Oct—18


                                        Name                                        Function                              Signature
 Callbrated by:                        Jeton Kastrati                               Laboratory Technician                          Jz


 Approved by:                          Ketja Pokovie                                Technical Manager                M"


                                                                                                                         Issued: August 23, 2018
 This calibration cartficate shall not be reproduced except in full without written approval of the laboratory.




Certificate No: CD2600V3—1018_Aug18                        Page 1 of 5


Calibration
      n     Laboratory of                                                                 G    Schweizerischer Kalibrierdienst
Schml_d & Partner                                                                         _    Service suisse d‘étalonnage
   Engineering AG                                                                         g     Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                   Swiss Calibration Service

Accredited by the Swiss Accreditation Service (SAS)                                        Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreementfor the recognition of calibration certificates


References
(]        ANSI—C63.19—2011
          American National Standard, Methods of Measurement of Compatibility between Wireless Communications
          Devices and Hearing Aids
Methods Applied and Interpretation of Parameters:
     *«   Coordinate System: y—axis is in the direction of the dipole arms. z—axis is from the basis of the antenna
          (mounted on the table) towards its feed point between the two dipole arms. x—axis is normal to the other axes.
          in coincidence with the standards [1], the measurement planes (probe sensor center) are selected to be at a
          distance of 15 mm above the top metal edge of the dipole arms.
     *    Measurement Conditions: Further details are available from the hardcopies at the end of the certificate. All
          figures stated in the certificate are valid at thefrequency indicated. The forward powerto the dipole connector
          is set with a calibrated power meter connected and monitored with an auxiliary power meter connected to a
          directional coupler. While the dipole under test is connected, the forward power is adjusted to the same level.
     *    Antenna Positioning: The dipole is mounted on a HAC Test Arch phantom using the matching dipole
          positioner with the arms horizontal and the feeding cable coming from the floor. The measurements are
          performed in a shielded room with absorbers around the setup to reduce the reflections.
          It is verified before the mounting of the dipole under the Test Arch phantom, that its arms are perfectly in a
          line. It is installed on the HAC dipole positioner with its arms parallel below the dielectric reference wire and
          able to move elastically in vertical direction without changingits relative position to the top center of the Test
          Arch phantom. The vertical distance to the probeis adjusted afterdipole mounting with a DASYS Surface
          Check job. Before the measurement, thedistance between phantom surface and probe tip is verified. The
          proper measurement distanceis selected by choosing the matching section of the HAC Test Arch phantom
          with the proper device reference point (upper surface of the dipole) and the matching grid reference point (tip
          of the probe) considering the probe sensor offset. The vertical distanceto the probe is essential for the
          accuracy.
     *    Feed Point Impedance and Return Loss:These parameters are measured using a HP 8753E Vector Network
          Analyzer. The impedance is specified at the SMA connector of the dipole. The influence of reflections was
          eliminating by applying the averaging function while moving the dipole in the air, at least 7Ocm away from any
          obstacles.
     e    E—field distribution: E field is measured in the x—y—plane with an isotropic ERSD—field probe with 100 mW
          forward power to the antenna feed point. In accordance with [1], the scan area is 20mm wide, its length
          exceeds the dipole arm length (180 or $0mm). The sensor center is 15 mm (in z) above the metal top of the
          dipole arms. Two 3D maxima are available near the end of the dipole arms. Assuming the dipole arms are
          perfectly in one line, the average of these two maxima (in subgrid 2 and subgrid 8) is determined to
          compensatefor any non—parallelity to the measurement plane as well as the sensordisplacement. The E—field
          value stated as calibration value represents the maximum of the interpolated 3D—E—field, in the plane above
          the dipole surface.




 The reported uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the
 coverage factor k=2, which for a normal distribution corresponds to a coverage probability of approximately 95%.




Certificate No: CD2600V3—1018_Aug18                    Page 2 of 5


Measurement Conditions
    DASY system configuration, as far as not given on page 1.
      DASY Version                                               DASYS                        V52.10.1
      Phantorn                                               HAC Test Arch
      Distance Dipole Top — Probe Center                         15 mm
      Scan resolution                                        dx, dy =5 mm
      Frequency                                          2600 MHz 1 MHz
      Input power drift                                         <0.05 dB


Maximum Field values at 2600 MHz

      E—field 15 mm above dipole surface                           condition           Interpolated maximum
      Maximum measured above high end                         100 mW input power       86.0 V/im=38.69 dBV/m
      Maximum measured above low end                          100 mW input power       85.7 Vim= 88.68 dBV/m
      Averaged maximum above arm                              100 mW input power       85.8 V/im £ 12.8 % (k=2)



Appendix (Additional assessments outside the scope of SCS 0108)

Antenna Parameters

      Frequency                                                   Return Loss                Impedance
      2450 MHz                                                      19.4 dB                 43.5 Q —7.6 ja
     2550 MHz                                                       28.9 dB                47.1 0+ 1.9 Q
      2600 MHz                                                      82.0 dB                49.8 0 + 2.2 |Q
     2650 MHz                                                       33.6 dB                52.0 0 + 0.8 jA
     2750 MHz                                                       22.1 dB                 50.9 Q —7.0 ja



3.2 Antenna Design and Handling

The calibration dipole has a symmetric geomeiry with a built—in two stub matching network, which leads to the
enhanced bandwidth.
The dipole is built of standard semnirigid coaxial cable. The intemal matching lineis open ended. The antennais
therefore open for DC signals.
Do not apply force to dipole arms, as they are liable to bend. The soldered connections near the feedpoint may be
damaged. After excessive mechanical stress or overheating, check the impedance characteristics to ensure that the
internal matching network is not affected.

After long term use with 40W radiated power, only a slight warming of the dipole near the feedpoint can be measured.




Certificate No: CD2600V8—1018_Aug18            Page 3 of 5


Impedance Measurement Plot




     file   VWw Channel        Sweep   Callbration       Trace:   Scale.       Marker   System   Window    Help

       20                                                                                                         s   a
                                                                                                             .        2 400000 oz
         an        |——                                                                                           z    Tenpert
       fass                                                                                                      s     cobtiion use |
        13.00                              —         —
        18.0
       les 00                                                              8                           %
       fes oo                                                                   x
         aun                                                                        4+—.
        as.00                                                                          a
       fasoe        ontawe= feo
           Chis Srare 2,10000 Sz    —                                                                                            Sop 310000 one
                                                                                                                 i    2 «50000 Gne       s 5o0 6
                                                                                                                           a Sai6 pF
                                                                                                                       > 550000 Gite
                                                                                                                           119.41 pH
                                                                                                                       : 600000 Giiz
                                                                                                                           137 83pH
                                                                                                                 a    2 s50000 Ghe
                                                                                                                           as 36aphH
                                                                                                                 s    2 750000 abe
                                                                                                                           7 2100 9F



                     thiaug= 20
            Cht: Start 2.10000 6e   —                                                                                            Stop 3.10000 GHz
       Status       CH 1:                            C*1Pot                             Ava=20 Delay                                   LCL




Certificate No: CD2600V3—1018_Aug18                         Page 4 of 5


DASY5 E—field Result

                                                                                               Date: 22.08.2018

Test Laboratory: SPEAG Lab2

DUT: HAC Dipole 2600 MHz; Type: CD2600V3; Serial: CD2600V3 — SN: 1018

Communication System: UID 0 — CW ; Frequency: 2600 MHz
Medium parameters used: 0 = 0 $/m, , = 1; p=0 kg/m‘
Phantom section: RF Section
Measurement Standard: DASY5 (IEEEAEC/ANSI C63.19—2011)

DASY52 Configuration:

     *    Probe: EF3DV3 — SN4013; ConvF(1, 1, 1) @ 2600 MHz; Calibrated: 05.03.2018
          Sensor—Surface: (Fix Surface)
          Electronics: DAE4 Sn781; Calibrated: 17.01.2018
  e e e




          Phantom: HAC Test Arch with AMCC; Type: SD HAC PO1 BA; Serial: 1070
          DASYS2 52.10.1{1476); SEMCAD X 14.6.11(7439)



Dipole E—Field measurement @ 2600MHz/E—Scan — 2600MHz d=15mn/Hearing Aid Compatibility Test (41x181x1):
Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Poi      . 0, 6.3 mm
Reference Value= 64.13 V/m; Power Drift = 0.00 dB
Applied MIF=0.00 dB
RF audio interference level = 38.69 dBV/m
Emission category: M2
                                            MIF scaled E—field
                                            Grid 1 M2      Grid 2 M2    Grid 3 M2
                                            38.4 dBV/m     138.69 dBV/m|38.62 dBV/m
                                            Grid 4 M2                   Grid 6 M2
                                            37.92 dBV/m                 38.04 dBV/m
                                            Grid 7 M2      |Grid 8 M2   |Grid 9 M2
                                            38.47 dBV/m|38.66 dBV/m |38.53 dBV/m




               1.42

               —2.84

               425

               5.67

               —7.09
                         0 dB = 86.00 V/m = 38.69 dBV/m




Certificate No: CD2600V3—1018_Aug18               Page 5 of 5


Calibration Laboratory of                                        \\élz/"//'//                             G. Schweizerischer Kalibrierdionst
Schmid & Partner                                                M                                         g    Service suisse d‘étalonnage
  Engineering AG                                                 ho e                                       Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                     24@53                                    S Swiss Calibration Service
                                                                     Hiiale


Accredited by the Swiss Accreditation Service (SAS)                                                      Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multiateral Agreement for the recognition of calibration cortificates
Client       Sporton                                                                          Certificato No: EF3—4047_Jan19


CALIBRATION CERTIFICATE
 Object                              EF3DV3— SN:4047


 Calibration procedure(s)            QA CAL—02.v8, QA CAL—25.07
                                     Calibration procedure for E—field probes optimized for close near field
                                     evaluations in air

 Caltbration date:                   January 30, 2019

This calibration certificate documents the traceabilty to national standards, which realize the physical units of measurements (S1).
The measurements and the uncertainties with confidence probabilty are given on the following pages and are part of the certificate.

Al calibrations have been conducted in the closed laboratory facilty: environment temperature (22 + 3)°C and humidity < 70%


 Calibration Equipment used (MTE critical for calibration)

 Primary Standards                  iD                                Gal Date (Certficate No.)                    Scheduled Calibration
 Power meter NRP                    SN: 104778                        04—Apr—18 (No. 217—02672/02673)              Apr—19
 Power sensor NRP—291               SN: 103244                        04—Apr—18 (No. 217—02672)                    Apr—19
 Power sensor NRP—291               SN: 103245                        04—Apr:18 (No. 217—02673)                    Apr—19
 Reference 20 dB Attenuator         SN: $5277 (205)                   4—Apr—18 (No. 217—02682)                     Aprtg
 DaE4                               SN. 789                           14—Jan—19 (No. DAE4—789_Jan19)               Jan—20
 Reference Probe ERIDV6             SN 2328                           09—Oct—18 (No. ER3—2328_Oct18)               Oct—19


 Secondary Standards                iD                                Check Date (in house)                        Scheduled Check
 Power meter E44198                 SN: GB41203B74                    06—Apr—16 (in house check Jun—18)            in house check: Jun—20
 Power sensor E4412A                SN: MY41498087                    06—Apr—16 (in house check Jun—18)            in house check; Jun—20
 Power sensor E4412A                SN: 000110210                     06—Apr:—16 in house check Jun—18)            in house check; Jun—20
 RF generator HP 8648G              SN: US3642U01700                  04—Aug—99 (in house check Jun—18)            in house check: Jun—20
 Network Analyzer E835BA            SN: US41080477                    31—Mar—14 (in house check Oct—18)            in house check: Oct—10

                                         Name                                 Function                              Signature
Callorated by:                        Manu Seite                              Laboratory Technician            /, rarer
                                                                                                                       eZF)
                                                                                                                                            v




                                                                                                               7        ie
Approved by:                          Katia Polovie                           Technical Manager          /g/4


                                                                                                                    Issued: January 31, 2019
This calibration certficate shall not be reproduced except in full without writen approval ofthe laboratory.


Certificate No: EF3—4047_Jan19                                      Page 1 of 9


Calibration Laboratory of                                                                 G   Schweizerischer Kalibrierdienst
Schmid & Partner                                                                          ;   Service suisse d‘étalonnage
   Engineering AG                                                                        «g   Servizio svizzero di taratura
Zoughausstrasse 43, 8004 Zurich, Switzerland                                                  Swiss Calibration Service


Accredited by the Swiss Accreditation Service (SAS)                                       Accreditation No.: SCS 0108
TheSwiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates
Glossary:
NORMx,y,z                    sensitivity in free space
DCP                          diode compression point
CF                           crest factor (1/duty_cycle) of the RF signal
A, B,C, D                    modulation dependent linearization parameters
En                           incident E—field orientation normal to probe axis
Ep                           incident E—field orientation parallel to probe axis
Polarization q               @p rotation around probe axis
Polarization 8               8 rotation around an axis that is in the plane normal to probe axis (at measurement center),
                             i.e., 8 = 0 is normal to probe axis
Connector Angle              information used in DASY system to align probe sensor X to the robot coordinate system

Calibration is Performed According to the Following Standards:
   a) IEEE Std 1309—2005, " IEEE Standard for calibration of electromagnetic field sensors and probes, excluding
       antennas, from 9 kHz to 40 GHz®, December2005
    b) CTIA Test Plan for Hearing Aid Compatibilty, Rev 3.1.1, May 2017

Methods Applied and Interpretation of Parameters:
         NORMxy,z: Assessed for E—field polarization 8 = 0 for XY sensors and 3 = 90 for Z sensor (f < 900 MHz in
         TEM—cell; £> 1800 MHz: R22 waveguide).
         NORM(Mx.y,z = NORMx,y,z * frequency_response (see Frequency Response Chart).
         DCPxy,z: DCP are numerical linearization parameters assessed based on the data of power sweep with CW
         signal (no uncertainty required). DCP does not depend on frequency nor media.
         PAR: PAR is the Peak to Average Ratio that is not calibrated but determined based on the signal
         characteristics
         Axsy.z Bxy,z; Coy,z; Dxy.2; VRxy,z: A, B, C, D are numerical linearization parameters assessed based on
         the data of power sweep for specific modulation signal. The parameters do not depend on frequency nor
         media. VR is the maximum calibration range expressed in RMS voltage across the diode.
         Spherical isotropy (3D deviation from isotropy): in a locally homogeneous field realized using an open
         waveguide setup.
         Sensor Offset: The sensor offset corresponds to the offset of virtual measurement center from the probetip
         (on probe axis). No tolerance required.
         Connector Angle: The angle is assessed using the information gained by determining the NORMsx (no
         uncertainty required).




Certificate No: EF3—4047_Jan19                                  Page 2 of 9


EF3DV3 — SN:4047                                                                                                             January 30, 2019


DASY/EASY — Parameters of Probe: EF3DV3 — SN:4047

Basic Calibration Parameters
                                                Sensor X                        Sensor Y                     Sensor Z              Unc (k=2)
  Norm (uV/(V/m)*)                                 0.84                            0.68                         1.20               *10.1 %
  DCP (mV)"                                        96.3                            98.2                         94.1

Calibration results for Frequency Response (30 MHz — 6 GHz)
 Frequency        Target E—Field           Measured              Deviation            Measured          Deviation                Unc (k=2)
 MHz                   V/im               E—field (En)           E—normal            E—field (Ep)       E—normal                    %
                                              Vim                  in %                  V/im              in %
 30                     77 .2                 77.3                  0.2%                  77.3             0.1%                   £5.1    %
 100                    77 .4                 78.0                  0.8%                  77.9             0.6%                   #5.1    %
 450                    77.1                  77.8                  1.0%                  77.9             1.1%                   #5.1    %
 600                    77.1                  77.4                  0.5%                  77.7             0.9%                   #5.1    %
 750                    77.2                  77.4                  0.2%                  77.A             0.2%                   #5.1    %

 1800                  140.4                 136.9                 —2.5%                  137.3           —2.2%                   #5.1    %
 2000                  133.0                 129.2                 —2.8%                  129.4           —2.1%                   £#5.1   %
 2200                  124.7                 121.4                 —2.1%                  122.7           —1.6%                   #5.1    %
 2500                  123.6                 120.6                 —2.4%                  121.8           —1.4%                   £5.1    %
 3000                  78.9                  75.4                  ~4.4%                  75.9            —3.7%                   £5.1    %

 3500                  256.3                 248.2                 —3.1%                  246.0           ~4.0%                  £5.1 %
 3700                  251.0                 240.6                 ~4.1%                  240.2           ~4.3%                  £5.1 %

 5200                   50.9                  50.9                 0.1%                   51.1            0.6%                   #5.1 %
 5500                   49.6                  49.0                 —1.3%                  48.7            —2.0%                  £5.1 %
 5800                   48.9                  49.2                 0.6%                   49.3            0.8%                   £#5.1 %




 The reported uncertainty of measurement is stated as the standard uncertainty of measurement
 multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
 probability of approximately 95%.

® Numerical linearization parameter: uncertainty not required.
  Uncertainty is determined using the max. deviation from linear response applying rectangular distribution and is expressed for the square of the
field value.




Certificate No: EF3—4047_Jan19                                      Page 3 of 9


EF3DV3 — SN:4047                                                                                                             January 30, 2019


DASY/EASY — Parameters of Probe: EF3DV3 — SN:4047
Calibration Results for Modulation Response
  UID           Communication System Name                           A          B           C          D          VR          Max          Max
                                                                   dB       dBvuV                     dB         mV          dev.        Unc®
                                                                                                                                         (k=2)
 0              Cw                                         x      0.00        0.00       1.00        0.00       134.9      #3.3 %       £4.7%
                                                           Y¥     0.00        0.00       1.00                   134.5
                                                           Z      0.00        0.00       1.00                   145.8
  10021—        GSM—FDD (TDMA, GMSK)                       X      286         71.7       16.2        9.39       148.8      #2.2%       |+4.7%
 DAC                                                       Y      z74         674        14.0                   134.9
                                                           Z      246         70.8       16.0                   134.1
  10061—        IEEE 802.11b WiFi 2.4 GHz                  X      3.86        74.5       22.3        3.60       1479       £0.9%       £+4.7%
 CAB            (DSSS, 11 Mbps)                            Y      4.32        75.1       21.9                   149.2
                                                           Z      3.08        69.7       19.8                   135.9
 10069—         IEEE 802.11a/h WiFi 5 GHz                  X      1116        70.1       24.2       10.56       133.8      £3.0 %      £4.7 %
 CAC            (OFDM, 54 Mbps)                            Y      1116        s9.9       23.3                   133.4
                                                           Z      10.90       69.7       24.0                   140.7
 10077—         IEEE 802.11g WiFi 2.4 GHz                  X      10.27      70.0        24.8       11.00       132.3      £3.0%       £4.7%
 CAB            (DSSS/OFDM, 54 Mbps)                       Y      10.50      70.4        24.7                   133.1
                                                           Z      10.09      69.8        24.7                   138.1
 10172—        LTE—TDD (SC—FDMA, 1 RB, 20                  X      6.24       71.6        25.1        9.21       136.7      £3.0%       £4.7%
 CAG           MHz, QPSK)                                  Y¥     6.55       72.1        24.8                   139.6
                                                           Z      5.89       70.4        24.4                   143.0
 10173—         LTE—TDD (SC—FDMA, 1 RB, 20                 X      6.60       72.6        25.6        9.48       135.6      #27%        |+4.7%
 CAG            MHz, 16—QAM)                               Y¥     _6.95      73.0        25.2                   138.7
                                                           Z      6.20       714         24.9                   140.9
 10174—        LTE—TDD (SC—FDMA, 1 RB, 20                  xX     7.30       72.9        26.4       10.25       135.9      #2.2%       £4.7%
 CAG           MHz, 64—QAM)                                Y      7.63        73.3       26.                    139.1
                                                           Z      6.88       71.6        25.7                   141.1
 10295—        CDMA2000, RC1, SO3, 1/8th                   xX     6.03       71.0        27.2       1249        12814      #14%        £4.7%
 AAB           Rate 25 fr.                                 Y      s.36        71.0       26.3                   115.8
                                                           Z      5.50       68.7        25.8                   114.5


 The reported uncertainty of measurement is stated as the standard uncertainty of measurement
 multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
 probability of approximately 95%.


® Numerical linearization parameter: uncertainty not required.
  Uncertainty is determined using the max. deviation from linear response applying rectangular distribution and is expressed for the square of the
field value.




Certificate No: EF3—4047_Jan19                                      Page 4 of 9


EF3DV3 — SN:4047                                                                January 30, 2019


DASY/EASY — Parameters of Probe: EF3DV3 — SN:4047
Sensor Frequency Model Parameters

                                           Sensor X                 Sensor Y   Sensor Z
 Frequency Corr. (LF)                       —0.33                    —0.24      5.86
 Frequency Corr. (HF)                       2.82                     2.82       2.82

Sensor Model Parameters



Other Probe Parameters
 Sensor Arrangement                                                               Rectangular
 Connector Angle (°)                                                                       —32.7
 Mechanical Surface Detection Mode                                                     enabled
 Optical Surface Detection Mode                                                        disabled
 Probe Overall Length                                                                  335 mm
 Probe Body Diameter                                                                      12 mm
 Tip Length                                                                               25 mm
 Tip Diameter                                                                             4 mm
 Probe Tip to Sensor X Calibration Point                                                1.5 mm
 Probe Tip to Sensor Y Calibration Point                                                1.5 mm
 Probe Tip to Sensor Z Calibration Point                                               1.5 mm




Certificate No: EF3—4047_Jan19                        Page 5 of 9


EFSDV3 — SN:4047                                                                      January 30, 2019




                                 Receiving Pattern (¢), 9 = 0°

                     £2600 MHz,TEM,O°                             £=1800 MHz,R22,0°




            i                    o                           uy               *




                 #        *          *     *                  *       *   °       *        e
                To        x          ¥     2                 To       x           ¥        2




                                 Receiving Pattern (¢), 8 = 90°

                     £=600 MHz,TEM,90°                            f=1800 MHz,R22,90°




Certificate No: EF3—4047_Jan19                 Page 6 of 9


EF3DV3 — SN:4047                                                                                January 30, 2019




                                   Receiving Pattern (¢), 9 = 0°




                                                                0
                                                              Roll[]
                                                                       |80HH1             25®!dfi1


                                 Uncertainty of Axial Isotropy Assessment: £ 0.5% (k=2)




                                  Receiving Pattern (¢), 9 = 90°
     Ertor [48]




                                                              Roll[]

                       10&"«1                  BOF.MLZ                 180'6.T\AIH1       zslfi‘fiHz

                                 Uncertainty of Axial Isotropy Assessment: £ 0.5% (k=2)




Certificate No: EF3—4047_Jan19                           Page 7 of 9


EF3DV3 — SN:4047                                                                                               January 30, 2019




                                               Dynamic Range f(E—field)
                                                      (TEM cell, f= 900 MHz)




                        104

                   3.
                   "G
                   m
                    5   10
                   3
                   C
                   £

                        102




                        10‘




                              10°                          101                       10                   10
                                                                   E total [V/im|
                                                    ([¢]
                                               not compensated                        compensated




                              2           1O    |


                        m          |
                        3
                        i     05m—m—*fi=
                                L    |
                            aof ced




                                  100                      101                      102             10+
                                                                  E total [V/m]l
                                               hot compensated                      compensated


                                        Uncertainty of Linearity Assessment: £0.6% (k=2)




Certificate No: EF3—4047_Jan19                                   Page 8 of 9


EFSDV3 — SN:4047                                                                                January 30, 2019




                                      Deviation from Isotropy in Air
                                                  Error (§, 8), £= 900 MHz

                       Deviation




                              410     —0%   —08   —04   —02    00


                                   Uncertainty of Spherical Isotropy Assessment: £ 2.6% (k=2)




Certificate No: EF3—4047_Jan19                             Page 9 of 9


Calibration Laboratory of                                                                                          Schweizerischer Kalibrierdienst
Schmid & Partner                                                                                                   Service suisse d‘étalonnage
  Engineering AG                                                                                                   Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                       Swiss Calibration Service


Accredited by the Swiss Accreditation Service (SAS)                                              Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client       Sporton                                                                             Certificate No: DAE4—778_May18

CALIBRATION CERTIFICATE
 Object                                DAE4 — SD 000 DO4 BM — SN: 778


 Calibration procedure(s)              QA CAL—06.v29
                                       Calibration procedure for the data acquisition electronics (DAE)



 Calibration date:                     May 25, 2018




 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)


 Primary Standards                      ID #                       Cal Date (Certificate No.)                          Scheduled Calibration
 Keithley Multimeter Type 2001          SN: 0810278                31—Aug—17 (No:21092)                                Aug—18

 Secondary Standards                    ID #                       Check Date (in house)                               Scheduled Check
 Auto DAE Calibration Unit              SE UWS 053 AA 1001         04—<Jan—18 (in house check)                         In house check: Jan—19
 Calibrator Box V2.1                    SE UMS 006 AA 1002        04—Jan—18 (in house check)                           In house check: Jan—19




                                        Name                                   Function                                 Signature
 Calibrated by:                         Dominique Steffen                      Laboratory Technician                  ‘%,\



 Approved by:                           Sven KGhn                              Deputy Manager
                                                                                                                          ix. tol        i
                                                                                                                                             W
                                                                                                                        Issued: May 25, 2018
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




Certificate No: DAE4—778_May18                                        Page 1 of 5


Calibration Laboratory of                                                      S   Schweizerischer Kalibrierdienst
Schmid & Partner                                                                   Service suisse d'etalonnage
                                                                               C
 Engineering AG                                                                    Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                   s   Swiss Calibration Service


Accredited by the Swiss Accreditation SeNice (SAS)                             Accreditation No.:   SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for t he recognition of calibration certificates



Glossary
DAE                          data acquisition electronics
Connector angle              information used in DASY system to align probe sensor X to the robot
                             coordinate system.

Methods Applied and Interpretation of Parameters
  •   DC Voltage Measurement: Calibration Factor assessed for use in DASY system by
     comparison with a calibrated instrument traceable to national standards. The figure given
     corresponds to the full scale range of the voltmeter in the respective range.
    •    Connector angle: The angle of the connector is assessed measuring the angle
         mechanically by a tool inserted. Uncertainty is not required .
    •    The following parameters as documented in the Appendix contain technical information as a
         result from the performance test and require no uncertainty.
         •     DC Voltage Measurement Linearity: Verification of the Linearity at + 10% and -10% of
               the nominal calibration voltage. Influence of offset voltage is included in this
               measurement.
         •     Common mode sensitivity: Influence of a positive or negative common mode voltage on
               the differential measurement.
         •     Channel separation: Influence of a voltage on the neighbor channels not subject to an
               input voltage.
         •     AD Converter Values with inputs shorted: Values on the internal AD converter
               corresponding to zero input voltage
         •     Input Offset Measurement Output voltage and statistical results over a large number of
               zero voltage measurements.
         •     Input Offset Current: Typical value for information; Maximum channel input offset
               current, not considering the input resistance.
         •     Input resistance: Typical value for information: DAE input resistance at the connector,
               during internal auto-zeroing and during measurement.
         •     Low Battery Alarm Voltage: Typical value for information . Below this voltage, a battery
               alarm signal is generated.
         •     Power consumption: Typical value for information. Supply currents in various operating
               modes.




Certificate No: DAE4-778_May18                                   Page 2 of 5


DC Voltage Measurement
   AID - Converter Resolution nominal
       High Range:          1LSB;     6.1µV,         full range; -100 ... +300 mV
       LowRange:            1LS8;      61nV,         fullrange; -1 .......+3mV
   DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec

     Calibration Factors            X                        y                      z
     High Range            404.721 ± 0.02% (k;2)   403.519 ± 0.02% (k;2)   405.076 ± 0.02% (k;2)

     Low Range             3.98715 ± 1.50% (k;2)   3.96471 ± 1.50% (k;2)   4.00070 ± 1.50% (k;2)



Connector Angle

     Connector Angle to be used in DASY system                                  269.0   °±1 °




Certificate No: DAE4-778_May18                     Page 3 of 5


Appendix (Additional assessments outside the scope of SCS0108)

1. DC Voltaae Linearitv
      High Range                               Reading (µV)          Difference (µ V)              Error(%)
      ChannelX        + Input                   199995.64                    0.22                   0.00
     ChannelX         + Input                   20002.64                     0.86                   0.00
     ChannelX         - Input                   -19997.90                    3.08                  -0.02
     Channel Y        + Input                   199995.52                    0.45                   0.00
     Channel Y        + Input                   20001.45                    -0.24                  -0.00
     ChannelY         - Input                   -19999.33                    1.69                  -0.01
     Channel Z        + Input                   199995.39                    0.09                   0.00
     Channel Z        + Input                    19999.28                   -2.37                  -0.01
     Channel Z        - Input                   -20004.97                   -3.83                   0.02


     Low Range                                 Reading (µV)          Difference (µV)               Error(%)
     Channel X        + Input                    2001.37                     0.09                   0.00
     Channel X        + Input                    201.71                      0.03                   0.02
     ChannelX        - Input                     -198.71                    -0.55                   0.28
     Channel Y       + Input                     2002.06                     0.78                   0.04
     ChannelY        + Input                     201.56                     -0.13                  -0.07
     Channel Y       - Input                     -198.85                    -0.61                   0.31
     ChannelZ        + Input                     2001.83                    0.60                    0.03
     ChannelZ        + Input                     200.63                     -1.14                  -0.57

     ChannelZ        - Input                     -199.30                    -0.95                   0.48



2. Common mode sensitivity
    DASY measurement parameters: Auto Zero Time: 3 sec; Measurina time: 3 sec
                        Common mode                       High Range                            Low Range
                        Input Voltage (mV)            Average Reading (µV)                 Average Reading (µV)

    Channel X                           200                      -4.34                           -5.51
                                       - 200                      6.01                           4.80
    Channel Y                           200                       0.02                           -1.10
                                       - 200                      0.55                           0.11
    ChannelZ                            200                      -13.81                         -14.40
                                       -200                      12.18                          11.59



3. Channel separation
    DASY measurement parameters: Auto Zero Time: 3 sec; Measurinn time: 3 sec
                       Input Voltage (mV)         Channel X (µV)          Channel Y (µV)       Channel Z (µV)
    ChannelX                     200                       -                  -0.84                 -2.53
    ChannelY                     200                   8.46                     -                   0.02
    ChannelZ                     200                   4.29                    6.73                      -

Certificate No: DAE4-778_May18                              Page 4 of 5


4. AD-Converter Values with inputs shorted
    DASY measurement parameters: Auto Zero Time: 3 sec; Measurino time: 3 sec

                                                    High Range (LSB)                        Low Range (LSB)

     ChannelX                                               16056                                16906

     Channel Y                                              16191                                17602

     Channel Z                                              16433                                15344



5. Input Offset Measurement
    DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec
    lnout 10MQ
                                                                                                 Std. Deviation
                            Average (µVJ        min. Offset (µVJ         max. Offset (µVJ
                                                                                                      (11Vl
     ChannelX                    -0.05                -1.10                       1.05                  0.43
     ChannelY                    0.23                 -1.15                       1.67                  0.53
     Channel Z                   -0.76                -1.76                       0.94                  0.52



6. Input Offset Current
     Nominal Input circuitry offset current on all channels: <25fA


7. In out Resistance        /Tvpical values for information)
                                                  Zeroing (kOhm)                           Measuring (MOhm)
     ChannelX                                              200                                   200
     Channel Y                                             200                                   200
     Channel Z                                             200                                   200



8. Low Batterv Alarm Voltaae              (Tvpical values for information\
    Typical values                                Alarm Level (VDC)
     Supply(+ Vee)                                                                 +7.9
     Supply (- Vee)                                                                 -7.6



9. Power Consumotion             (Typical values for information)
    Typical values                          Switched off (mA)        Stand by (mA)            Transmitting (mA)
    Supply(+ Vee)                                  +0.01                    +6                         +14
    Supply (- Vee)                                 -0.01                     -8                        -9




Certificate No: DAE4-778_May18                             Page 5 of 5