Test Report_20181220_v1 - PY7-35228T_TestRpt_DXX_20181220

FCC ID: PY7-35228T

Test Report

Download: PDF
FCCID_4126939

           FCC RADIO TEST REPORT                                                 Report No. : FR882923-01D




               FCC RADIO TEST REPORT
                 FCC ID               : PY7-35228T
                 Equipment            : GSM/WCDMA/LTE Phone+Bluetooth,
                                DTS/UNII a/b/g/n/ac and NFC
                 Brand Name : Sony
                 Applicant    : Sony Mobile Communications Inc.
                                4-12-3 Higashi-Shinagawa, Shinagawa-ku,
                                Tokyo, 140-0002, Japan
                 Manufacturer : Sony Mobile Communications Inc.
                                4-12-3 Higashi-Shinagawa, Shinagawa-ku,
                                Tokyo, 140-0002, Japan
                 Standard             : FCC Part 15 Subpart C §15.225

The product was received on Aug. 31, 2018 and testing was started from Sep. 15, 2018 and
completed on Nov. 20, 2018. We, SPORTON INTERNATIONAL INC., would like to declare that the
tested sample has been evaluated in accordance with the test procedures and has been in
compliance with the applicable technical standards.

The report must not be used by the client to claim product certification, approval, or endorsement by
TAF or any agency of government.

The test results in this report apply exclusively to the tested model / sample. Without written
approval of SPORTON INTERNATIONAL INC. EMC & Wireless Communications Laboratory, the test
report shall not be reproduced except in full.




            Approved by: Jones Tsai
    SPORTON INTERNATIONAL INC. EMC & Wireless Communications Laboratory
                        No. 52, Huaya 1st Rd., Guishan Dist., Taoyuan City, Taiwan (R.O.C.)
TEL : 886-3-327-3456                                                        Page Number       : 1 of 21
FAX : 886-3-328-4978                                                        Issued Date       : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1                               Report Version    : 02


                FCC RADIO TEST REPORT                                                                                                 Report No. : FR882923-01D




                                                                 Table of Contents
History of this test report .................................................................................................................................... 3
Summary of Test Result ...................................................................................................................................... 4
1. General Description ......................................................................................................................................... 5
    1.1      Product Feature of Equipment Under Test ................................................................................................................. 5
    1.2      Product Specification of Equipment Under Test ......................................................................................................... 5
    1.3      Modification of EUT ...................................................................................................................................................... 5
    1.4      Testing Location ........................................................................................................................................................... 6
    1.5      Applicable Standards ................................................................................................................................................... 6
2. Test Configuration of Equipment Under Test ............................................................................................... 7
    2.1      Descriptions of Test Mode ........................................................................................................................................... 7
    2.2      Connection Diagram of Test System .......................................................................................................................... 8
    2.3      Table for Supporting Units ........................................................................................................................................... 9
    2.4      EUT Operation Test Setup .......................................................................................................................................... 9
3. Test Results .................................................................................................................................................... 10
    3.1      AC Power Line Conducted Emissions Measurement ............................................................................................... 10
    3.2      20dB and 99% OBW Spectrum Bandwidth Measurement ....................................................................................... 12
    3.3      Frequency Stability Measurement ............................................................................................................................. 13
    3.4      Field Strength of Fundamental Emissions and Mask Measurement ....................................................................... 14
    3.5      Radiated Emissions Measurement............................................................................................................................ 16
    3.6      Antenna Requirements .............................................................................................................................................. 19
4. List of Measuring Equipment ....................................................................................................................... 20
5. Uncertainty of Evaluation.............................................................................................................................. 21
Appendix A. Test Results of Conducted Emission Test
Appendix B. Test Results of Conducted Test Items
    B1. Test Result of 20dB Spectrum Bandwidth
    B2. Test Result of Frequency Stability
Appendix C. Test Results of Radiated Test Items
    C1. Test Result of Field Strength of Fundamental Emissions
    C2. Results of Radiated Emissions (9 kHz~30MHz)
    C3. Results of Radiated Emissions (30MHz~1GHz)




TEL : 886-3-327-3456                                                                                                          Page Number                    : 2 of 21
FAX : 886-3-328-4978                                                                                                          Issued Date                    : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1                                                                                 Report Version                 : 02


           FCC RADIO TEST REPORT                                               Report No. : FR882923-01D



                                    History of this test report
    Report No.          Version                             Description                    Issued Date

  FR882923-01D             01         Initial issue of report                              Dec. 10, 2018

  FR882923-01D             02         Revising test data.                                  Dec. 20, 2018




TEL : 886-3-327-3456                                                      Page Number       : 3 of 21
FAX : 886-3-328-4978                                                      Issued Date       : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1                             Report Version    : 02


           FCC RADIO TEST REPORT                                                      Report No. : FR882923-01D



                                       Summary of Test Result
        Report          Ref Std.                                              Result
                                                     Test Items                                    Remark
        Clause          Clause                                             (PASS/FAIL)

                                                                                                  Under limit
           3.1           15.207        AC Power Line Conducted Emissions       Pass               9.00 dB at
                                                                                                  0.573MHz
                        15.215(c)          20dB Spectrum Bandwidth             Pass                    -
           3.2
                         2.1049          99% OBW Spectrum Bandwidth        Reporting only              -


           3.3          15.225(e)                Frequency Stability           Pass                    -

                                                                                                Max level
                                          Field Strength of Fundamental
           3.4       15.225(a)(b)(c)                                           Pass          59.53 dBμV/m at
                                                    Emissions
                                                                                               13.560 MHz
                                                                                                Under limit
                        15.225(d)
           3.5                            Radiated Spurious Emissions          Pass             4.13 dB at
                         15.209
                                                                                               40.680MHz

           3.6           15.203                 Antenna Requirements           Pass                    -




     Reviewed by: Wii Chang
     Report Producer: Natasha Hsieh




TEL : 886-3-327-3456                                                             Page Number          : 4 of 21
FAX : 886-3-328-4978                                                             Issued Date          : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1                                    Report Version       : 02


           FCC RADIO TEST REPORT                                                 Report No. : FR882923-01D


1. General Description
1.1 Product Feature of Equipment Under Test
       GSM/WCDMA/LTE, Bluetooth, DTS/UNII a/b/g/n/ac, FM Receiver, NFC, and GNSS.
                                 Product Specification subjective to this standard
        Antenna Type                                Single loop Antenna

                                                  EUT Information List

                                                                                         Performed
            HW Version               SW Version                S/N
                                                                                         Test Item

                                                          CQ3001BTLD        RF conducted measurement

                  A                     1.129            CQ3001BN5M         Radiated Spurious Emission

                                                         CQ3001BMVB               Conducted Emission

                                                    Accessory List
                                          Model No. : UCH32
                                          S/N:
       AC Adapter
                                          6218W30200215 (for radiated emission)
                                          6218W30200140 (for conducted emission)
                                          Model No. : MH410c
       Earphone
                                          S/N: N/A
                                          Model No. : UCB24
       USB Cable
                                          S/N : N/A
       Note:
       1. Above EUT list used are electrically identical per declared by manufacturer.
       2. Above the accessories list are used to exercise the EUT during test, and the serial number of each
          type of accessories is listed in each section of this report. .
       3. For other wireless features of this EUT, test report will be issued separately.


1.2 Product Specification of Equipment Under Test
                                        Standards-related Product Specification
          Tx/Rx Frequency                                13.56MHz
          Channel Number                                 1
          Type of Modulation                             ASK
        Remark: The above EUT's information was declared by manufacturer. Please refer to the
        specifications or user's manual for more detailed description.


1.3 Modification of EUT
        No modifications are made to the EUT during all test items.



TEL : 886-3-327-3456                                                        Page Number         : 5 of 21
FAX : 886-3-328-4978                                                        Issued Date         : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1                               Report Version      : 02


 seomncas. _FCC RADIO TEST REPORT                                                   Report No. : FR882923—01D

1.4 Testing Location
         Sporton Lab is accredited to ISO 17025 by Taiwan Accreditation Foundation (TAF code : 1190) and
         the FCC designation No. TW1190 and TWO007 under the FCC 2.948(e) by Mutual Recognition
         Agreement (MRA) in FCC Test.
          Test Site                 SPORTON INTERNATIONAL INC.
                                    No.52, Huaya 1st Rd., Guishan Dist.,
                                    Tacyuan City, Taiwan (R.0.C.)
          Test Site Location
                                    TEL: +886—3—327—3456
                                    FAX: +886—3—828—4978
                                                                Sporton Site No.
          Test Site No.
                                                 THO3—HY                                 COO5—HY
          Test Engineer                         Louis Chung                            Jimmy Chang
          Temperature                            22~24"0                                  22~23°C
          Relative Humidity                       58~55%                                  48~50%
         Note: The test site complies with ANSI C63.4 2014 requirement.


          Test Site                 SPORTON INTERNATIONAL INC.
                                    No.58, Aly. 75, Ln. 564, Wenhua 3rd, Rd., Guishan Dist.,
                                    Tacyuan City, Taiwan (R.O.C.)
          Test Site Location
                                    TEL: +886—3—327—0868
                                    FAX: +886—3—827—0855
                                                                Sporton Site No.
          Test Site No.
                                                                    O3CH11—HY
          Test Engineer                                              Ken Wu
          Temperature                                                21~25°C
          Relative Humidity                                          52~57%

         Note: The test site complies with ANSI C63.4 2014 requirement.


1.5 Applicable Standards
         According to the specifications of the manufacturer, the EUT must comply with the requirements of
         the following standards:
         + FCC Part 15 Subpart C §15.225
         + FCC KDB 414788 DO1 Radiated Test Site vO1r01
         + ANSI C63.10—2013




TEL : 886—3—327—3456                                                           Page Number      : 6 of 21
FAX : 886—3—328—4978                                                           Issued Date      : Dec. 20, 2018
Report Template No.: BUS—FR15CNFC Version 2.1                                  Report Version   : 02


           FCC RADIO TEST REPORT                                                     Report No. : FR882923-01D


2. Test Configuration of Equipment Under Test
2.1 Descriptions of Test Mode
        Investigation has been done on all the possible configurations.
        The following table is a list of the test modes shown in this test report.
                                                       Test Items
          AC Power Line Conducted Emissions                   Field Strength of Fundamental Emissions
          20dB Spectrum Bandwidth                             Frequency Stability
          Radiated Emissions 9kHz~30MHz                       Radiated Emissions 30MHz~1GHz


        The EUT pre-scanned in four NFC type, A, B, F, V. The worst type (type F) was recorded in this report.
        Pre-scanned tests, X, Y, Z in three orthogonal panels to determine the final configuration (Z plane as
        worst plane) from all possible combinations.


                                                       Test Cases
               AC
                           Mode 1 : Bluetooth Link + WLAN (2.4GHz) Link + NFC Link + Earphone + Battery +
          Conducted
                                     USB Cable (Charging from Adapter)
           Emission




TEL : 886-3-327-3456                                                            Page Number      : 7 of 21
FAX : 886-3-328-4978                                                            Issued Date      : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1                                   Report Version   : 02


           FCC RADIO TEST REPORT                     Report No. : FR882923-01D


2.2 Connection Diagram of Test System
        <AC Conducted Emissions>




       <For Radiated Emissions Measurement>




TEL : 886-3-327-3456                            Page Number      : 8 of 21
FAX : 886-3-328-4978                            Issued Date      : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1   Report Version   : 02


             FCC RADIO TEST REPORT                                             Report No. : FR882923-01D


2.3 Table for Supporting Units
       Item Equipment              Trade Name   Model Name   FCC ID          Data Cable    Power Cord

        1.   Bluetooth Earphone Sony            SBH20        PY7-RD0010      N/A           N/A

        2.   WLAN AP               ASUS         RT-AC66U     MSQ-RTAC66U     N/A           Unshielded, 1.8m
                                                                                           AC I/P:
                                                                                           Unshielded, 1.2m
        3.   Notebook              DELL         P20G         FCC DoC         N/A
                                                                                           DC O/P:
                                                                                           Shielded, 1.8m
        4.   NFC Card              N/A          N/A          N/A             N/A           N/A

        5.   SD Card               SanDisk      MicroSD HC   FCC DoC         N/A           N/A



2.4 EUT Operation Test Setup
        The EUT was programmed to be in continuously transmitting mode.
        The ancillary equipment, NFC card, is used to make the EUT (NFC) continuously transmit at
        13.56MHz and is placed around 2 cm gap to the EUT.




TEL : 886-3-327-3456                                                      Page Number      : 9 of 21
FAX : 886-3-328-4978                                                      Issued Date      : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1                             Report Version   : 02


           FCC RADIO TEST REPORT                                                   Report No. : FR882923-01D


3. Test Results
3.1 AC Power Line Conducted Emissions Measurement
3.1.1 Limit of AC Conducted Emission

         For equipment that is designed to be connected to the public utility (AC) power line, the radio
         frequency voltage that is conducted back onto the AC power line on any frequency or frequencies
         within the band 150 kHz to 30 MHz shall not exceed the limits in the following table.

               Frequency of Emission                                 Conducted Limit (dBμV)
                         (MHz)                          Quasi-Peak                             Average

                        0.15-0.5                           66 to 56*                           56 to 46*
                          0.5-5                                 56                                46
                          5-30                                  60                                50
         *Decreases with the logarithm of the frequency.


3.1.2 Measuring Instruments

         See list of measuring equipment of this test report.


3.1.3 Test Procedures

         1. The EUT was placed 0.4 meter from the conducting wall of the shielding room, and it was kept at
              least 80 centimeters from any other grounded conducting surface.
         2. Connect EUT to the power mains through a line impedance stabilization network (LISN).
         3. All the support units are connecting to the other LISN.
         4. The LISN provides 50 ohm coupling impedance for the measuring instrument.
         5. The FCC states that a 50 ohm, 50 microhenry LISN should be used.
         6. Both sides of AC line were checked for maximum conducted interference.
         7. The frequency range from 150 kHz to 30 MHz was searched.
         8. Set the test-receiver system to Peak Detect Function and specified bandwidth (IF Bandwidth =
              9kHz) with Maximum Hold Mode. Then measurement is also conducted by Average Detector
              and Quasi-Peak Detector Function respectively.




TEL : 886-3-327-3456                                                          Page Number          : 10 of 21
FAX : 886-3-328-4978                                                          Issued Date          : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1                                 Report Version       : 02


           FCC RADIO TEST REPORT                     Report No. : FR882923-01D


3.1.4 Test setup




3.1.5 Test Result of AC Conducted Emission

         Please refer to Appendix A.




TEL : 886-3-327-3456                            Page Number      : 11 of 21
FAX : 886-3-328-4978                            Issued Date      : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1   Report Version   : 02


              FCC RADIO TEST REPORT                                             Report No. : FR882923-01D


3.2 20dB and 99% OBW Spectrum Bandwidth Measurement
3.2.1 Limit

         Intentional radiators must be designed to ensure that the 20dB and 99% emission bandwidth in the
         specific band 13.553~13.567MHz.


3.2.2 Measuring Instruments

         See list of measuring instruments of this test report.


3.2.3 Test Procedures

         1.    The spectrum analyzer connected via a receive antenna placed near the EUT in peak Max hold
               mode.
         2.    The resolution bandwidth of 1 kHz and the video bandwidth of 3 kHz were used.
         3.    Measured the spectrum width with power higher than 20dB below carrier.
         4.    Measured the 99% OBW.


3.2.4 Test Setup




3.2.5 Test Result of Conducted Test Items

         Please refer to Appendix B.




TEL : 886-3-327-3456                                                       Page Number         : 12 of 21
FAX : 886-3-328-4978                                                       Issued Date         : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1                              Report Version      : 02


              FCC RADIO TEST REPORT                                                Report No. : FR882923-01D


3.3 Frequency Stability Measurement
3.3.1 Limit

         The frequency tolerance of the carrier signal shall be maintained within +/- 0.01% (100ppm) of the
         operating frequency over a temperature variation of -20 degrees to +50 degrees C at normal supply
         voltage, and for a variation in the primary supply voltage from 85% to 115% of the rated supply
         voltage at a temperature of 20 degrees C. For battery operated equipment, the equipment tests shall
         be performed using a new battery.


3.3.2 Measuring Instruments

         See list of measuring instruments of this test report.


3.3.3 Test Procedures

         1.    The spectrum analyzer connected via a receive antenna placed near the EUT.
         2.    EUT have transmitted signal and fixed channelize.
         3.    Set the spectrum analyzer span to view the entire emissions bandwidth.
         4.    Set RBW = 1 kHz, VBW = 3 kHz with peak detector and maxhold settings.
         5.    The fc is declaring of channel frequency. Then the frequency error formula is (fc-f)/fc × 106 ppm
               and the limit is less than ±100ppm.
         6.    Extreme temperature rule is -20°C~50°C.


3.3.4 Test Setup




3.3.5 Test Result of Conducted Test Items

         Please refer to Appendix B.




TEL : 886-3-327-3456                                                          Page Number       : 13 of 21
FAX : 886-3-328-4978                                                          Issued Date       : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1                                 Report Version    : 02


           FCC RADIO TEST REPORT                                                Report No. : FR882923-01D


3.4 Field Strength of Fundamental Emissions and Mask Measurement
3.4.1 Limit

 Rules and specifications                             FCC CFR 47 Part 15 section 15.225
         Description             Compliance with the spectrum mask is tested with RBW set to 9kHz.
                                   Field Strength      Field Strength     Field Strength     Field Strength
  Freq. of Emission (MHz)
                                   (μV/m) at 30m     (dBμV/m) at 30m    (dBμV/m) at 10m      (dBμV/m) at 3m
        1.705~13.110                      30                29.5              48.58                  69.5
       13.110~13.410                     106                40.5              59.58                  80.5
       13.410~13.553                     334                50.5              69.58                  90.5
       13.553~13.567                   15848                84.0             103.08               124.0
       13.567~13.710                     334                50.5              69.58                  90.5
       13.710~14.010                     106                40.5              59.58                  80.5
       14.010~30.000                      30                29.5              48.58                  69.5


3.4.2 Measuring Instruments

       See list of measuring instruments of this test report.




TEL : 886-3-327-3456                                                       Page Number      : 14 of 21
FAX : 886-3-328-4978                                                       Issued Date      : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1                              Report Version   : 02


              FCC RADIO TEST REPORT                                                Report No. : FR882923-01D


3.4.3 Test Procedures

         1.    Configure the EUT according to ANSI C63.10. The EUT was placed on the top of the turntable
               0.8 meter above ground. The phase center of the loop receiving antenna mounted antenna tower
               was placed 3 meters far away from the turntable.
         2.    Power on the EUT and all the supporting units. The turntable was rotated by 360 degrees to
               determine the position of the highest radiation.
         3.    The height of the receiving antenna was fixed at one meter above ground to find the maximum
               emissions field strength.
         4.    For Fundamental emissions, use the receiver to measure QP reading.
         5.    When the radiated emissions limits are expressed in terms of the average value of the emissions,
               and pulsed operation is employed, the measurement field strength shall be determined by
               averaging over one complete pulse train, including blanking intervals, as long as the pulse train
               does not exceed 0.1 seconds. As an alternative (provided the transmitter operates for longer
               than 0.1 seconds) or in cases where the pulse train exceeds 0.1 seconds, the measured field
               strength shall be determined from the average absolute voltage during a 0.1 second interval
               during which the field strength is at its maximum value.
         6.    Compliance with the spectrum mask is tested with RBW set to 9kHz.
               Note: Emission level (dBμV/m) = 20 log Emission level (μV/m).


3.4.4 Test Setup

         For radiated emissions below 30MHz




3.4.5 Test Result of Field Strength of Fundamental Emissions and Mask

         Please refer to Appendix C.




TEL : 886-3-327-3456                                                          Page Number       : 15 of 21
FAX : 886-3-328-4978                                                          Issued Date       : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1                                 Report Version    : 02


           FCC RADIO TEST REPORT                                                      Report No. : FR882923-01D


3.5 Radiated Emissions Measurement
3.5.1 Limit

         The field strength of any emissions which appear outside of 13.110 ~14.010MHz band shall not
         exceed the general radiated emissions limits.
                     Frequencies                           Field Strength                 Measurement Distance
                         (MHz)                                    (μV/m)                          (meters)
                     0.009~0.490                            2400/F(kHz)                             300
                     0.490~1.705                            24000/F(kHz)                            30
                      1.705~30.0                                   30                               30
                        30~88                                      100                               3
                        88~216                                     150                               3
                        216~960                                    200                               3
                      Above 960                                    500                               3


3.5.2 Measuring Instruments

         See list of measuring instruments of this test report.


3.5.3 Measuring Instrument Setting

         The following table is the setting of receiver:
          Receiver Parameter                               Setting
          Attenuation                                      Auto
          Frequency Range: 9kHz~150kHz                     RBW 200Hz for QP
          Frequency Range: 150kHz~30MHz                    RBW 9kHz for QP
          Frequency Range: 30MHz~1000MHz                   RBW 120kHz for Peak
         Note: The emission limits shown in the above table are based on measurements employing a CISPR
         quasi-peak detector except for the frequency bands 9-90 kHz and 110-490 kHz. Radiated emission
         limits in these two bands are based on measurements employing an average detector.




TEL : 886-3-327-3456                                                             Page Number       : 16 of 21
FAX : 886-3-328-4978                                                             Issued Date       : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1                                    Report Version    : 02


              FCC RADIO TEST REPORT                                                Report No. : FR882923-01D


3.5.4 Test Procedures

         1.    Configure the EUT according to ANSI C63.10. The EUT was placed on the top of the turntable
               0.8 meter above ground. The phase center of the receiving antenna mounted on the top of a
               height-variable antenna tower was placed 3 meters far away from the turntable.
         2.    Power on the EUT and all the supporting units. The turntable was rotated by 360 degrees to
               determine the position of the highest radiation.
         3.    The height of the broadband receiving antenna was varied between one meter and four meters
               above ground to find the maximum emissions field strength of both horizontal and vertical
               polarization.
         4.    For each suspected emissions, the antenna tower was scan (from 1 M to 4 M) and then the
               turntable was rotated (from 0 degree to 360 degrees) to find the maximum reading.
         5.    Set the test-receiver system to Peak or CISPR quasi-peak Detect Function with specified
               bandwidth under Maximum Hold Mode.
         6.    When the radiated emissions limits are expressed in terms of the average value of the emissions,
               and pulsed operation is employed, the measurement field strength shall be determined by
               averaging over one complete pulse train, including blanking intervals, as long as the pulse train
               does not exceed 0.1 seconds. As an alternative (provided the transmitter operates for longer
               than 0.1 seconds) or in cases where the pulse train exceeds 0.1 seconds, the measured field
               strength shall be determined from the average absolute voltage during a 0.1 second interval
               during which the field strength is at its maximum value.
         7.    In case the emission is lower than 30MHz, loop antenna has to be used for measurement and
               the recorded data should be QP measured by receiver.




TEL : 886-3-327-3456                                                          Page Number       : 17 of 21
FAX : 886-3-328-4978                                                          Issued Date       : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1                                 Report Version    : 02


           FCC RADIO TEST REPORT                                                  Report No. : FR882923-01D


3.5.5 Test Setup

         For radiated emissions below 30MHz




         For radiated emissions above 30MHz




3.5.6 Test Result of Radiated Emissions Measurement

         Please refer to Appendix C.


         Remark: There is a comparison data of both open-field test site and alternative test site -
         semi-Anechoic chamber according to 414788 D01 Radiated Test Site v01r01, and the result came
         out very similar.




TEL : 886-3-327-3456                                                         Page Number       : 18 of 21
FAX : 886-3-328-4978                                                         Issued Date       : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1                                Report Version    : 02


           FCC RADIO TEST REPORT                                                     Report No. : FR882923-01D


3.6 Antenna Requirements
3.6.1 Standard Applicable

         Except for special regulations, the Low-power Radio-frequency Devices must not be equipped with
         any jacket for installing an antenna with extension cable. An intentional radiator shall be designed to
         ensure that no antenna other than that furnished by the responsible party shall be used with the
         device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to
         the intentional radiator shall be considered sufficient to comply with the provisions of this Section. The
         manufacturer may design the unit so that the user can replace a broken antenna, but the use of a
         standard antenna jack or electrical connector is prohibited.
         The use of a permanently attached antenna or of an antenna that uses a unique coupling to the
         intentional radiator shall be considered sufficient to comply with the rule.


3.6.2 Antenna Anti-Replacement Construction

         An embedded-in antenna design is used.




TEL : 886-3-327-3456                                                            Page Number       : 19 of 21
FAX : 886-3-328-4978                                                            Issued Date       : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1                                   Report Version    : 02


       seonton cas.   FCC RADIO TEST REPORT                                                                   Report No. : FR882923—01D


      4.         List of Measuring Equipment
                                                         .                     20.     Calibration
Instrument            Manufacturer|    Model No.      Serial No.   |Characteristics        Date           Test Date           Due Date          Remark

     ACSource
         Power        ho powEn         AFG—500W      F104070011      50Hz~60Hz        Mar. 21, 2018 Oct. 02, 2018 mar. 20, 2019 Conducted
                                                                                                                                (THO3—HY)
     Spectrum           Rohde &                                                                                                                Conducted
     Analyzer           Schwarz          FSP30         101329       9KHz~30GHz        Jun. 29, 2018     Oct. 02, 2018       Jun. 28, 2019      (THhog—Hy)

Temperature                                                            im ~70%                                                                 Conducted
  Chamber                ESPEC          SU—641        92013721       30°C ~70C        Dec. 06, 2017     Oct. 02, 2018       Dec. 05, 2019      (THoB—Hy)

     AC Power               .                                                                                                                 Conduction
      Source            ChainTek      APC—1000W          N/A             N/A               N/A          Sep. 15, 2018           N/A           (COOS—HY)

     EMI Test           Rohde &                                                                                                               Conduction
     Receiver           Schwarz          ESA3          102388       9KHz~3.6GHz       Dec. 08, 2017     Sep. 15, 2018       Dec. 07, 2018     (COO5—HY)

                        Rohde &                                                                                                               Conduction
       LISN             Schwarz         ENV216         100080       9KHz~30MHz        Nov. 30, 2017     Sep. 15, 2018       Nov. 29, 2018     (COOS—HY)

                        Rohde &          EMC32                                                                                                Conduction
     Software           Schwarz          v10.30          N/A             N/A               N/A          Sep. 15, 2018           N/A           (COO5—HY)

                        HUBER +                                                                                                               Conduction
     LF Cable           SUHNER         RG—214/U         LFO1             N/A          Jan. 03, 2018     Sep. 15, 2018       Jan. 02, 2019     (Coos—Hy)

       hm               Rohde &                                                                                                               Conduction
Pulse Limiter           Schwarz         ESH3—Z2        100851            N/A          Jan. 03, 2018     Sep. 15, 2018       Jan. 02, 2019     (Coos—Hy)

 ;                                        CBL        35414&AT—NO                                                                               Radiation
Bilog Antenna           TESEQ         B111D&N—6—06       602        30MHz~1GHz        Oct. 30, 2018     Nov. 20, 2018       Oct. 29, 2019     (O3CH11—HY)

                        Rohde &                                                                                                                Radiation
Loop Antenna            Schwarz         HFH2—Z2        100488      9 kHz~30 MHz       Nov. 23, 2017     Nov. 20, 2018       Nov. 22, 2018     (O3CH11—HY)

     EMI Test                .                                                                                                              Radiation
     Receiver           Keysight      N3O3BA(MXE) MY55420170             N/A          Mar. 06, 2018     Nov. 20, 2018       Mar. 05, 2019 (O3CH11—HY)

     Spectrum                .                                                                                                                Radiation
     Analyzer           Keysight        N3O10A       MY54200486|   10Hz ~ 44GHz       Oct. . 19, 2018   Nov.
                                                                                                         ov. 20, 20, 2018   Oct. . 18, 2019 (O3CH11—HY)

     Amplifier
         P             SONOMA             B10N         187312        9kHz~1GHz        Jan. tz
                                                                                            16, 2018 Nov.ho
                                                                                                          20, 2018 Jan. tC
                                                                                                                         15, 2019              Radiation
                                                                                                                                          (O3CH11—HY)
         .                mus         WHK20/1000                        .                                                                   Radiation
       Filter          Wainwright       crmoss           SN2       20M High Pass      Sep. 16, 2018     Nov. 20, 2018       Sep. 15, 2019 (O3CHT1—HY)

                        HUBER +        SUCOFLEX                                                                                             Radiation
     RF Cable           SUHNER            104        MY9837/4PE        9K—30M         Mar. 14, 2018     Nov. 20, 2018       Mar. 13, 2019 (O3CH11—HY)

                        HUBER +        SUCOFLEX                                                                                             Radiation
     RF Cable           SUHNER            104         MY9837/4        30M—18G         Mar. 14, 2018     Nov. 20, 2018       Mar. 13, 2019 (O3CH11—HY)

                        HUBER +        SUCOFLEX                                                                                             Radiation
     RF Cable           SUHNER            102         MY2589/2        30M—40G         Mar. 14, 2018     Nov. 20, 2018       Mar. 13, 2019 (O3CH11—HY)

                                      AM—BS—4500—                                                                                               Radiation
Antenna Mast             EMEC              s             N/A            1~4m               N/A          Nov. 20, 2018           N/A           (O3CHT1—HY)

                                                                     Control Turn                                                               Radiation
     Controller          EMEC           EM 1000          N/A       table & Ant Mast        N/A          Nov. 20, 2018           N/A           (O3CH11—HY)

                                                                                                                                                Radiation
 Turn Table              EMEC           TT 2000          N/A        0~360 Degree           N/A          Nov. 20, 2018           N/A           (O3CHT1—HY)

Hygrometer
 Y9                     TECPEL         DTN—303B       TP140325           N/A          Nov.[2
                                                                                           05, 2018 Nov."Cn
                                                                                                         20, 2018 Nov.[
                                                                                                                      04, 2019 (O3CHt1—HY)
                                                                                                                                 Radiation
                             :             E3                                                                                                   Radiation
     Software            Audix         6.2009—8—24    RK—001042          N/A               N/A          Nov. 20, 2018           N/A           (O3CHT1—HY)




     TEL : 886—3—327—3456                                                                               Page Number              : 20 of 21
      FAX : 886—3—328—4978                                                                              Issued Date              : Dec. 20, 2018
      Report Template No.: BUS—FR15CNFC Version 2.1                                                     Report Version           : 02


           FCC RADIO TEST REPORT                                        Report No. : FR882923-01D


5. Uncertainty of Evaluation
       Uncertainty of Conducted Emission Measurement (150 kHz ~ 30 MHz)
        Measuring Uncertainty for a Level of Confidence
                                                                           2.20
                     of 95% (U = 2Uc(y))


       Uncertainty of Radiated Emission Measurement (9 kHz ~ 30 MHz)
        Measuring Uncertainty for a Level of Confidence
                                                                           3.45
                     of 95% (U = 2Uc(y))


       Uncertainty of Radiated Emission Measurement (30 MHz ~ 1000 MHz)
        Measuring Uncertainty for a Level of Confidence
                                                                           5.20
                     of 95% (U = 2Uc(y))




TEL : 886-3-327-3456                                               Page Number      : 21 of 21
FAX : 886-3-328-4978                                               Issued Date      : Dec. 20, 2018
Report Template No.: BU5-FR15CNFC Version 2.1                      Report Version   : 02


 seomncas. _FCC RADIO TEST REPORT                 Report No. : FR882923—01D


Appendix A. Test Results of Conducted Emission Test
                                          Temperature :         22~23C
         Test Engineer :   |Jimmy Chang   Relative Humidity :   |48—50%




TEL : 886—3—327—3456                          Page Number       : A1 of Ad
FAX : 886—3—328—4978


EUT Information
Report NO :                                            882923-01
Test Mode :                                            Mode 1
Test Voltage :                                         120Vac/60Hz
Phase :                                                Line


                                                                   F u ll S p e c tru m


                       100


                       90


                       80


                       70

                                                                                                        C IS P R -Q P L im it a t M a in P o rts
       Level in dBuV




                       60

                                                                                                    C IS P R -A v e L im it a t M a in P o rts
                       50


                       40


                       30


                       20


                       10


                        0
                        150k        3 0 0 4 0 05 0 0    8 0 01 M            2M      3M 4M 5M 6              8 10M           20M 30M
                                                                     F re q u e n c y in H z




Final_Result
  Frequency                  QuasiPeak     CAverage        Limit       Margin       Line       Filter       Corr.
    (MHz)                     (dBuV)        (dBuV)        (dBuV)        (dB)                                (dB)
      0.154500                       ---       34.25        55.75        21.50     L1      OFF               19.5
      0.154500                    45.97           ---       65.75        19.78     L1      OFF               19.5
      0.192750                       ---       32.08        53.92        21.84     L1      OFF               19.5
      0.192750                    43.68           ---       63.92        20.24     L1      OFF               19.5
      0.494250                       ---       27.35        46.10        18.75     L1      OFF               19.5
      0.494250                    32.51           ---       56.10        23.59     L1      OFF               19.5
      0.573000                       ---       37.00        46.00         9.00     L1      OFF               19.5
      0.573000                    43.92           ---       56.00        12.08     L1      OFF               19.5
      0.638250                       ---       29.27        46.00        16.73     L1      OFF               19.6
      0.638250                    39.02           ---       56.00        16.98     L1      OFF               19.6
      1.763250                       ---       23.44        46.00        22.56     L1      OFF               19.6
      1.763250                    27.09           ---       56.00        28.91     L1      OFF               19.6
      4.634250                       ---       25.19        46.00        20.81     L1      OFF               19.7
      4.634250                    27.44           ---       56.00        28.56     L1      OFF               19.7
     13.560000                       ---       37.38        50.00        12.62     L1      OFF               20.0
     13.560000                    49.51           ---       60.00        10.49     L1      OFF               20.0


EUT Information
Report NO :                                            882923-01
Test Mode :                                            Mode 1
Test Voltage :                                         120Vac/60Hz
Phase :                                                Neutral


                                                                   F u ll S p e c tru m


                       100


                       90


                       80


                       70

                                                                                                        C IS P R -Q P L im it a t M a in P o rts
       Level in dBuV




                       60

                                                                                                    C IS P R -A v e L im it a t M a in P o rts
                       50


                       40


                       30


                       20


                       10


                        0
                        150k        3 0 0 4 0 05 0 0    8 0 01 M            2M      3M 4M 5M 6              8 10M           20M 30M
                                                                     F re q u e n c y in H z




Final_Result
  Frequency                  QuasiPeak     CAverage        Limit       Margin       Line       Filter       Corr.
    (MHz)                     (dBuV)        (dBuV)        (dBuV)        (dB)                                (dB)
      0.152250                       ---       32.65        55.88        23.23     N       OFF               19.5
      0.152250                    49.37           ---       65.88        16.51     N       OFF               19.5
      0.161250                       ---       34.16        55.40        21.24     N       OFF               19.5
      0.161250                    47.20           ---       65.40        18.20     N       OFF               19.5
      0.183750                       ---       30.18        54.31        24.13     N       OFF               19.5
      0.183750                    41.01           ---       64.31        23.30     N       OFF               19.5
      0.186000                       ---       27.59        54.21        26.62     N       OFF               19.5
      0.186000                    39.19           ---       64.21        25.02     N       OFF               19.5
      0.276000                       ---       30.33        50.94        20.61     N       OFF               19.5
      0.276000                    41.04           ---       60.94        19.90     N       OFF               19.5
      0.575250                       ---       31.83        46.00        14.17     N       OFF               19.5
      0.575250                    37.28           ---       56.00        18.72     N       OFF               19.5
      2.253750                       ---       23.21        46.00        22.79     N       OFF               19.5
      2.253750                    24.76           ---       56.00        31.24     N       OFF               19.5
      4.789500                       ---       25.35        46.00        20.65     N       OFF               19.7
      4.789500                    29.15           ---       56.00        26.85     N       OFF               19.7
     13.560000                       ---       36.75        50.00        13.25     N       OFF               20.1
     13.560000                    47.84           ---       60.00        12.16     N       OFF               20.1


                            FCC RADIO TEST REPORT                                                                                               Report No. : FR882923-01D



       Appendix B. Test Results of Conducted Test Items
          B1. Test Result of 20dB Spectrum Bandwidth

                  Test mode                             NFC Tx                                            Test Frequency (MHz)                                13.56
                                                    * RBW   1 kHz   Marker 1 [T1 ]                                                                    * RBW   1 kHz   Marker 1 [T1 ]

                                                    * VBW   3 kHz               -0.96 dBm                                                             * VBW   3 kHz                -0.93 dBm
         Ref   10 dBm        * Att    30 dB         * SWT   20 ms        13.560020000 MHz                   Ref   10 dBm        * Att   30 dB         * SWT   20 ms         13.560020000 MHz

         10                                                         ndB [T1]    20.00 dB                    10                                                        OBW    2.240000000 kHz
                                                                    BW    2.640000000 kHz                                                                             Temp 1 [T1 OBW]
                                                1                                                                                                 1
                                                                    Temp 1 [T1 ndB]          A                                                                                    -15.88 dBm   A
         0                                                                                                  0
                                                                               -21.18 dBm                                                                                   13.558860000 MHz
1 PK *                                                                                             1 PK *
                                                                         13.558660000 MHz                                                                             Temp 2 [T1 OBW]
VIEW                                                                                               VIEW
         -10                                                        Temp 2 [T1 ndB]                         -10                                                                   -15.19 dBm
                                                                                                                                        T1                     T2
                                                                               -20.79 dBm                                                                                   13.561100000 MHz
                                     T1                       T2         13.561300000 MHz
         -20                                                                                                -20



         -30                                                                                                -30



         -40                                                                                                -40


                                                                                             3DB                                                                                               3DB
         -50                                                                                                -50



         -60                                                                                                -60



         -70                                                                                                -70



         -80                                                                                                -80


         -90                                                                                                -90

         Center 13.56 MHz                     1 kHz/                           Span 10 kHz                  Center 13.56 MHz                    1 kHz/                           Span 10 kHz




Date: 2.OCT.2018        09:20:45                                                                   Date: 2.OCT.2018        09:17:01



    20dB Bandwidth (kHz)                                                    2.640                     99% OccupiedBW(kHz)                                                       2.240
                                                                         fL>13.559                                    13.55866                                              Test Result
  Frequency range (MHz)
                                                                         fH<13.561                                    13.56130                                               Complies
       Remark: Because the measured signal is CW adjusting the RBW per C63.10 would not be practical since
       measured bandwidth will always follow the RBW and the result will be approximately twice the RBW.




       TEL : 886-3-327-3456                                                                                                             Page Number                         : B1 of B3
       FAX : 886-3-328-4978


 seomncas. _FCC RADIO TEST REPORT                                            Report No. : FR882923—01D

 B2. Test Result of Frequency Stability
    B3. Voltage vs. Frequency Stability                Temperature vs. Frequency Stability

    Voltage (Vac)        Measurement      Temperature (°‘C)        Time                 Measurement
                        Frequency (MHz)                                                Frequency (MHz)

          120               13.559980            —20                 0                    13.560100
          102               13.559990                                2                    13.560100
          138               13.559980                                5                    13.560100
                                                                    10                    13.560090
                                                 —10                 0                    13.559980
                                                                     2                    13.560000
                                                                     5                    13.560060
                                                                    10                    13.560100
                                                 0                                        13.560100
                                                                                          13.560100
                                                                     5                    13.560100
                                                                    10                    13.560100
                                                 10                  0                    13.560080
                                                                     2                    13.560080
                                                                     5                    13.560080
                                                                    10                    13.560060
                                                 20                                       13.559980
                                                                                          13.559980
                                                                     5                    13.559980
                                                                    10                    13.559980
                                                 30                                       13.560010
                                                                                          13.560000
                                                                     5                    13.559980
                                                                    10                    13.559980
                                                 40                                       13.559960
                                                                                          13.559960
                                                                     5                    13.559960
                                                                    10                    13.559960




TEL : 886—3—327—3456                                                     Page Number       : B2 of B3
FAX : 886—3—328—4978


 seonton cas.   FCC RADIO TEST REPORT                                           Report No. : FR882923—01D




       Voltage vs. Frequency Stability                  Temperature vs. Frequency Stability


     Voltage (Vac)         Measurement      Temperature (°‘C)         Time                 Measurement
                          Frequency (MHz)                                                 Frequency (MHz)

                                                   50                  0                     13.559960
                                                                       2                     13.559960
                                                                       5                     13.559960
                                                                       10                    13.559960
Max.Deviation (MHz)          —0.000020            Max.Deviation (MHz)                        0.000100

Max.Deviation (ppm)            —1.4749            Max.Deviation (ppm)                         7.3746

            Limit          FS < £100 ppm                   Limit                          FS < £100 ppm
       Test Result             PASS                     Test Result                            PASS




TEL : 886—3—327—3456                                                        Page Number       : B3 of B3
FAX : 886—3—328—4978


            FCC RADIO TEST REPORT                                                Report No. : FR882923-01D



Appendix C. Test Results of Radiated Test Items
         C1. Test Result of Field Strength of Fundamental Emissions
          Test Mode :             NFC Tx                     Test Frequency (MHz) 13.56




                                     Distance
          Frequency       Level                  Over      Limit    Read Antenna Cable Ant Table Remark
                                   extrapolation
                                      Factor     Limit     Line     Level Factor Loss Pos Pos
            ( MHz )     ( dBμV/m )     ( dB )    ( dB ) ( dBμV/m ) (dBμV) ( dB ) ( dB ) ( cm ) ( deg )
             13.348       38.61       40      -41.89   40.5      17.47    21       0.14   100       3        QP

             13.56        59.53       40      -64.47    84       38.37   21.02     0.14   100       3        QP




                                     Distance
           Frequency      Level                  Over      Limit    Read Antenna Cable Ant Table Remark
                                   extrapolation
                                      Factor     Limit     Line     Level Factor Loss Pos Pos
             ( MHz )    ( dBμV/m )     ( dB )    ( dB ) ( dBμV/m ) (dBμV) ( dB ) ( dB ) ( cm ) ( deg )
             13.561       56.68       40      -67.32    84       35.52   21.02     0.14   100      64        QP



TEL : 886-3-327-3456                                                      Page Number           : C1 of C5
FAX : 886-3-328-4978


            FCC RADIO TEST REPORT                                              Report No. : FR882923-01D


         C2. Results of Radiated Spurious Emissions (9 kHz~30MHz)
         Test Mode :       NFC Tx                     Polarization :      Horizontal




                                    Distance
          Frequency      Level                  Over      Limit    Read Antenna Cable Ant Table Remark
                                  extrapolation
                                     Factor     Limit     Line     Level Factor Loss Pos Pos
            ( MHz )    ( dBμV/m )     ( dB )    ( dB ) ( dBμV/m ) (dBμV) ( dB ) ( dB ) ( cm ) ( deg )
             0.0191      53.94       80      -68.04   41.98    34.23   19.7     0.01                 Average

            0.06246      53.58       80      -58.11   31.69    33.77   19.8     0.01                 Average

             0.0938      47.41       80      -60.75   28.16    27.8    19.6     0.01                      QP

            0.14068      43.83       80      -60.81   24.64    24.25   19.57    0.01                 Average

             0.1585      52.05       80      -51.55   23.6     32.5    19.53    0.02                 Average

             1.624       44.75       40      -18.64   23.39    25.41   19.28    0.06   100      0         QP

             8.032       45.85       40      -23.65   29.5     25.3    20.43    0.12                      QP

             19.312      38.39       40      -31.11   29.5     16.68   21.54    0.17                      QP

             29.49       38.51       40      -30.99   29.5     16.52   21.79     0.2                      QP




TEL : 886-3-327-3456                                                     Page Number         : C2 of C5
FAX : 886-3-328-4978


            FCC RADIO TEST REPORT                                                   Report No. : FR882923-01D



         Test Mode :        NFC Tx                       Polarization :         Vertical




                                    Distance
          Frequency      Level                  Over      Limit    Read Antenna Cable Ant Table Remark
                                  extrapolation
                                     Factor     Limit     Line     Level Factor Loss Pos Pos
            ( MHz )    ( dBμV/m )     ( dB )    ( dB ) ( dBμV/m ) (dBμV) ( dB ) ( dB ) ( cm ) ( deg )
            0.01925      50.34         80      -71.58    41.92     30.63     19.7    0.01       -       -    Average

            0.07404      43.19         80      -67.03    30.22     23.38     19.8    0.01       -       -    Average

            0.09244      39.88         80      -68.41    28.29     20.27     19.6    0.01       -       -         QP

            0.11108      36.44         80      -70.25    26.69     16.83     19.6    0.01       -       -    Average

            0.34924      46.29         80      -50.45    16.74     26.9     19.37    0.02       -       -    Average

             1.647       33.7          40      -29.57    23.27     14.37    19.27    0.06      100      0         QP

             8.544       36.79         40      -32.71    29.5      16.17     20.5    0.12       -       -         QP

             19.195      36.38         40      -33.12    29.5      14.68    21.53    0.17       -       -         QP

             27.115      36.93         40      -32.57    29.5       15      21.74    0.19       -       -         QP

         Note:
         1. The amplitude of spurious emissions which are attenuated by more than 20dB below the
            permissible value has no need to be reported.
         2. Distance extrapolation factor = 40 log (specific distance / test distance) (dB).




TEL : 886-3-327-3456                                                          Page Number            : C3 of C5
FAX : 886-3-328-4978


            FCC RADIO TEST REPORT                                                     Report No. : FR882923-01D


             Results of Radiated Spurious Emissions (30MHz~1GHz)
         Test Mode :         NFC Tx                     Polarization :             Horizontal




         Frequency       Level    Over      Limit    Read    Antenna     Cable      Preamp Ant Table Remark
                                  Limit     Line     Level    Factor     Loss       Factor Pos       Pos
           ( MHz )     ( dBμV/m ) ( dB ) ( dBμV/m ) (dBμV)    ( dB )     ( dB )      ( dB ) ( cm ) ( deg )
             40.8        24.63   -15.37     40      37.51     18.64      0.87        32.49       -       -         Peak

            149.34       31.69   -11.81    43.5     45.52     16.91      1.61        32.44       -       -         Peak

            175.53       30.51   -12.99    43.5     46.02     15.04      1.74        32.41       -       -         Peak

            533.8        29.9     -16.1     46      35.26     23.84      2.95        32.41       -       -         Peak

            718.6        32.03   -13.97     46      33.38      27        3.41        32.41       -       -         Peak

            958.7        34.78   -11.22     46      29.69     30.95      3.98        31.12      100      0         Peak




TEL : 886-3-327-3456                                                              Page Number         : C4 of C5
FAX : 886-3-328-4978


            FCC RADIO TEST REPORT                                                     Report No. : FR882923-01D



         Test Mode :         NFC Tx                     Polarization :             Vertical




         Frequency       Level    Over      Limit    Read    Antenna     Cable      Preamp Ant Table Remark
                                  Limit     Line     Level    Factor     Loss       Factor Pos       Pos
           ( MHz )     ( dBμV/m ) ( dB ) ( dBμV/m ) (dBμV)    ( dB )     ( dB )      ( dB ) ( cm ) ( deg )
            40.68        35.87    -4.13     40      48.69     18.7       0.87        32.49      100     282        Peak

            59.43        26.39   -13.61     40      46.08     11.68      1.04        32.49       -       -         Peak

            123.96       30.2     -13.3    43.5      43.7     17.38      1.47        32.46       -       -         Peak

            510.7        25.61   -20.39     46      31.14     23.78      2.86        32.39       -       -         Peak

            794.2        31.41   -14.59     46      30.46     28.14       3.6        32.2        -       -         Peak

            953.8        34.43   -11.57     46      29.68     30.74      3.97        31.16       -       -         Peak

         Note:
         1. The amplitude of spurious emissions which are attenuated by more than 20dB below the
             permissible value has no need to be reported.
         2. Emission level (dBμV/m) = 20 log Emission level (μV/m).
         3. Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor= Level.


                                          ─────THE END─────




TEL : 886-3-327-3456                                                              Page Number         : C5 of C5
FAX : 886-3-328-4978



Document Created: 2019-03-31 12:42:58
Document Modified: 2019-03-31 12:42:58