RF Exposure Info

FCC ID: PY3WG121

RF Exposure Info

Download: PDF
FCCID_355356

FCC ID: PY3WG121




                         FCC TEST REPORT

                     REPORT NO.: RF920820R03
                      MODEL NO.: WG121


                     ACCORDING: FCC Guidelines for Human Exposure
                                IEEE C95.1




                      APPLICANT: NETGEAR, INC.

                       ADDRESS: 4500 GREAT AMERICA PARKWAY SANTA
                                CLARA CA95054 U.S.A.




                      ISSUED BY: Advance Data Technology Corporation

                LAB LOCATION: 47 14th Lin, Chiapau Tsun, Linko, Taipei,
                              Taiwan, R.O.C.




                                                                Lab Code: 200102-0

                                                 0528
                                              ILAC MRA




ADT No.: 920820R03


FCC ID: PY3WG121




          RF Exposure Measurement (Mobile Device)
1. Introduction
2.4GHz frequency band is regarded specially as a dangerous band for its heating
harmfulness to the human body. That’s why microwave oven is operating in this
frequency band. The manufacturer whose product is working in this frequency band is
obligatory to prove the harmfulness of his product.
In this document, we try to prove the safety of radiation harmfulness to the human body
for our product. The limit for Maximum Permissible Exposure (MPE) specified in FCC
1.1310 is followed. The Gain of the antenna used in this product is measured in a Fully
Anechoic Chamber (FAC), and the maximum total power input to the antenna is
measured. Through the Friis transmission formula and the maximum gain of the antenna,
we can calculate the distance, away from the product, where the limit of MPE is reached.




2. RF Exposure Limit

According to FCC 1.1310: The criteria listed in the following table shall be used to
evaluate the environmental impact of human exposure to radio-frequency (RF) radiation
as specified in 1.1307(b).




ADT No.: 920820R03


FCC ID: PY3WG121




LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)

   Frequency          Electric Field   Magnetic Field    Power Density    Average Time
     Range           Strength (V/m)    Strength (A/m)      (mW/cm2)         (minutes)
     (MHz)
                     (A)Limits For Occupational / Control Exposures
     30-300               61.4             0.163              1.0              6
   300-1500                …                …               F/300              6
 1500-100,000              …                …                 5                6
              (B)Limits For General Population / Uncontrolled Exposure
     30-300               27.5             0.073              0.2             30
   300-1500                …                …               F/1500            30
 1500-100,000              …                …                 1.0             30
F = Frequency in MHz

3. Friis Formula


Friis transmission formula : Pd = (Pout*G) / (4*pi*r2)

where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm


If we know the maximum Gain of the antenna and the total power input to the antenna,
through the calculation, we will know the MPE value at distance 2.5cm.


Ref. : David K. Cheng, Field and Wave Electromagnetics, Second Edition,
      Page 640, Eq. (11-133).

4. EUT Operating condition
The software provided by Manufacturer enabled the EUT to transmit and receive data at
lowest, middle and highest channel individually.




ADT No.: 920820R03


FCC ID: PY3WG121




5. Classification

The antenna of the product, under normal use condition, is at least 20cm away from the
body of the user. Warming statement for keeping 20cm separation distance and the
prohibition of operating next to a person has been printed on the user’s manual. So, this
product is classified as the Mobile Device.


6. Test Results

6.1. Antenna Gain


The maximum Gain measured in Fully Anechoic Chamber is 2dBi or 1.58(numeric).


6.2. Output Power Into Antenna & MPE value at distance 20cm:


for 802.11b part

                     Channel                                              Limit of
                                  Output Power to Power Density
   Channel          Frequency                                          Power Density
                                   Antenna (mW)     (mW/cm2)
                      (MHz)                                              (mW/cm2)
       1               2412             62.66                  0.020        1.0
       6               2437             62.52                  0.020        1.0
      11               2462             62.37                  0.020        1.0

for 802.11g part

                     Channel                                              Limit of
                                  Output Power to Power Density
   Channel          Frequency                                          Power Density
                                   Antenna (mW)     (mW/cm2)
                      (MHz)                                              (mW/cm2)
       1               2412             62.23                  0.020        1.0
       6               2437             61.94                  0.020        1.0
      11               2462             62.09                  0.020        1.0




ADT No.: 920820R03



Document Created: 2003-09-08 15:51:47
Document Modified: 2003-09-08 15:51:47