SAR test report

FCC ID: PY3WG111U

RF Exposure Info

Download: PDF
FCCID_499556

              Compliance Certification Services Inc.
              Report No: 41129003-SF           FCC ID: PY3WG111U             Date of Issue: Dec. 22, 2004




                              ANSI/IEEE Std. C95.1-1992
                               in accordance with the requirements of
           FCC Report and Order: ET Docket 93-62, and OET Bulletin 65 Supplement C


                                 FCC TEST REPORT

                                               For


             Double 108 Mbps Wireless USB 2.0 Adapter WG111U


                                Trade Name: NETGEAR


                                       Model: WG111U


                                             Issued to

                                   Netgear Incorporated
                         4500 Great America Parkway Santa Clara,
                                     CA95054 U.S.A.


                                             Issued by

                      Compliance Certification Services Inc.
                      No. 11, Wu-Kung 6 Rd, Wu-Ku Hsiang,
                 Wu-Ku Industrial District, Taipei Hsien, (248) Taiwan.
                               TEL: 886-2-2299-9720
                              FAX: 886-2-2299-9721




Note: This report shall not be reproduced except in full, without the written approval of Compliance
 Certification Services Inc. This document may be altered or revised by Compliance Certification
      Services Inc. personnel only, and shall be noted in the revision section of the document.


                                               Page 1                                      Total Page: 32
                                                                                                  Rev. 00


                   Compliance Certification Services Inc.
                   Report No: 41129003-SF                     FCC ID: PY3WG111U                      Date of Issue: Dec. 22, 2004




                                           TABLE OF CONTENTS
1.       CERTIFICATE OF COMPLIANCE (SAR EVALUATION) ................................... 3
2.       EUT DESCRIPTION ..................................................................................................... 4
3.       REQUIREMENTS FOR COMPLIANCE TESTING DEFINED BY THE FCC .... 5
4.       DOSIMETRIC ASSESSMENT SYSTEM................................................................... 5
         4.1      MEASUREMENT SYSTEM DIAGRAM ............................................................. 6
         4.2      SYSTEM COMPONENTS..................................................................................... 7
5.       EVALUATION PROCEDURES ................................................................................ 10
6.       MEASUREMENT UNCERTAINTY ......................................................................... 14
7.       EXPOSURE LIMIT ..................................................................................................... 15
8.  TYPICAL COMPOSITION OF INGREDIENTS FOR LIQUID TISSUE
PHANTOMS............................................................................................................................ 15
9.       MEASUREMENT RESULTS..................................................................................... 16
         9.1      SYSTEM PERFORMANCE CHECK.................................................................. 16
         9.2      TEST LIQUID CONFIRMATION ...................................................................... 18
         9.3      EUT TUNE-UP PROCEDURES.......................................................................... 20
         9.4      SAR MEASUREMENTS RESULTS................................................................... 21
10.      EUT PHOTOS .............................................................................................................. 29
11.      EQUIPMENT LIST & CALIBRATION STATUS................................................... 30
12.      FACILITIES ................................................................................................................. 31
13.      REFERENCES ............................................................................................................. 31
14.      ATTACHMENTS......................................................................................................... 32




                                                              Page 2                                                           Rev. 00


          c cs        Compliance Certification Services Inc.
                      Report No: 41129003—SF                FCC ID: PY3WGIMU              Date of Issue: Dec. 22. 2004



    L. CERTIFICATE OF COMPLIANCE (SAR EVALUATION)

                                           Date of Test: Dec 10 and 20. 2004

                                              ~Netgear Incorporated                                                  l’
    Applicant:                                  4500 Great America Parkway Santa Clara,                              |
                                                CA95054 U.S.A
    Model Number / Trade Name:                  WGILIU/NETGEAR
|                                                                                                                    |
    Device Category:                            PORTABLE DEVICES
    Exposure Category:                          GENERAL POPULATION/UNCONTROLLED EXPOSURE

    Test Sample is as         Production unit
     Modulation type:        802.11a
                             Orthogonal Frequency Division
                             Multiplexing (OFDM)                                               I
                             802.11b
                             Direct Sequence Spread
                             Spectrum(DSSS)                                                        o
                             $02.11g
                             Orthogonal Frequency Division
                             Multiplexing (OFDM)
    Ts Frequency:            802.11a:   5180 ~ 5825 MHz
                                       2412 ~ 2462 MHz
                                     : 2412 ~ 2462 MHz
     Max. O/P Power:         802.11a: 16.37 dBm
     (Conducted/Peak)        802.112 Turbo: 16.12 dBm
                             802.11b: 18.79 dBm                                           |
                             802.11g: 19.36 dBm
                             802.11g Turbo: 18.75 dBm                                     |
     Max. SAR (1g):          802.11a: 0.517 We                                            i
                             802.11a Turbo: 0.304 W/ke
                             802.11b: 0.251 We
                             802.11g: 0.251 We
                              802.11g Turbo: 0.429 We
    Application Type:        Cortification
     FCC Rule Part(s):        15C
    Note: This Report is only applicable for 802. 1 tb/g.
    This wireless portable device has been shownto be capable of compliance for localized specific absorption rate
    (SAR) for uncontrolled environment/general population exposure limits specified in ANSIIEEE Std. C95.1—1992
    and had beentested in accordance with the measurement procedures specified in FCC OET 65 Supplement C
    (released on 6/29/2001 see Test Report).
    1 attest to the accuracyof data. All measurements reported herein were performed by me or were made under my
    supervision and are correct to the best of my knowl           and belief. 1 assume full responsibility for the
    completeness of these measurements and vouch for the qua     ations of all personstaking them.

Approved by:                                                         Reviewed by:


                                                                          1      $                 &
                                                                                                        omm
Harris W. Lai                                                        Devin Chang
Executive Vice President                                             Section Manager
Compliance Certification Services Inc                                Compliance Certification Services Inc.

                                                            Page 3                                             Rev. 00


                 Compliance Certification Services Inc.
                 Report No: 41129003-SF          FCC ID: PY3WG111U       Date of Issue: Dec. 22, 2004



2. EUT DESCRIPTION

Applicant:                              Netgear Incorporated
                                        4500 Great America Parkway Santa Clara,
                                        CA95054 U.S.A
Model Number / Trade Name:              WG111U / NETGEAR
Device Category:                        PORTABLE DEVICES
Exposure Category:                      GENERAL POPULATION/UNCONTROLLED EXPOSURE

Test Sample is a:     Production unit
Modulation type:       802.11a
                       Orthogonal Frequency Division
                       Multiplexing (OFDM)
                       802.11b
                       Direct Sequence Spread
                       Spectrum(DSSS)
                       802.11g
                       Orthogonal Frequency Division
                       Multiplexing (OFDM)
Tx Frequency:          802.11a: 5180 ~ 5825 MHz
                       802.11b: 2412 ~ 2462 MHz
                       802.11g: 2412 ~ 2462 MHz
Max. O/P Power:        802.11a: 16.37 dBm
(Conducted/Peak)       802.11a Turbo: 16.12 dBm
                       802.11b: 18.79 dBm
                       802.11g: 19.36 dBm
                       802.11g Turbo: 18.75 dBm
Max. SAR (1g):         802.11a: 0.517 W/kg
                       802.11a Turbo: 0.304 W/kg
                       802.11b: 0.251 W/kg
                       802.11g: 0.251 W/kg
                       802.11g Turbo: 0.429 W/kg
Application Type:     Certification
FCC Rule Part(s):     15C
Antennas:              PIFA Ant.




                                                Page 4                                        Rev. 00


               Compliance Certification Services Inc.
               Report No: 41129003-SF            FCC ID: PY3WG111U             Date of Issue: Dec. 22, 2004



3. REQUIREMENTS FOR COMPLIANCE TESTING DEFINED BY THE FCC
  The US Federal Communications Commission has released the report and order “Guidelines for
  Evaluating the Environmental Effects of RF Radiation", ET Docket No. 93-62 in August 1996 [1].
  The order requires routine SAR evaluation prior to equipment authorization of portable transmitter
  devices, including portable telephones. For consumer products, the applicable limit is 1.6 mW/g for
  an uncontrolled environment and 8.0 mW/g for an occupational/controlled environment as
  recommended by the ANSI/IEEE standard C95.1-1992 [6]. According to the Supplement C of OET
  Bulletin 65 “Evaluating Compliance with FCC Guide-lines for Human Exposure to Radio frequency
  Electromagnetic Fields", released on Jun 29, 2001 by the FCC, the device should be evaluated at
  maximum output power (radiated from the antenna) under “worst-case” conditions for normal or
  intended use, incorporating normal antenna operating positions, device peak performance frequencies
  and positions for maximum RF energy coupling.

4. DOSIMETRIC ASSESSMENT SYSTEM
  These measurements were performed with the automated near-field scanning system DASY4 from
  Schmid & Partner Engineering AG (SPEAG). The system is based on a high precision robot
  (working range greater than 0.9 m) which positions the probes with a positional repeatability of better
  than ± 0.02 mm. Special E- and H-field probes have been developed for measurements close to
  material discontinuity, the sensors of which are directly loaded with a Schottky diode and connected
  via highly resistive lines to the data acquisition unit. The SAR measurements were conducted with
  the dosimetric probe ET3DV6-SN: 1763 and EX3DV3-SN: 3519 (manufactured by SPEAG),
  designed in the classical triangular configuration and optimized for dosimetric evaluation. The probe
  has been calibrated according to the procedure with accuracy of better than ±10%. The spherical
  isotropy was evaluated with the procedure and found to be better than ±0.25 dB. The phantom used
  was the SAM Twin Phantom as described in FCC supplement C, IEEE P1528 and EN50361.




                                                Page 5                                              Rev. 00


              Compliance Certification Services Inc.
              Report No: 41129003-SF              FCC ID: PY3WG111U               Date of Issue: Dec. 22, 2004



4.1 MEASUREMENT SYSTEM DIAGRAM




     The DASY4 system for performing compliance tests consists of the following items:
     • A standard high precision 6-axis robot (St¨aubli RX family) with controller, teach pendant and
         software. An arm extension for accommodating the data acquisition electronics (DAE).
     • A dosimetric probe, i.e., an isotropic E-field probe optimized and calibrated for usage in tissue
         simulating liquid. The probe is equipped with an optical surface detector system.
     • A data acquisition electronics (DAE) which performs the signal amplification, signal multiplexing,
         AD-conversion, offset measurements, mechanical surface detection, collision detection, etc. The unit
         is battery powered with standard or rechargeable batteries. The signal is optically transmitted to the
         EOC.
     • The Electro-optical converter (EOC) performs the conversion between optical and electrical of the
         signals for the digital communication to the DAE and for the analog signal from the optical surface
         detection. The EOC is connected to the measurement server.
     • The function of the measurement server is to perform the time critical tasks such as signal filtering,
         control of the robot operation and fast movement interrupts.
     • A probe alignment unit which improves the (absolute) accuracy of the probe positioning.
     • A computer operating Windows 2000 or Windows XP.
     • DASY4 software.
     • Remote control with teach pendant and additional circuitry for robot safety such as warning lamps,
         etc.
     • The SAM twin phantom enabling testing left-hand and right-hand usage.
     • The device holder for handheld mobile phones.
     • Tissue simulating liquid mixed according to the given recipes.
     • Validation dipole kits allowing validating the proper functioning of the system.




                                                  Page 6                                                Rev. 00


                   Compliance Certification Services Inc.
                   Report No: 41129003-SF                 FCC ID: PY3WG111U                     Date of Issue: Dec. 22, 2004



4.2 SYSTEM COMPONENTS

  DASY4 Measurement Server


                                         The DASY4 measurement server is based on a PC/104 CPU board with a
                                         166MHz low-power Pentium, 32MB chip disk and 64MB RAM. The
                                         necessary circuits for communication with either the DAE3 electronic box
                                         as well as the 16-bit AD-converter system for optical detection and digital
                                         I/O interface are contained on the DASY4 I/O-board, which is directly
                                         connected to the PC/104 bus of the CPU board.
                                         The measurement server performs all real-time data evaluation for field
                                         measurements and surface detection, controls robot movements and handles
                                         safety operation.
  The PC-operating system cannot interfere with these time critical processes. All connections are supervised by
  a watchdog, and disconnection of any of the cables to the measurement server will automatically disarm the
  robot and disable all program-controlled robot movements. Furthermore, the measurement server is equipped
  with two expansion slots which are reserved for future applications. Please note that the expansion slots do not
  have a standardized pinout and therefore only the expansion cards provided by SPEAG can be inserted.
  Expansion cards from any other supplier could seriously damage the measurement server. Calibration: No
  calibration required.

  Data Acquisition Electronics (DAE)
  The data acquisition electronics (DAE3) consists of a highly sensitive
  electrometer grade preamplifier with auto-zeroing, a channel and
  gain-switching multiplexer, a fast 16 bit AD converter and a
  command decoder and control logic unit. Transmission to the
  measurement server is accomplished through an optical downlink for
  data and status information as well as an optical uplink for commands
  and the clock. The mechanical probe mounting device includes two
  different sensor systems for frontal and sideways probe contacts.
  They are used for mechanical surface detection and probe collision
  detection. The input impedance of the DAE3 box is 200MOhm; the
  inputs are symmetrical and floating. Common mode rejection is
  above 80 dB.

  EX3DV3 Isotropic E-Field Probe for Dosimetric Measurements
   Construction:   Symmetrical design with triangular core
                   Built-in optical fiber for surface detection system (EX3DV3 only)
                   Built-in shielding against static charges
                   PEEK enclosure material (resistant to organic solvents, e.g., glycolether)
   Calibration:    Basic Broad Band Calibration in air: 10-3000 MHz.
                   Conversion Factors (CF) for HSL 900 and HSL 1800
                   CF-Calibration for other liquids and frequencies upon request.
   Frequency:      10 MHz to 6 GHz; Linearity: ± 0.2 dB (30 MHz to 3 GHz)
   Directivity:    ± 0.3 dB in HSL (rotation around probe axis)
                   ± 0.5 dB in HSL (rotation normal to probe axis)
   Dynamic Range: 8 µW/g to > 100 mW/g; Linearity: ± 0.2 dB                                         E-Field probe
   Optical Surface
   Detection:      ± 0.2 mm repeatability in air and clear liquids over
                   diffuse reflecting surfaces (EX3DV3 only)              Interior of probe
   Dimensions:     Overall length: 337 mm (Tip: 20 mm)
                   Tip diameter: 10 mm (Body: 12 mm)
                   Distance from probe tip to dipole centers: 1 mm
   Application:    General dosimetric measurements up to 6 GHz
                   Compliance tests of mobile phones
                   Fast automatic scanning in arbitrary phantoms
                   (EX3DV3)


                                                         Page 7                                                      Rev. 00


                Compliance Certification Services Inc.
                Report No: 41129003-SF                 FCC ID: PY3WG111U                     Date of Issue: Dec. 22, 2004




ET3DV6 Isotropic E-Field Probe for Dosimetric Measurements
Construction:   Symmetrical design with triangular core
                Built-in optical fiber for surface detection system (ET3DV6 only)
                Built-in shielding against static charges
                PEEK enclosure material (resistant to organic solvents, e.g., glycolether)
Calibration:    Basic Broad Band Calibration in air: 10-2500 MHz.
                Conversion Factors (CF) for HSL 900 and HSL 1800
                CF-Calibration for other liquids and frequencies upon request.
Frequency:      10 MHz to 3 GHz; Linearity: ± 0.2 dB (30 MHz to 3 GHz)
Directivity:    ± 0.2 dB in HSL (rotation around probe axis)
                ± 0.4 dB in HSL (rotation normal to probe axis)
Dynamic Range: 2 µW/g to > 100 mW/g; Linearity: ± 0.2 dB
Optical Surface
Detection:      ± 0.2 mm repeatability in air and clear liquids over
                diffuse reflecting surfaces (ET3DV6 only)
Dimensions:     Overall length: 330 mm (Tip: 16 mm)
                Tip diameter: 6.8 mm (Body: 12 mm)
                Distance from probe tip to dipole centers: 2.7 mm
Application:    General dosimetric measurements up to 3 GHz             Interior of probe           E-Field probe
                Compliance tests of mobile phones
                Fast automatic scanning in arbitrary phantoms
                (ET3DV6)



SAM Phantom (V4.0)
Construction:    The shell corresponds to the specifications of the
                 Specific Anthropomorphic Mannequin (SAM)
                 phantom defined in IEEE 1528-200X, CENELEC
                 50361 and IEC 62209. It enables the dosimetric
                 evaluation of left and right hand phone usage as
                 well as body mounted usage at the flat phantom
                 region. A cover prevents evaporation of the
                 liquid. Reference markings on the phantom allow
                 the complete setup of all predefined phantom
                 positions and measurement grids by manually
                 teaching three points with the robot.
Shell Thickness: 2 ±0.2 mm
Filling Volume: Approx. 25 liters
Dimensions:      Height: 810mm; Length: 1000mm; Width:
                 500mm

Device Holder for SAM Twin Phantom
Construction:    In combination with the Twin SAM Phantom V4.0 or Twin SAM, the
                 Mounting Device (made from POM) enables the rotation of the mounted
                 transmitter in spherical coordinates, whereby the rotation point is the ear
                 opening. The devices can be easily and accurately positioned according to IEC,
                 IEEE, CENELEC, FCC or other specifications. The device holder can be
                 locked at different phantom locations (left head, right head, and flat phantom).




                                                      Page 8                                                        Rev. 00


                Compliance Certification Services Inc.
                Report No: 41129003-SF                 FCC ID: PY3WG111U               Date of Issue: Dec. 22, 2004




System Validation Kits
Construction:      Symmetrical dipole with l/4 balun Enables measurement of feedpoint
                   impedance with NWA Matched for use near flat phantoms filled with brain
                   simulating solutions Includes distance holder and tripod adaptor.
Frequency:         450, 900, 1800, 2450, 5800 MHz
Return loss:       > 20 dB at specified validation position
Power capability: > 100 W (f < 1GHz); > 40 W (f > 1GHz)
Dimensions:        450V2: dipole length: 270 mm; overall height: 330 mm
                   D900V2: dipole length: 149 mm; overall height: 330 mm
                   D1800V2: dipole length: 72 mm; overall height: 300 mm
                   D2450V2: dipole length: 51.5 mm; overall height: 300 mm
                   D5GHzV2: dipole length: 25.5 mm; overall height: 290 mm




                                                       Page 9                                               Rev. 00


                    Compliance Certification Services Inc.
                    Report No: 41129003-SF                                   FCC ID: PY3WG111U                 Date of Issue: Dec. 22, 2004



5. EVALUATION PROCEDURES

DATA EVALUATION
The DASY4 post processing software (SEMCAD) automatically executes the following procedures to calculate the
field units from the microvolt readings at the probe connector. The parameters used in the evaluation are stored in
the configuration modules of the software:
              Probe parameters:      - Sensitivity                  Normi, ai0, ai1, ai2
                                     - Conversion factor            ConvFi
                                     - Diode compression point      dcpi
              Device parameters:     - Frequency                    f
                                     - Crest factor                 cf
              Media parameters:      - Conductivity                 σ
                                     - Density                      ρ
These parameters must be set correctly in the software. They can be found in the component documents or be
imported into the software from the configuration files issued for the DASY components. In the direct measuring
mode of the multi-meter option, the parameters of the actual system setup are used. In the scan visualization and
export modes, the parameters stored in the corresponding document files are used.
The first step of the evaluation is a linearization of the filtered input signal to account for the compression
characteristics of the detector diode. The compensation depends on the input signal, the diode type and the DC-
transmission factor from the diode to the evaluation electronics. If the exciting field is pulsed, the crest factor of the
signal must be known to correctly compensate for peak power. The formula for each channel can be given as:
                                          2        cf
                    V =U +U
                       i      i           i
                                              ⋅
                                                  dcp i

            with    Vi        = Compensated signal of channel i                             (i = x, y, z)
                    Ui        = Input signal of channel i                                   (i = x, y, z)
                    cf        = Crest factor of exciting field                              (DASY parameter)
                    dcpi      = Diode compression point                                     (DASY parameter)

From the compensated input signals the primary field data for each channel can be evaluated:
            E-field probes:                        V
                              E       =                           i
                                  i
                                              Norm • ConvF    i


                                                                                             2

            H-field probes:                                            a +a f +a f
                                                                      i10   i11       i12

                                                   H      i
                                                              =   Vi ⋅
                                                                            f
            with    Vi    = Compensated signal of channel i                                 (i = x, y, z)
                    Normi = Sensor sensitivity of channel i                                 (i = x, y, z)
                            µV/(V/m)2 for E0field Probes
                    ConvF = Sensitivity enhancement in solution
                    aij   = Sensor sensitivity factors for H-field probes
                    f     = Carrier frequency (GHz)
                    Ei    = Electric field strength of channel i in V/m
                    Hi    = Magnetic field strength of channel i in A/m




                                                                            Page 10                                                 Rev. 00


                    Compliance Certification Services Inc.
                    Report No: 41129003-SF                                         FCC ID: PY3WG111U   Date of Issue: Dec. 22, 2004




The RSS value of the field components gives the total field strength (Hermitian magnitude):
                                     2             2        2
                    E   tot
                              =    E +E +E
                                     x             y        z


The primary field data are used to calculate the derived field units.

                                         2             σ
                    SAR = E                    ⋅
                                         tot
                                                   ρ   ⋅1000

            with    SAR           = local specific absorption rate in mW/g
                    Etot          = total field strength in V/m
                    σ             = conductivity in [mho/m] or [Siemens/m]
                    ρ             = equivalent tissue density in g/cm3
Note that the density is normally set to 1 (or 1.06), to account for actual brain density rather than the density of the
simulation liquid.
The power flow density is calculated assuming the excitation field as a free space field.
                                     2
                                   E                   or       P
                                                                              2
                                                                          = H tot ⋅ 37.7
                    P         =      tot
                                                                    pwe
                        pwe
                                  3770
            with    Ppwe = Equivalent power density of a plane wave in mW/cm2
                    Etot    = total electric field strength in V/m
         Htot      = total magnetic field strength in A/m




                                                                                  Page 11                                   Rev. 00


                   Compliance Certification Services Inc.
                   Report No: 41129003-SF               FCC ID: PY3WG111U                Date of Issue: Dec. 22, 2004



SAR MEASUREMENT PROCEDURES
The procedure for assessing the peak spatial-average SAR value consists of the following steps:
•   Power Reference Measurement
    The reference and drift jobs are useful jobs for monitoring the power drift of the device under test in the batch
    process. Both jobs measure the field at a specified reference position, at a selectable distance from the phantom
    surface. The reference position can be either the selected section’s grid reference point or a user point in this
    section. The reference job projects the selected point onto the phantom surface, orients the probe
    perpendicularly to the surface, and approaches the surface using the selected detection method.
•   Area Scan
    The area scan is used as a fast scan in two dimensions to find the area of high field values, before doing a finer
    measurement around the hot spot. The sophisticated interpolation routines implemented in DASY4 software can
    find the maximum locations even in relatively coarse grids. The scan area is defined by an editable grid. This
    grid is anchored at the grid reference point of the selected section in the phantom. When the area scan’s
    property sheet is brought-up, grid was at to 15 mm by 15 mm and can be edited by a user.
•   Zoom Scan
    Zoom scans are used to assess the peak spatial SAR values within a cubic averaging volume containing 1 g and
    10 g of simulated tissue. The default zoom scan measures 5x5x7(for 2.45GHz) and 8x8x8(for 5GHz)points
    within a cube whose base faces are centered around the maximum found in a preceding area scan job within the
    same procedure. If the preceding Area Scan job indicates more then one maximum, the number of Zoom Scans
    has to be enlarged accordingly (The default number inserted is 1).
•   Power Drift measurement
    The drift job measures the field at the same location as the most recent reference job within the same procedure,
    and with the same settings. The drift measurement gives the field difference in dB from the reading conducted
    within the last reference measurement. Several drift measurements are possible for one reference measurement.
    This allows a user to monitor the power drift of the device under test within a batch process. In the properties
    of the Drift job, the user can specify a limit for the drift and have DASY4 software stop the measurements if
    this limit is exceeded.
•   Z-Scan
    The Z Scan job measures points along a vertical straight line. The line runs along the Z-axis of a one-
    dimensional grid. A user can anchor the grid to the current probe location. As with any other grids, the local Z-
    axis of the anchor location establishes the Z-axis of the grid.




                                                       Page 12                                                Rev. 00


              Compliance Certification Services Inc.
              Report No: 41129003-SF               FCC ID: PY3WG111U               Date of Issue: Dec. 22, 2004



SPATIAL PEAK SAR EVALUATION
The procedure for spatial peak SAR evaluation has been implemented according to the IEEE1529 standard. It
can be conducted for 1 g and 10 g.
The DASY4 system allows evaluations that combine measured data and robot positions, such as:
   • maximum search
   • extrapolation
   • boundary correction
   • peak search for averaged SAR
During a maximum search, global and local maximum searches are automatically performed in 2-D after each
Area Scan measurement with at least 6 measurement points. It is based on the evaluation of the local SAR
gradient calculated by the Quadratic Shepard’s method. The algorithm will find the global maximum and all
local maxima within -2 dB of the global maxima for all SAR distributions.
Extrapolation
Extrapolation routines are used to obtain SAR values between the lowest measurement points and the inner
phantom surface. The extrapolation distance is determined by the surface detection distance and the probe
sensor offset. Several measurements at different distances are necessary for the extrapolation.
Extrapolation routines require at least 10 measurement points in 3-D space. They are used in the Cube Scan to
obtain SAR values between the lowest measurement points and the inner phantom surface. The routine uses the
modified Quadratic Shepard’s method for extrapolation. For a grid using 5x5x7(for 2.45GHz) and 8x8x8(for
5GHz)measurement points with 5mm resolution amounting to 343 measurement points, the uncertainty of the
extrapolation routines is less than 1% for 1 g and 10 g cubes.
Boundary effect
For measurements in the immediate vicinity of a phantom surface, the field coupling effects between the probe
and the boundary influence the probe characteristics. Boundary effect errors of different dosimetric probe types
have been analyzed by measurements and using a numerical probe model. As expected, both methods showed
an enhanced sensitivity in the immediate vicinity of the boundary. The effect strongly depends on the probe
dimensions and disappears with increasing distance from the boundary. The sensitivity can be approximately
given as:




Since the decay of the boundary effect dominates for small probes (a<<λ), the cos-term can be omitted. Factors
Sb (parameter Alpha in the DASY4 software) and a (parameter Delta in the DASY4 software) are assessed
during probe calibration and used for numerical compensation of the boundary effect. Several simulations and
measurements have confirmed that the compensation is valid for different field and boundary configurations.
This simple compensation procedure can largely reduce the probe uncertainty near boundaries. It works well as
long as:
   • the boundary curvature is small
   • the probe axis is angled less than 30_ to the boundary normal
   • the distance between probe and boundary is larger than 25% of the probe diameter
   • the probe is symmetric (all sensors have the same offset from the probe tip)
Since all of these requirements are fulfilled in a DASY4 system, the correction of the probe boundary effect in
the vicinity of the phantom surface is performed in a fully automated manner via the measurement data
extraction during postprocessing.




                                                  Page 13                                                Rev. 00


                    Compliance Certification Services Inc.
                    Report No: 41129003-SF            FCC ID: PY3WG111U                   Date of Issue: Dec. 22, 2004



6. MEASUREMENT UNCERTAINTY
                            UNCERTAINTY BUDGE ACCORDING TO IEEE P1528

                                Uncertainty Probability                                     Standard
     Error Description           Value ±% distribution
                                                                Divisor       C1 1g       unc.(1g) ±%
                                                                                                      V1 or Veff

Measurement System
Probe calibration                        ±4.8         normal              1           1            ±4.8            ∞
                                                                                  1/2
Axial isotropy of probe                  ±4.6     rectangular        √3 (1-Cp)                     ±1.9            ∞
Sph. Isotropy of probe                   ±9.7     rectangular        √3       (Cp)1/2              ±3.9            ∞
Probe linearity                          ±4.5     rectangular        √3               1            ±2.7            ∞
Detection Limit                          ±0.9     rectangular        √3               1            ±0.6            ∞
Boundary effects                         ±8.5     rectangular        √3               1            ±4.8            ∞
Readoutelectronics                       ±1.0         normal              1           1            ±1.0            ∞
Response time                            ±0.9     rectangular        √3               1            ±0.5            ∞
Integration time                         ±1.2     rectangular        √3               1            ±0.8            ∞
Mech Constrains of robot                 ±0.5     rectangular        √3               1            ±0.2            ∞
Probe positioning                        ±2.7     rectangular        √3               1            ±1.7            ∞
Extrap. And integration                  ±4.0     rectangular        √3               1            ±2.3            ∞
RF ambient conditiona                   ±0.54     rectangular        √3               1           ±0.43            ∞
Test Sample Related
Device positioning                       ±2.2         normal              1           1           ±2.23            11
Device holder uncertainty                    ±5       normal              1           1            ±5.0             7
Power drift                                  ±5   rectangular        √3               1            ±2.9            ∞
Phantom and Set up
Phantom uncertainty                          ±4   rectangular        √3               1            ±2.3            ∞
Liquid conductivity                          ±5   rectangular        √3          0.6               ±1.7            ∞
Liquid conductivity                          ±5   rectangular        √3          0.6           ±3.5/1.7            ∞
Liquid permittivity                          ±5   rectangular        √3          0.6               ±1.7            ∞
Liquid permittivity                          ±5   rectangular        √3          0.6               ±1.7            ∞

Combined Standard
                                                                                          ±12.14/11.76
Uncertainty
Coverage Factor for 95%                                 kp=2
Expanded Standard
                                                                                          ±24.29/23.51
Uncertainty
    Table: Worst-case uncertainty for DASY4 assessed according to IEEE P1528.
    The budge is valid for the frequency range 300 MHz to 6G Hz and represents a worst-case analysis.




                                                    Page 14                                                    Rev. 00


                Compliance Certification Services Inc.
                Report No: 41129003-SF                          FCC ID: PY3WG111U             Date of Issue: Dec. 22, 2004



7. EXPOSURE LIMIT
  (A). Limits for Occupational/Controlled Exposure (W/kg)
      Whole-Body         Partial-Body           Hands, Wrists, Feet and Ankles
      0.4                8.0                    2.0


  (B). Limits for General Population/Uncontrolled Exposure (W/kg)
      Whole-Body         Partial-Body           Hands, Wrists, Feet and Ankles
      0.08               1.6                    4.0
      NOTE:     Whole-Body SAR is averaged over the entire body, partial-body SAR is averaged over any
                1 gram of tissue defined as a tissue volume in the shape of a cube. SAR for hands, wrists,
                feet and ankles is averaged over any 10 grams of tissue defined as a tissue volume in the
                shape of a cube.
      Population/Uncontrolled Environments:
      are defined as locations where there is the exposure of individuals who have no knowledge or
      control of their exposure.
      Occupational/Controlled Environments:
      are defined as locations where there is exposure that may be incurred by people who are aware of
      the potential for exposure, (i.e. as a result of employment or occupation).


                                            NOTE
                         GENERAL POPULATION/UNCONTROLLED EXPOSURE
                                     PARTIAL BODY LIMIT
                                           1.6 W/kg


8. TYPICAL COMPOSITION OF INGREDIENTS FOR LIQUID TISSUE PHANTOMS
  The following tissue formulations are provided for reference only as some of the parameters have not been
  thoroughly verified. The composition of ingredients may be modified accordingly to achieve the desired target
  tissue parameters required for routine SAR evaluation.
       Ingredients                                                  Frequency (MHz)
     (% by weight)                450                    835               915             1900             2450
      Tissue Type         Head          Body     Head          Body  Head      Body  Head      Body    Head     Body
          Water           38.56         51.16    41.45         52.4  41.05      56.0 54.9       40.4   62.7      73.2
       Salt (NaCl)         3.95          1.49     1.45          1.4   1.35      0.76  0.18      0.5     0.5      0.04
          Sugar           56.32         46.78     56.0         45.0   56.5     41.76  0.0       58.0    0.0      0.0
          HEC              0.98          0.52     1.0           1.0   1.0       1.21  0.0       1.0     0.0      0.0
       Bactericide         0.19          0.05     0.1           0.1   0.1       0.27  0.0       0.1     0.0      0.0
      Triton X-100         0.0           0.0      0.0           0.0   0.0       0.0   0.0       0.0    36.8      0.0
         DGBE              0.0           0.0      0.0           0.0   0.0       0.0  44.92      0.0     0.0      26.7
   Dielectric Constant    43.42         58.0     42.54         56.1   42.0      56.8 39.9       54.0   39.8      52.5
   Conductivity (S/m)      0.85          0.83     0.91         0.95   1.0       1.07 1.42       1.45   1.88      1.78

  Salt: 99+% Pure Sodium Chloride            Sugar: 98+% Pure Sucrose
                             +
  Water: De-ionized, 16 MΩ resistivity       HEC: Hydroxyethyl Cellulose
  DGBE: 99+% Di(ethylene glycol) butyl ether, [2-(2-butoxyethoxy)ethanol]
  Triton X-100 (ultra pure): Polyethylene glycol mono [4-(1, 1, 3, 3-tetramethylbutyl)phenyl]ether




                                                               Page 15                                             Rev. 00


                       Compliance Certification Services Inc.
                       Report No: 41129003-SF                       FCC ID: PY3WG111U                  Date of Issue: Dec. 22, 2004



9. MEASUREMENT RESULTS

9.1 SYSTEM PERFORMANCE CHECK
  The system performance check is performed prior to any usage of the system in order to guarantee reproducible
  results. The system performance check verifies that the system operates within its specifications. The system
  performance check results are tabulated below. And also the corresponding SAR plot is attached as well in the
  SAR plots files.
  SYSTEM PERFORMANCE CHECK MEASUREMENT CONDITIONS
  •      The measurements were performed in the flat section of the SAM twin phantom filled with Body
         simulating liquid of the following parameters.
  •      The DASY4 system with an E-fileld probe ET3DV6 SN: 1763 and EX3DV3-SN: 3519 was used for the
         measurements.
  •      The dipole was mounted on the small tripod so that the dipole feed point was positioned below the center
         marking of the flat phantom section and the dipole was oriented parallel to the body axis (the long side of
         the phantom). The standard measuring distance was 10 mm (above 1 GHz) from dipole center to the
         simulating liquid surface.
  •      The coarse grid with a grid spacing of 10mm was aligned with the dipole.
  •      Special 5x5x7 fine cube was chosen for cube integration (dx=dy= 7.5 mm, dz= 3 mm)and 8x8x8 fine cube
         was chosen for cube integration (dx=dy= 4.3 mm, dz= 3 mm).
  •      Distance between probe sensors and phantom surface was set to 3.0 mm.
  •      The dipole input power (forward power) was 250 mW±3%.
  •      The results are normalized to 1 W input power.
  Reference SAR values
  The reference SAR values were using measurement results indicated in the dipole calibration document (see
  table below)

      Frequency                                          Local SAR at Surface                 Local SAR at Surface
                1g SAR                  10g SAR
        (MHz)                                             (Above Feed Point)             (y = 2cm offset from feed point)

           900              10.3            6.57                     16.4                                  5.4

         1800               38.2            20.3                     69.5                                  6.8

   2450(Body)               53.2            24.3                    104.2                                  7.7




  SYSTEM PERFORMANCE CHECK RESULTS
  Dipole: D2450V2 SN: 728
  Date: Dec. 10, 2004
  Ambient condition: Temperature 25.5°C; Relative humidity: 56%
                B od y S im u latin g Liq u id
                                                          P aram eters        T a rget   M easu red   D eviation [% ]   L im ited [% ]
       f(M H z)        T em p . [°C ]    D ep th [cm ]
                                                          P erm itivity:      5 2 .7 0    5 0 .3 0        -4 .5 5            ± 5
       2 4 5 0 .0 0        2 4 .5 0         1 5 .0 0     C on d u c tivity:   1 .9 5       1 .9 3         -1 .0 3            ± 5
                                                            1g SAR :          5 3 .6 0    5 1 .6 0        -3 .7 3            ± 5




                                                                  Page 16                                                       Rev. 00


                  Compliance Certification Services Inc.
                  Report No: 41129003-SF                       FCC ID: PY3WG111U                  Date of Issue: Dec. 22, 2004




Dipole: D5GMHz SN:1004
Date: Dec. 20, 2004
Ambient condition: Temperature 25.1°C; Relative humidity: 54%
           B od y S im u latin g Liq u id
                                                     P aram eters        T a rget   M easu red   D eviation [% ]   L im ited [% ]
   f(M H z)       T em p . [°C ]    D ep th [cm ]
                                                     P erm itivity:      4 9 .0 2    4 6 .7 7        -4 .5 9            ± 5
  5 2 0 0 .0 0        2 3 .9 0         1 5 .0 0     C on d u c tivity:   5 .2 9       5 .5 0         3 .9 7             ± 5
                                                       1g SAR :          8 4 .0 0    8 2 .0 0        -2 .3 8            ± 5



Dipole: D5GMHz SN:1004
Date: Dec. 20, 2004
Ambient condition: Temperature 25.1°C; Relative humidity: 54%
           B od y S im u latin g Liq u id
                                                     P aram eters        T a rget   M easu red   D eviation [% ]   L im ited [% ]
   f(M H z)       T em p . [°C ]    D ep th [cm ]
                                                     P erm itivity:      4 8 .2 0    4 5 .8 2        -4 .9 4            ± 5
  5 8 0 0 .0 0        2 3 .9 0         1 5 .0 0     C on d u c tivity:   6 .0 0       6 .2 8         4 .6 7             ± 5
                                                       1g SAR :          8 0 .0 0    8 0 .8 0        1 .0 0             ± 5




                                                             Page 17                                                       Rev. 00


                  Compliance Certification Services Inc.
                  Report No: 41129003-SF               FCC ID: PY3WG111U                Date of Issue: Dec. 22, 2004



9.2 TEST LIQUID CONFIRMATION
   SIMULATING LIQUIDS PARAMETER CHECK
   The simulating liquids should be checked at the beginning of a series of SAR measurements to determine of the
   dielectric parameters are within the tolerances of the specified target values
   The relative permittivity and conductivity of the tissue material should be within ± 5% of the values given in the
   table below. 5% may not be easily achieved at certain frequencies. Under such circumstances, 10% tolerance
   may be used until more precise tissue recipes are available
   IEEE SCC-34/SC-2 P1528 RECOMMENDED TISSUE DIELECTRIC PARAMETERS
   The head tissue dielectric parameters recommended by the IEEE SCC-34/SC-2 in P1528 have been
   incorporated in the following table. These head parameters are derived from planar layer models simulating the
   highest expected SAR for the dielectric properties and tissue thickness variations in a human head. Other head
   and body tissue parameters that have not been specified in P1528 are derived from the tissue dielectric
   parameters computed from the 4-Cole-Cole equations and extrapolated according to the head parameters
   specified in P1528
     Target Frequency                         Head                                     Body
            (MHz)                     εr               σ (S/m)                 εr                 σ (S/m)
              150                    52.3                0.76                 61.9                 0.80
              300                    45.3                0.87                 58.2                 0.92
              450                    43.5                0.87                 56.7                 0.94
              835                    41.5                0.90                 55.2                 0.97
              900                    41.5                0.97                 55.0                 1.05
              915                    41.5                0.98                 55.0                 1.06
             1450                    40.5                1.20                 54.0                 1.30
             1610                    40.3                1.29                 53.8                 1.40
          1800-2000                  40.0                1.40                 53.3                 1.52
             2450                    39.2                1.80                 52.7                 1.95
             3000                    38.5                2.40                 52.0                 2.73
             5800                    45.3                5.27                 48.2                 6.00


   SIMULATING LIQUIDS PARAMETER CHECK RESULTS

   Ambient condition: Temperature: 25.5°C; Relative humidity: 56%                     Date: Dec. 10, 2004
            Body Simulating Liquid
                                               Parameters       Target   Measured     Deviation[%] Limited[%]
      f (MHz)       Temp. [°C]   Depth (cm)
                                               Permitivity:     52.70      50.30          -4.55             ±5
      2450.00         24.50        15.00
                                              Conductivity:     1.95        1.93          -1.03             ±5




                                                      Page 18                                                    Rev. 00


             Compliance Certification Services Inc.
             Report No: 41129003-SF            FCC ID: PY3WG111U             Date of Issue: Dec. 22, 2004




Ambient condition: Temperature: 25.1°C; Relative humidity: 54%              Date: Dec. 20, 2004
        Body Simulating Liquid
                                        Parameters      Target   Measured   Deviation[%] Limited[%]
   f (MHz)   Temp. [°C]   Depth (cm)
                                       Permitivity:     49.02     46.77        -4.59          ±5
  5200.00       23.90       15.00
                                       Conductivity:    5.29      5.50         3.97           ±5



Ambient condition: Temperature: 25.1°C; Relative humidity: 54%              Date: Dec. 20, 2004
        Body Simulating Liquid
                                        Parameters      Target   Measured   Deviation[%] Limited[%]
   f (MHz)   Temp. [°C]   Depth (cm)
                                       Permitivity:     48.20     45.82        -4.94          ±5
  5800.00       23.90       15.00
                                       Conductivity:    6.00      6.28         4.67           ±5




                                              Page 19                                              Rev. 00


                 Compliance Certification Services Inc.
                 Report No: 41129003-SF             FCC ID: PY3WG111U            Date of Issue: Dec. 22, 2004



9.3 EUT TUNE-UP PROCEDURES
The following procedure had been used to prepare the EUT for the SAR test.
o   The client supplied a special driver to program the EUT, allowing it to continually transmit the
    specified maximum power and change the channel frequency.
o   The conducted power was measured at the high, middle and low channel frequency before and after
    the SAR measurement.
o    The output power(dBm) we measured before SAR test in different transition rate and channel



    IEEE802.11a:
                            Rate
                                               6M                    54M
    CH(Frequency)
            36(5180 MHz)                      15.96                  16.02
            52(5260 MHz)                      16.16                  16.22
            64(5320 MHz)                      16.32                  16.37
           149(5745 MHz)                      16.16                  16.21
           157(5785 MHz)                      16.14                  16.19
           165(5825 MHz)                      16.14                  16.20

    IEEE802.11b:
                            Rate
                                               1M                    11M
    CH(Frequency)
             1(2412 MHz)                      18.46                  18.52
             6(2437 MHz)                      18.50                  18.56
            11(2462 MHz)                      18.73                  18.79

    IEEE802.11g:
                            Rate
                                               6M                    54M
    CH(Frequency)
             1(2412 MHz)                      19.32                  19.25
             6(2437 MHz)                      19.36                  19.30
            11(2462 MHz)                      19.33                  19.27

    TURBO MODE:
                            Rate
                                              12M                   108M
    CH(Frequency)
             6(2437 MHz)                      18.75                  18.70
            50(5250 MHz)                      15.80                  15.85
           160(5800 MHz)                      16.06                  16.12




                                                  Page 20                                              Rev. 00


                    Compliance Certification Services Inc.
                    Report No: 41129003-SF                    FCC ID: PY3WG111U       Date of Issue: Dec. 22, 2004



9.4 SAR MEASUREMENTS RESULTS

Test Configuration-1




802.11b (DSSS): Duty Cycle =100 %, Crest Factor: 1,Rate=1M                        Depth of liquid: 15.0 cm
                                                                 *Conducted       Liquid
  Sep.                                    Frequency                                           SAR        Limit
            Antenna        Channel                              Power_dBm         Temp
 [mm]                                       [MHz]                                            (W/kg)     (W/kg)
                                                              Before     After     [°C]
  0       PIFA       6        2437        18.50       18.48                        24.5      0.251       1.6
802.11b (DSSS): Duty Cycle =100 %, Crest Factor: 1,Rate=11M                       Depth of liquid: 15.0 cm
                                                                 *Conducted       Liquid
  Sep.                                    Frequency                                           SAR        Limit
            Antenna        Channel                              Power_dBm         Temp
 [mm]                                       [MHz]                                            (W/kg)     (W/kg)
                                                              Before     After     [°C]
   0          PIFA             6             2437              18.56     18.53     24.5      0.244        1.6
 Notes:
     1.   *: Peak power.
     2.   Bottom face in parallel with flat phantom.
     3.   See attachment for the result presentation in plot format.




                                                            Page 21                                        Rev. 00


                    Compliance Certification Services Inc.
                    Report No: 41129003-SF                    FCC ID: PY3WG111U       Date of Issue: Dec. 22, 2004




Test Configuration-2




                                                                       15mm




802.11b (DSSS): Duty Cycle = 100 %, Crest Factor: 1,Rate=1M                         Depth of liquid: 15.0 cm
                                                                 *Conducted       Liquid
  Sep.                                    Frequency             Power_dBm                     SAR        Limit
            Antenna        Channel                                                Temp
 [mm]                                       [MHz]                                            (W/kg)     (W/kg)
                                                              Before     After     [°C]
  15      PIFA       6        2437        18.49       18.47                       24.5    0.0178       1.6
802.11b (DSSS): Duty Cycle = 100 %, Crest Factor: 1,Rate=11M                       Depth of liquid: 15.0 cm
                                                                 *Conducted       Liquid
  Sep.                                    Frequency             Power_dBm                     SAR        Limit
            Antenna        Channel                                                Temp
 [mm]                                       [MHz]                                            (W/kg)     (W/kg)
                                                              Before     After     [°C]
   15         PIFA             6             2437              18.55     18.53    24.5      0.0215        1.6
 Notes:
     1.   *: Peak power.
     2.   Host device perpendicular to flat phantom.
     3.   See attachment for the result presentation in plot format.




                                                            Page 22                                        Rev. 00


                    Compliance Certification Services Inc.
                    Report No: 41129003-SF                    FCC ID: PY3WG111U       Date of Issue: Dec. 22, 2004



Test Configuration-1




802.11g (OFDM): Duty Cycle =100 %, Crest Factor: 1,Rate=6M                        Depth of liquid: 15.0 cm
                                                                 *Conducted       Liquid
  Sep.                                    Frequency                                           SAR        Limit
            Antenna        Channel                              Power_dBm         Temp
 [mm]                                       [MHz]                                            (W/kg)     (W/kg)
                                                              Before     After     [°C]
  0       PIFA      6        2437        19.36       19.34                        24.5      0.251      1.6
802.11g (OFDM): Duty Cycle =100 %, Crest Factor: 1,Rate=54M                       Depth of liquid: 15.0 cm
                                                                 *Conducted       Liquid
  Sep.                                    Frequency                                           SAR        Limit
            Antenna        Channel                              Power_dBm         Temp
 [mm]                                       [MHz]                                            (W/kg)     (W/kg)
                                                              Before     After     [°C]
   0          PIFA             6             2437              19.29     19.27    24.5       0.195        1.6
 Notes:
     1.   *: Peak power.
     2.   Bottom face in parallel with flat phantom.
     3.   See attachment for the result presentation in plot format.




                                                            Page 23                                        Rev. 00


                    Compliance Certification Services Inc.
                    Report No: 41129003-SF                    FCC ID: PY3WG111U       Date of Issue: Dec. 22, 2004



Test Configuration-2




                                                                       15mm




802.11g (OFDM): Duty Cycle = 100 %, Crest Factor: 1,Rate=6M                         Depth of liquid: 15.0 cm
                                                                 *Conducted       Liquid
  Sep.                                    Frequency             Power_dBm                     SAR        Limit
            Antenna        Channel                                                Temp
 [mm]                                       [MHz]                                            (W/kg)     (W/kg)
                                                              Before     After     [°C]
  15      PIFA      6        2437        19.35       19.33   24.5   0.0180       1.6
802.11g (OFDM): Duty Cycle = 100 %, Crest Factor: 1,Rate=54M Depth of liquid: 15.0 cm
                                                                 *Conducted       Liquid
  Sep.                                    Frequency             Power_dBm                     SAR        Limit
            Antenna        Channel                                                Temp
 [mm]                                       [MHz]                                            (W/kg)     (W/kg)
                                                              Before     After     [°C]
   15         PIFA             6             2437              19.30     19.28    24.5      0.0151        1.6
 Notes:
     1.   *: Peak power.
     2.   Host device perpendicular to flat phantom.
     3.   See attachment for the result presentation in plot format.




                                                            Page 24                                        Rev. 00


                    Compliance Certification Services Inc.
                    Report No: 41129003-SF                    FCC ID: PY3WG111U       Date of Issue: Dec. 22, 2004



Test Configuration-1




802.11g (OFDM): Duty Cycle =100 %, Crest Factor: 1,Rate=12M                       Depth of liquid: 15.0 cm
                                                                 *Conducted       Liquid
  Sep.                                    Frequency                                           SAR        Limit
            Antenna        Channel                              Power_dBm         Temp
 [mm]                                       [MHz]                                            (W/kg)     (W/kg)
                                                              Before     After     [°C]
  0       PIFA      6        2437        18.75       18.72   24.5    0.429       1.6
802.11g (OFDM): Duty Cycle =100 %, Crest Factor: 1,Rate=108M Depth of liquid: 15.0 cm
                                                                 *Conducted       Liquid
  Sep.                                    Frequency                                           SAR        Limit
            Antenna        Channel                              Power_dBm         Temp
 [mm]                                       [MHz]                                            (W/kg)     (W/kg)
                                                              Before     After     [°C]
   0          PIFA             6             2437              18.70     18.67    24.5       0.403        1.6
 Notes:
     1.   *: Peak power.
     2.   Bottom face in parallel with flat phantom.
     3.   See attachment for the result presentation in plot format.




                                                            Page 25                                        Rev. 00


                   Compliance Certification Services Inc.
                   Report No: 41129003-SF                FCC ID: PY3WG111U          Date of Issue: Dec. 22, 2004



Test Configuration-1




802.11a (OFDM): Duty Cycle =100 %, Crest Factor: 1, Rate=54M. Depth of liquid: 15.0 cm
                                                              *Conducted        Liquid
   Sep.                                 Frequency             Power_dBm                     SAR         Limit
             Antenna      Channel                                               Temp
  [mm]                                    [MHz]                                            (W/kg)      (W/kg)
                                                          Before        After    [°C]
 0mm      PIFA     52        5260         16.22      16.19    23.9      0.517       1.6
802.11a (OFDM): Duty Cycle =100 %, Crest Factor: 1, Rate=54M. Depth of liquid: 15.0 cm
                                                              *Conducted        Liquid
   Sep.                                 Frequency             Power_dBm                     SAR         Limit
             Antenna      Channel                                               Temp
  [mm]                                    [MHz]                                            (W/kg)      (W/kg)
                                                          Before        After    [°C]
 0mm          PIFA          157           5785            16.19         16.17   23.9       0.241        1.6
 Notes: 1. *: Peak power.
        2. Bottom face in parallel with flat phantom.
        3. See attachment for the result presentation in plot format.




                                                        Page 26                                          Rev. 00


                   Compliance Certification Services Inc.
                   Report No: 41129003-SF                FCC ID: PY3WG111U          Date of Issue: Dec. 22, 2004



Test Configuration-2




                                                                    15mm




802.11a (OFDM): Duty Cycle =100 %, Crest Factor: 1, Rate=54M. Depth of liquid: 15.0 cm
                                                              *Conducted        Liquid
   Sep.                                 Frequency             Power_dBm                     SAR         Limit
             Antenna      Channel                                               Temp
  [mm]                                    [MHz]                                            (W/kg)      (W/kg)
                                                          Before        After    [°C]
15mm      PIFA     52        5260         16.21      16.19    23.9       0.252      1.6
802.11a (OFDM): Duty Cycle =100 %, Crest Factor: 1, Rate=54M. Depth of liquid: 15.0 cm
                                                              *Conducted        Liquid
   Sep.                                 Frequency             Power_dBm                     SAR         Limit
             Antenna      Channel                                               Temp
  [mm]                                    [MHz]                                            (W/kg)      (W/kg)
                                                          Before        After    [°C]
 15mm         PIFA          157           5785            16.18         16.16   23.9       0.078        1.6
 Notes: 1. *: Peak power.
        2. Host device perpendicular to flat phantom.
        3. See attachment for the result presentation in plot format.




                                                        Page 27                                          Rev. 00


                   Compliance Certification Services Inc.
                   Report No: 41129003-SF                FCC ID: PY3WG111U          Date of Issue: Dec. 22, 2004




Test Configuration-1




802.11a (OFDM): Duty Cycle =100 %, Crest Factor: 1, Rate=108M. Depth of liquid: 15.0 cm
                                                             *Conducted         Liquid
  Sep.                                 Frequency            Power_dBm                       SAR        Limit
            Antenna      Channel                                                Temp
 [mm]                                    [MHz]                                             (W/kg)     (W/kg)
                                                          Before     After       [°C]
 0mm      PIFA     50        5250         15.85      15.83    23.9      0.197       1.6
802.11a (OFDM): Duty Cycle =100 %, Crest Factor: 1, Rate=108M. Depth of liquid: 15.0 cm
                                                             *Conducted         Liquid
  Sep.                                 Frequency            Power_dBm                       SAR        Limit
            Antenna      Channel                                                Temp
 [mm]                                    [MHz]                                             (W/kg)     (W/kg)
                                                          Before     After       [°C]
 0mm          PIFA          160           5800            16.12         16.10   23.9       0.304        1.6
 Notes: 1. *: Peak power.
        2. Bottom face in parallel with flat phantom.
        3. See attachment for the result presentation in plot format.




                                                        Page 28                                          Rev. 00


           Compliance Certification Services Inc.
           Report No: 41129003-SF       FCC ID: PY3WG111U   Date of Issue: Dec. 22, 2004



10. EUT PHOTOS




                      PIFA Ant.




                                       Page 29                                   Rev. 00


                   Compliance Certification Services Inc.
                   Report No: 41129003-SF              FCC ID: PY3WG111U            Date of Issue: Dec. 22, 2004



11. EQUIPMENT LIST & CALIBRATION STATUS
        Name of Equipment              Manufacturer           Type/Model    Serial Number    Calibration Due
S-Parameter Network Analyzer         Agilent              E8358A           US40260243       05/24/05
Electronic Probe kit                 Hewlett Packard      85070D           N/A              N/A
Power Meter                          Boonton              4531             13061            07/12/05
Power Sensor                         Boonton              56218            2240             07/12/05
Thermometer                          Amarell              4046             25060            10/02/14
Thermometer                          Amarell              4046             25058            12/03/14
Universal Radio Communication
                                     Rohde & Schwarz      CMU 200          1100.0008.02     N/A
Tester
Signal Generator                     Agilent              83630B           3844A01022       01/14/05
Amplifier                            Mini-Circuit         ZHL-1724HLN N/A                   N/A
DC Power generator                   ABM                  8301HD           N/A              N/A
Data Acquisition Electronics (DAE)   SPEAG                DAE3             427              03/15/05
Data Acquisition Electronics (DAE)   SPEAG                DAE3             558              08/24/05
Dosimetric E-Field Probe             SPEAG                ET3DV6           1763             03/23/05
Dosimetric E-Field Probe             SPEAG                EX3DV3           3519             03/19/05
900 MHz System Validation Dipole     SPEAG                D900V2           179              05/12/06
1800 MHz System Validation Dipole    SPEAG                D1800V2          2d062            03/17/06
2450 MHz System Validation Dipole    SPEAG                D2450V2          728              03/22/06
D5Gz System Validation Dipole        SPEAG                D5GHz            1004             10/05/05
Probe Alignment Unit                 SPEAG                LB (V2)          348              N/A
Robot                                Staubli              RX90B L          F02/5T69A1/A/01 N/A
SAM Twin Phantom V4.0                SPEAG                N/A              N/A              N/A
Devices Holder                       SPEAG                N/A              N/A              N/A
Head 835 MHz                         CCS                  H835A            N/A              N/A
Muscle 835 MHz                       CCS                  M835A            N/A              N/A
Head 900 MHz                         CCS                  H900A            N/A              N/A
Muscle 900 MHz                       CCS                  M900A            N/A              N/A
Head 1800 MHz                        CCS                  H1800A           N/A              N/A
Muscle 1800 MHz                      CCS                  M1800A           N/A              N/A
Head 1900 MHz                        CCS                  H1900A           N/A              N/A
Muscle 1900 MHz                      CCS                  M1900A           N/A              N/A
Head 2450 MHz                        CCS                  H2450A           N/A              N/A
Muscle 2450 MHz                      CCS                  M2450A           N/A              N/A
Muscle 5800 MHz                      CCS                  M5800A           N/A              N/A




                                                    Page 30                                              Rev. 00


                 Compliance Certification Services Inc.
                 Report No: 41129003-SF              FCC ID: PY3WG111U              Date of Issue: Dec. 22, 2004



12. FACILITIES
   All measurement facilities used to collect the measurement data are located at
        No. 81-1, Lane 210, Bade Rd. 2, Luchu Hsiang, Taoyuan Hsien, Taiwan, R.O.C.
        No. 11, Wu-Kung 6 Rd, Wu-Ku Hsiang, Wu-Ku Industrial District, Taipei Hsien, (248)
        Taiwan.
        No. 199, Chunghsen Road, Hsintien City, Taipei Hsien, Taiwan, R.O.C.

13. REFERENCES
  [1]   Federal Communications Commission, \Report and order: Guidelines for evaluating the environ-mental
        effects of radiofrequency radiation", Tech. Rep. FCC 96-326, FCC, Washington, D.C. 20554, 1996.
  [2]   David L. Means Kwok Chan, Robert F. Cleveland, \Evaluating compliance with FCC guidelines for
        human exposure to radiofrequency electromagnetic fields", Tech. Rep., Federal Communication
        Commision, O_ce of Engineering & Technology, Washington, DC, 1997.
  [3]   Thomas Schmid, Oliver Egger, and Niels Kuster, \Automated E-_eld scanning system for dosimetric
        assessments", IEEE Transactions on Microwave Theory and Techniques, vol. 44, pp. 105{113, Jan. 1996.
  [4]   Niels Kuster, Ralph K.astle, and Thomas Schmid, \Dosimetric evaluation of mobile communications
        equipment with known precision", IEICE Transactions on Communications, vol. E80-B, no. 5, pp.
        645{652, May 1997.
  [5]   CENELEC, \Considerations for evaluating of human exposure to electromagnetic fields (EMFs) from
        mobile telecommunication equipment (MTE) in the frequency range 30MHz - 6GHz", Tech. Rep.,
        CENELEC, European Committee for Electrotechnical Standardization, Brussels, 1997.
  [6]   ANSI, ANSI/IEEE C95.1-1992: IEEE Standard for Safety Levels with Respect to Human Exposure to
        Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz, The Institute of Electrical and Electronics
        Engineers, Inc., New York, NY 10017, 1992.
  [7]   Katja Pokovic, Thomas Schmid, and Niels Kuster, \Robust setup for precise calibration of E-_eld probes
        in tissue simulating liquids at mobile communications frequencies", in ICECOM _ 97, Dubrovnik,
        October 15{17, 1997, pp. 120{124.
  [8]   Katja Pokovic, Thomas Schmid, and Niels Kuster, \E-_eld probe with improved isotropy in brain
        simulating liquids", in Proceedings of the ELMAR, Zadar, Croatia, 23{25 June, 1996, pp. 172{175.
  [9]   Volker Hombach, Klaus Meier, Michael Burkhardt, Eberhard K. uhn, and Niels Kuster, \The dependence
        of EM energy absorption upon human head modeling at 900 MHz", IEEE Transactions onMicrowave
        Theory and Techniques, vol. 44, no. 10, pp. 1865{1873, Oct. 1996.
  [10] Klaus Meier, Ralf Kastle, Volker Hombach, Roger Tay, and Niels Kuster, \The dependence of EM energy
       absorption upon human head modeling at 1800 MHz", IEEE Transactions on Microwave Theory and
       Techniques, Oct. 1997, in press.
  [11] W. Gander, Computermathematik, Birkhaeuser, Basel, 1992.
  [12] W. H. Press, S. A. Teukolsky,W. T. Vetterling, and B. P. Flannery, Numerical Recepies in C, The Art of
       Scientific Computing, Second Edition, Cambridge University Press, 1992..Dosimetric Evaluation of
       Sample device, month 1998 9
  [13] NIS81 NAMAS, \The treatment of uncertainity in EMC measurement", Tech. Rep., NAMAS Executive,
       National Physical Laboratory, Teddington, Middlesex, England, 1994.
   [14] Barry N. Taylor and Christ E. Kuyatt, \Guidelines for evaluating and expressing the uncertainty of NIST
        measurement results", Tech. Rep., National Institute of Standards and Technology, 1994. Dosimetric
        Evaluation of Sample device, month 1998 10




                                                    Page 31                                              Rev. 00


              Compliance Certification Services Inc.
              Report No: 41129003-SF        FCC ID: PY3WG111U   Date of Issue: Dec. 22, 2004



14. ATTACHMENTS

Exhibit                                         Content
   1      System Performance Check Plots
   2      SAR Test Plots




                                       END OF REPORT