RF EXPOSURE EVALUATION

 According to FCC 1.1310 : The criteria listed in the following table shall be used to evaluate the
 environment impact of human exposure to radio frequency (RF) radiation as specified in
 1.1307(b)
 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)

  Frequency Range       Electric Field    Magnetic Field     Power Density
                                                                                 Average Time
        (MHz)          Strength (V/m)     Strength (A/m)        (mW/cm2)
                        (A) Limits for Occupational / Control Exposures
   300-1,500                  --                 --               F/300                 6
   1,500-100,000              --                 --                  5                  6
                    (B) Limits for General Population / Uncontrol Exposures
   300-1,500                  --                 --               F/1500                6
   1,500-100,000              --                 --                  1                 30



 Friis Formula

       Friis transmission formula : Pd = (Pout*G)/(4*pi*r2)
       Where
       Pd = power density in mW/cm2
       Pout = output power to antenna in mW
       G = gain of antenna in linear scale
       Pi = 3.1416
       R = distance between observation point and center of the radiator in cm
       Pd id the limit of MPE, 1 mW/cm2. If we know the maximum gain of the antenna and
       the total power input to the antenna, through the calculation, we will know the distance
       where the MPE limit is reached.


 EUT Operating Condition

       A software provided by client enabled the EUT to transmit and receive data at lowest,
       middle and highest channel individually.


                                                            FCC ID :PY3WAG302
              Compliance Certification Services Inc.        Report No.:EC05-01-048FRFa
                                                            Page    2    of    2


Test Result of RF Exposure Evaluation

  Test Item       : RF Exposure Evaluation Data
  Test Mode       : Normal Operation


  Antenna Gain

       Antenna Gain:The maximum Gain measured in fully anechoic chamber is 5dBi
                         linear scale.


   Output Power into Antenna & RF Exposure Evaluation Distance
      For normal 802.11a mode
                      Channel      Output                    Power Density
                                                                                   LIMITS
        Channel      Frequency Power to Antenna                 at 20cm
                                                                                  (mW/cm2)
                       (MHz)        (dBm)                      (mW/cm2)
              1            5180             16.17               0.026045               1
              4            5240             16.39               0.027399               1
              5            5260             16.50               0.028102               1
              8            5320             18.32               0.042730               1

      For Super A mode
                     Channel      Output                     Power Density
                                                                                   LIMITS
        Channel     Frequency Power to Antenna                  at 20cm
                                                                                  (mW/cm2)
                       (MHz)       (dBm)                       (mW/cm2)
           Low             5210             16.54               0.028362               1
         Middle            5250             16.15               0.025926               1
          High             5290             18.05               0.040154               1

      Note : The power density Pd (4th column) at a distance of 20cm calculated from the friis
             transmission formula is far below the limit of 1 mW/cm2 . The EUT is classified as
             mobile product. So, RF exposure limit warning or SAR test are not required.