Human Exposure

FCC ID: PY326200346

RF Exposure Info

Download: PDF
FCCID_3178321

 seorron cas.   RF Exposure Evaluation Report                                  Report No. : FA690707
                                                                                Project No: CB10510256




         RF Exposure Evaluation Report

       Equipment                   : Powerline WiFi 1000, Powerline WiFi Essentials
                                     Edition 1010
       Brand Name                  : NETGEAR
       Model No.                   : PLW1000v2, PLW1010v2
       FCC ID                      : PY326200346
       Standard                    : 47 CFR Part 2.1091
       Applicant                   : NETGEAR, Inc.
                                    350 East Plumeria Drive, San Jose, California 95134,
                                    USA


      The product sample received on Sep. 06, 2016 and completely tested on Oct. 11, 2016. We,
      SPORTON, would like to declare that the tested sample has been evaluated in accordance
      with 47 CFR Part 2.1091, and pass the limit.
      Without written approval of SPORTON INTERNATIONAL INC., the test report shall not be
      reproduced except in full.

                                                                         ww                                   .
                                                                       mam/‘s
                                                                 §                  g
                                                                                    [




                n                     \/éN                               on                  Testing Laboratory
       Sam Chen                                                         *Lf OX                    1190
       SPORTON INTERNATIONAL INC.




SPORTON INTERNATIONAL INC.                                         Page No.             : 1 of6
TEL : 886—3—327—3456                                               Report Version       : Rev. 01
FAX : 886—3—327—0973                                               Issued Date          : Oct. 20, 2016
FCC ID: PY326200346


                  RF Exposure Evaluation Report                                                                           Report No. : FA690707




                                                TABLE OF CONTENTS
1       GENERAL DESCRIPTION ....................................................................................................................4
1.1     EUT General Information .......................................................................................................................4
1.2     Table for Multiple Listing ........................................................................................................................4
1.3     Testing Location .....................................................................................................................................4
2       MAXIMUM PERMISSIBLE EXPOSURE ...............................................................................................5
2.1     Limit of Maximum Permissible Exposure ...............................................................................................5
2.2     MPE Calculation Method........................................................................................................................5
2.3     Calculated Result and Limit....................................................................................................................6




SPORTON INTERNATIONAL INC.                                                                                Page No.                    : 2 of 6
TEL : 886-3-327-3456                                                                                      Report Version              : Rev. 01
FAX : 886-3-327-0973                                                                                      Issued Date                 : Oct. 20, 2016
FCC ID: PY326200346


                RF Exposure Evaluation Report                                     Report No. : FA690707



                                   REVISION HISTORY
   REPORT NO.          VERSION              DESCRIPTION                              ISSUED DATE

     FA690707            Rev. 01          Initial issue of report                     Oct. 20, 2016




SPORTON INTERNATIONAL INC.                                          Page No.            : 3 of 6
TEL : 886-3-327-3456                                                Report Version      : Rev. 01
FAX : 886-3-327-0973                                                Issued Date         : Oct. 20, 2016
FCC ID: PY326200346


                 RF Exposure Evaluation Report                                              Report No. : FA690707



1         General Description
1.1       EUT General Information
                                             RF General Information
                         Frequency          Operating
    Evaluation
                           Range            Frequency                        Modulation Type
      Mode
                           (MHz)              (MHz)
                                                           802.11b: DSSS (DBPSK, DQPSK, CCK)
 2.4GHz WLAN           2400-2483.5       2412-2462
                                                           802.11g/n: OFDM (BPSK, QPSK, 16QAM, 64QAM)
                                                           802.11a/n: OFDM (BPSK, QPSK, 16QAM, 64QAM)
                       5150-5250         5180-5240
 5GHz WLAN                                                 802.11ac: OFDM (BPSK, QPSK, 16QAM, 64QAM,
                       5725-5850         5745-5825
                                                                      256QAM)

1.2       Table for Multiple Listing
The model names in the following table are all refer to the identical product.
             Equipment Name                       Model Name                        Description
            Powerline WiFi 1000                   PLW1000v2         There are identical PCBA, only different
 Powerline WiFi Essentials Edition 1010           PLW1010v2         skin of housing for different marketing
From the above models, model: PLW1000v2 was selected as representative model for the test and its data
was recorded in this report.

1.3       Testing Location
                                                  Testing Location
      HWA YA           ADD   :   No. 52, Hwa Ya 1st Rd., Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C.
                       TEL   :   886-3-327-3456         FAX   :    886-3-327-0973
      JHUBEI           ADD   :   No.8, Lane 724, Bo-ai St., Jhubei City, HsinChu County 302, Taiwan, R.O.C.
                       TEL   :   886-3-656-9065         FAX    :   886-3-656-9085




SPORTON INTERNATIONAL INC.                                                    Page No.            : 4 of 6
TEL : 886-3-327-3456                                                          Report Version      : Rev. 01
FAX : 886-3-327-0973                                                          Issued Date         : Oct. 20, 2016
FCC ID: PY326200346


                  RF Exposure Evaluation Report                                            Report No. : FA690707



2         Maximum Permissible Exposure
2.1       Limit of Maximum Permissible Exposure
(A) Limits for Occupational / Controlled Exposure
                                                                                                Averaging Time
  Frequency Range         Electric Field        Magnetic Field        Power Density (S)
                                                                                                 |E|²,|H|² or S
       (MHz)            Strength (E) (V/m)    Strength (H) (A/m)         (mW/ cm²)
                                                                                                  (minutes)
        0.3-3.0                 614                  1.63                     (100)*                        6
         3.0-30              1842 / f               4.89 / f                 (900 / f)*                     6
        30-300                  61.4                0.163                       1.0                         6
       300-1500                                                               F/300                         6
    1500-100,000                                                                 5                          6
(B) Limits for General Population / Uncontrolled Exposure
                                                                                                Averaging Time
 Frequency Range          Electric Field       Magnetic Field         Power Density (S)
                                                                                                 |E|²,|H|² or S
      (MHz)             Strength (E) (V/m)   Strength (H) (A/m)          (mW/ cm²)
                                                                                                  (minutes)
       0.3-1.34                 614                  1.63                     (100)*                    30
        1.34-30               824/f                 2.19/f                   (180/f)*                   30
        30-300                 27.5                 0.073                      0.2                      30
       300-1500                                                              F/1500                     30
    1500-100,000                                                               1.0                      30
Note: f = frequency in MHz ; *Plane-wave equivalent power density
Note: f = frequency in MHz ; *Plane-wave equivalent power density

2.2       MPE Calculation Method
The MPE was calculated at 20 cm to show compliance with the power density limit.
The following formula was used to calculate the Power Density:


               30  P  G                                                    E2
E (V/m) =                                Power Density:        Pd (W/m²) =
                   d                                                         377
E = Electric field (V/m)
P = RF output power (W)
G = EUT Antenna numeric gain (numeric)
d = Separation distance between radiator and human body (m)
The formula can be changed to

Pd =
        30  P  G
         377  d 2


SPORTON INTERNATIONAL INC.                                                   Page No.            : 5 of 6
TEL : 886-3-327-3456                                                         Report Version      : Rev. 01
FAX : 886-3-327-0973                                                         Issued Date         : Oct. 20, 2016
FCC ID: PY326200346


                RF Exposure Evaluation Report                                    Report No. : FA690707


2.3       Calculated Result and Limit
Exposure Environment: General Population / Uncontrolled Exposure
                              DG     Power    EIRP    EIRP     Distance      S        S Limit         Ratio
            Mode                                                                2            2
                             (dBi)   (dBm)   (dBm)     (W)       (cm)     (mW/cm )   (mW/cm )       (S/Limit)
          2.4G;G1D           2.00    22.85   24.85   0.30549     20       0.06078        1          0.06078
          5.8G;D1D           2.00    25.88   27.88   0.61376     20        0.1221        1           0.1221
                                                                                     Sum Ratio      0.18288
                                                                                     Ratio Limit       1




SPORTON INTERNATIONAL INC.                                         Page No.             : 6 of 6
TEL : 886-3-327-3456                                               Report Version       : Rev. 01
FAX : 886-3-327-0973                                               Issued Date          : Oct. 20, 2016
FCC ID: PY326200346



Document Created: 2017-12-16 22:49:53
Document Modified: 2017-12-16 22:49:53

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC