RF Exposure Report

FCC ID: PY319200449

RF Exposure Info

Download: PDF
FCCID_4388255

                                                           RF Exposure Report

                       Report No.: SA190715C10

                            FCC ID: PY319200449

                       Test Model: RBR10

                 Received Date: Jul. 15, 2019

                         Test Date: Jul. 23 ~ Jul. 25, 2019

                     Issued Date: Jul. 26, 2019


                         Applicant: NETGEAR, INC.

                          Address: 350 East Plumeria Drive San Jose, CA 95134


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
                                 (R.O.C.)
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)
            FCC Registration / 788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.

Report No.: SA190715C10                                              Page No. 1 / 5                                             Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
3         Calculation Result of Maximum Conducted Power........................................................................... 5




Report No.: SA190715C10                                              Page No. 2 / 5                                              Report Format Version: 6.1.1


                                          Release Control Record

Issue No.             Description                                         Date Issued
SA190715C10           Original release.                                   Jul. 26, 2019




Report No.: SA190715C10                      Page No. 3 / 5        Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Orbi Router

              Brand: NETGEAR

        Test Model: RBR10

    Sample Status: Engineering sample

          Applicant: NETGEAR, INC.

          Test Date: Jul. 23 ~ Jul. 25, 2019

         Standards: FCC Part 2 (Section 2.1091)
                          KDB 447498 D01 General RF Exposure Guidance v06
                          IEEE C95.3-2002



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                              , Date:         Jul. 26, 2019
                             Pettie Chen / Senior Specialist




     Approved by :                                               , Date:         Jul. 26, 2019
                             Bruce Chen / Project Engineer




Report No.: SA190715C10                         Page No. 4 / 5                        Report Format Version: 6.1.1


2    RF Exposure
2.1 Limits for Maximum Permissible Exposure (MPE)
  Frequency Range      Electric Field   Magnetic Field               Power Density            Average Time
       (MHz)          Strength (V/m)    Strength (A/m)                 (mW/cm2)                 (minutes)
                             Limits For General Population / Uncontrolled Exposure

       300-1500                  …                       …                F/1500                    30

     1500-100,000                …                       …                 1.0                      30
F = Frequency in MHz

2.2 MPE Calculation Formula
Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
pi = 3.1416
r = distance between observation point and center of the radiator in cm

2.3 Classification
The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So,
this device is classified as Mobile Device.


3     Calculation Result of Maximum Conducted Power

                                                                                     Power
    Frequency                        Max Power    Antenna Gain                                     Limit
                      Mode                                     Distance (cm)        Density
    Band (MHz)                         (dBm)          (dBi)                                      (mW/cm2)
                                                                                   (mW/cm2)
    WLAN             CDD         27.63           4.49               20               0.324             1
  2412~2462     Beamforming     27.18            4.49               20               0.292             1
    WLAN             CDD         25.82           5.51               20               0.270             1
  5180~5240     Beamforming     25.69            5.51               20               0.262             1
    WLAN             CDD         26.16           6.50               20               0.367             1
  5745~5825     Beamforming     26.16            6.50               20               0.367             1
Note:
1. Directional Gain:
2412~2462MHz Max. Directional Gain = 10 log[(10G1 /10 + 10G2 /10 + … + 10GN /10)/NANT] = 4.49dBi
5180~5240MHz Max. Directional Gain = 10 log[(10G1 /10 + 10G2 /10 + … + 10GN /10)/NANT] = 5.51dBi
5745~5825MHz Max. Directional Gain = 10 log[(10G1 /10 + 10G2 /10 + … + 10GN /10)/NANT] = 6.50dBi

2. Determining compliance based on the results of the compliance measurement, not taking into account
   measurement instrumentation uncertainty.

Conclusion:
The formula of calculated the MPE is:
CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
CPD = Calculation power density
LPD = Limit of power density

WLAN 2.4G+5G = 0.324 / 1 + 0.367 / 1 = 0.691 < 1