                                                           RF Exposure Report

                       Report No.: SA190430E07 R1

                             FCC ID: PY319200443

                       Test Model: MC327

                   Series Model: MC327BL, MC327WL, MC327HW, MC327LW

                 Received Date: Apr. 30, 2019

                         Test Date: May 10 to Jun. 18, 2019

                     Issued Date: Jul. 17, 2019


                         Applicant: NETGEAR, Inc.

                           Address: 350 East Plumeria Drive, San Jose, CA 95134, USA



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
             Test Location (1): No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
                                (R.O.C.)
         FCC Registration /
       Designation Number: 198487 / TW2021
             Test Location (2): E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                                Taiwan R.O.C.
         FCC Registration /
       Designation Number: 723255 / TW2022




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.


Report No.: SA190430E07 R1                            Page No. 1 / 6                                                            Report Format Version: 6.1.1
Cancels and replaces the report no.: SA190430E07 dated Jun. 20, 2019


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits For Maximum Permissible Exposure (MPE)............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
    2.4      Calculation Result Of Maximum Conducted Power ............................................................................ 6




Report No.: SA190430E07 R1                            Page No. 2 / 6                                                             Report Format Version: 6.1.1
Cancels and replaces the report no.: SA190430E07 dated Jun. 20, 2019


                                                Release Control Record


 Issue No.               Description                                           Date Issued
 SA190430E07             Original release.                                     Jun. 20, 2019
 SA190430E07 R1          Addition of Model No. MC327.                          Jul. 17, 2019




Report No.: SA190430E07 R1                            Page No. 3 / 6     Report Format Version: 6.1.1
Cancels and replaces the report no.: SA190430E07 dated Jun. 20, 2019


1    Certificate of Conformity


             Product: Meural Canvas

               Brand: NETGEAR

         Test Model: MC327

       Series Model: MC327BL, MC327WL, MC327HW, MC327LW

     Sample Status: Engineering sample

           Applicant: NETGEAR, Inc.

           Test Date: May 10 to Jun. 18, 2019

          Standards: FCC Part 2 (Section 2.1091)

                          KDB 447498 D01 General RF Exposure Guidance v06




The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                                     , Date:          Jul. 17, 2019
                                    Annie Chang / Senior Specialist




     Approved by :                                                      , Date:          Jul. 17, 2019
                               Rex Lai / Associate Technical Manager




Report No.: SA190430E07 R1                            Page No. 4 / 6                  Report Format Version: 6.1.1
Cancels and replaces the report no.: SA190430E07 dated Jun. 20, 2019


2     RF Exposure

2.1     Limits For Maximum Permissible Exposure (MPE)

    Frequency Range          Electric Field          Magnetic Field    Power Density      Average Time
         (MHz)              Strength (V/m)           Strength (A/m)      (mW/cm2)           (minutes)
                             Limits For General Population / Uncontrolled Exposure
        0.3-1.34                  614                      1.63           (100)*                 30
                                                                                  2
        1.34-30                   824/f                   2.19/f         (180/f )*               30
        30-300                    27.5                    0.073             0.2                  30
       300-1500                    …                        …             f/1500                 30
      1500-100,000                 …                        …               1.0                  30

f = Frequency in MHz ; *Plane-wave equivalent power density



2.2     MPE Calculation Formula

Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm



2.3     Classification

The antenna of this product, under normal use condition, is at least 20cm away from the body of the user.
So, this device is classified as Mobile Device.




Report No.: SA190430E07 R1                            Page No. 5 / 6                   Report Format Version: 6.1.1
Cancels and replaces the report no.: SA190430E07 dated Jun. 20, 2019


2.4     Calculation Result Of Maximum Conducted Power

      Frequency
                       Max Power         Antenna Gain            Distance   Power Density            Limit
         Band
                         (dBm)               (dBi)                 (cm)       (mW/cm2)             (mW/cm2)
        (MHz)
      2412-2462           25.67                 2.7                    20      0.1367                   1

      5180-5240           23.82                3.77                    20      0.1142                   1

      5745-5825           23.62                3.81                    20      0.1101                   1

Note: Determining compliance based on the results of the compliance measurement, not taking into account
      measurement instrumentation uncertainty.

 --- END ---




Report No.: SA190430E07 R1                            Page No. 6 / 6                        Report Format Version: 6.1.1
Cancels and replaces the report no.: SA190430E07 dated Jun. 20, 2019