MPE Calcualtion

FCC ID: PY318400431

RF Exposure Info

Download: PDF
FCCID_4152928

                                                           RF Exposure Report

                       Report No.: SA181024C03A

                             FCC ID: PY318400431

                       Test Model: EX6250

                 Received Date: Oct. 24, 2018

                         Test Date: Nov. 07 ~ Dec. 11, 2018

                     Issued Date: Dec. 28, 2018


                         Applicant: NETGEAR, INC.

                           Address: 350 East Plumeria Drive San Jose, CA 95134


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
                                 (R.O.C.)
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)
         FCC Registration / 788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth ourfindings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to
us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such
notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your
unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the
uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.

Report No.: SA181024C03A                                              Page No. 1 / 6                                             Report Format Version: 6.1.1
Reference No.: 181024C04


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
3         Calculation Result of Maximum Conducted Power........................................................................... 6




Report No.: SA181024C03A                                             Page No. 2 / 6                                              Report Format Version: 6.1.1
Reference No.: 181024C04


                                         Release Control Record


Issue No.             Description                                        Date Issued
SA181024C03A          Original release                                   Dec. 28, 2018




Report No.: SA181024C03A                    Page No. 3 / 6        Report Format Version: 6.1.1
Reference No.: 181024C04


1    Certificate of Conformity


            Product: AC1750 WiFi Mesh Extender

              Brand: NETGEAR

        Test Model: EX6250

    Sample Status: Engineering sample

          Applicant: NETGEAR, INC.

          Test Date: Nov. 07 ~ Dec. 11, 2018

         Standards: FCC Part 2 (Section 2.1091)
                           KDB 447498 D01 General RF Exposure Guidance v06
                           IEEE C95.1-1992



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                               , Date:        Dec. 28, 2018
                              Celine Chou / Senior Specialist




     Approved by :                                                , Date:        Dec. 28, 2018
                              Bruce Chen / Project Engineer




Report No.: SA181024C03A                         Page No. 4 / 6                       Report Format Version: 6.1.1
Reference No.: 181024C04


2     RF Exposure
2.1 Limits for Maximum Permissible Exposure (MPE)
    Frequency Range         Electric Field     Magnetic Field       Power Density          Average Time
         (MHz)             Strength (V/m)      Strength (A/m)         (mW/cm2)               (minutes)
                            Limits For General Population / Uncontrolled Exposure

       300-1500                  …                    …                   F/1500                  30

     1500-100,000                …                    …                    1.0                    30
F = Frequency in MHz

2.2 MPE Calculation Formula
Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm

2.3 Classification
The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So,
this device is classified as Mobile Device.




Report No.: SA181024C03A                      Page No. 5 / 6                         Report Format Version: 6.1.1
Reference No.: 181024C04


3    Calculation Result of Maximum Conducted Power
Frequency Band        Max Power         Antenna Gain              Distance     Power Density              Limit
    (MHz)               (dBm)               (dBi)                   (cm)         (mW/cm2)               (mW/cm2)
                                                    CDD Mode

    2412-2462              24.88             6.07                   20             0.248                     1

    5180-5240              27.19             4.34                   20             0.283                     1

    5260-5320              23.50             4.15                   20             0.116                     1

    5500-5720              23.38             4.17                   20             0.113                     1

    5745-5825              28.14             4.80                   20             0.391                     1

                                               Beamforming Mode

    5180-5240              27.13             4.34                   20             0.279                     1

    5180-5240              23.50             4.15                   20             0.116                     1

    5260-5320              23.38             4.17                   20             0.113                     1

    5745-5825              27.95             4.80                   20             0.375                     1
Note:
2412~2462MHz Directional gain = 10 log[(10G1 /20 + 10G2 /20 + ... + 10GN /20)2/3]= 6.07dBi
5180~5240MHz Directional gain = 4.34dBi
5260~5320MHz Directional gain = 4.15dBi
5500~5700MHz Directional gain = 4.17dBi
5745~5825MHz Directional gain = 4.80dBi


Conclusion:
Both of the WLAN 2.4G & WLAN 5G can transmit simultaneously, the formula of calculated the MPE is:
CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
CPD = Calculation power density
LPD = Limit of power density


2.4G + 5G = 0.248 / 1 + 0.391 / 1 = 0.639

Therefore the maximum calculations of above situations are less than the “1” limit.



---END---