RF Exposure Report

FCC ID: PY316200349

RF Exposure Info

Download: PDF
FCCID_3849654

                                                           RF Exposure Report

                       Report No.: SA160630E01G

                            FCC ID: PY316200349

                       Test Model: VMC4030

                 Received Date: Sep. 28, 2017

                         Test Date: Nov. 30, 2017

                     Issued Date: Feb. 13, 2018


                         Applicant: NETGEAR, Inc.

                          Address: 350 East Plumeria Drive San Jose, CA 95134



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                   Hsin Chu Laboratory
                    Lab Address: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                                 Taiwan R.O.C.




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by any government agencies.
Report No.: SA160630E01G                                             Page No. 1 / 6                                             Report Format Version: 6.1.1
Reference No.: 170928E01


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity ...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
    2.4      Antenna Gain ...................................................................................................................................... 5
    2.5      Calculation Result of Maximum Conducted Power ............................................................................. 6




Report No.: SA160630E01G                                             Page No. 2 / 6                                              Report Format Version: 6.1.1
Reference No.: 170928E01


                                          Release Control Record


Issue No.             Description                                         Date Issued
SA160630E01G          Original release.                                   Feb. 13, 2018




Report No.: SA160630E01G                     Page No. 3 / 6        Report Format Version: 6.1.1
Reference No.: 170928E01


1    Certificate of Conformity


            Product: Arlo Pro

              Brand: NETGEAR

        Test Model: VMC4030

    Sample Status: ENGINEERING SAMPLE

          Applicant: NETGEAR, Inc.

          Test Date: Nov. 30, 2017

         Standards: FCC Part 2 (Section 2.1091)

                       KDB 447498 D01 General RF Exposure Guidance v06
                           IEEE C95.1-1992



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                              ,   Date:      Feb. 13, 2018
                                   Mary Ko / Specialist




     Approved by :                                               ,   Date:      Feb. 13, 2018
                                  May Chen / Manager




Report No.: SA160630E01G                        Page No. 4 / 6                       Report Format Version: 6.1.1
Reference No.: 170928E01


2      RF Exposure

2.1         Limits for Maximum Permissible Exposure (MPE)

    Frequency Range               Electric Field            Magnetic Field        Power Density           Average Time
                                                                                           2
         (MHz)                   Strength (V/m)             Strength (A/m)          (mW/cm )                (minutes)
                                  Limits For General Population / Uncontrolled Exposure
        0.3-1.34                      614                        1.63                   (100)*                   30
                                                                                               2
         1.34-30                     824/f                      2.19/f                 (180/f )*                 30
            30-300                    27.5                      0.073                    0.2                     30
        300-1500                       …                          …                     f/1500                   30
      1500-100,000                     …                          …                      1.0                     30

f = Frequency in MHz ; *Plane-wave equivalent power density



2.2         MPE Calculation Formula

                             2
Pd = (Pout*G) / (4*pi*r )
where
                                      2
Pd = power density in mW/cm
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm



2.3         Classification

      The antenna of this product, under normal use condition, is at least 20cm away from the body of the user.
      So, this device is classified as Mobile Device.




2.4         Antenna Gain

                                                                 Frequency
                                                   Antenna                                  Connector   Cable Loss    Cable Length
Antenna Set.         Brand          Model                          range     Antenna Type
                                                   Gain (dBi)                                 Type         (db)          (mm)
                                                                (GHz to GHz)
                                 902P00197N0         1.94        2.4~2.4835     PIFA               NA       NA             NA
        1         Master Wave
                                 902P00196N0         1.94        2.4~2.4835     PIFA               NA       NA             NA




Report No.: SA160630E01G                                    Page No. 5 / 6                              Report Format Version: 6.1.1
Reference No.: 170928E01


2.5     Calculation Result of Maximum Conducted Power


Frequency Band        Max Power         Antenna Gain           Distance   Power Density         Limit
                                                                                   2                  2
    (MHz)               (mW)                (dBi)                (cm)       (mW/cm )          (mW/cm )
      2412-2462            314.775          1.94                 20         0.09789                1




--- END ---


Conclusion:
The formula of calculated the MPE is:
CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
CPD = Calculation power density
LPD = Limit of power density


WLAN 2.4GHz + WLAN 5GHz = 0.468 + 0.453 = 0.921
Therefore the maximum calculations of above situations are less than the “1” limit.




Report No.: SA160630E01G                      Page No. 6 / 6                       Report Format Version: 6.1.1
Reference No.: 170928E01



Document Created: 2018-02-13 17:59:12
Document Modified: 2018-02-13 17:59:12

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC