RF Exp

FCC ID: PY313200235

RF Exposure Info

Download: PDF
FCCID_2117128

                   FCC RF Exposure Report
            FCC ID                 : PY313200235
            Equipment              : LG6100D Brooklyn Bridge LTE Router
            Model No.              : LG6100D
            Brand Name             : NETGEAR
            Applicant              : NETGEAR, Inc.
            Address                : 350 East Plumeria Drive, San Jose, California
                                     95134, USA
            Standard               : 47 CFR FCC Part 2.1091
            Received Date          : Oct. 11, 2013
            Tested Date            : Oct. 11 ~ Nov. 01, 2013


      We, International Certification Corp., would like to declare that the tested sample has been
      evaluated and in compliance with the requirement of the above standards. The test results
      contained in this report refer exclusively to the product. It may be duplicated completely for
      legal use with the approval of the applicant. It shall not be reproduced except in full without
      the written approval of our laboratory.



      Approved & Reviewed by:




      Gary Chang / Manager                            Ty: XXX




Report No.: FA3O2308                                                                  Page : 1 of 6
Report Version: Rev. 01


                                                   Table of Contents
1        MPE EVALUATION OF MOBILE DEVICES ......................................................................................... 4

1.1      LIMITS FOR GENERAL POPULATION/UNCONTROLLED EXPOSURE............................................. 4
1.2      MPE EVALUATION FORMULA ............................................................................................................. 4
1.3      MPE EVALUATION RESULTS .............................................................................................................. 5

2        TEST LABORATORY INFORMATION ................................................................................................. 6




Report No.: FA3O2308                                                                                                Page : 2 of 6
Report Version: Rev. 01


                                    Release Record
     Report No.           Version                   Description      Issued Date
     FA3O2308             Rev. 01   Initial issue                   Nov. 08, 2013




Report No.: FA3O2308                                              Page : 3 of 6
Report Version: Rev. 01


1         MPE EVALUATION OF MOBILE DEVICES
Human exposure to RF emissions from mobile devices (47 CFR §2.1091) may be evaluated based on the
MPE limits adopted by the FCC for electric and magnetic field strength and/or power density, as appropriate,
since exposures are assumed to occur at distances of 20 cm or more from persons.



1.1       LIMITS FOR GENERAL POPULATION/UNCONTROLLED EXPOSURE
                                                                  2
      Frequency Range (MHz)              Power Density (mW /cm )            Averaging Time (minutes)
               300~1500                           F/1500                                 30
             1500~100000                            1.0                                  30


1.2       MPE EVALUATION FORMULA
                               Pt
                 Pd =
                          4 * Pi * R 2
Where
                                  2
Pd=   Power density in mW/cm
Pt=   EIRP in Mw
Pi=   3.1416
R=    Measurement distance




Report No.: FA3O2308                                                                    Page : 4 of 6
Report Version: Rev. 01


C           Infernational
            Certification
            Corp.




1.3         MPE EVALUATION RESULTS


MPE Evaluation of Single Transmission

                             Maximum
  R:;thleu(ilrlfilz/)        P%‘\j;;fig‘;;)          Ante(r:irgai)Gain   Di(s:a;:l)ce        Po(vlvr:evrvzilzs)ity    Limit (mW/cm?)


    2412~2462                  26.26                     2.4                 20                  0.146                          1
    5180~5240                  16.57                     2.9                 20                  0.018                          1
    5745~5825                  23.76                      3                  20                  0.094                          1

MPE Evaluation of Simultaneous Transmission
The device contains a certified module (FCC ID: PY3N M7371), MPE of this module is as below table
                             Maximum                             :       &                                  .
  R';rr?gq:‘(el\rlllfi;)     P%‘\j;;fig‘;;)          Ante(r:irgai)Gam    Dl(s:a;:l)ce        Po(vlvr:evrvzilzs)fly     Limit (mW/cm?)


      814~824                  24.92                     7.9                 20                  0.381                    0.543
      824~849                  24.83                     7.9                 20                  0.373                    0.549
    1850~1910                  24.76                      8                  20                  0.376                          1
    2500~2690                  23.49                     9.5                 20                  0.396                          1



2.4, 5GHz and WWAN function can transmit at the same time, MPE evaluation is as below formula

PD1 / Limit1 + PD2 / Limit 2+ ... .. < 1, PD = Power density

Configuration1        =   2.4GHz   +   5GHz   +   WWAN   814~824 MHz = 0.941
Configuration2        =   2.4GHz   +   5GHz   +   WWAN   824~849 MHz = 0.919
Configuration3        =   2.4GHz   +   5GHz   +   WWAN   1850~1910 MHz =0.616         <1
Configuration4        =   2.4GHz   +   5GHz   +   WWAN   2500~2690 MHz = 0.636        <1

Conclusion
MPE evaluations of single and simultaneous transmission meet the requirement of standard.




Report No.: FA3O2308                                                                                            Page : 5 of 6
Report Version: Rev. 01


2         Test laboratory information
Established in 2012, ICC provides foremost EMC & RF Testing and advisory consultation services by our
skilled engineers and technicians. Our services employ a wide variety of advanced edge test equipment and
one of the widest certification extents in the business.


International Certification Corp, it is our definitive objective is to institute long term, trust-based associations
with our clients. The expectation we set up with our clients is based on outstanding service, practical expertise
and devotion to a certified value structure. Our passion is to grant our clients with best EMC / RF services by
oriented knowledgeable and accommodating staff.


Our Test sites are located at Linkou District and Kwei Shan Hsiang. Location map can be found on our
website http://www.icertifi.com.tw.


Linkou                                                        Kwei Shan
Tel: 886-3-271-8666                                           Tel: 886-3-271-8666
No. 30-2, Ding Fwu Tsuen, Lin Kou District, New Taipei        No. 3-1, Lane 6, Wen San 3rd St., Kwei Shan
City, Taiwan, R.O.C.                                          Hsiang, Tao Yuan Hsien 333, Taiwan, R.O.C.

If you have any suggestion, please feel free to contact us as below information

Tel: 886-3-271-8666
Fax: 886-3-318-0155
Email: ICC_Service@icertifi.com.tw



══END══




Report No.: FA3O2308                                                                          Page : 6 of 6
Report Version: Rev. 01



Document Created: 2019-11-08 18:51:27
Document Modified: 2019-11-08 18:51:27

© 2024 FCC.report