RF Exposure info.

FCC ID: PY312400216

RF Exposure Info

Download: PDF
FCCID_1894969

                                                 Report No.: FR310915




             Appendix B. Maximum Permissible Exposure




FCC ID: PY312400216                             Page No.   : B1 of B3


                                                                                                    Report No.: FR310915



1. Maximum Permissible Exposure
1.1. Applicable Standard

      Systems operating under the provisions of this section shall be operated in a manner that ensures that the
      public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure.
      In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a
      mobile device whereby a distance of 0.2 m normally can be maintained between the user and the
      device.
      (A) Limits for Occupational / Controlled Exposure
                                                                                                        Averaging Time
        Frequency Range               Electric Field     Magnetic Field         Power Density (S)
                                                                                                         |E|²,|H|² or S
              (MHz)                Strength (E) (V/m)   Strength (H) (A/m)         (mW/ cm²)
                                                                                                           (minutes)
              0.3-3.0                     614                 1.63                    (100)*                   6
              3.0-30                    1842 / f             4.89 / f                (900 / f)*                6
              30-300                     61.4                 0.163                     1.0                    6
            300-1500                                                                   F/300                   6
          1500-100,000                                                                     5                   6
      (B) Limits for General Population / Uncontrolled Exposure
                                                                                                        Averaging Time
        Frequency Range               Electric Field     Magnetic Field        Power Density (S)
                                                                                                         |E|²,|H|² or S
              (MHz)                Strength (E) (V/m)   Strength (H) (A/m)        (mW/ cm²)
                                                                                                           (minutes)
             0.3-1.34                    614                  1.63                    (100)*                  30
             1.34-30                     824/f                2.19/f                  (180/f)*                30
              30-300                     27.5                 0.073                     0.2                   30
            300-1500                                                                  F/1500                  30
          1500-100,000                                                                  1.0                   30
      Note: f = frequency in MHz ; *Plane-wave equivalent power density

1.2. MPE Calculation Method

      E (V/m) =
                      30  P  G                   Power Density:      Pd (W/m²) =
                                                                                     E2
                          d                                                          377
      E = Electric field (V/m)
      P = Average RF output power (W)
      G = EUT Antenna numeric gain (numeric)
      d = Separation distance between radiator and human body (m)
      The formula can be changed to

      Pd =
              30  P  G
               377  d 2
      From the EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain of
      the used antenna, the RF power density can be obtained.

FCC ID: PY312400216                                                                               Page No.   : B2 of B3


                                                                                          Report No.: FR310915


1.3. Calculated Result and Limit

      For 5GHz UNII Band:
      Antenna Type : PCB Antenna
      Max Conducted Power for IEEE 802.11n HT20 : 16.93 dBm
                                  Average      Average    Power Density Limit of Power
      Antenna Gain Antenna Gain
                                Output Power Output Power      (S)        Density (S)               Test Result
          (dBi)      (numeric)
                                   (dBm)        (mW)        (mW/cm²)      (mW/cm²)
            3.87         2.4378         16.9309        49.3272        0.023935           1          Complies



      For 5GHz ISM Band:
      Antenna Type : PCB Antenna
      Max Conducted Power for IEEE 802.11ac VHT80 : 26.29 dBm
                                  Average      Average    Power Density Limit of Power
      Antenna Gain Antenna Gain
                                Output Power Output Power      (S)        Density (S)               Test Result
          (dBi)      (numeric)
                                   (dBm)        (mW)        (mW/cm²)      (mW/cm²)
            4.70         2.9512         26.2868       425.2871        0.249823           1          Complies



      For 2.4GHz Band:
      Antenna Type : PCB Antenna
      Max Conducted Power for IEEE 802.11n HT20 : 20.77 dBm
                                  Average      Average    Power Density Limit of Power
      Antenna Gain Antenna Gain
                                Output Power Output Power      (S)        Density (S)               Test Result
          (dBi)      (numeric)
                                   (dBm)        (mW)        (mW/cm²)      (mW/cm²)
            3.91         2.4604         20.7709       119.4226        0.058484           1          Complies


      CONCULSION:
      Both of the WLAN 2.4GHz Band and WLAN 5GHz Band can transmit simultaneously, the formula of
      calculatedthe MPE is:
      CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
      CPD = Calculation power density
      LPD = Limit of power density
      Therefore, the worst-case situation is 0.058484 / 1 + 0.249823 / 1 = 0.308307, which isless than “1”. This
      confirmed that the device comply with FCC 1.1310 MPE limit.




FCC ID: PY312400216                                                                     Page No.   : B3 of B3



Document Created: 2013-02-05 23:55:03
Document Modified: 2013-02-05 23:55:03

© 2024 FCC.report