                           RF EXPOSURE REPORT


                             REPORT NO.: SA110701C24

                              MODEL NO.: UTM9SWLSN

                                  FCC ID: PY311300172

                               RECEIVED: Jul. 1, 2011

                                 TESTED: Sep. 15 ~ 20, 2011

                                  ISSUED: Sep. 26, 2011




                      APPLICANT: Netgear Incorporated

                          ADDRESS: 350 East Plumeria Drive San Jose, CA 95134
                                   U.S.A




                          ISSUED BY: Bureau Veritas Consumer Products Services
                                     (H.K.) Ltd., Taoyuan Branch

                 LAB LOCATION: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist.,
                               New Taipei City 244, Taiwan




 This test report consists of 6 pages in total. It may be duplicated completely for legal use with the
 approval of the applicant. It should not be reproduced, except in full, without the written approval of
 our laboratory. The client should not use it to claim product certification, approval or endorsement by
 any government agency. The test results in the report only apply to the tested sample.




Report No.: SA110701C24                          1                                 Report Format Version 4.0.0


                                    TABLE OF CONTENTS

RELEASE CONTROL RECORD .................................................................................... 3
1.    CERTIFICATION.............................................................................................. 4
2.    RF EXPOSURE LIMIT ..................................................................................... 5
3.    MPE CALCULATION FORMULA ..................................................................... 5
4.    CLASSIFICATION............................................................................................ 5
5.    CALCULATION RESULT OF MAXIMUM CONDUCTED POWER................... 6




Report No.: SA110701C24                               2                                   Report Format Version 4.0.0


                          RELEASE CONTROL RECORD
  ISSUE NO.               REASON FOR CHANGE         DATE ISSUED
  SA110701C24             Original release         Sep. 26, 2011




Report No.: SA110701C24                      3       Report Format Version 4.0.0


1. CERTIFICATION
                PRODUCT: UTM Security Wireless Module
          BRAND NAME: NETGEAR
              MODEL NO.: UTM9SWLSN
              APPLICANT: Netgear Incorporated
               TEST ITEM: ENGINEERING SAMPLE
                   TESTED: Sep. 15 ~ 20, 2011
            STANDARDS: FCC Part 2 (Section 2.1091)
                       FCC OET Bulletin 65, Supplement C (01-01)
                       IEEE C95.1


 The above equipment has been tested by Bureau Veritas Consumer Products
 Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of
 the above standards. The test record, data evaluation & Equipment Under Test (EUT)
 configurations represented herein are true and accurate accounts of the
 measurements of the sample’s EMC characteristics under the conditions specified in
 this report.




   PREPARED BY            :                                        ,   DATE:
                              ( Celia Chen / Senior Specialist )



   APPROVED BY            :                                        ,   DATE:
                                   ( Ken Liu / Manager )




Report No.: SA110701C24                           4                            Report Format Version 4.0.0


2. RF EXPOSURE LIMIT
LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
  FREQUENCY               ELECTRIC FIELD MAGNETIC FIELD POWER DENSITY     AVERAGE TIME
  RANGE (MHz)             STRENGTH (V/m) STRENGTH (A/m)   (mW/cm2)          (minutes)
                LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE
     300-1500                  …                 …         F/1500               30
   1500-100,000                …                 …           1.0                30

F = Frequency in MHz


3. MPE CALCULATION FORMULA
Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm


4. CLASSIFICATION
The antenna of this product, under normal use condition, is at least 20cm away from the
body of the user. So, this device is classified as Mobile Device.




Report No.: SA110701C24                      5                      Report Format Version 4.0.0


5. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER

 FREQUENCY                         ANTENNA                          POWER
                    MAX POWER                     DISTANCE                                LIMIT
    BAND                             GAIN                          DENSITY
                      (dBm)                          (cm)                               (mW/cm2)
    (MHz)                            (dBi)                         (mW/cm2)
   2412-2462              27.6        1.8              20            0.1733                1.00
   5180-5240              15.4        1.8              20            0.0104                1.00
   5745-5825              24.4        1.8              20            0.0829                1.00

Note: The EUT was limited in the host equipment (Product Name: DSL&Wireless N Capable UTM
      Security Appliance, Brand: NETGEAR, Model No.: UTM9S).