RF exp calc

FCC ID: PY308200087

RF Exposure Info

Download: PDF
FCCID_959631

            RF Exposure Evaluation Declaration



             Product Name : 54Mbps Wireless ADSL+ Modem Router
             Model No.              : DG834GU v5; DG834G v5
             FCC ID                 : PY308200087




    Applicant : Netgear Inc.
    Address : 4500 Great America Pky, Santa Clara, CA 95054, USA




                               Date of Receipt : 2008/05/23
                               Issued Date              : 2008/06/16

                               Report No.               : 086S018-RF-US




The test results relate only to the samples tested.
The test results shown in the test report are traceable to the national/international standard through the calibration
of the equipment and evaluated measurement uncertainty herein.
This report must not be used to claim product endorsement by CNLA, NVLAP, NIST or any agency of the
Government.
The test report shall not be reproduced except in full without the written approval of QuieTek Corporation.


                                                                             Report No: 086S018-RF-US



                Test Report Certification
                                                                        Issued Date    : 2008/06/16
                                                                        Report No.    : 086S018-RF-US




Product Name          :   54Mbps Wireless ADSL+ Modem Router
Applicant             :   Netgear Inc.
Address               :   4500 Great America Pky, Santa Clara, CA 95054, USA
Manufacturer          :   Ambit Microsystems (Shanghai) Ltd.
Address               :   No. 1925, Nanle Road Songjiang Export Processing
                          Zone Shanghai China, Post Code: 201613
Model No.             :   DG834GU v5; DG834G v5
FCC ID                :   PY308200087
Rated Voltage         :   AC 120V/60Hz
EUT Voltage           :   AC 100-240 V / 50-60 Hz
Trade Name            :   Netgear
Applicable Standard   :   FCC OET 65
Test Result           :   Complied
Performed Location    :   SuZhou EMC laboratory
                          No.99 Hongye Rd., Suzhou Industrial Park Loufeng
                          Hi-Tech Development Zone., SuZhou, China
                          TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
                          FCC Registration Number: 800392




Documented By         :

                                            (    Any Liu    )

Reviewed By           :

                                        (       Dream Cao       )

Approved By           :

                                    (       Murphy Wang             )




                                    Page: 2 of 6


                                                                           Report No: 086S018-RF-US



Laboratory Information


We , QuieTek Corporation, are an independent EMC and safety consultancy that was
established the whole facility in our laboratories. The test facility has been accredited by the
following accreditation Bodies in compliance with ISO 17025, EN 45001 and Guide 25:


 Taiwan R.O.C.          :   BSMI, DGT, CNLA
 Germany                :   TUV Rheinland
 Norway                 :   Nemko, DNV
 USA                    :   FCC, NVLAP
 Japan                  :   VCCI


The related certificate for our laboratories about the test site and management system can be downloaded
from QuieTek Corporation’s Web Site : http://tw.quietek.com/modules/myalbum/
The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site :
http://www.quietek.com/
If you have any comments, Please don’t hesitate to contact us. Our contact information is as below:


 HsinChu Testing Laboratory :
         No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan,
         R.O.C.
         TEL:+886-3-592-8858 / FAX:+886-3-592-8859       E-Mail : service@quietek.com




 LinKou Testing Laboratory :
         No. 5, Ruei-Shu Valley, Ruei-Ping Tsuen, Lin-Kou Shiang, Taipei, Taiwan, R.O.C.
         TEL : +886-2-8601-3788 / FAX : 886-2-8601-3789       E-Mail : service@quietek.com




 Suzhou Testing Laboratory :
         No.99 Hongye Rd., Suzhou Industrial Park Loufeng Hi-Tech Development Zone., SuZhou, China
         TEL : +86-512-6251-5088 / FAX : 86-512-6251-5098     E-Mail : service@quietek.com




                                             Page: 3 of 6


                                                                       Report No: 086S018-RF-US


1. RF Exposure Evaluation

    Limits

    According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate
    the environment impact of human exposure to radio frequency (RF) radiation as specified in
    1.1307(b)
    LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
                              Electric           Magnetic
                                                                   Power             Average
         Frequency            Field              Field
                                                                   Density           Time
         Range (MHz)          Strength           Strength
                                                                   (mW/cm2)          (Minutes)
                              (V/m)              (A/m)
         (A) Limits for Occupational/ Control Exposures
         300-1500             --                 --                F/300             6
         1500-100,000         --                 --                5                 6
         (B) Limits for General Population/ Uncontrolled Exposures
         300-1500             --                 --                F/1500            6
         1500-100,000         --                 --                1                 30
    F= Frequency in MHz


    Friis Formula
    Friis transmission formula: Pd = (Pout*G)/(4*pi*r2)


    Where
    Pd = power density in mW/cm2
    Pout = output power to antenna in mW
    G = gain of antenna in linear scale
    Pi = 3.1416
    R = distance between observation point and center of the radiator in cm


    Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total
    power input to the antenna, through the calculation, we will know the distance r where the
    MPE limit is reached.




                                          Page: 4 of 6


                                                                       Report No: 086S018-RF-US


        Test Procedure

        Software provided by client enabled the EUT to transmit and receive data at lowest, middle
        and highest channel individually.
        The temperature and related humidity: 18℃and 78% RH.


        Test Result of RF Exposure Evaluation

        Product          :   54Mbps Wireless ADSL+ Modem Router
        Test Item        :   RF Exposure Evaluation
        Test Site        :   AC-3
        Test Mode        :   Mode 1: Transmitter by 802.11b


Antenna Gain:
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.6 dBi or 1.45 in linear
scale.


Output Power Into Antenna & RF Exposure Evaluation Distance:

                        Channel Frequency      Output Power to Antenna Power Density at R = 20 cm
        Channel
                               (MHz)                        (mW)                  (mW/cm2)

          01                  2412.00                  125.8925                   0.036202
          06                  2437.00                  125.0259                   0.035953
          11                  2462.00                      98.6279                0.028362
Note:
    The power density Pd (4th column) at a distance of 20 cm calculated from the Friis transmission
    formula is far below the limit of 1 mW/cm2.




                                            Page: 5 of 6


                                                                     Report No: 086S018-RF-US




        Product       :   54Mbps Wireless ADSL+ Modem Router
        Test Item     :   RF Exposure Evaluation
        Test Site     :   AC-3
        Test Mode     :   Mode 2: Transmitter by 802.11g


Antenna Gain:
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.6 dBi or 1.45 in linear
scale.


Output Power Into Antenna & RF Exposure Evaluation Distance:

                     Channel Frequency       Output Power to Antenna Power Density at R = 20 cm
        Channel
                            (MHz)                         (mW)                 (mW/cm2)

          01               2412.00                   114.8154                  0.033016
          06               2437.00                   109.3956                  0.031458
          11               2462.00                       92.6830               0.026652
Note:
    The power density Pd (4th column) at a distance of 20 cm calculated from the Friis transmission
    formula is far below the limit of 1 mW/cm2.




                                          Page: 6 of 6



Document Created: 2008-06-17 17:56:02
Document Modified: 2008-06-17 17:56:02

© 2024 FCC.report