RF Exposure Evaluation

FCC ID: PY305300016

RF Exposure Info

Download: PDF
FCCID_609782

1.1. Test Result of RF Exposure Evaluation
      . Product: RANGEMAX ADSL MODEM GATEWAY

     . Test Item: RF Exposure Evaluation Data

     . Test site: OATSI-SD

     . Test Mode: Normal Operation

1.1.1. Antenna Gain

      The maximum Gain is 5.3 dBi.

1.1.2. EUT Operation condition

      Software provided by client enabled the EUT to transmit and receive data at lowest,
       middle and highest channel individually.

1.1.3. Output Power into Antenna & RF Exposure Evaluation Distance


   Modulation Standard: IEEE 802.11b
  Test Date: Oct. 21, 2005           Temperature: 25℃      Humidity: 60%
   Channel    Channel Frequency          Output Power to Antenna           Power Density (S)
                   (MHz)                          (dBm)                       (mW/cm2)
      01            2412                          20.05                         0.068
      06            2437                          20.43                         0.074
      11            2462                          19.71                         0.063


   Modulation Standard: IEEE 802.11g
  Test Date: Oct. 21, 2005           Temperature: 25℃      Humidity: 60%
   Channel    Channel Frequency          Output Power to Antenna           Power Density (S)
                   (MHz)                          (dBm)                       (mW/cm2)
      01            2412                          22.31                         0.115
      06            2437                          22.48                         0.119
      11            2462                          21.82                         0.103


   Modulation Standard: 802.11 Super G
  Test Date: Oct. 21, 2005           Temperature: 25℃      Humidity: 60%
   Channel   Channel Frequency       Output Power to Antenna           Power Density (S)
                     (MHz)                    (dBm)                        (mW/cm2)
     01               2412                       ---                            ---
     06               2437                     22.09                          0.109
     11               2462                       ---                            ---
                                       2                 2
 The MPE is calculated as 0.119 mW / cm < limit 1 mW / cm . So, RF exposure limit
 warning or SAR test are not required.



Document Created: 2019-06-06 09:58:00
Document Modified: 2019-06-06 09:58:00

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC