RF Exposure

FCC ID: PXY-KQI-T02S

RF Exposure Info

Download: PDF
FCCID_4018919

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: PXY-KQI-T02S            Report No.: LCS180904010AEA


                                        RF Exposure Evaluation Report

    1. Product Information

      FCC ID:                                           PXY-KQI-T02S
      Product Name                                      Wireless Charger
                                                        KQI-T02S, KQI-T01SS, KQI-T01SM, KQI-T02SS, KQI-T02SM,
      Model Number
                                                        KQI-T01S
      Power Supply                                      Input: DC5V/2A; DC9V/1.67A
      Modulation Type                                   Continuous Wave
      Frequency Range                                   110.0 - 205.0 KHz
      Operation Frequency                               162.0 KHz
      Antenna Type                                      Coil Antenna
      Hardware version                                  /
      Software version                                  /
      Accessories                                       iphone X
      Exposure category                                 General population/uncontrolled environment
      EUT Type                                          Production Unit
      Device Type                                       Mobile Device


    2. Evaluation Method

Per KDB 680106 D01 Section 3. RF Exposure Requirements;
    1) Consumer wireless power transfer devices approved under Part 15 in some cases have to demonstrate
        compliance with RF exposure requirements. The potential for exposure must be assessed according to
        the operating configurations of the wireless system and the exposure conditions of users and
        bystanders. RF exposure must be evaluated with the client device(s) being charged by the primary at
        maximum output power. The RF exposure requirements must be determined in conjunction with the
        device operating characteristics, according to the mobile and portable exposure requirements in
        Section 2.1091 and Section 2.1093 of the rules. SAR and MPE limits do not cover the frequency range
        for wireless power transfer applications which operate below 100 kHz and 300 kHz respectively;
        therefore, RF exposure compliance needs to be determined with respect to 1.1307 (c) and (d) of the
        FCC rules.
    2) Based on the design and implementation of the power transfer application, it must be clearly identified
        if mobile or portable RF exposure conditions apply. Devices that are installed to provide separation of
        at least 20 cm from users and bystanders may qualify for mobile exposure conditions. For some
        conditions where users and bystanders may be exposed at closer than 20 cm, section 2.1091(d) (4) of
        the rules may apply.
    3) For devices designed for typical desktop applications, such a wireless charging pads, RF
       exposureevaluation should be conducted assuming a user separation distance of 15 cm. E and H field
       strengthmeasurements or numerical modeling may be used to demonstrate compliance.
       Measurements shouldbe made from all sides and the top of the primary/client pair, with the 15 cm
       measured from the center of the probe(s) to the edge of the device. Emissions between 100 kHz to 300
       kHz should beassessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63 A/m.
       A KDB inquiry is required to determine the applicable exposure limits below 100 kHz.
    4) Portable exposure conditions from 100 kHz to 6 GHz are determined with respect to SAR requirements.
       Existing SAR systems and test procedures are generally intended for measurements above 100 MHz.
       While numerical modeling can be an alternative, the constraints of substantial computational

___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 1 of 9


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: PXY-KQI-T02S             Report No.: LCS180904010AEA

      resources at low frequencies could introduce further limitations. Under these circumstances, including
      operations below 100 kHz, the Commission may consider a combination of analytical analysis, field
      strength, radiated and conducted power measurements, in conjunction with some limited numerical
      modeling to assess compliance.
   5) Depending on the operating frequency, existing SAR and MPE measurement procedures may be
      adapted to evaluate wireless power transfer devices for compliance with respect to mobile or portable
      exposure conditions. If the grantee or its test lab have any questions regarding RF exposure evaluation
      they should contact the FCC Laboratory with sufficient system operating configuration details to
      determine if RF exposure evaluation is necessary and, if required, how to apply specific test procedures.
      Below 100 MHz, when SAR testing is required and the device is operating at close proximity to persons,
      information on device design, implementation, operating configurations, exposure conditions of users
      and bystanders are needed to determine the evaluation and testing requirements. In addition, the
      influence of nearby objects may also need consideration according to the wireless power transfer
      system implementation; for example, the effects of placing the device, its coils or radiating elements
      on or near metallic surfaces


   3. Evaluation Limit

   3.1 Refer evaluation method

        ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency
        Electromagnetic Fields, 3 kHz to 300 GHz.
        FCC KDB publication 680106 D01 RF Exposure Wireless Charging Apps v03: RF Exposure Considerations
        for Low Power Consumer Wireless Power Transfer Applications
        FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits.
        FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices
        FCC CFR 47 part 15C:Intentional Radiators


   3.2 Limit

          Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure
                 Frequency               Electric Field           Magnetic Field            Power Density            Averaging Time
                Range(MHz)              Strength(V/m)             Strength(A/m)               (mW/cm²)                  (minute)
                                                Limits for Occupational/Controlled Exposure
                   0.3-3.0                     614                      1.63                      *100                        6
                   3.0-30                    1842/f                    4.89/f                   *900/f2                       6
                   30-300                     61.4                      0.163                      1.0                        6
                 300-1,500                       /                        /                      f/300                        6
               1,500-100,000                     /                        /                         5                         6




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 2 of 9


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: PXY-KQI-T02S             Report No.: LCS180904010AEA



          Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure
                 Frequency               Electric Field           Magnetic Field            Power Density            Averaging Time
                Range(MHz)              Strength(V/m)             Strength(A/m)               (mW/cm²)                  (minute)
                                           Limits for General Population/Uncontrolled Exposure
                  0.3-1.34                     614                      1.63                      *100                         30
                   1.34-30                    824/f                    2.19/f                   *180/f2                        30
                   30-300                     27.5                      0.073                      0.2                         30
                 300-1,500                       /                        /                      f/1500                        30
               1,500-100,000                     /                        /                        1.0                         30

          F=frequency in MHz
          *=Plane-wave equivalent power density


          According to FCC KDB 680106 D01 Section 3. RF Exposure Requirements clause 3 the Emission-Limits
          in the frequency range from 100 KHz to 300 KHz should be assessed versus the limits at 300 KHz in
          Table 1 of CFR 47 – Section1.310 as following (measured distance shall be 15cm from the center of
          the probe to the edge of the device):
                                                      E-Field                            */*                           B-Field
                   Frequency                           V/m                              A/m                               uT
              0.3 MHz – 3.0 MHz                         614                            1.613                             2.0
              3.0 MHz – 30 MHz                 824/f (=27.530MHz)               2.19/f (=0.07330MHz)                      --

          A KDB inquire was required to determine/confirm the applicable limits below 100 KHz.


   4. Test Setup Diagram




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 3 of 9


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: PXY-KQI-T02S            Report No.: LCS180904010AEA



   5. Test Equipment

     Equipment           Manufacturer             Model               Serial no.        Calibrated date          Calibrated Due
   Exposure Level
                             Narda               ELT-400               N-0713              2018-04-02              2019-04-01
       Tester
    B-Field Probe            Narda               ELT-400               M-1154              2018-04-11              2019-04-10


   6. Measurement Procedure

          a) The RF exposure test was performed on 360 degree turn table in anechoic chamber.
          b) The measurement probe was placed at test distance (15cm and 20cm) which is between the edge
          of the chargerand the geometric center of probe.
          c) The turn table was rotated 360d degree to search of highest strength.
          d) The highest emission level was recorded and compared with limit as soon as measurement of each
          points(A, B, C, D, E) were completed.
          e) The EUT were measured according to the dictates of KDB 680106D01v03.
   7. Equipment Approval Considerations

          The EUT does comply with item 5.2 of KDB 680106 D01v03 as follows table;
    Requirements of KDB 680106 D01                           Yes / No         Description
                                                                              The device operate in the frequency range
    Power transfer frequency is less than 1 MHz              Yes
                                                                              110.0 KHz - 205.0 KHz
    Output power from each primary coil is less                               The maximum output power of the primary
                                                             Yes
    than 15 watts                                                             coil is less than 10W.
    The transfer system includes only single
    primary and secondary coils. This includes
    charging systems that may have multiple                                   The transfer system includes single coil that
                                                             Yes
    primary coils and clients that are able to                                is able to detect receiver device.
    detect and allow coupling only between
    individual pairs of coils.
    Client device is placed directly in contact with                          Client device is placed directly in contact
                                                             Yes
    the transmitter.                                                          with the transmitter.
    Mobile exposure conditions only (portable
    exposure conditions are not covered by this              Yes              Mobile exposure conditions only
    exclusion).
    The aggregate H-field strengths at 15 cm                                  The EUT H-field strengths at 15 cm
    surrounding the device and 20 cm above the                                surrounding the device and 20 cm above the
    top surface from all simultaneous                        Yes              top surface from all simultaneous
    transmitting coils are demonstrated to be                                 transmitting coils are demonstrated to be
    less than 50% of the MPE limit.                                           less than 50% of the MPE limit.

          In all other cases, unless excluded above, an RF exposure evaluation report must be reviewed and
          accepted through a KDB or PBA inquiry to enable authorization of the equipment. When evaluation is
          required to show compliance; for example, using field strength, power density, SAR measurements or
          computational modeling etc., the specific authorization requirements will be determined based on

___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 4 of 9


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: PXY-KQI-T02S            Report No.: LCS180904010AEA

           the results of the RF exposure evaluation
    8. E and H field Strength

           Test mode: Normal Operation (Charging mode)

E-Field Strength at 15 cm from the edges surrounding the EUT and 15cm from the top surface of the EUT

                                             Measured E-Field Strength Values (V/m)                                               FCC
                                                                                                              FCC E-Field
Charging      Frequency                                                                                                         E-Field
                                                                                                               Strength
 Battery        Range             Test          Test            Test            Test            Test                           Strength
                                                                                                              50% Limits
  Level         (MHz)          Position A     Position B      Position C     Position D       Position E                        Limits
                                                                                                                (V/m)
                                                                                                                                (V/m)
   1%            0.1620            4.57           4.64           4.62           4.70             6.18            307.0            614.0
  50%            0.1620            4.46           4.53           4.67           4.58             5.98            307.0            614.0
  99%            0.1620            4.38           4.30           4.55           4.38             5.82            307.0            614.0

H-Field Strength at 15 cm from the edges surrounding the EUTand 15cm from the top surface of the EUT
                                             Measured H-Field Strength Values (A/m)                              FCC            FCC
 Charging       Frequency                                                                                      H-Field        H-Field
                                                                                Test
  Battery         Range            Test          Test           Test                           Test           Strength       Strength
                                                                              Position
   Level          (MHz)         Position A     Position B     Position C                     Position E      50% Limits       Limits
                                                                                 D
                                                                                                               (A/m)          (A/m)
    1%            0.1620           0.112         0.118          0.089          0.099            0.102           0.815           1.63
    50%           0.1620           0.109         0.106          0.095          0.079            0.096           0.815           1.63
    99%           0.1620           0.106         0.099          0.084          0.078            0.097           0.815           1.63

H-Field Strength at 20cm from the top surface of the EUT
                                                   Measured H-Field Strength
 Charging                                                                                     FCC H-Field              FCC H-Field
                    Frequency Range                     Values (A/m)
  Battery                                                                                    Strength 50%            Strength Limits
                         (MHz)                                  Test
   Level                                                                                     Limits (A/m)                (A/m)
                                                              Position E
    1%                    0.1620                                0.082                             0.815                    1.63
    50%                   0.1620                                0.074                             0.815                    1.63
    99%                   0.1620                                0.065                             0.815                    1.63




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 5 of 9


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: PXY-KQI-T02S            Report No.: LCS180904010AEA




   9. Test Setup Photos




                                                       20cm




                                   TestPosition E-Exposure photo from top surface(20cm)




                                                15cm




                                   TestPosition E-Exposure photo from top surface(15cm)




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 6 of 9


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: PXY-KQI-T02S            Report No.: LCS180904010AEA




                                     15cm




                                   TestPosition A-Exposure photo from side edge surface-Rear




                                                                               15cm




                                   TestPosition B-Exposure photo from side edge surface-Left




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 7 of 9


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: PXY-KQI-T02S            Report No.: LCS180904010AEA




                                                 15cm




                                  TestPosition C-Exposure photo from side edge surface-Front




                                                    15cm




                                  TestPosition D-Exposure photo from side edge surface-Right




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 8 of 9


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: PXY-KQI-T02S            Report No.: LCS180904010AEA



   10. Conclusion

          A minimum safety distance of at 15 cm surrounding the device and 20 cm above the top surface of
          the device is required when the device is charging a smart phone. The detected emissions with a
          distance of 15 cm surrounding the device and 20 cm above the top surface of the device are below
          the limitations according to FCC KDB 680106 D01 Section 3. RF Exposure Requirement Clause 3.



                                                       Revision History
           Revision                        Issue Date                           Revisions                        Revised By
             000                       September 18, 2018                      Initial Issue                     Gavin Liang




                              .........................END OF REPORT.........................