TestRep 15B

FCC ID: PXA-K022B

Test Report

Download: PDF
FCCID_2626891

                                                         EMC TEST REPORT
                                                          FCC 47 CFR Part 15B
                                                        Industry Canada RSS-Gen
                                  Electromagnetic compatibility - Unintentional radiators

Report Reference No. .................... : G0M-1411-4308-EF0115B-V02

Testing Laboratory ........................ : Eurofins Product Service GmbH

Address ............................................ : Storkower Str. 38c
                                                       15526 Reichenwalde
                                                       Germany

Accreditation .................................... :




                                                       A2LA Accredited Testing Laboratory, Certificate No.: 1983.01
                                                       FCC Filed Test Laboratory, Reg.-No.: 96970
                                                       IC OATS Filing assigned code: 3470A

Applicant’s name ........................... : Spectralink Europe ApS

Address ............................................ : Langmarksvej 34
                                                       8700 Horsens
                                                       DENMARK

Test specification:

Standard ........................................... : 47 CFR Part 15 Subpart B
                                                       RSS-Gen, Issue 3, 2010-12
                                                       ANSI C63.4:2009

Equipment under test (EUT):

Product description                                    DECT handset 7522

Model No.                                              K022b

Additional Models                                      None

Hardware version                                       PCS 03

Firmware / Software version                            PCS 14BA

IDs                                                    FCC-ID: PXA-K022B                     IC: 4604A-K022B

Test result                                            Passed




                                         Test Report No.: G0M-1411-4308-EF0115B-V02
                                                       Eurofins Product Service GmbH
                                         Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                               Page 1 of 23


   «s eurofins |
                                         Product Service



Possible test case verdicts:

— NOt applicabl@ t0 t@St ObJ@Qt .................ecceeeeeeet     NA

— test object does meet the requirement....                      P (Pass)

— test object does not meet the requirement.................:    F (Fail)

Testing:

Date Of r@C@IPt Of t@St t@M ...............ccscsceeemeeeee?      2014—11—18

Date (s) of performance Of tests .................c.l.c.cl..l    2014—12—23

COMPiIGU DY.........cccceelllll.......;         Steffen Zunke                                        y

Tested by (+ signature).....................:   Steffen Zunke                          2//6‘...................

Approved by (+ signature) ................:     Marous Klein                           /é/%'.........................

Dat@ Of IB8U@ ... 2016—02—25

Total number of pages......................:    23

General remarks:

The test results presented in this report relate only to the object tested.
The results contained in this report reflect the results for this particular model and serial number. It
is the responsibility of the manufacturer to ensure thatall production models meet the intent of the
requirements detailed within this report.


This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.

Additional comments:

The DECT phone K022b is identical with the DECT phone K022a except the Bluetooth module. The DECT
phone K022b has no Bluetooth module integrated on the PCB. For the DECT phone K022b the radiated
emission was measured in DECT mode only. For all other measurements the tests from K022a are valid too.
The measurement results were showed in the report GOM—1411—4306—EF0115B—V01 from the DECT phone
KO22a.
The customer declares the identical of K022a and KO22b in following document DiT_KO22Zab.




                                   Test Report No.: GOM—1411—4308—EF0115B—V02
                                                  Eurofins Product Service GmbH
                                   Storkower Str. 38¢, D—15526 Reichenwalde, Germany
                                                                                                         Page 2 of 23


Version History
Version   Issue Date      Remarks                                                Revised by
V01       2015-02-25      Initial Release
V02       2015-02-25      Replaced document:         G0M-1411-4308-EF0115B-V01   S: Zunke
                          Replaced by:               G0M-1411-4308-EF0115B-V02

                          Reason:

                          FCC ID and IC ID changed




                       Test Report No.: G0M-1411-4308-EF0115B-V02
                                     Eurofins Product Service GmbH
                       Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                  Page 3 of 23


REPORT INDEX


1     EQUIPMENT (TEST ITEM) DESCRIPTION                                                    5

1.1   Photos – Equipment external                                                          6
1.2   Photos – Equipment internal                                                          7
1.3   Photos – Test setup                                                                  8
1.4   Supporting Equipment Used During Testing                                             9
1.5   Input / Output Ports                                                                 9
1.6   Operating Modes and Configurations                                                  10
1.7   Test Equipment Used During Testing                                                  11
1.8   Sample emission level calculation                                                   12

2     RESULT SUMMARY                                                                      13

3     TEST CONDITIONS AND RESULTS                                                         14

3.1   Test Conditions and Results – Radiated emissions                                    14




                             Test Report No.: G0M-1411-4308-EF0115B-V02
                                           Eurofins Product Service GmbH
                             Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                 Page 4 of 23


1    Equipment (Test item) Description

Description                       DECT handset 7522

Model                             K022b

Additional Models                 None

Serial number                     None

Hardware version                  PCS 03

Software / Firmware version       PCS 14BA

FCC-ID                            PXA-K022B

IC                                4604A-K022B

Power supply                      3.7 VDC via rechargeable Battery

                                  Model : UE08WCP-060100SPA
                                  Manufacturer : Fuhua
AC/DC-Adaptor
                                  Input : 100-240VAC / 50-60Hz
                                  Output : 6VDC / 1.0A
                                  Type                     DECT module
                                  Model                    KT4588A00
                                  Manufacturer             Spectralink
Radio module                      HW Version               PCS 04
                                  SW Version               PCS 14A
                                  FCC-ID                   -
                                  IC                       -
                                  Spectralink Europe ApS
                                  Langmarksvej 34
Manufacturer
                                  8700 Horsens
                                  DENMARK

Highest emission frequency        Fmax [MHz] = 4966

Device classification             Class B

Equipment type                    Tabletop

Number of tested samples          1




                        Test Report No.: G0M-1411-4308-EF0115B-V02
                                      Eurofins Product Service GmbH
                        Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                            Page 5 of 23


1.1   Photos – Equipment external


                                            EUT Front




                                            EUT Back




                       Test Report No.: G0M-1411-4308-EF0115B-V02
                                     Eurofins Product Service GmbH
                       Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                           Page 6 of 23


1.2   Photos – Equipment internal


                                           PCB Front




                                            PCB Back




                        Test Report No.: G0M-1411-4308-EF0115B-V02
                                     Eurofins Product Service GmbH
                       Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                           Page 7 of 23


1.3   Photos – Test setup


                               Test Setup : Radiated Emissions




                        Test Report No.: G0M-1411-4308-EF0115B-V02
                                      Eurofins Product Service GmbH
                        Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                            Page 8 of 23


  1.4       Supporting Equipment Used During Testing


Product
                       Device                      Manufacturer             Model No.       Comments
 Type*
   AE          IP-DECT Server 400                    Spectralink                 K005             -

   AE               DECT Phone                       Spectralink               K022b              -
                                                                            UE08WCP-
   AE              Power Supply                        Fuhua                                      -
                                                                            060100SPA
   AE             Charger, single                    Spectralink             84642472             -

   AE          Charger, single, USB                  Spectralink             84642473             -

*Note: Use the following abbreviations:
        AE : Auxiliary/Associated Equipment, or

        SIM : Simulator (Not Subjected to Test)

    CABL : Connecting cables



  1.5       Input / Output Ports

                                                        Max. Cable       Cable
 Port #              Name                    Type*                                        Comments
                                                         Length         Shielded
   1                 Power                    AC            >3m             No               -

*Note: Use the following abbreviations:
         AC : AC power port

         DC : DC power port

        N/E : Non electrical

         I/O : Signal input or output port

         TP : Telecommunication port




                                      Test Report No.: G0M-1411-4308-EF0115B-V02
                                                    Eurofins Product Service GmbH
                                      Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                 Page 9 of 23


 1.6     Operating Modes and Configurations


Mode #                                                Description
           DECT link to another phone, battery powered
   1



Configuration #                                       EUT Configuration
                  Normal configuration, using DECT antenna 1, DECT test mode
       1

                  Normal configuration, using DECT antenna 2, DECT test mode
       2




                            Test Report No.: G0M-1411-4308-EF0115B-V02
                                          Eurofins Product Service GmbH
                            Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                Page 10 of 23


 1.7    Test Equipment Used During Testing


                                        Measurement Software
       Description               Manufacturer                          Name                    Version
  EMC Test Software            Dare Instruments                     Radimation                2014.1.15


                                          Radiated emissions
   Description       Manufacturer          Model               Identifier        Cal. Date       Cal. Due
Biconical Antenna       R&S               HK 116               EF00012           2013-02          2016-02
  LPD-Antenne           R&S               HL 223               EF00187           2014-03         2017-03
  Horn antenna       Schwarzbeck       BBHA 9120D              EF00018           2013-09         2016-09
EMI Test Receiver       R&S               ESU26                EF00887           2014-01         2015-01

                                         Conducted emissions
   Description       Manufacturer          Model               Identifier        Cal. Date       Cal. Due
       AMN              R&S              ESH2-Z5               EF00182           2014-11         2016-11
EMI Test Receiver       R&S              ESCS 30               EF00295           2014-10         2015-10




                           Test Report No.: G0M-1411-4308-EF0115B-V02
                                         Eurofins Product Service GmbH
                           Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                             Page 11 of 23


1.8      Sample emission level calculation

The following is a description of terms and a sample calculation, as appears in the radiated emissions
data table. The numbers used in the calculation are for example only. There is no direct correlation to
the specific data taken for the product described in this document:

Reading:

This is the reading obtained on the spectrum analyzer in dBµV. Any external preamplifiers used are
taken into account through internal analyzer settings.

A.F.:

This is the antenna factor for the receiving antenna. It is a conversion factor, which converts electric
fields strengths to voltages, which can be measured directly on the spectrum analyzer. It is treated as
a loss in dB. Cable losses have been included with the A.F. to simplify the calculations. The antenna
factor is used in calculations as follows:

                 Reading on Analyzer (dBµV) + A.F. (dB) = Net field strength (dBµV/m)

Net:

This is the net field strength measurement (as shown above).

Limit:

This is the FCC Class B radiated emission limit (in units of dBµV/m). The FCC limits are given in units
of µV/m. The following formula is used to convert the units of µV/m to dBµV/m:

                                    Limit (dBµV/m) = 20*log (µV/m)

Margin:

This is the margin of compliance below the FCC limit. The units are given in dB. A negative margin
indicates the emission was below the limit. A positive margin indicates that the emission exceeds the
limit.

Example only:

          Reading + AF      =       Net Reading       :    Net reading - FCC limit = Margin
          21.5 dBµV + 26 dB =       47.5 dBµV/m       :    47.5 dBµV/m - 57.0 dBµV/m = -9.5 dB




                           Test Report No.: G0M-1411-4308-EF0115B-V02
                                         Eurofins Product Service GmbH
                           Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                          Page 12 of 23


  2    Result Summary


                             FCC 47 CFR Part 15B, Industry Canada RSS-Gen

 Product Specific                                                    Reference
                                  Requirement – Test                               Result          Remarks
    Standard                                                          Method
   47 CFR 15.109
                      Radiated emissions                             ANSI C 63.4   PASS                 -
 RSS-Gen 4.9 & 4.10

   47 CFR 15.107                                                                            See report G0M-1411-4306-
                      AC power line conducted emissions              ANSI C63.4    PASS
   RSS-Gen 7.2.4                                                                                  EF0115B-V01 -
Remarks:




                               Test Report No.: G0M-1411-4308-EF0115B-V02
                                             Eurofins Product Service GmbH
                               Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                  Page 13 of 23


  3      Test Conditions and Results

  3.1     Test Conditions and Results – Radiated emissions


Radiated emissions acc. FCC 47 CFR 15.109 / IC RSS-Gen                                                 Verdict: PASS
          Laboratory Parameters:                  Required prior to the test                    During the test
           Ambient Temperature                            15 to 35 °C                               23°C
             Relative Humidity                            30 to 60 %                                 31%

         Test according referenced                                         Reference Method
                 standards                                                    ANSI C63.4

  Sample is tested with respect to the                                      Equipment class
 requirements of the equipment class                                            Class B

Test frequency range determined from                               Highest emission frequency
      highest emission frequency                                           Fmax [MHz] = 4966

 Fully configured sample scanned over                                       Frequency range
      the following frequency range                                        30 MHz to 18 GHz
      Operating mode configuration                                                   1
                                            Limits and results Class B
Frequency [MHz]       Quasi-Peak [dBµV/m] Result            Average [dBµV/m]             Result Peak [dBµV/m] Result
        30 – 88                   40              PASS                 -                               -           -
      88 – 216                   43.5             PASS                 -                               -           -
      216 – 960                   46              PASS                 -                               -           -
   960 – 1000                     54              PASS                 -                               -           -
        > 1000                     -                 -               54                  PASS         74          PASS
Comments:
Measurements were performed up to 18 GHz, above 18 GHz no relevant emission were determined.




                                 Test Report No.: G0M-1411-4308-EF0115B-V02
                                               Eurofins Product Service GmbH
                                 Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                       Page 14 of 23


Test Procedure:

The test site is in accordance with ANSI C63-4:2009 requirements and is listed by FCC.
The measurement procedure is as follows:

   1) The EUT was placed on a 0.8 m non conductive table at a 3 m distance from the receive
      antenna (ANSI C63.4: 2009 item 6.2)
   2) The antenna output was connected to the measurement receiver
   3) A biconical antenna was used for the frequency range 30 – 200 MHz, a logarithmic periodical
      antenna was used for the frequency range from 200 – 1000 MHz. Above one 1 GHz a Double
      Ridged Broadband Horn antenna was used. The antenna was placed on an adjustable height
      antenna mast
   4) Emissions were maximized at each frequency by rotating the EUT and adjusting the receive
      antenna height and polarization. The maximum values were recorded.




                          Test Report No.: G0M-1411-4308-EF0115B-V02
                                        Eurofins Product Service GmbH
                          Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                         Page 15 of 23


  Spurious emissions under normal conditions according to FCC Part 15b

  Project number: G0M-1411-4308

  Manufacturer:                                                   Spectralink Europe ApS
  EUT Name:                                                       DECT handset 7522
  Model:                                                          K022b
  Test Site:                                                      Eurofins Product Service GmbH
  Operator:                                                       Mr. Zunke
  Test Conditions:                                                Tnom: 23°C, Unom: 3.7VDC via rechargeable Battery
  Antenna:                                                        Rohde & Schwarz HK 116, Vertical
  Measurement distance:                                           3m
  Mode:                                                           DECT link to another phone
  Test Date:                                                      2014-12-23
  Note:
                                                                                                                                             Index 9

                                    FCC part 15B Class B QP        RBW: 120 kHz, Vertical Max Peak



                            60




                            50




                            40
Electrical Field (dBµV/m)




                            30




                            20




                            10




                            0




                             30 M              40 M                       60 M                  80 M     100 M    120 M   140 M   160 M     200 M

                                                                                        Frequency (Hz)




                                                              Test Report No.: G0M-1411-4308-EF0115B-V02
                                                                            Eurofins Product Service GmbH
                                                              Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                                     Page 16 of 23


  Spurious emissions under normal conditions according to FCC Part 15b

  Project number: G0M-1411-4308

  Manufacturer:                                                   Spectralink Europe ApS
  EUT Name:                                                       DECT handset 7522
  Model:                                                          K022b
  Test Site:                                                      Eurofins Product Service GmbH
  Operator:                                                       Mr. Zunke
  Test Conditions:                                                Tnom: 23°C, Unom: 3.7VDC via rechargeable Battery
  Antenna:                                                        Rohde & Schwarz HK 116, Horizontal
  Measurement distance:                                           3m
  Mode:                                                           DECT link to another phone
  Test Date:                                                      2014-12-23
  Note:
                                                                                                                                             Index 10

                                    FCC part 15B Class B QP        RBW: 120 kHz, Horizontal Max Peak



                            60




                            50




                            40
Electrical Field (dBµV/m)




                            30




                            20




                            10




                            0




                             30 M              40 M                       60 M                 80 M      100 M    120 M   140 M   160 M     200 M

                                                                                        Frequency (Hz)




                                                              Test Report No.: G0M-1411-4308-EF0115B-V02
                                                                            Eurofins Product Service GmbH
                                                              Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                                     Page 17 of 23


  Spurious emissions under normal conditions according to FCC Part 15b

  Project number: G0M-1411-4308

  Manufacturer:                                                       Spectralink Europe ApS
  EUT Name:                                                           DECT handset 7522
  Model:                                                              K022b
  Test Site:                                                          Eurofins Product Service GmbH
  Operator:                                                           Mr. Zunke
  Test Conditions:                                                    Tnom: 23°C, Unom: 3.7VDC via rechargeable Battery
  Antenna:                                                            Rohde & Schwarz HL 223, Vertical
  Measurement distance:                                               3m
  Mode:                                                               DECT link to another phone
  Test Date:                                                          2014-12-23
  Note:
                                                                                                                                                    Index 11

                                    FCC part 15B Class B QP           RBW: 120 kHz, Vertical Max Peak
                            65


                            60


                            55


                            50


                            45
Electrical Field (dBµV/m)




                            40


                            35


                            30


                            25


                            20


                            15


                            10


                            5
                            200 M                             300 M                   400 M                 500 M   600 M   700 M   800 M           1G

                                                                                           Frequency (Hz)




                                                               Test Report No.: G0M-1411-4308-EF0115B-V02
                                                                             Eurofins Product Service GmbH
                                                               Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                                            Page 18 of 23


  Spurious emissions under normal conditions according to FCC Part 15b

  Project number: G0M-1411-4308

  Manufacturer:                                                       Spectralink Europe ApS
  EUT Name:                                                           DECT handset 7522
  Model:                                                              K022b
  Test Site:                                                          Eurofins Product Service GmbH
  Operator:                                                           Mr. Zunke
  Test Conditions:                                                    Tnom: 23°C, Unom: 3.7VDC via rechargeable Battery
  Antenna:                                                            Rohde & Schwarz HL 223, Horizontal
  Measurement distance:                                               3m
  Mode:                                                               DECT link to another phone
  Test Date:                                                          2014-12-23
  Note:
                                                                                                                                                    Index 12

                                    FCC part 15B Class B QP           RBW: 120 kHz, Horizontal Max Peak
                            65


                            60


                            55


                            50


                            45
Electrical Field (dBµV/m)




                            40


                            35


                            30


                            25


                            20


                            15


                            10


                            5
                            200 M                             300 M                   400 M                 500 M   600 M   700 M   800 M           1G

                                                                                           Frequency (Hz)




                                                               Test Report No.: G0M-1411-4308-EF0115B-V02
                                                                             Eurofins Product Service GmbH
                                                               Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                                            Page 19 of 23


  Spurious emissions under normal conditions according to FCC Part 15b

  Project number: G0M-1411-4308

  Manufacturer:                                                   Spectralink Europe ApS
  EUT Name:                                                       DECT handset 7522
  Model:                                                          K022b
  Test Site:                                                      Eurofins Product Service GmbH
  Operator:                                                       Mr. Zunke
  Test Conditions:                                                Tnom: 23°C, Unom: 3.7VDC via rechargeable Battery
  Antenna:                                                        Schwarzbeck BBHA 9120D, Vertical
  Measurement distance:                                           3m
  Mode:                                                           DECT link to another phone
  Test Date:                                                      2014-12-23
  Note:
                                                                                                                                                         Index 14

                                  FCC part 15B Class B AV         FCC part 15B Class B Peak             RBW: 1 MHz, Vertical Max Average
                                  RBW: 1 MHz, Vertical Max Peak



                            80



                                                                    1
                            70




                            60
Electrical Field (dBµV/m)




                            50




                            40




                            30




                            20



                             1G                                         2G                       3G                    4G              5G   6G           8G

                                                                                       Frequency (Hz)

  Frequency
  1.922 GHz DECT carrier




                                                            Test Report No.: G0M-1411-4308-EF0115B-V02
                                                                          Eurofins Product Service GmbH
                                                            Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                                                 Page 20 of 23


  Spurious emissions under normal conditions according to FCC Part 15b

  Project number: G0M-1411-4308

  Manufacturer:                                                   Spectralink Europe ApS
  EUT Name:                                                       DECT handset 7522
  Model:                                                          K022b
  Test Site:                                                      Eurofins Product Service GmbH
  Operator:                                                       Mr. Zunke
  Test Conditions:                                                Tnom: 23°C, Unom: 3.7VDC via rechargeable Battery
  Antenna:                                                        Schwarzbeck BBHA 9120D, Horizontal
  Measurement distance:                                           3m
  Mode:                                                           DECT link to another phone
  Test Date:                                                      2014-12-23
  Note:
                                                                                                                                                           Index 13

                                  FCC part 15B Class B AV         FCC part 15B Class B Peak              RBW: 1 MHz, Horizontal Max Average
                                  RBW: 1 MHz, Horizontal Max Peak



                            80




                            70
                                                                     1



                            60
Electrical Field (dBµV/m)




                            50




                            40




                            30




                            20



                             1G                                          2G                       3G                    4G             5G     6G           8G

                                                                                        Frequency (Hz)

  Frequency
  1.922 GHz DECT carrier




                                                           Test Report No.: G0M-1411-4308-EF0115B-V02
                                                                         Eurofins Product Service GmbH
                                                           Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                                                   Page 21 of 23


  Spurious emissions under normal conditions according to FCC Part 15b

  Project number: G0M-1411-4308

  Manufacturer:                                                   Spectralink Europe ApS
  EUT Name:                                                       DECT handset 7522
  Model:                                                          K022b
  Test Site:                                                      Eurofins Product Service GmbH
  Operator:                                                       Mr. Zunke
  Test Conditions:                                                Tnom: 23°C, Unom: 3.7VDC via rechargeable Battery
  Antenna:                                                        Schwarzbeck BBHA 9120D, Vertical
  Measurement distance:                                           3m
  Mode:                                                           DECT link to another phone
  Test Date:                                                      2014-12-23
  Note:
                                                                                                                                                          Index 15

                                  FCC part 15B Class B AV         FCC part 15B Class B Peak             RBW: 1 MHz, Vertical Max Average
                                  RBW: 1 MHz, Vertical Max Peak



                            80




                            70




                            60
Electrical Field (dBµV/m)




                            50




                            40




                            30




                            20



                             8G                               10 G                            12 G                        14 G             16 G           18 G

                                                                                       Frequency (Hz)




                                                            Test Report No.: G0M-1411-4308-EF0115B-V02
                                                                          Eurofins Product Service GmbH
                                                            Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                                                  Page 22 of 23


  Spurious emissions under normal conditions according to FCC Part 15b

  Project number: G0M-1411-4308

  Manufacturer:                                                   Spectralink Europe ApS
  EUT Name:                                                       DECT handset 7522
  Model:                                                          K022b
  Test Site:                                                      Eurofins Product Service GmbH
  Operator:                                                       Mr. Zunke
  Test Conditions:                                                Tnom: 23°C, Unom: 3.7VDC via rechargeable Battery
  Antenna:                                                        Schwarzbeck BBHA 9120D, Horizontal
  Measurement distance:                                           3m
  Mode:                                                           DECT link to another phone
  Test Date:                                                      2014-12-23
  Note:
                                                                                                                                                             Index 16

                                  FCC part 15B Class B AV         FCC part 15B Class B Peak              RBW: 1 MHz, Horizontal Max Average
                                  RBW: 1 MHz, Horizontal Max Peak



                            80




                            70




                            60
Electrical Field (dBµV/m)




                            50




                            40




                            30




                            20



                             8G                               10 G                            12 G                         14 G               16 G           18 G

                                                                                        Frequency (Hz)




                                                           Test Report No.: G0M-1411-4308-EF0115B-V02
                                                                         Eurofins Product Service GmbH
                                                           Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                                                     Page 23 of 23



Document Created: 2015-02-25 13:43:42
Document Modified: 2015-02-25 13:43:42

© 2024 FCC.report