RF Exposure

FCC ID: PWO460056

RF Exposure Info

Download: PDF
FCCID_4228015

January 8, 2019
Subject: RF MPE EXPOSURE
Re: FCC ID: PWO 460056

To Whom It May Concern:

The MPE calculations for model 460056 signal booster were done for each frequency band: 700 MHz
Band 12, 700 MHz Band 13, 800 MHz, 1900 MHz, and 1700/2100 MHz. For each band one calculation
was done; this included mobile outside antenna, and mobile inside antenna that may be connected to
this signal booster. The order of the attached calculations is as follows:

       700 MHz Band 12:
              1. Inside Antenna: 311160           2. Outside Antenna: 304421‐5820
       700 MHz Band 13:
             1. Inside Antenna: 311160            2. Outside Antenna: 304421‐5820
       800 MHz band:
             1. Inside Antenna: 311160            2. Outside Antenna: 304421‐5820
       1900 MHz band:
              1. Inside Antenna: 311160           2. Outside Antenna: 304421‐5820
       1700/2100 MHz band:
              1. Inside Antenna: 311160           2. Outside Antenna: 304421‐0630

A booster’s uplink power must not exceed 1 watt equivalent isotropic radiated power (EIRP) for each
band of operation. Composite downlink power must not exceed 0.05 watt EIRP for each band of
operation (20.21(e)(8)(i)(D)). The following formula was used to calculate the equivalent isotropic
radiated power:
       EIRP= Power Out (Watts)*Duty Cycle Percent*Antenna Gain (non‐log)*Coax loss (non‐log)

The power density (mW/cm2) is calculated using the following formula:
       Calculated Power Density=1000*EIRP (Watts)/(4*π*(Distance from Antenna (cm)^2))



Sincerely,



Erin Elder
IP & Regulatory Compliance Engineer


                Minimum Safe Distance From Antennas
               Based upon FCC OET Bulletin 65 and other FCC Sources


             INPUT DATA
             Frequency MHz                                728
             Pout Watts                               0.00316
             Duty Cycle Percent                       100.0%
             Ant. Gain dBi                               4.18
             Coax Loss dB                                0.00
             Distance From Antenna In cm                 20.3

             RESULTS OF CALCULATIONS
             Ant. Gain less Coax Loss dBi                4.18
             Distance From Antenna In Inches             8.00
             EIRP (Watts)                              0.0083
             FCC Power Density Limit (mw/cm2)            0.49
             Calculated Power Density (mw/cm2)         0.0016


             REFERENCE DATA
             Pout dBm                                     5.00
             Antenna Gain (non-log)                       2.62
             Coax loss (non-log)                          1.00
             General FCC Limit (mw/cm 2)               f/1500




1/11/2019, 3:27 PM                                                    700 Band 12 DL


                Minimum Safe Distance From Antennas
               Based upon FCC OET Bulletin 65 and other FCC Sources


             INPUT DATA
             Frequency MHz                                698
             Pout Watts                               0.67608
             Duty Cycle Percent                       100.0%
             Ant. Gain dBi                               1.94
             Coax Loss dB                                1.20
             Distance From Antenna In cm                 20.3

             RESULTS OF CALCULATIONS
             Ant. Gain less Coax Loss dBi                0.74
             Distance From Antenna In Inches             8.00
             EIRP (Watts)                              0.8022
             FCC Power Density Limit (mw/cm2)            0.47
             Calculated Power Density (mw/cm2)         0.1548


             REFERENCE DATA
             Pout dBm                                   28.30
             Antenna Gain (non-log)                       1.56
             Coax loss (non-log)                          0.76
             General FCC Limit (mw/cm 2)               f/1500




1/11/2019, 3:27 PM                                                    700 Band 12 UL


                Minimum Safe Distance From Antennas
               Based upon FCC OET Bulletin 65 and other FCC Sources


             INPUT DATA
             Frequency MHz                                746
             Pout Watts                               0.00331
             Duty Cycle Percent                       100.0%
             Ant. Gain dBi                                5.8
             Coax Loss dB                                 0.0
             Distance From Antenna In cm                 20.3

             RESULTS OF CALCULATIONS
             Ant. Gain less Coax Loss dBi                5.84
             Distance From Antenna In Inches             8.00
             EIRP (Watts)                              0.0127
             FCC Power Density Limit (mw/cm2)            0.50
             Calculated Power Density (mw/cm2)         0.0025


             REFERENCE DATA
             Pout dBm                                     5.20
             Antenna Gain (non-log)                       3.84
             Coax loss (non-log)                          1.00
             General FCC Limit (mw/cm 2)               f/1500




1/11/2019, 3:27 PM                                                    700 Band 13 DL


                Minimum Safe Distance From Antennas
               Based upon FCC OET Bulletin 65 and other FCC Sources


             INPUT DATA
             Frequency MHz                                777
             Pout Watts                               0.81283
             Duty Cycle Percent                       100.0%
             Ant. Gain dBi                                0.0
             Coax Loss dB                                 1.2
             Distance From Antenna In cm                 20.3

             RESULTS OF CALCULATIONS
             Ant. Gain less Coax Loss dBi                -1.19
             Distance From Antenna In Inches              8.00
             EIRP (Watts)                              0.6177
             FCC Power Density Limit (mw/cm2)             0.52
             Calculated Power Density (mw/cm2)         0.1192


             REFERENCE DATA
             Pout dBm                                   29.10
             Antenna Gain (non-log)                       1.01
             Coax loss (non-log)                          0.76
             General FCC Limit (mw/cm 2)               f/1500




1/11/2019, 3:28 PM                                                    700 Band 13 UL


                Minimum Safe Distance From Antennas
               Based upon FCC OET Bulletin 65 and other FCC Sources


             INPUT DATA
             Frequency MHz                                869
             Pout Watts                               0.00331
             Duty Cycle Percent                       100.0%
             Ant. Gain dBi                               6.58
             Coax Loss dB                                0.00
             Distance From Antenna In cm                 20.3

             RESULTS OF CALCULATIONS
             Ant. Gain less Coax Loss dBi                6.58
             Distance From Antenna In Inches             8.00
             EIRP (Watts)                              0.0151
             FCC Power Density Limit (mw/cm2)            0.58
             Calculated Power Density (mw/cm2)         0.0029


             REFERENCE DATA
             Pout dBm                                     5.20
             Antenna Gain (non-log)                       4.55
             Coax loss (non-log)                          1.00
             General FCC Limit (mw/cm 2)               f/1500




1/11/2019, 3:28 PM                                                    800 Band DL


                Minimum Safe Distance From Antennas
               Based upon FCC OET Bulletin 65 and other FCC Sources


             INPUT DATA
             Frequency MHz                                824
             Pout Watts                               0.89125
             Duty Cycle Percent                       100.0%
             Ant. Gain dBi                               1.16
             Coax Loss dB                                1.34
             Distance From Antenna In cm                 20.3

             RESULTS OF CALCULATIONS
             Ant. Gain less Coax Loss dBi                -0.18
             Distance From Antenna In Inches              8.00
             EIRP (Watts)                              0.8561
             FCC Power Density Limit (mw/cm2)             0.55
             Calculated Power Density (mw/cm2)         0.1651


             REFERENCE DATA
             Pout dBm                                   29.50
             Antenna Gain (non-log)                       1.31
             Coax loss (non-log)                          0.74
             General FCC Limit (mw/cm 2)               f/1500




1/11/2019, 3:28 PM                                                    800 Band UL


                Minimum Safe Distance From Antennas
               Based upon FCC OET Bulletin 65 and other FCC Sources
             INPUT DATA


             Frequency MHz                               1930
             Pout Watts                               0.00324
             Duty Cycle Percent                       100.0%
             Ant. Gain dBi                               5.63
             Coax Loss dB                                0.00
             Distance From Antenna In cm                 20.3

             RESULTS OF CALCULATIONS
             Ant. Gain less Coax Loss dBi                5.63
             Distance From Antenna In Inches             8.00
             EIRP (Watts)                              0.0118
             FCC Power Density Limit (mw/cm2)            1.00
             Calculated Power Density (mw/cm2)         0.0023


             REFERENCE DATA
             Pout dBm                                    5.10
             Antenna Gain (non-log)                      3.66
             Coax loss (non-log)                         1.00
             General FCC Limit (mw/cm 2)                 1.00




1/11/2019, 3:29 PM                                                    1900 Band DL


                Minimum Safe Distance From Antennas
               Based upon FCC OET Bulletin 65 and other FCC Sources
             INPUT DATA


             Frequency MHz                               1850
             Pout Watts                               0.67608
             Duty Cycle Percent                       100.0%
             Ant. Gain dBi                               3.81
             Coax Loss dB                                2.31
             Distance From Antenna In cm                 20.3

             RESULTS OF CALCULATIONS
             Ant. Gain less Coax Loss dBi                1.51
             Distance From Antenna In Inches             8.00
             EIRP (Watts)                              0.9561
             FCC Power Density Limit (mw/cm2)            1.00
             Calculated Power Density (mw/cm2)         0.1844


             REFERENCE DATA
             Pout dBm                                   28.30
             Antenna Gain (non-log)                      2.40
             Coax loss (non-log)                         0.59
             General FCC Limit (mw/cm 2)                 1.00




1/11/2019, 3:29 PM                                                    1900 Band UL


                Minimum Safe Distance From Antennas
               Based upon FCC OET Bulletin 65 and other FCC Sources
             INPUT DATA


             Frequency MHz                               2110
             Pout Watts                               0.00316
             Duty Cycle Percent                       100.0%
             Ant. Gain dBi                               6.57
             Coax Loss dB                                0.00
             Distance From Antenna In cm                 20.3

             RESULTS OF CALCULATIONS
             Ant. Gain less Coax Loss dBi                6.57
             Distance From Antenna In Inches             8.00
             EIRP (Watts)                              0.0144
             FCC Power Density Limit (mw/cm2)            1.00
             Calculated Power Density (mw/cm2)         0.0028


             REFERENCE DATA
             Pout dBm                                    5.00
             Antenna Gain (non-log)                      4.54
             Coax loss (non-log)                         1.00
             General FCC Limit (mw/cm 2)                 1.00




1/11/2019, 3:29 PM                                                    2100 Band DL


                Minimum Safe Distance From Antennas
               Based upon FCC OET Bulletin 65 and other FCC Sources
             INPUT DATA


             Frequency MHz                               1710
             Pout Watts                               0.70795
             Duty Cycle Percent                       100.0%
             Ant. Gain dBi                               5.10
             Coax Loss dB                                3.95
             Distance From Antenna In cm                 20.3

             RESULTS OF CALCULATIONS
             Ant. Gain less Coax Loss dBi                1.15
             Distance From Antenna In Inches             8.00
             EIRP (Watts)                              0.9226
             FCC Power Density Limit (mw/cm2)            1.00
             Calculated Power Density (mw/cm2)         0.1780


             REFERENCE DATA
             Pout dBm                                   28.50
             Antenna Gain (non-log)                      3.24
             Coax loss (non-log)                         0.40
             General FCC Limit (mw/cm 2)                 1.00




1/11/2019, 3:30 PM                                                    1700 Band UL