MSCL

FCC ID: PWO460004

Cover Letter(s)

Download: PDF
FCCID_3109671

June 3, 2016



To: Whom it May Concern

Subject: Calculated Mobile Station Coupling Losses (MSCL) For FCCID: PWO460004

The following formulas were used to calculate MSCL with a 6 foot path loss
and a 45 degree polarity mismatch between the inside antenna and the mobile device:

Path Loss dB = 36.6 dB + 20Log(F MHz) dB+ 20Log(Dmiles) dB

Polarity Loss dB = 10Log(E1/E2)2 dB = PL dB
                                                                                                                45deg
PL dB= 10Log(E12/(E1Sin(45deg))2) dB = 20Log(1/Sin(45deg)) dB = 3.01dB
Where:
  E1 = Maximum Possible Magnitude of the Electric Field from the Mobile Device                             E2       E1
  E2 = Magnitude of the electric field from the Mobile device with a 45deg polarity mismatch = E1Sin(
  
MSCL dB = Path Loss dB + Polarity Loss dB - Antenna Gain dB

The results of the calculations are shown in the following table:

  Uplink Center Frequency MHz             707-710                782                836.5              1732.5         1880-1882.5
          Path Loss (dB)                   34.70                35.57               36.16               42.48            43.21
        Polarity Loss (dB)                   3                    3                   3                   3                3
  Antenna Gain with Coax Loss               2.13                2.13                2.12                5.09             7.49
            MSCL (dB)                      35.57                36.44               37.04               40.39            38.72



Note: Antenna Gain with Coax Loss as measured.



Sincerely