RF Exposure Info

FCC ID: PUU-CSWONBLXWF1

RF Exposure Info

Download: PDF
FCCID_4194441

                                          SGS-CSTC Standards Technical Services Co., Ltd.
                                          Guangzhou Branch

 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technological
 Development District, Guangzhou, China 510663
 Telephone: +86 (0) 20 82155555                                                        Report No.: GZEM181200012803
 Fax:       +86 (0) 20 82075059                                                        Page:       1 of 8
 Email:        ee.guangzhou@sgs.com
                                                                                       FCC ID: PUU-CSWONBLXWF1
1      Cover page


             RF Exposure Evaluation Report
Application No.:                               GZEM1812000128CR
Applicant:                                     GE Lighting
Address of Applicant:                          Nele park, Cleveland, OH 44112
Manufacturer:                                  GE Lighting
Address of Manufacturer:                       Nele park, Cleveland, OH 44112
Factory:                                       Nanchang Innotech Techonology Co.,Ltd
Address of Factory:                            No.399, Rule Lake Avenue, Nanchang Airport Economic Zone,
                                               Nanchang, China
Equipment Under Test (EUT):
FCC ID:                                 PUU-CSWONBLXWF1
EUT Name:                               Smart Switch
Model No.:                              CSWONBLPWF1, CSWONBLTWF1¤
 ¤                                      Please refer to section 4.1.3 of this report which indicates which model
                                        was actually tested and which were electrically identical.
 Trade Mark:                            GE
 Standard(s) :                          47 CFR Part 1, Subpart I 1.1310
 Date of Receipt:                       2018-12-26
 Date of Test:                          2019-01-14 to 2019-01-16
 Date of Issue:                         2019-03-01
 Test Result:                           Pass*
* In the configuration tested, the EUT complied with the standards specified above.




               Kobe Jian
         EMC Laboratory Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new
system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS
International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS
International Electrical Approvals in writing.


                             SGS-CSTC Standards Technical Services Co., Ltd
                             Guangzhou Branch.
                                                             Report No.: GZEM181200012803
                                                             Page:       2 of 8

Version

                                         Revision Record

  Version      Chapter            Date                Modifier            Remark

     01                         2019-03-01                                Original




  Authorized for issue by:




  Tested By
                                                                        2019-01-14 to 2019-01-16

                                Kevin_Zhang /Project Engineer           Date



  Checked By
                                                                         2019-01-18

                                Ricky Liu /Reviewer                     Date


                                                                  SGS—CSTC Standards Technical Services Co., Ltd
                                                                  Guangzhou Branch.

                                                                                                                                             Report No.: GZEM181200012803
                                                                                                                                             Page:                      3 of 8

2              Contents
                                                                                                                                                                                                                   Page

1            COVER PAGE                                                                                                                                                                                                   1

VERSION                                                                                                                                                                                                                   2

2            CONTENTS                                                                                                                                                                                                     3

3            GENERAL INFORMATION                                                                                                                                                                                          4
       3.1        GENERAL DESCRIPTION OF EUT ...122220222002222222rrsrserrsrrrrsssrrrrsrrrrssrrresssrrrssrrrsssrrrrssrrssrrrrsssrrr se rrsssrrr es s rr se se e es se errea e e ar e e k44
       3.2        TEST LOCATION...222222222222222rrrsrrrrssrrrrrsrrrsssrrrrssrrrrssrrssrrrsssrrrrssrrrssrrrrsssrrrssrrrsssrrrrssrrrsssrrrsssrrrssr e es es se e es se rr s se e e es se erree e e areea e es4
       3.3         TEST FACIMITY...220222202222222rrrssrrrrsssrrrssrrrsssrrrrssrrrrssrrssrrrsssrrrrssrrrssrrrrsssrrrssrrrsssrrrrssrrrsssrrrsssrrrssr e es es se e es se rr s se e e es s se e e ee e e areea e es 5
       3.4        DEVIATION FROM STANDARDS....22222222222022222226rrisrkksrrrrsssrrrrsrrrrssrrrrsssrrrssrrrsssrrrrssrrrssrrrrsssrrr se rrsssrrrrs s rr se se e es se errea e e ar e e k4 6
       3.5        ABNORMALITIES FROM STANDARD CONDITIONS ...22222222222222222222rrrissrrrrsrrrrsssrrrissrrrsssrrrsssrrrssrrrssssrrrs se rr s se e rre s se rrre e e arkekee4 6
       3.6        OTHER INFORMATION REQUESTED BY THE CUSTOMER ....222222222222222222¥¥rr¥srrssrrssssssrrrsrsrssrrssrrssrrrrrrrrrrrr e e e rrrrrerrrerar e k ees 6

4            RF EXPOSURE EVALUATION                                                                                                                                                                                       7

       4.1        RF EXPOSURE COMPLIANCE REQUIREMENT .......2.222222222222222¥¥2r¥srrrssrssrrsssrrssrsssrsssrssrrssrrrsrrrsrrrrrrr s se se se rree se rerrrererer e e ea es7
             4.1.1            LIMIIS .....0.22220000000022222vvvrrsssrrrrrrrrsssrrrrrrrrsssrrrrssssrrrrrrrssssrrrrrrrsssrrrrrrrrsssrrrrrrrrssssrrrrrrrssserrrrr es es se e e rrr es se se e er e e es se se e e en es 7
             4.1.2            T@St PFOC@UU@..........0.22200000000022222rrrrrrrsssrrrrsssrrrrrrrrssssrrrrrrrssssrrrrrrrsssrrrrrrrrsssrrrrrrrssssrrrrrrrrssserrrrr es se se e e er e es se e aaa e es 7
       4.1.3 EUT RF EXPOSURE EVALUATION...1222211222222222ssrrikrrrssssrrssrrrrssrrrrsssrrrssrrrssssrrrssrrrsssrrrsssrrrssrrrssssrrrsserrs se e e e es se e e se e es es eaaake es 8




                                                 Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                                 overleaf, available on request or accessible at http://www.sqs.com/en/Terms—and—Conditions.aspx and, for electronic format documents,
                                                 subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms—and—Conditions/Terms—e—Document.aspx.
                                                 Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is
                                                 advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                                                 Client‘s instructions, if any. The Company‘s sole responsibility               is to its Client and this document does not exonerate parties to a
                                                 transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                                                 except in full, without prior written approval of the Company. Any unauthorized alteration, for$ery or falsification of the content or
           *"L’Ffizflfl?fiii                §        appearance of this document is unlawful and offenders may be prosecuted to the fullest extent         the law. Unless otherwise stated the
         ‘gblnspectlon & Testing Services§       results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
                                                 Attention: To check the authenticity of testing /inspection report & certificate, please contact us at telephone (86—755) 8307 1443,
                                                 or email: CN.Doccheck@sqs.com
                     chnical@ Rgés Co.Ltd. No.198 Kezhu Road, Scientech Park, Guangzhou Economic &Technology Development District, Guangzhou, China 510663 t (86—20) 82155555 f (86—20) 82075058 www.sgsgroup.com.cn
    Guangzhou BrméerIESserfC Laboratory. TB °M —ZHERKIRTEAENEMEIR1OSS                                                                      MBZH: 510663 t (86—20) 82155555 f (86—20) 82075058 sgs.china@sgs.com
                                                 T
                                                                                                                                                                Member of the SGS Group (SGS SA)


                                  SGS-CSTC Standards Technical Services Co., Ltd
                                  Guangzhou Branch.
                                                                  Report No.: GZEM181200012803
                                                                  Page:       4 of 8

3        General Information

3.1 General Description of EUT
        Power Supply:              AC 120V 60Hz
        Test Voltage:              AC 120V 60Hz
        Cable:                     NA
WIFI:
        Antenna Gain               0.2dBi
        Antenna Type               Integrated PCB antenna
        Channel Spacing            5MHz
        Modulation Type            802.11b: DSSS (CCK, DQPSK, DBPSK)
                                   802.11g/n: OFDM (64QAM, 16QAM, QPSK, BPSK)
        Number of Channels         802.11b/g/n(HT20):11
                                   802.11n(HT40):7
        Operation Frequency        802.11b/g/n(HT20): 2412MHz to 2462MHz
                                   802.11n(HT40): 2422MHz to 2452MHz
BT:
        Antenna Gain               -0.06dBi
        Antenna Type               Integrated PCB antenna
        Channel Spacing            2MHz
        Modulation Type            GFSK
        Number of Channels         40
        Operation Frequency        2402MHz to 2480MHz



3.2 Test Location
        All tests were performed at:
         SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou Branch EMC Laboratory,
         198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District,
         Guangzhou, China 510663
        Tel: +86 20 82155555       Fax: +86 20 82075059


                                                SGS—CSTC Standards Technical Services Co., Ltd
                                                Guangzhou Branch.

                                                                                                                            Report No.: GZEM181200012803
                                                                                                                            Page:                      5 of 8



3.3 Test Facility
         The test facility is recognized, certified, or accredited by the following organizations:
         * NVLAP (Lab Code: 200611—0)
         SGS—CSTC Standards Technical Services Co., Ltd., Guangzhou EMC Laboratory is accredited by the
          National Voluntary Laboratory Accreditation Program (NVLAP/NIST). NVLAP Code: 200611—0.
         The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any
         agency of the Federal Government.
         * ACMA
         SGS—CSTC Standards Technical Services Co., Ltd., EMC Laboratory can also perform testing for the
         Australian C—Tick mark as a result of our NVLAP accreditation.
         e SGS UK(Certificate No.: 32), SGS—TUV SAARLAND and SGS—FIMKO
         Have approved SGS—CSTC Standards Technical Services Co., Ltd., EMC Laboratory as a supplier of
         EMC TESTING SERVICES and SAFETY TESTING SERVICES.
         *       CNAS (Lab Code: LO167)
         SGS—CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been assessed and in
         compliance with CNAS—CLO1:2006 accreditation criteria for testing laboratories (identical to
          ISO/IEC 17025:2005 General Requirements) for the Competence of Testing Laboratories.
         *       FCC Recognized 2.948 Listed Test Firm(Registration No.: 282399)
         SGS—CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been registered and fully
         described in a report filed with the (FCC) Federal Communications Commission. The acceptance
         letter from the FCC is maintained in our files. Registration 282399, May 31, 2002.
         *       FCC Recognized Accredited Test Firm(Registration No.: 486818)
         SGS—CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been accredited and fully
         described in a report filed with the (FCC) Federal Communications Commission. The acceptance
         letter from the FCC is maintained in our files. Designation Number: CN5016, Test Firm Registration
         Number: 486818, Jul 13, 2017.
         *       Industry Canada (Registration No.: 4620B—1)
         The 3m/10m Alternate Semi—anechoic chamber of SGS—CSTC Standards Technical Services Co.,
         Ltd., has been registered by Certification and Engineering of Industry Canada for radio equipment
         testing with Registration No. 4620B—1.
          ®©      VCCI (Registration No.: R—2460, C—2584, G—449 and T—1179)
         The 10m Semi—anechoic chamber and Shielded Room of SGS—CSTC Standards Technical Services
         Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures
         with Registration No.: R—2460, C—2584, G—449 and T—1179 respectively.
          ®       CBTL (Lab Code: TL129)
         SGS—CSTC Standards Technical Services Co., Ltd., E&E Laboratory has been assessed and fully
         comply with the requirements of ISO/IEC 17025:2005, the Basic Rules, IECEE 01 and Rules of
         procedure IECEE 02, and the relevant IECEE CB—Scheme Operational documents.




                               Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                               overleaf, available on request or accessible at http://www.sqs.com/en/Terms—and—Conditions.aspx and, for electronic format documents,
                               subject to Terms and Conditions for Electronic Documents at http://www.sqs.com/en/Terms—and— Conditions/Terms—e—Document.as px.
                               Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is
                               advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                               Client‘s instructions, if any. The Company‘s sole responsibility               is to its Client and this document does not exonerate parties to a
                               transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                               except in full, without prior written approval of the Company. Any unauthorized alteration, for%ery or falsification of the content or
   *“@i)[ta(filji%)ffig          appearance of this document is unlawful and offenders may be prosecuted to the fullest extent         the law. Unless otherwise stated the
  ‘&/\Inspectlon&Testmg
                    Services   results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days on!
                               Attention: To check the authenhcnty of testing /inspection report & certificate, please contact us at telephgne (86—755) 8307 1443,
                               or email: CN.Doccheck@sqs.co
                               . No.198 Kezhu Road, Scientech Park, Guangzhou Economlc&TechnoIogyDeveInpmentDlsmd Guangzhou, China 510663 t (86—20) 82155555 f (86—20) 82075058 www.sgsgroup.com.cn
                                   TB +JM —ZHEKRATEENEMENIR1OSS                                           MB&H: 510663 t (86—20) 82155555 f (86—20) 82075058 sgs.china@sgs.com
                               7
                                                                                                                                              Member of the SGS Group (SGS SA)


                   SGS-CSTC Standards Technical Services Co., Ltd
                   Guangzhou Branch.
                                             Report No.: GZEM181200012803
                                             Page:       6 of 8



3.4 Deviation from Standards
   None.

3.5 Abnormalities from Standard Conditions
   None.

3.6 Other Information Requested by the Customer
   None.


                                SGS-CSTC Standards Technical Services Co., Ltd
                                Guangzhou Branch.
                                                                      Report No.: GZEM181200012803
                                                                      Page:       7 of 8

4       RF Exposure Evaluation

4.1     RF Exposure Compliance Requirement
4.1.1 Limits
        According to FCC Part1.1310: The criteria listed in the following table shall be used to evaluate the
        environment impact of human exposure to radio frequency (RF) radiation as specified in part1.1307(b)




F= Frequency in MHz
Friis Formula
Friis transmission formula: Pd = (Pout*G)/(4* Pi * R 2)
Where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416

R = distance between observation point and center of the radiator in cm
Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power input to
the antenna, through the calculation, we will know the distance r where the MPE limit is reached.

4.1.2 Test Procedure
        Software provided by client enabled the EUT to transmit and receive data at lowest, middle and
        highest channel individually.


                               SGS-CSTC Standards Technical Services Co., Ltd
                               Guangzhou Branch.
                                                                    Report No.: GZEM181200012803
                                                                    Page:       8 of 8

4.1.3 EUT RF Exposure Evaluation
For WIFI
Antenna Gain: 0.2dBi
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.047 in linear scale.
Output Power Into Antenna & RF Exposure Evaluation Distance:


        Channel          Max Conducted           Output Power       Power Density       Limit    Result
                           Peak Output            to Antenna         at R = 20 cm
                          Power (dBm)                (mW)              (mW/cm2)

        2442MHz               23.05                 201.837             0.04205          1.0      PASS

For Bluetooth
Antenna Gain: -0.06dBi
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 0.986 in linear scale.
Output Power Into Antenna & RF Exposure Evaluation Distance:


        Channel          Max Conducted           Output Power       Power Density       Limit    Result
                           Peak Output            to Antenna         at R = 20 cm
                          Power (dBm)                (mW)              (mW/cm2)

        2442MHz                6.74                  4.721              0.00093          1.0      PASS

Note:
1. Refer to report No. GZEM181200012801 & GZEM181200012802 for EUT test Max Peak Output Power
   value. The distance r calculated from the Fries transmission formula is far greater than 20 cm separation
   requirement.
2. According to the declaration from the applicant, the electrical circuit design, layout, components used and
   internal wiring were identical for all models, with only difference on the button and LED indicator.
    The model CSWONBLPWF1 has one button and two white LED. The model CSWONBLTWF1 gas two
    buttons and one white LED. Model CSWONBLPWF1 and CSWONBLTWF1 have the same Wi-Fi and
    Bluetooth modules.
    Therefore only one model CSWONBLTWF1 was tested in this report.
3. The Bluetooth and WIFI will not simultaneous transmission at same channel.