1732171R-FCC-RF Exposure-C-Reach-CBYGEH001-V1.0-2017-07-04

FCC ID: PUU-CBYGEH001

RF Exposure Info

Download: PDF
FCCID_3463005

            RF Exposure Evaluation Declaration
            Product Name : C-Reach
            Model No.              : CBYGEH001
            FCC ID                 : PUU-CBYGEH001



      Applicant : GE Lighting
      Address : 1975 Noble Road Cleveland Ohio United States 44077




                Date of Receipt : Mar. 31st, 2017
                Test Date               : Mar. 31st, 2017~ Apr. 28th, 2017
                Issued Date             : Jun. 20th, 2017
                Report No.              : 1732171R-RF-US-P20V01
                Report Version : V1.0




The test results relate only to the samples tested.
The test results shown in the test report are traceable to the national/international standard through the
calibration of the equipment and evaluated measurement uncertainty herein.
This report must not be used to claim product endorsement by CNAS, TAF or any agency of the government.
The test report shall not be reproduced without the written approval of DEKRA Testing & Certification (Suzhou)
Co., Ltd.


Report No: 1732171R-RF-US-P20V01



                   Tes t R e p o r t C e r t i f i c a t i o n
                                                         Issued Date : Jun. 20th, 2017
                                                         Report No. : 1732171R-RF-US-P20V01




   Product Name          : C-Reach
   Applicant             : GE Lighting
   Address               : 1975 Noble Road Cleveland Ohio United States 44077
   Manufacturer          : GE Lighting
   Address               : 1975 Noble Road Cleveland Ohio United States 44077
   Model No.             : CBYGEH001
   FCC ID                : PUU-CBYGEH001
   Brand Name            : GE Lighting
   EUT Voltage           : AC 120V/60Hz
   Test Voltage          : AC 120V/60Hz
   Applicable Standard   : KDB 447498D01V06
                           FCC Part1.1310
   Test Result           : Complied
   Performed Location    : DEKRA Testing and Certification (Suzhou) Co., Ltd.
                                 No.99 Hongye Rd., Suzhou Industrial Park, Suzhou,
                                 215006, Jiangsu, China
                                 TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
                                 FCC Registration Number: 800392

     Documented By           :


                                           (Adm. Specialist: Kathy Feng)

     Reviewed By             :

                                            (Senior Engineer: Frank He )


     Approved By             :


                                        (Engineering Manager: Harry Zhao )




                                          Page: 2 of 4


 Report No: 1732171R-RF-US-P20V01


1. RF Exposure Evaluation

1.1. Limits

    According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate
    the environment impact of human exposure to radio frequency (RF) radiation as specified in
    1.1307(b)
    LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
                              Electric               Magnetic
                                                                   Power             Average
          Frequency           Field                  Field
                                                                   Density           Time
          Range (MHz)         Strength               Strength
                                                                   (mW/cm2)          (Minutes)
                              (V/m)                  (A/m)
          (A) Limits for Occupational/ Control Exposures
          300-1500            --                     --            F/300             6
          1500-100,000        --                     --            5                 6
          (B) Limits for General Population/ Uncontrolled Exposures
          300-1500            --                     --            F/1500            6
          1500-100,000        --                     --            1                 30
    F= Frequency in MHz


    Friis Formula
    Friis transmission formula: Pd = (Pout*G)/(4*pi*r2)


    Where
                                      2
    Pd = power density in mW/ cm
    Pout = output power to antenna in mW
    G = gain of antenna in linear scale
    Pi = 3.1416
    R = distance between observation point and center of the radiator in cm

                                          2
    Pd is the limit of MPE, 1 mW/cm . If we know the maximum gain of the antenna and the total
    power input to the antenna, through the calculation, we will know the distance r where the
    MPE limit is reached.




                                              Page: 3 of 4


 Report No: 1732171R-RF-US-P20V01


1.2. Test Procedure

      Software provided by client enabled the EUT to transmit and receive data at lowest, middle
      and highest channel individually.
      The temperature and related humidity: 18℃and 78% RH.


1.3. Test Result of RF Exposure Evaluation

Product                 :   C-Reach
Test Item               :   RF Exposure Evaluation
Test Site               :   AC-6


           Antenna Gain:
The maximum Gain measured in fully anechoic chamber is 2.35dBi for BLE, and 3.5dBi for Wifi
in linear scale.


           Power Density
Standlone modes:
                                                                        Power Density at   Limit of Power
                            Frequency Band              EIRP
     Test Mode                                                             R = 20 cm           Density
                                   (MHz)               (dBm)                       2                     2
                                                                           (mW/cm )           S(mW/cm )
          BLE                2400 ~ 2483.5              7.617               0.00115               1
          Wifi               2400 ~ 2483.5            20.824                0.02405               1


Simultaneous transmission:
                                                               Maximum       Limit of Power
                                       Frequency Range                                        Power Density
          Operation Mode                                        EIRP            Density
                                            (MHz)                                               S(mW/m2)
                                                                (dBm)           S(W/m2)
                 BLE                    2400 ~ 2483.5           7.617             10            0.00115
                 Wifi                   2400 ~ 2483.5           20.824            10            0.02405
                                   Simultaneous transmission                                     0.0252

                                                2
Note: The power density is 0.0252mW/cm for C-Reach without any other radio equipment.


                                                    The End




                                                Page: 4 of 4



Document Created: 2017-07-04 13:56:51
Document Modified: 2017-07-04 13:56:51

© 2024 FCC.report