Calibration Laboratory of                                                                                          Schweizerischer Kalibrierdienst
Schmid & Partner                                                                                                   Service suisse d‘étalonnage
   Engineering AG                                                                                                  Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                       Swiss Calibration Service


Accredited by the Swiss Accreditation Service (SAS)                                             Accreditation No.: SCS 108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreementfor the recognition of calibration certificates

Client       BV—ADT (Auden)                                                                     Certificate No: D1900V2—50022—Mar09

IVCALIBRATION CERTIFICATE                                                                                                                            |
 Object                                D1900V2 — SN: 5d022


 Calibration procedure(s)              QA CAL—O5.v7
                                       Calibration procedure for dipole validation kits




 Calibration date:                     March 17, 2009

 Condition of the calibrated item      In Tolerance


 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical forcalibration)


 Primary Standards                      ID #                      Cal Date (Calibrated by, Certificate No.)             Scheduled Calibration
 Power meter EPM—442A                   GB37480704                08—Oct—08 (No. 217—00898)                             Oct—09
 Power sensor HP 8481A                  US37292783                08—Oct—08 (No. 217—00898)                             Oct—09
 Reference 20 dB Attenuator             SN: 5086 (20g)            01—Jul—08 (No. 217—00864)                             Jul—09
 Type—N mismatch combination            SN: 5047.2 / 06327        01—Jul—08 (No. 217—00867)                             Jul—09
 Reference Probe ES3DV2                 SN: 3025                  28—Apr—08 (No. ES3—3025_Apr08)                        Apr—09
 DAE4                                   SN: 601                   07—Mar—09 (No. DAE4—601_Mar09)                        Mar—10


 Secondary Standards                    ID #                      Check Date (in house)                                 Scheduled Check
 Power sensor HP 8481A                  MY41092317                18—O0ct—02 (in house check Oct—07)                    In house check: Oct—09
 RF generator R&S SMT—06                100005                    4—Aug—99 (in house check Oct—07)                      In house check: Oct—09
 Network Analyzer HP 8753E              US37390585 $4206          18—O0ct—01 (in house check Oct—08)                    In house check: Oct—09



                                        Name             T                     Function                                 Signature


                                                                                                                                 [lse se
 Calibrated by:                         Jeton Kastrati                         Laboratory Technician



 Approved by:                           Katia Pokovic                          Technical Manager



                                                                                                                       Issued: March 18, 2009
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.



Certificate No: D1900V2—50022_Mar09                                   Page 1 of 9


Calibration Laboratory of                                                     5   Schweizerischer Kalibrierdienst
Schmid & Partner                                                                  Service suisse d‘étalonnage
  Engineering AG                                                                  Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                  S   Swiss Calibration Service



Accredited by the Swiss Accreditation Service (SAS)                           Accreditation No.: SCS 108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates


Glossary:
TSL                          tissue simulating liquid
ConvF                        sensitivity in TSL / NORM x.y,z
N/A                          not applicable or not measured

Calibration is Performed According to the Following Standards:
    a) IEEE Std 1528—2003, "IEEE Recommended Practice for Determining the Peak Spatial—
       Averaged Specific Absorption Rate (SAR) in the Human Head from Wireless
       Communications Devices: Measurement Techniques", December 2003
    b) CENELEC EN 50361, "Basic standard for the measurement of Specific Absorption Rate
         related to human exposure to electromagnetic fields from mobile phones (300 MHz — 3
         GHz), July 2001
    c) Federal Communications Commission Office of Engineering & Technology (FCC OET),
       "Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency
       Electromagnetic Fields; Additional Information for Evaluating Compliance of Mobile and
       Portable Devices with FCC Limits for Human Exposure to Radiofrequency Emissions",
       Supplement C (Edition 01—01) to Bulletin 65

Additional Documentation:
    d) DASY4/5 System Handbook

Methods Applied and Interpretation of Parameters:
   e Measurement Conditions: Further details are available from the Validation Report at the end
     of the certificate. All figures stated in the certificate are valid at the frequency indicated.
    e    Antenna Parameters with TSL: The dipole is mounted with the spacer to position its feed
         point exactly below the center marking of the flat phantom section, with the arms oriented
         paralle! to the body axis.
    e    Feed Point Impedance and Return Loss: These parameters are measured with the dipole
         positioned under the liquid filled phantom. The impedance stated is transformed from the
         measurement at the SMA connector to the feed point. The Return Loss ensures low
         reflected power. No uncertainty required.
    e    Electrical Delay: One—way delay between the SMA connector and the antenna feed point.
         No uncertainty required.
    e    SAR measured: SAR measured at the stated antenna input power.
    e    SAR normalized: SAR as measured, normalized to an input power of 1 W at the antenna
         connector.
    e    SAR for nominal TSL parameters: The measured TSL parameters are used to calculate the
         nominal SAR result.




Certificate No: D1900V2—54022_Mar0g                             Page 2 of 9


Measurement Conditions
    DASY system configuration, as far as not given on page 1.
      DASY Version                                              DASYS                                   V5.0

      Extrapolation                                    Advanced Extrapolation
      Phantom                                        Modular Flat Phantom V5.0

      Distance Dipole Center — TSL                              10 mm                                with Spacer
      Zoom Scan Resolution                                dx, dy, dz =5 mm
      Frequency                                          1900 MHz + 1 MHz



Head TSL parameters
    The following parameters and calculations were applied.
                                                                Temperature           Permittivity        Conductivity

      Nominal Head TSL parameters                                  22.0 °C               40.0              1.40 mho/m

      Measured Head TSL parameters                              (22.0 £ 0.2) °C       38.8 + 6 %        1.47 mhoim * 6 %
      Head TSL temperature during test                          (21.5 £0.2) °C            «n                     me+




SAR result with Head TSL

      SAR averaged over 1 cm‘ (1 g) of Head TSL                   condition
      SAR measured                                         250 mW input power                      10.2 mW /g

      SAR normalized                                          normalized to 1W                     40.8 mW / g
      SAR for nominal Head TSL parameters ‘                   normalized to 1W           39.4 mW / g £ 17.0 %(k=2)

      SAR averaged over 10 cm* (10 g) of Head TSL                Condition
      SAR measured                                         250 mW input power                      5.26 mW /g

      SAR normalized                                          normalized to 1W                     21.0 mW /g
      SAR for nominal Head TSL parameters ‘                   normalized to 1W           20.7 mW / g £ 16.5 % (k=2)




* Correction to nominal TSL parameters according to d), chapter "SAR Sensitivities"

Certificate No: D1900V2—50022_Mar0®                     Page 3 of 9


Body TSL parameters

     The following parameters and calculations were applied.
                                                                   Temperature        Permittivity        Conductivity
       Nominal Body TSL parameters                                    22.0 °C            53.3              1.52 mho/m

       Measured Body TSL parameters                               (22.0 £ 0.2) °C     55.1 + 6 %        1.55 mho/m + 6 %

       Body TSL temperature during test                           (21.5 £ 0.2) °C         m                      ———



SAR result with Body TSL

       SAR averaged over 1 cm* (1 g) of Body TSL                    Condition

       SAR measured                                           250 mW input power                   10.2 mW /g
       SAR normalized                                           normalized to 1W                   40.8 mW 1 g
       SAR for nominal Body TSL parameters *                    normalized to 1W          40.7 mW / g £ 17.0 % (k=2)

       SAR averaged over 10 cm* (10 g) of Body TSL                  condition
       SAR measured                                           250 mW input power                   5.39 mW / g
       SAR normalized                                           normalized to 1W                   21.6 mW / g
       SAR for nominal Body TSL parameters 2                    normalized to 1W          21.5 mW / g £ 16.5 % (k=2)




* Correction to nominal TSL parameters according to d), chapter "SAR Sensitivities"

Certificate No: D1900V2—50022_Mar09                        Page 4 of 9


Appendix

Antenna Parameters with Head TSL

      impedance, transformed to feed point                                           52.3 Q + 3.1 jQ

      Return Loss                                                                       —28.6 dB


Antenna Parameters with Body TSL

      Impedance, transformed to feed point                                           46.3 Q + 3.5 jQ

      Return Loss                                                                       —25.5 dB



General Antenna Parameters and Design

      Electrical Delay (one direction)                                                   1.196 ns


After long term use with 100W radiated power, only a slight warming of the dipole near the feedpoint can be measured.

The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the
second arm of the dipole. The antenna is therefore short—circuited for DC—signals.
No excessive force must be applied to the dipole arms, because they might bend or the soldered connections near the
feedpoint may be damaged.


Additional EUT Data

      Manufactured by                                                                    SPEAG
      Manufactured on                                                                August 29, 2002




Certificate No: D1900V2—5d022_Mar09                      Page 5 of 9


DASY5 Validation Report for Head TSL
                                                                                Date/Time: 17.03.2009 13:55:13

Test Laboratory: SPEAG, Zurich, Switzerland

DUT: Dipole 1900 MHz; Type: D1900V2; Serial: D1900V2 — SN:5d022

Communication System: CW; Frequency: 1900 MHz; Duty Cycle: 1:1
Medium: HSL U1O0 BB
Medium parameters used: £= 1900 MHz; o = 1.47 mho/m; s = 38.8; p = 1000 kg/m3
Phantom section: Flat Section
Measurement Standard: DASYS (IEEE/IEC)

DASYS5 Configuration:

        Probe: ES3DV2 — SN3025; ConvF(4.9, 4.9, 4.9); Calibrated: 28.04.2008

        Sensor—Surface: 3.4mm (Mechanical Surface Detection)

        Electronics: DAE4 Sn601; Calibrated: 07.03.2009

        Phantom: Flat Phantom 5.0 (front); Type: QDO0OP50AA; Serial: 100 1

        Measurement SW: DASY5, V5.0 Build 120; SEMCAD X Version 13.4 Build 45



Pin = 250 mW; dip = 10 mm, scan at 3.4mm/Zoom Scan (dist=3.4mm, probe Odeg)
(7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 92.8 V/m; Power Drift = 0.049 dB
Peak SAR (extrapolated) = 19.3 W/kg
SAR(I g) = 10.2 mW/g; SAR(10 g) = 5.26 mW/g
Maximum value of SAR (measured) = 12.1 mW/g

         dB
          0



         ~3.64



         —1.28


         —10.9



         —14.6



         —18.2



                     0 dB = 12.1ImW/g




Certificate No: D1900V2—5d022_Mar09                       Page 6 of 9


Impedance Measurement Plot for Head TSL



                                                                17 Mar 2009      1i:16:15
     [CHI) sii     1 U Fs           2: 52.283 0   3.0527 0   255.71 pH         1 200.000 000 MHz




                                                                                                   CH1 Markers
     Del
                                                                                                    1: 44.934 a
                                                                                                     ~16.878 a
     Cor                                                                                           1.80000 GHz




     fvg
     16




     CH2



                                                                                                   CH2 Markers

     Cor                                                                                           1:—14.764 dB
                                                                                                    1.80000 GHz




     Av
     :1.69




                 START 1 600.000 900 MHz                                 STOP 2 100.000 000 MHz




Certificate No: D1900V2—5d022_Mar09                      Page 7 of 9


DASY5 Validation Report for Body TSL
                                                                                Date/Time: 10.03.2009 13:13:16

est Laboratory: SPEAG, Zurich, Switzerland

DUT: Dipole 1900 MHz; Type: D1900V2; Serial: D1900V2 — SN:50022

Communication System: CW; Frequency: 1900 MHz; Duty Cycle: 1:1
Medium: MSL U10 BB
Medium parameters used: £ = 1900 MHz; o = 1.55 mho/m: & = 55.2; p = 1000 kg/m3
Phantom section: Flat Section
Measurement Standard: DASYS (IEEE/IEC)

DASY5 Configuration:

        Probe: ES3DV2 — SN3025; ConvF(4.5, 4.5, 4.5); Calibrated: 28.04.2008

        Sensor—Surface: 3.4mm (Mechanical Surface Detection)

        Electronics: DAE4 Sn601; Calibrated: 07.03.2009

        Phantom: Flat Phantom 5.0 (back); Type: QDOOOP50OAA; Serial: 1002

        Measurement SW: DASY5, V5.0 Build 120; SEMCAD X Version 13.4 Build 45


Pin = 250 mW; dip = 10 mm, scan at 3.4mm 2/Zoom Scan (dist=3.4mm, probe Odeg)
(7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 92.1 V/m; Power Drift =—8.7e—005 dB
Peak SAR (extrapolated) = 18 W/kg
SAR(1 g) = 10.2 mW/g; SAR(10 g) = 5.39 mW/g
Maximum value of SAR (measured) = 12.3 mW/g

         dB




                     0 dB = 12.3mW/g


Certificate No: D1900V2—5d022_Mar09                       Page 8 of 9


Impedance Measurement Plot for Body TSL


                                                                          10 Man 2009           @9:43:10
     (CHI) si1     1 U FS          3:46.316 a               3.5469 9   297.11 pH               1 900.000 000 MHz


     *                                 /
                                                                                                                   CH1 Markers
                                                                        w            \
     Del                                               £"       _ 71"A~                                             4t 38.974 a
                                                /            %  \       A                                             ~27.156 a
     fer                                   4                   Py* ~                                               1.75000 GHz
                                                                                                                    2 41.094 o
                                                                                                                     ~16,.909 a
                                           1                           ty                                          1.80000 GHz
                                               \                p#F7"°F~—~
                                                                 N\ 4    $
     Av                                            \    /         ,&             *
     16"                                            i         tm k/
                                           40               ~% if s
                                                                   Y


     CH2



                                                                                                                   CH2 Markers
                                                                                                                   1:—10,032 dB
     Cor                                                                                                           1.75000 6Hz
                                                                                                                   2:—13.750 dB
                                                                                                                    1.80000 GHz

     Aw
     16°



                 START 1 550.000 000 MHz                                                 STOP 2 100.000 oo MHz




Certificate No: D1900V2—5d022_Mard9                                Page 9 of 9



Document Created: 2009-09-07 16:29:09
Document Modified: 2009-09-07 16:29:09

© 2025 FCC.report