Test Report

FCC ID: PRDRX0H

Test Report

Download: PDF
FCCID_3236900

                                                                 TEST REPORT

                                             Report No.: 16080907HKG-001

                                               Acrox Technologies Co., Ltd.


                                                               Application
                                                                   For
                                                               Certification
                                                             (Original Grant)
                                                           (FCC ID: PRDRX0H)

                                                                      Transceiver




Prepared and Checked by:                                                                    Approved by:

                                                                                                                                Digitally signed by
                                                                                                                                Koo Wai Ip
                                                                                                                                Location: Intertek
                                                                                                                                Testing Services
Signed On File                                                                                                                  Hong Kong Ltd.

Lok Chi Hang, Wil                                                                           Koo Wai Ip
Assistant Engineer                                                                          Assistant Supervisor
                                                                                            Date: December 13, 2016




-   Intertek's standard Terms and Conditions can be obtained at our website http://www.intertek.com/terms/.
-   The test report only allows to be revised within the retention period unless further standard or the requirement was noticed.
-   This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and
    liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the
    agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and
    then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be
    approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the
    material, product, or service is or has ever been under an Intertek certification program.
-   © 2016 Intertek




                                                  Intertek Testing Services Hong Kong Ltd.
                                          2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                                Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


                     INTERTEK TESTING SERVICES



                        GENERAL INFORMATION


Grantee:                    Acrox Technologies Co., Ltd.
Grantee Address:            4F., No. 89, Minshan St.,
                            Neihu Dist., Taipei City,
                            Taiwan 114.
Contact Person:             Gavin Hsieh
Tel:                        +886 2 2796 5888
Fax:                        +886 2 2793 8999
e-mail:                     N/A
Manufacturer:               N/A
Manufacturer Address:       N/a
Brand Name:                 radioshack / ACROX
Model:                      2604623 / MRS
Description of EUT:         Receiver
Serial Number:              N/A
FCC ID:                     PRDRX0H
Date of Sample Submitted:   August 16, 2016
Date of Test:               August 16, 2016 to December 12, 2016
Report No.:                 16080907HKG-001
Report Date:                December 13, 2016
Environmental Conditions:   Temperature: +10 to 40°C
                            Humidity: 10 to 90%




Report No.: 16080907HKG-001                                        i
FCC ID: PRDRX0H


                              INTERTEK TESTING SERVICES



                               SUMMARY OF TEST RESULT


             TEST SPECIFICATION                                  REFERENCE                RESULTS
 Transmitter Power Line Conducted Emissions                        15.207                   Pass
 Radiated Emission
                                                                 15.249, 15.209              Pass
 Radiated Emission on the Bandedge
 Radiated Emission in Restricted Bands                                15.205                 Pass

The equipment under test is found to be complying with the following standards:
FCC Part 15, October 1, 2015 Edition




 Note: 1. The EUT uses a permanently attached antenna which, in accordance to section 15.203, is
          considered sufficient to comply with the pervisions of this section.
       2. Pursuant to FCC part 15 Section 15.215(c), the 20 dB bandwidth of the emission was contained
          within the frequency band designated (mentioned as above) which the EUT operated. The
          effects, if any, from frequency sweeping, frequency hopping, other modulation techniques and
          frequency stability over excepted variations in temperature and supply voltage were considered.



Report No.: 16080907HKG-001                                                                            ii
FCC ID: PRDRX0H


                                    INTERTEK TESTING SERVICES



                                               Table of Contents

1.0   General Description ......................................................................................... 1
  1.1  Product Description ........................................................................................ 1
  1.2  Related Submittal(s) Grants............................................................................ 1
  1.3  Test Methodology ........................................................................................... 1
  1.4  Test Facility .................................................................................................... 1

2.0   System Test Configuration.............................................................................. 2
  2.1   Justification ..................................................................................................... 2
  2.2   EUT Exercising Software ................................................................................ 2
  2.3   Special Accessories ....................................................................................... 2
  2.4   Measurement Uncertainty............................................................................... 2
  2.5   Support Equipment List and Description ......................................................... 2

3.0   Emission Results ............................................................................................. 3
  3.1  Field Strength Calculation ............................................................................... 3
  3.2  Radiated Emission Configuration Photograph ................................................ 4
  3.3  Radiated Emission Data ................................................................................. 4
  3.4  Conducted Emission Configuration Photograph ............................................. 4
  3.5  Conducted Emission Data .............................................................................. 4

4.0       Equipment Photographs................................................................................ 11

5.0       Product Labelling ........................................................................................... 11

6.0       Technical Specifications ............................................................................... 11

7.0       Instruction Manual ......................................................................................... 11

8.0   Miscellaneous Information ............................................................................ 12
  8.1   Radiated Emission on the Bandedge............................................................ 12
  8.2   Discussion of Pulse Desensitization ............................................................. 13
  8.3   Calculation of Average Factor....................................................................... 13
  8.4   Emissions Test Procedures .......................................................................... 15

9.0       Equipment List ............................................................................................... 19




Report No.: 16080907HKG-001                                                                                               iii
FCC ID: PRDRX0H


                          INTERTEK TESTING SERVICES

1.0   General Description

1.1   Product Description

      The Equipment Under Test (EUT) is a Transceiver (USB Dongle) for
      presenter operating from 2404-2478MHz with 1MHz channel spacing. The
      EUT is powered by 5VDC by USB port. After plugged the EUT to computer
      and paired with Presenter, the computer can be controlled for “Previous
      Page”, “Next Page”, “Scrolls Up/Down” by Presenter through EUT.

      The Model: MRS is the same as the Model: 2604623 in hardware aspect.
      The difference in model number and brand name serves as marketing
      strategy.

      Antenna Type: Internal, Integral

      For electronic filing, the brief circuit description is saved with filename: descri.pdf.


1.2   Related Submittal(s) Grants

      This is a single application for certification of a transceiver. The Certification
      procedure of transceiver for this transceiver (with FCC ID: PRDPR02) is being
      processed as the same time of this application.


1.3   Test Methodology

      Both AC mains line-conducted and radiated emission measurements were
      performed according to the procedures in ANSI C63.10 (2013). All radiated
      measurements were performed in an 3m Chamber. Preliminary scans were
      performed in the 3m Chamber only to determine worst case modes. All
      radiated tests were performed at an antenna to EUT distance of 3 meters,
      unless stated otherwise in the “Justification Section” of this Application.


1.4   Test Facility

      The 3m Chamber and conducted measurement facility used to collect the
      radiated data is located at Workshop No. 3, G/F., World-Wide Industrial Centre,
      43-47 Shan Mei Street, Fo Tan, Sha Tin, N.T., Hong Kong. This test facility and
      site measurement data have been placed on file with the FCC.




Report No.: 16080907HKG-001                                                           1 of 19
FCC ID: PRDRX0H


                         INTERTEK TESTING SERVICES

2.0   System Test Configuration

2.1   Justification

      The system was configured for testing in a typical fashion (as a customer would
      normally use it), and in the confines as outlined in ANSI C63.10 (2013).

      The device was powered by 5VDC by USB port.

      For maximizing emissions, the EUT was rotated through 360°, the antenna
      height was varied from 1 meter to 4 meters above the ground plane, and the
      antenna polarization was changed. This step by step procedure for maximizing
      emissions led to the data reported in Exhibit 3.0.

      The rear of unit shall be flushed with the rear of the table.

      The equipment under test (EUT) was configured for testing in a typical fashion
      (as a customer would normally use it). The EUT was mounted to a plastic stand
      if necessary and placed on the wooden turntable, which enabled the engineer to
      maximize emissions through its placement in the three orthogonal axes.


2.2   EUT Exercising Software

      There was no special software to exercise the device.           Once the unit is
      powered up, it transmits the RF signal continuously.


2.3   Special Accessories

      There are no special accessories necessary for compliance of this product.


2.4   Measurement Uncertainty

      When determining of the test conclusion, the Measurement Uncertainty of test
      has been considered.

      Uncertainty and Compliance - Unless the standard specifically states that
      measured values are to be extended by the measurement uncertainty in
      determining compliance, all compliance determinations are based on the actual
      measured value.


2.5   Support Equipment List and Description

      HP Notebook – ProBook 430
      (Provided by Intertek)




Report No.: 16080907HKG-001                                                    2 of 19
FCC ID: PRDRX0H


                          INTERTEK TESTING SERVICES

3.0   Emission Results

      Data is included of the worst case configuration (the configuration which resulted
      in the highest emission levels). A sample calculation, configuration photographs
      and data tables of the emissions are included.


3.1   Field Strength Calculation

      The field strength is calculated by adding the Antenna Factor and Cable Factor,
      and subtracting the Amplifier Gain (if any), Average Factor (optional) from the
      measured reading. The basic equation with a sample calculation is as follows:
      FS = RA + AF + CF - AG - AV
      where          FS = Field Strength in dBµV/m
                     RA = Receiver Amplitude (including preamplifier) in dBµV
                     CF = Cable Attenuation Factor in dB
                     AF = Antenna Factor in dB
                     AG = Amplifier Gain in dB
                     AV = Average Factor in dB

      In the following table(s), the reading shown on the data table reflects the preamplifier
      gain. An example for the calculations in the following table is as follows:
      FS = RR + LF
      where           FS = Field Strength in dBµV/m
                      RR = RA - AG - AV in dBµV
                      LF = CF + AF in dB

      Assume a receiver reading of 52.0 dBµV is obtained. The antenna factor of
      7.4 dB and cable factor of 1.6 dB are added. The amplifier gain of 29 dB and
      average factor of 5 dB are subtracted, giving a field strength of 27 dBµV/m.
      This value in dBµV/m was converted to its corresponding level in µV/m.

      RA = 52.0 dBµV/m
      AF = 7.4 dB                           RR = 18.0 dBµV
      CF = 1.6 dB                           LF = 9.0 dB
      AG = 29.0 dB
      AV = 5.0 dB
      FS = RR + LF
      FS = 18 + 9 = 27 dBµV/m

      Level in µV/m = Common Antilogarithm [(27 dBµV/m)/20] = 22.4 µV/m




Report No.: 16080907HKG-001                                                          3 of 19
FCC ID: PRDRX0H


                        INTERTEK TESTING SERVICES

3.2   Radiated Emission Configuration Photograph

      The worst case in radiated emission was found at 167.678 MHz

      For electronic filing, the worst case radiated emission configuration photographs
      are saved with filename: radiated photos.pdf.


3.3   Radiated Emission Data

      The data on the following page lists the significant emission frequencies, the
      limit and the margin of compliance. Numbers with a minus sign are below the
      limit.

      Judgment: Passed by 2.0 dB


3.4   Conducted Emission Configuration Photograph

      The worst case in line-conducted emission was found at 0.150 MHz

      For electronic filing, the worst case line-conducted configuration photographs
      are saved with filename: conducted photo.pdf.


3.5   Conducted Emission Data

      For electronic filing, the graph and data table of conducted emission is saved
      with filename: conducted.pdf.

      Judgment: Pass by 14.20 dB




Report No.: 16080907HKG-001                                                    4 of 19
FCC ID: PRDRX0H


                                 INTERTEK TESTING SERVICES

Applicant: Acrox Technologies Co., Ltd.                             Date of Test: December 12, 2016
Model: 2604623
Worst-Case Operating Mode: Data Transfer

                                                      RBW    9 kHz
                                                      MT     1 s
                                     Att 10 dB AUTO   PREAMP OFF
      dBµV    100                        1 MHz                           10 MHz


              90
                                                                                           SGL
      1 PK
      CLRWR
              80

      2 AV
      CLRWR                                                                                TDS
              70

              CF15MQP
              60

              CF15MAV
              50

                                                                                           6DB
              40                                                                           AC



              30



              20



              10




                              EDIT PEAK LIST (Final Measurement Results)
              Trace1:             CF15MQP
              Trace2:             CF15MAV
              Trace3:             ---
                      TRACE             FREQUENCY     LEVEL dBµV          DELTA LIMIT dB
              1     Quasi Peak    150 kHz              51.79   L1         -14.20
              2     CISPR Average150 kHz               35.83   N          -20.16
              1     Quasi Peak    226.5 kHz            41.93   L1         -20.64
              2     CISPR Average226.5 kHz             28.78   L1         -23.79
              1     Quasi Peak    357 kHz              36.01   N          -22.78
              2     CISPR Average379.5 kHz             26.78   L1         -21.50
              1     Quasi Peak    514.5 kHz            40.41   L1         -15.59
              2     CISPR Average541.5 kHz             28.97   N          -17.02
              1     Quasi Peak    568.5 kHz            32.50   N          -23.49
              2     CISPR Average573 kHz               20.28   N          -25.71
              1     Quasi Peak    1.0275 MHz           27.09   L1         -28.90
              1     Quasi Peak    2.949 MHz            28.82   N          -27.17
              1     Quasi Peak    3.03 MHz             27.35   N          -28.64




       Note: Measurement Uncertainty is ±4.2dB at a level of confidence of 95%.




Report No.: 16080907HKG-001                                                                      5 of 19
FCC ID: PRDRX0H


                              INTERTEK TESTING SERVICES

Applicant: Acrox Technologies Co., Ltd.                    Date of Test: December 12, 2016
Model: 2604623
Worst-Case Operating Mode: Transmitting
                                       Table 1
                                Radiated Emissions
                 Pursuant to FCC Part 15 Section 15.249 Requirement
Lowest Channel
                              Pre-Amp Antenna   Net at  Average Calculated   Average Limit
Polari- Frequency   Reading     Gain   Factor 3m - Peak Factor    at 3m          at 3m        Margin
zation     (MHz)    (dBμV)      (dB)    (dB)  (dBμV/m)    (dB)  (dBμV/m)       (dBμV/m)        (dB)
  V      2404.000    101.0       33     29.4     97.4    44.4      53.0           94.0        -41.0
  V      2400.000     52.9       33     29.4     49.3    44.4       4.9           54.0        -49.1
  V      4808.000    68.6        33     34.9    70.5     44.4     26.1           54.0         -27.9
  V      7212.000     54.7       33     37.9     59.6    44.4      15.2           54.0        -38.8
  V      9616.000     50.3       33     40.4     57.7    44.4      13.3           54.0        -40.7
  V     12020.000    51.3        33     40.5    58.8     44.4     14.4           54.0         -39.6
  V     14424.000     49.6       33     40.0     56.6    44.4      12.2           54.0        -41.8

                                    Pre-Amp    Antenna      Net at      Peak Limit
 Polari-   Frequency    Reading       Gain      Factor    3m - Peak       at 3m          Margin
 zation       (MHz)     (dBμV)        (dB)       (dB)     (dBμV/m)      (dBμV/m)          (dB)
   V        2404.000     101.0         33        29.4        97.4         114.0          -16.6
   V        2400.000     52.9          33        29.4        49.3          74.0          -24.7
   V        4808.000     68.6          33        34.9       70.5          74.0            -3.5
   V        7212.000     54.7          33        37.9        59.6          74.0          -14.4
   V        9616.000     50.3          33        40.4        57.7          74.0          -16.3
   V       12020.000     51.3          33        40.5       58.8          74.0           -15.2
   V       14424.000     49.6          33        40.0        56.6          74.0          -17.4

NOTES: 1. Peak Detector Data unless otherwise stated.

           2. All measurements were made at 3 meters. Harmonic emissions not
              detected at the 3-meter distances were measured at 0.3-meter and an
              inverse proportional extrapolation was performed to compare the signal
              level to the 3-meter limit. No other harmonic emissions than those
              reported were detected at a test distance of 0.3-meter.

           3. Negative sign in the column shows value below limit.

           4. Horn antenna is used for the emission over 1000MHz.

           5. Emission (the row indicated by bold italic) within the restricted band meets
              the requirement of FCC Part 15 Section 15.205.

           6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 16080907HKG-001                                                                  6 of 19
FCC ID: PRDRX0H


                              INTERTEK TESTING SERVICES

Applicant: Acrox Technologies Co., Ltd.                    Date of Test: December 12, 2016
Model: 2604623
Worst-Case Operating Mode: Transmitting
                                       Table 2
                                Radiated Emissions
                 Pursuant to FCC Part 15 Section 15.249 Requirement
Middle Channel
                              Pre-Amp Antenna   Net at  Average Calculated   Average Limit
Polari- Frequency   Reading     Gain   Factor 3m - Peak Factor    at 3m          at 3m        Margin
zation     (MHz)    (dBμV)      (dB)    (dB)  (dBμV/m)    (dB)  (dBμV/m)       (dBμV/m)        (dB)
  V      2441.000    101.4       33     29.4     97.8    44.4      53.4           94.0        -40.6
  V      4882.000    68.6        33     34.9    70.5     44.4     26.1           54.0         -27.9
  V      7323.000    54.7        33     37.9    59.6     44.4     15.2           54.0         -38.8
  V      9764.000     50.3       33     40.4     57.7    44.4      13.3           54.0        -40.7
  V     12205.000    51.3        33     40.5    58.8     44.4     14.4           54.0         -39.6
  V     14646.000     51.5       33     38.4     56.9    44.4      12.5           54.0        -41.5

                                    Pre-Amp    Antenna      Net at      Peak Limit
 Polari-   Frequency    Reading       Gain      Factor    3m - Peak       at 3m          Margin
 zation       (MHz)     (dBμV)        (dB)       (dB)     (dBμV/m)      (dBμV/m)          (dB)
   V        2441.000     101.4         33        29.4        97.8         114.0          -16.2
   V        4882.000     68.6          33        34.9       70.5          74.0            -3.5
   V        7323.000     54.7          33        37.9       59.6          74.0           -14.4
   V        9764.000     50.3          33        40.4        57.7          74.0          -16.3
   V       12205.000     51.3          33        40.5       58.8          74.0           -15.2
   V       14646.000     51.5          33        38.4        56.9          74.0          -17.1

NOTES: 1. Peak Detector Data unless otherwise stated.

           2. All measurements were made at 3 meters. Harmonic emissions not
              detected at the 3-meter distances were measured at 0.3-meter and an
              inverse proportional extrapolation was performed to compare the signal
              level to the 3-meter limit. No other harmonic emissions than those
              reported were detected at a test distance of 0.3-meter.

           3. Negative sign in the column shows value below limit.

           4. Horn antenna is used for the emission over 1000MHz.

           5. Emission (the row indicated by bold italic) within the restricted band meets
              the requirement of FCC Part 15 Section 15.205.

           6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 16080907HKG-001                                                                  7 of 19
FCC ID: PRDRX0H


                              INTERTEK TESTING SERVICES

Applicant: Acrox Technologies Co., Ltd.                    Date of Test: December 12, 2016
Model: 2604623
Worst-Case Operating Mode: Transmitting
                                       Table 3
                                Radiated Emissions
                 Pursuant to FCC Part 15 Section 15.249 Requirement
Highest Channel
                              Pre-Amp Antenna   Net at  Average Calculated   Average Limit
Polari- Frequency   Reading     Gain   Factor 3m - Peak Factor    at 3m          at 3m        Margin
zation     (MHz)    (dBμV)      (dB)    (dB)  (dBμV/m)    (dB)  (dBμV/m)       (dBμV/m)        (dB)
  V      2478.000    101.7       33     29.4     98.1    44.4      53.7           94.0        -40.3
  V      2483.500    53.4        33     29.4    49.8     44.4      5.4           54.0         -48.6
  V      4956.000    69.0        33     34.9    70.9     44.4     26.5           54.0         -27.5
  V      7434.000    55.0        33     37.9    59.9     44.4     15.5           54.0         -38.5
  V      9912.000     50.2       33     40.4     57.6    44.4      13.2           54.0        -40.8
  V     12390.000    51.2        33     40.5    58.7     44.4     14.3           54.0         -39.7
  V     14868.000     51.2       33     38.4     56.6    44.4      12.2           54.0        -41.8

                                    Pre-Amp    Antenna      Net at      Peak Limit
 Polari-   Frequency    Reading       Gain      Factor    3m - Peak       at 3m          Margin
 zation       (MHz)     (dBμV)        (dB)       (dB)     (dBμV/m)      (dBμV/m)          (dB)
   V        2478.000     101.7         33        29.4        98.1         114.0          -15.9
   V        2483.500     53.4          33        29.4       49.8          74.0           -24.2
   V        4956.000     69.0          33        34.9       70.9          74.0            -3.1
   V        7434.000     55.0          33        37.9       59.9          74.0           -14.1
   V        9912.000     50.2          33        40.4        57.6          74.0          -16.4
   V       12390.000     51.2          33        40.5       58.7          74.0           -15.3
   V       14868.000     51.2          33        38.4        56.6          74.0          -17.4

NOTES: 1. Peak Detector Data unless otherwise stated.

           2. All measurements were made at 3 meters. Harmonic emissions not
              detected at the 3-meter distances were measured at 0.3-meter and an
              inverse proportional extrapolation was performed to compare the signal
              level to the 3-meter limit. No other harmonic emissions than those
              reported were detected at a test distance of 0.3-meter.

           3. Negative sign in the column shows value below limit.

           4. Horn antenna is used for the emission over 1000MHz.

           5. Emission (the row indicated by bold italic) within the restricted band meets
              the requirement of FCC Part 15 Section 15.205.

           6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 16080907HKG-001                                                                  8 of 19
FCC ID: PRDRX0H


                         INTERTEK TESTING SERVICES

Applicant: Acrox Technologies Co., Ltd.              Date of Test: December 12, 2016
Model: 2604623
Worst-Case Operating Mode: Transmitting (USB)
                                      Table 4
                               Radiated Emissions
                Pursuant to FCC Part 15 Section 15.209 Requirement

                                      Pre- Antenna        Net        Limit
                Frequency   Reading   amp Factor         at 3m       at 3m     Margin
 Polarization     (MHz)     (dBμV)    (dB)  (dB)       (dBμV/m)    (dBμV/m)     (dB)
      V          143.346      40.4     16   14.0          38.4        43.5      -5.1
      V          167.678      39.5     16   18.0          41.5        43.5      -2.0
      H          228.785      38.6     16   18.0          40.6        46.0      -5.4
      H          240.348     39.7      16   19.0         42.7        46.0       -3.3
      H          251.565     39.8      16   20.0         43.8        46.0       -2.2
      H          264.456     36.9      16   21.0         41.9        46.0       -4.1
      H          276.345     34.5      16   22.0         40.5        46.0       -5.5
      H          300.345      36.1     16   22.0          42.1        46.0      -3.9
      H          604.233      26.9     16   29.0          39.9        46.0      -6.1

NOTES: 1. Peak Detector Data unless otherwise stated.

         2. All measurements were made at 3 meters. Harmonic emissions not
            detected at the 3-meter distances were measured at 0.3-meter and an
            inverse proportional extrapolation was performed to compare the signal
            level to the 3-meter limit. No other harmonic emissions than those
            reported were detected at a test distance of 0.3-meter.

         3. Negative sign in the column shows value below limit.

         4. Horn antenna is used for the emission over 1000MHz.

         5. Emission (the row indicated by bold italic) within the restricted band meets
            the requirement of FCC Part 15 Section 15.205.

         6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 16080907HKG-001                                                     9 of 19
FCC ID: PRDRX0H


                         INTERTEK TESTING SERVICES

Applicant: Acrox Technologies Co., Ltd.              Date of Test: December 12, 2016
Model: 2604623
Worst-Case Operating Mode: Normal Operation
                                      Table 5
                               Radiated Emissions
                Pursuant to FCC Part 15 Section 15.209 Requirement

                                      Pre- Antenna        Net        Limit
                Frequency   Reading   amp Factor         at 3m       at 3m     Margin
 Polarization     (MHz)     (dBμV)    (dB)  (dB)       (dBμV/m)    (dBμV/m)     (dB)
      V           43.565      30.4     16   10.0          24.4        40.0     -15.6
      V          123.675     27.5      16   14.0         25.5        43.5      -18.0
      V          243.776     23.6      16   20.0         27.6        46.0      -18.4
      V          334.354     20.7      16   24.0         28.7        46.0      -17.3
      H          645.345      16.8     16   29.0          29.8        46.0     -16.2
      H          756.565      13.7     16   30.0          27.7        46.0     -18.3

NOTES: 1. Peak Detector Data unless otherwise stated.

         2. All measurements were made at 3 meters. Harmonic emissions not
            detected at the 3-meter distances were measured at 0.3-meter and an
            inverse proportional extrapolation was performed to compare the signal
            level to the 3-meter limit. No other harmonic emissions than those
            reported were detected at a test distance of 0.3-meter.

         3. Negative sign in the column shows value below limit.

         4. Horn antenna is used for the emission over 1000MHz.

         5. Emission (the row indicated by bold italic) within the restricted band meets
            the requirement of FCC Part 15 Section 15.205.

         6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 16080907HKG-001                                                    10 of 19
FCC ID: PRDRX0H


                         INTERTEK TESTING SERVICES

4.0   Equipment Photographs

      For electronic filing, the photographs are saved with filename: external photos.pdf
      and internal photos.pdf.


5.0   Product Labelling

      For electronics filing, the FCC ID label artwork and the label location are saved
      with filename: label.pdf.


6.0   Technical Specifications

      For electronic filing, the block diagram and schematic of the tested EUT are
      saved with filename: block.pdf and circuit.pdf respectively.


7.0   Instruction Manual

      For electronic filing, a preliminary copy of the Instruction Manual is saved with
      filename: manual.pdf.

      This manual will be provided to the end-user with each unit sold/leased in the
      United States.




Report No.: 16080907HKG-001                                                     11 of 19
FCC ID: PRDRX0H


                        INTERTEK TESTING SERVICES

8.0   Miscellaneous Information

      The miscellaneous information includes details of the test procedure and
      measured bandwidth / calculation of factor such as pulse desensitization and
      averaging factor (calculation and timing diagram).


8.1   Radiated Emission on the Bandedge

      The test data of bandedge emissions were shown on the above radiated
      emissions table 1 and table 3 respectively.

      The resultant field strength meets the general radiated emission limit in
      Section 15.209, which does not exceed 74 dBµV/m (Peak Limit) and 54 dBµV/m
      (Average Limit).

      Emissions radiated outside of the specified frequency bands, except harmonics,
      are attenuated by 50dB below the level of the fundamental or to the general
      radiated emissions limits in Section 15.209, whichever is the lesser attenuation,
      which meet the requirement of part 15.249(d).




Report No.: 16080907HKG-001                                                   12 of 19
FCC ID: PRDRX0H


                        INTERTEK TESTING SERVICES

8.2   Discussion of Pulse Desensitization

      Pulse desensitivity is not applicable for this device. The effective period (Teff)
      is approximately 0.2 ms for a digital “1” bit which illustrated on technical
      specification, with a resolution bandwidth (3dB) of 1MHz, so the pulse
      desensitivity factor is 0dB.


8.3   Calculation of Average Factor

      The duty cycle is simply the on-time divided by the period:

      The duration of one cycle = 100ms

      Effective period of the cycle = 0.2*3 = 0.6ms

      DC = 0.6 / 100 = 0.006

      Therefore, the averaging factor is found by 20log 0.006 = -44.4dB.




Report No.: 16080907HKG-001                                                    13 of 19
FCC ID: PRDRX0H


                            INTERTEK TESTING SERVICES

     Average Factor
                                                        RBW 1 MHz    Delta 1 [T1 ]
                                                        VBW 3 MHz                0.08 dB
             Ref -5 dBm             * Att   10 dB       SWT 10 ms          200.000000 µs

                                                                     Marker 1 [T1 ]
             -10                                                               -18.83 dBm
                                                                             0.000000 s      B
             11                                                                             SGL
      1 PK   -20
      MAXH                                                                                  TRG

             -30
                                                                                            TDS


             -40
                    TRG -41.6 dBm                                                           PS


             -50



             -60                                                                            3DB
                                                                                            AC

             -70



             -80



             -90



             -100


             Center 2.406768 GHz                    1 ms/


                                                        RBW 1 MHz
                                                        VBW 3 MHz
             Ref -5 dBm             * Att   10 dB       SWT 100 ms


             -10
                                                                                             B
                                                                                            SGL
      1 PK   -20
      MAXH                                                                                  TRG

             -30
                                                                                            TDS


             -40
                    TRG -41.6 dBm                                                           PS


             -50



             -60                                                                            3DB
                                                                                            AC

             -70



             -80



             -90



             -100


             Center 2.406768 GHz                    10 ms/




Report No.: 16080907HKG-001                                                                       14 of 19
FCC ID: PRDRX0H


                          INTERTEK TESTING SERVICES

8.4   Emissions Test Procedures

      The following is a description of the test procedure used by Intertek Testing
      Services Hong Kong Ltd. in the measurements of transmitter operating under
      the Part 15, Subpart C rules.

      The transmitting equipment under test (EUT) is placed on a wooden turntable
      which is four feet in diameter and approximately 0.8m in height above the
      ground plane for emission measurement at or below 1GHz and 1.5m in height
      above the ground plane for emission measurement above 1GHz. During the
      radiated emissions test, the turntable is rotated and any cables leaving the EUT
      are manipulated to find the configuration resulting in maximum emissions. The
      EUT is adjusted through all three orthogonal axis to obtain maximum emission
      levels. The antenna height and polarization are also varied during the testing to
      search for maximum signal levels. The height of the antenna is varied from
      one to four meters.

      Detector function for radiated emissions is in peak mode. Average readings, when
      required, are taken by measuring the duty cycle of the equipment under test and
      subtracting the corresponding amount in dB from the measured peak readings. A
      detailed description for the calculation of the average factor can be found in Exhibit 8.3.

      The frequency range scanned is from the lowest radio frequency signal
      generated in the device which is greater than 9 kHz to the tenth harmonic of the
      highest fundamental frequency or 40 GHz, whichever is lower. For line
      conducted emissions, the range scanned is 150 kHz to 30 MHz.




Report No.: 16080907HKG-001                                                            15 of 19
FCC ID: PRDRX0H


                         INTERTEK TESTING SERVICES

8.4   Emissions Test Procedures (cont’d)

      The EUT is warmed up for 15 minutes prior to the test.

      AC power to the unit is varied from 85% to 115% nominal and variation in the
      fundamental emission field strength is recorded. If battery powered, a new,
      fully charged battery is used.

      Conducted measurements were made as described in ANSI C63.10 (2013).

      The IF bandwidth used for measurement of radiated signal strength was 100 kHz
      or greater when frequency is below 1000 MHz. Where pulsed transmissions of
      short enough pulse duration warrant, a greater bandwidth is selected according
      to the recommendations of Hewlett Packard Application Note 150-2. A discussion
      of whether pulse desensitivity is applicable to this unit is included in this report
      (See Exhibit 8.1). Above 1000 MHz, a resolution bandwidth of 1 MHz is used.

      Transmitter measurements are normally conducted at a measurement distance
      of three meters. However, to assure low enough noise floor in the forbidden
      bands and above 1 GHz, signals are acquired at a distance of one meter or less. All
      measurements are extrapolated to three meters using inverse scaling, unless
      otherwise reported. Measurements taken at a closer distance are so marked.




Report No.: 16080907HKG-001                                                     16 of 19
FCC ID: PRDRX0H


                       INTERTEK TESTING SERVICES

8.4.1 Radiated Emission Test Setup

      The figure below shows the test setup, which is utilized to make these
      measurements.


                                                       Antenna
                                          1.0~4.0m     Tower


                                     3m                     Receiver
                                                            Antenna
                        E
                        U
                        T




          0.8m

                 Ground Plane
       3m Chamber                             □

                                                      RF Test
                                                      Receiver

                 Test setup of radiated emissions up to 1GHz



                                                       Antenna
                                          1.0~4.0m     Tower


                                     3m                     Receiver
                        E
                                                            Antenna
                        U
                        T




          1.5m

                 Ground Plane
                                              □

                                                      RF Test Spectrum
                                                      Analyzer

              Test setup of radiated emissions above 1GHz




Report No.: 16080907HKG-001                                              17 of 19
FCC ID: PRDRX0H


                       INTERTEK TESTING SERVICES

8.4.2 Conducted Emission Test Procedures

      For tabletop equipment, the EUT along with its peripherals were placed on a
      1.0m(W)1.5m(L) and 0.8m in height wooden table. For floor-standing
      equipment, the EUT and all cables were insulated, if required, from the ground
      plane by up to 12 mm of insulating material. The EUT was adjusted to maintain
      a 0.4 meter space from a vertical reference plane. The EUT was connected to
      power mains through a line impedance stabilization network (LISN), which
      provided 50 ohm coupling impedance for measuring instrument and the chassis
      ground was bounded to the horizontal ground plane of shielded room. The
      excess power cable between the EUT and the LISN was bundled.

      All connecting cables of EUT and peripherals were moved to find the maximum
      emission.


8.4.3 Conducted Emission Test Setup

       AC Power
                     LISN 1           EUT             Peripherals          LISN 2




                     EMI
                   Receiver                                              AC Power




Report No.: 16080907HKG-001                                                18 of 19
FCC ID: PRDRX0H


                        INTERTEK TESTING SERVICES

9.0   Equipment List

1)    Radiated Emissions Test
 Equipment             EMI Test Receiver   Spectrum Analyzer        Double Ridged
                                                                    Guide Antenna
 Registration No.         EW-3095             EW-2188                 EW-1133
 Manufacturer                 R&S           AGILENTTECH                 EMCO
 Model No.                   ESCI              E4407B                    3115
 Calibration Date        Oct. 25, 2016       Apr. 25, 2016          Nov. 05, 2015
 Calibration Due Date    Oct. 25, 2017       Apr. 25, 2017          May 05, 2017

 Equipment                 Biconical            Log Periodic       Pyramidal Horn
                           Antenna                Antenna             Antenna
 Registration No.          EW-0571                EW-0446             EW-0905
 Manufacturer               EMCO                   EMCO                EMCO
 Model No.                  3104C                    3146             3160-09
 Calibration Date        May 18, 2016           Jul. 15, 2016       Feb. 12, 2016
 Calibration Due Date    Nov. 18, 2017          Jan. 15, 2018       Aug. 12, 2017

2)     Conducted Emissions Test
 Equipment                  EMI Test Receiver                       LISN
 Registration No.               EW-2500                           EW-2501
 Manufacturer                     R&S                               R&S
 Model No.                        ESCI                            ENV-216
 Calibration Date             Jan. 28, 2016                     Jan. 28, 2016
 Calibration Due Date         Jan. 28, 2017                     Jan. 28, 2017

3)     Average Factor Measurement
 Equipment                  Spectrum Analyzer
 Registration No.               EW-2329
 Manufacturer                      R&S
 Model No.                        FSP3
 Calibration Date             Aug. 26, 2016
 Calibration Due Date         Aug. 26, 2017




                           END OF TEST REPORT




Report No.: 16080907HKG-001                                                     19 of 19
FCC ID: PRDRX0H



Document Created: 2017-12-19 23:53:38
Document Modified: 2017-12-19 23:53:38

© 2024 FCC.report