Test Report

FCC ID: PR4ACU3SOLOX

Test Report

Download: PDF
FCCID_2554102

                                                FCC PART 18
                                              TEST REPORT
                                                              For

 Whirlpool Microwave Products Development Limited
                   16/F, Paliburg Plaza 68 Yee Woo Street, Causeway Bay, Hong Kong


                                      FCC ID: PR4ACU3SOLOX


              Report Type:                                        Product Type:
              Class II Permissive Change                          Microwave Oven



                    Test Engineer:        Joson Xiao


                 Report Number:           RSZ141208552-00


                      Report Date:        2015-01-29
                                          Dick Zhang

                     Reviewed By:         EMC Leader

                     Prepared By:         Bay Area Compliance Laboratories Corp. (Shenzhen)
                                          6/F, the 3rd Phase of WanLi Industrial Building,
                                          ShiHua Road, FuTian Free Trade Zone
                                          Shenzhen, Guangdong, China
                                          Tel: +86-755-33320018
                                          Fax: +86-755-33320008
                                          www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the equipment described herein. It may not be duplicated
or used in part without prior written consent from Bay Area Compliance Laboratories Corp.


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                                            Report No.: RSZ141208552-00




                                                       TABLE OF CONTENTS


GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................4
OPERATING CONDITION/TEST CONFIGURATION ..........................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................5
  EXTERNAL CABLE LIST AND DETAILS .........................................................................................................................5
  CONFIGURATION OF TEST SETUP .................................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................6
CONDUCTED EMISSIONS ........................................................................................................................................7
 APPLICABLE STANDARD ..............................................................................................................................................7
 MEASUREMENT UNCERTAINTY ....................................................................................................................................7
 EUT SETUP ..................................................................................................................................................................7
 EMI TEST RECEIVER SETUP .........................................................................................................................................8
 TEST PROCEDURE ........................................................................................................................................................8
 TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................8
 TEST RESULTS SUMMARY ............................................................................................................................................8
 TEST DATA ..................................................................................................................................................................9
RADIATION HAZARD MEASUREMENT .............................................................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  TEST DATA ................................................................................................................................................................11
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................11
  RADIATION HAZARD MEASUREMENT ........................................................................................................................11
  INPUT POWER .............................................................................................................................................................12
  LOAD FOR MICROWAVE OVENS .................................................................................................................................12
  RF OUTPUT POWER MEASUREMENT ..........................................................................................................................12
  OPERATING FREQUENCY MEASUREMENT ..................................................................................................................14
RADIATED EMISSIONS ...........................................................................................................................................16
  APPLICABLE STANDARD ............................................................................................................................................16
  MEASUREMENT UNCERTAINTY ..................................................................................................................................16
  EUT SETUP ................................................................................................................................................................16
  EMI TEST RECEIVER SETUP AND SPECTRUM ANALYZER SETUP................................................................................17
  TEST PROCEDURE ......................................................................................................................................................17
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................18
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................18
  TEST RESULTS SUMMARY ..........................................................................................................................................18
  TEST DATA AND PLOTS ..............................................................................................................................................19




FCC Part 18                                                                                                                                             Page 2 of 19


Bay Area Compliance Laboratories Corp. (Shenzhen)                                Report No.: RSZ141208552-00

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)
The Whirlpool Microwave Products Development Limited’s product, model number: WMH73521 (FCC ID:
PR4ACU3SOLOX) or the “EUT” in this report is a Microwave Oven, which was measured approximately:
76.0 cm (L) x 43.5 cm (W) x 47.1 cm (H), the rated with input voltage: AC 120V/60Hz. The operating
frequency is 2450 MHz.

*All measurement and test data in this report was gathered from production sample serial number: 1412003
(Assigned by BACL, Shenzhen). The EUT supplied by the applicant was received on 2014-10-15.


Objective
This report is prepared on behalf of Whirlpool Microwave Products Development Limited. in accordance
with Part 2-Subpart J, and Part 18-Subparts A, B and C of the Federal Communication Commissions rules
and regulations.

The objective of the manufacturer is to determine the EUT of compliance with FCC Part 18 limits.

This is the CIIPC application of the device. The difference between the original device and the current one
is as follows:

1. Changing the magnetron, the original magnetron is Panasonic LG-2M226, and the current one is
Toshiba LG-2M226.
2. Changing the high voltage transformer, the original high voltage transformer is Eledex/EDX-JK1016A-
3T, and the current one is YunLu/YL-1011AHEP-1.
3. Besides the high voltage transformer and magnetron change, the layout of PCB is changed as well.

For the changes made to the device, all the test items were performed.


Related Submittal(s)/Grant(s)
No related submittal(s).


Test Methodology
All measurements contained in this report were conducted with MP-5, FCC Methods of Measurements of
Radio Noise Emissions from ISM Equipment, February 1986. All measurements were performed at Bay
Area Compliance Laboratory Corporation. The radiated testing was performed at an antenna-to-EUT
distance of 3 meters.




FCC Part 18                                                                                       Page 3 of 19


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ141208552-00

Test Facility

The test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located on
the 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen,
Guangdong, China.

Test site at Bay Area Compliance Laboratories Corp. (Shenzhen) has been fully described in reports
submitted to the Federal Communication Commission (FCC). The details of these reports have been
found to be in compliance with the requirements of Section 2.948 of the FCC Rules on December 06, 2010.
The facility also complies with the radiated and AC line conducted test site criteria set forth in ANSI
C63.4-2009.

The Federal Communications Commission has the reports on file and is listed under FCC Registration No.:
382179. The test site has been approved by the FCC for public use and is listed in the FCC Public Access
Link (PAL) database.




FCC Part 18                                                                                  Page 4 of 19


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ141208552-00

OPERATING CONDITION/TEST CONFIGURATION
Justification
The EUT was operated at maximum (continuous) RF output power. The loads consisted of water in a glass
beaker in the amounts specified in the test procedure.


Equipment Modifications
No modifications were made to the EUT tested.


Support Equipment List and Details


   Manufacturer       Description           Model              Serial Number                  Remark

        N/A              Socket              N/A                      140217                   N/A


External Cable List and Details

              Cable Description                 Length (m)       From/Port                    To

      Un-shielding Un-detachable AC Cable           0.9                EUT                  Socket
      Un-shielding Un-detachable AC Cable           1.0                Mains                Socket


Configuration of Test Setup




                                                             Socket




FCC Part 18                                                                                   Page 5 of 19


Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: RSZ141208552-00


Block Diagram of Test Setup

                                                                                                     Mains


                                                             EUT             Socket
                                                                   10 cm

                                                                            Receptacle




                                                                                         1.0 Meter
                  Non-conductive table
                  80 cm above Ground Plane


                                                1.5 Meters




FCC Part 18                                                                                          Page 6 of 19


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ141208552-00

CONDUCTED EMISSIONS
Applicable Standard
FCC §18.307


Measurement Uncertainty
Input quantities to be considered for conducted disturbance measurements maybe receiver reading,
attenuation of the connection between LISN and receiver, LISN voltage division factor, LISN VDF
frequency interpolation and receiver related input quantities, etc.

Based on CISPR 16-4-2:2011, the expended combined standard uncertainty of conducted disturbance test
at Bay Area Compliance Laboratories Corp. (Shenzhen) is shown as below. And the uncertainty will not
be taken into consideration for the test data recorded in the report

                          Port                        Expanded Measurement uncertainty
                       AC Mains                       3.26 dB (k=2, 95% level of confidence)
                         CAT 3                        3.70 dB (k=2, 95% level of confidence)
                         CAT 5                        3.86 dB (k=2, 95% level of confidence)
                         CAT 6                        4.64 dB (k=2, 95% level of confidence)


EUT Setup




FCC Part 18                                                                                    Page 7 of 19


Bay Area Compliance Laboratories Corp. (Shenzhen)                                     Report No.: RSZ141208552-00

The setup of EUT is according with MP-5: 1986 measurement procedure. Specification used was with the
FCC Part 18.

The socket was connected to a 120 VAC/ 60Hz power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                                Frequency Range                             IF B/W
                                150 kHz – 30 MHz                             9 kHz

Test Procedure
Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All final data was recorded in the Quasi-peak and average detection mode.


Test Equipment List and Details

                                                                            Serial     Calibration   Calibration
      Manufacturer              Description             Model
                                                                           Number         Date        Due Date
     Rohde & Schwarz        EMI Test Receiver          ESCS30            100176        2014-06-03    2015-06-03
                                                                      3560.6650.12-
     Rohde & Schwarz               LISN                ENV216                          2014-06-09    2015-06-09
                                                                       101613-Yb
     Rohde & Schwarz         Transient Limiter         ESH3Z2           DE25985        2014-05-14    2015-05-14
     Rohde & Schwarz               LISN               ESH3-Z5              100113         NCR           NCR
     Rohde & Schwarz          CE Test software         EMC 32              V8.53.0        NCR           NCR

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
  been performed in accordance to requirements, traceable to National Primary Standards and International System
  of Units (SI).


Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC PART 18, the worst
margin reading as below:


                           12.6 dB at 0.158000 MHz in the Line conducted mode


Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level complies with the limit if

                                              Lm + U(Lm) ≤ Llim + Ucispr

In BACL, U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.


FCC Part 18                                                                                          Page 8 of 19


Bay Area Compliance Laboratories Corp. (Shenzhen)                                               Report No.: RSZ141208552-00

Test Data
     Environmental Conditions

                 Temperature:                      23 ℃
       Relative Humidity:                           52 %
          ATM Pressure:                           100.0 kPa

    The testing was performed by Joson Xiao on 2014-12-18.

    Test Mode: The max fan speed, max brightness and max output power

      AC 120V/60Hz, Line:

                                                              EMI Auto Test L


                          90

                          80

                          70
                                                                                                                  QP
                          60
                                                                                                                  AV
           Level in dBμ




                          50

                          40

                          30

                          20

                          10

                          0
                          150k    300   400 500      800 1M          2M       3M   4M 5M 6     8 10M      20M     30M
                                                                 Frequency in Hz



                                 Corrected          Correction
         Frequency                                                     Limit           Margin            Detector
                                 Amplitude           Factor
           (MHz)                                                      (dBμV)            (dB)           (PK/Ave./QP)
                                  (dBμV)              (dB)
          0.158000                  52.9               19.2            65.6             12.6               QP
          0.158000                  41.6               19.2            55.6             14.0               Ave.
          0.221500                  44.8               19.3            62.8             18.0               QP
          0.221500                  32.0               19.3            52.8             20.8               Ave.
          0.253500                  43.7               19.3            61.6             18.0               QP
          0.253500                  32.6               19.3            51.6             19.0               Ave.
          0.254500                  43.5               19.3            61.6             18.1               QP
          0.254500                  32.6               19.3            51.6             19.0               Ave.
          0.569330                  38.2               19.3            56.0             17.8               QP
          0.569330                  30.8               19.3            46.0             15.2               Ave.
          0.620790                  36.9               19.3            56.0             19.1               QP
          0.620790                  29.4               19.3            46.0             16.6               Ave.

FCC Part 18                                                                                                       Page 9 of 19


Bay Area Compliance Laboratories Corp. (Shenzhen)                                             Report No.: RSZ141208552-00


      AC 120V/60Hz, Neutral:

                                                            EMI Auto Test N


                          90

                          80

                          70
                                                                                                                QP
                          60
                                                                                                                AV
           Level in dBμ




                          50

                          40

                          30

                          20

                          10

                          0
                          150k    300   400 500    800 1M          2M       3M   4M 5M 6     8 10M       20M    30M
                                                               Frequency in Hz



                                 Corrected        Correction
         Frequency                                                   Limit          Margin             Detector
                                 Amplitude         Factor
           (MHz)                                                    (dBμV)           (dB)            (PK/Ave./QP)
                                  (dBμV)            (dB)
          0.181500                 49.0              19.2            64.4            15.4                QP
          0.181500                 37.2              19.2            54.4            17.2                Ave.
          0.197500                 43.1              19.2            63.7            20.6                QP
          0.197500                 29.6              19.2            53.7            24.1                Ave.
          0.274500                 36.8              19.2            61.0            24.2                QP
          0.274500                 24.4              19.2            51.0            26.6                Ave.
          0.309290                 39.8              19.2            60.0            20.2                QP
          0.309290                 29.3              19.2            50.0            20.7                Ave.
          0.470890                 32.9              19.2            56.5            23.6                QP
          0.470890                 23.1              19.2            46.5            23.4                Ave.
          0.597030                 35.5              19.2            56.0            20.5                QP
          0.597030                 29.2              19.2            46.0            16.8                Ave.

Note:
1) Corrected Amplitude = Reading + Correction Factor
2) Correction Factor =LISN VDF (Voltage Division Factor) + Cable Loss + Transient Limiter
3) Margin = Limit – Corrected Amplitude




FCC Part 18                                                                                                     Page 10 of 19


Bay Area Compliance Laboratories Corp. (Shenzhen)                                Report No.: RSZ141208552-00

RADIATION HAZARD MEASUREMENT
Applicable Standard
FCC §18.301


Test Data
     Environmental Conditions

              Temperature:              23 ℃
       Relative Humidity:               52 %
          ATM Pressure:               100.0 kPa

    The testing was performed by Joson Xiao on 2014-12-18.


Test Equipment List and Details

                                                                     Serial        Calibration    Calibration
    Manufacturer               Description            Model
                                                                    Number            Date         Due Date
   Rohde & Schwarz           Signal Analyzer         FSIQ26        8386001028      2014-11-12      2015-11-12
      GW Instek                Power Meter          CL110034      1937A01046       2014-04-24      2015-04-24
      A.H.System              Horn Antenna        SAS-200/571          135         2012-02-11      2015-02-10
          MC                  Thermometer              N/A             N/A         2014-11-01      2015-11-01
                             Microwave Survey
        Holaday                                      HI-1501           N/A         2014-11-01      2015-11-01
                                  Meter

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
  been performed in accordance to requirements, traceable to National Primary Standards and International System
  of Units (SI).


Radiation Hazard Measurement
Radiation leakage was measured in the as-received condition with the oven door closed using a microwave
leakage meter.

A 275 mL water load was placed in the center of the oven and the oven was operated at maximum output
power.

   There was no microwave leakage exceeding a power level of 0.05 mW/cm2 observed at any point 5 cm
or more from the external surface of the oven.

A maximum of 1.0 mW/cm2 is allowed in accordance with the applicable Federal Standards. Hence,
microwave leakage in the as-received condition with the oven door closed was below the maximum
allowed.




FCC Part 18                                                                                        Page 11 of 19


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ141208552-00

Input Power
Input power and current was measured using a power analyzer. A 1000 mL water load was placed in the
center of the oven and the oven was operated at maximum output power. A 1000mL water load was
chosen for its compatibility with the procedure commonly used by manufacturers to determine their input
ratings.

           Input Voltage        Input Current       Measured Input Power        Rated Input Power
             (VAC/Hz)              (Amps)                 (Watts)                    (Watts)
                 120                  15.48                  1857.6                     1800

    Based on the measured input power, the EUT was found to be operating within the intended
specifications.


Load for Microwave Ovens
For all measurements, the energy developed by the oven was absorbed by a dummy load consisting of a
quantity of tap water in a beaker. If the oven was provided with a shelf or other utensil support, this
support was in its initial normal position. For ovens rated at 1000 watts or less power output, the beaker
contained quantities of water as listed in the following subparagraphs. For ovens rated at more than 1000
watts output, each quantity was increased by 50% for each 500watts or fraction thereof in excess of 1000
watts. Additional beakers were used if necessary.
● Load for power output measurement: 1000 milliliters of water in the beaker located in the center of the
oven.
● Load for frequency measurement: 1000 milliliters of water in the beaker located in the center of the oven.
● Load for measurement of radiation on second and third harmonic: Two loads, one of 700 and the other
of 300 milliliters, of water are used. Each load is tested both with the beaker located in the center of the
oven and with it in the right front corner.


The RF output power is rated at 1000 watts

     Load used for power output measurement = 1000 milliliters of water
     Load used for frequency measurement = 1000 milliliters of water
     Load used for harmonic measurement = 700 & 300 milliliters of water
     Load used for other measurement = 700 milliliters of water


RF Output Power Measurement
A cylindrical container of borosilicate glass is used for the test. It has a maximum thickness of 3 mm, an
external diameter of approximately 190 mm and a height of approximately 90 mm. The mass of the
container is determined.

At the start of the test, the oven and the empty container are at ambient temperature. Water having an
initial temperature of 10 ºC ± 1 ºC C is used for the test. The water temperature is measured immediately
before it is poured into the container.

A quantity of 1 000 g ± 5 g of water is added to the container and its actual mass obtained. The container is
then immediately placed in the centre of the oven shelf, which is in its lowest normal position. The oven is
operated and the time for the water temperature to attain 20 ºC ± 2 ºC is measured. The oven is then
switched off and the final water temperature is measured within 60 s.

FCC Part 18                                                                                     Page 12 of 19


Bay Area Compliance Laboratories Corp. (Shenzhen)                         Report No.: RSZ141208552-00


              mw               mc           T0             T1             T2              t
              (g)              (g)         (ºC)           (ºC)           (ºC)            (s)
          1000                377.0        24.0           10.0           21.0            48

RF Output Power = (4.187x_1000 x( 21.0 –10)+0.55x377x( 21.0 - 24.0 )) / _48_= 946.56 Watts
P    is the microwave power output, in watts;
mw is the mass of the water, in grams;
mc   is the mass of the container, in grams;
To   is the ambient temperature, in degrees Celsius;
T1   is the initial temperature of the water, in degrees Celsius;
T2   is the final temperature of the water, in degrees Celsius;
t    is the heating time, in seconds, excluding the magnetron filament heating-up time.

   The measurement output power was found to be less than 500 watts. Therefore, in accordance with
Section 18.305 of Subpart-C, the measured out-of-band emissions were compared to the limit of
25μV/meter at a 300-meter measurement distance.

    The measured output power was found to exceed 500 watts. Therefore, in accordance with Section
18.305 of Subpart-C, the measured out-of-band emissions were compared with the limit calculated as
following:

                      LFS = 25*SQRT (Power Output/500)

                      LFS = 25*SQRT 946.56 /500)

                      LFS = 34.40

Where: LFS is the maximum allowable field strength for out-of-band emissions in μV/meter at a 300-
meter measurement distance. Power Output is the measured output power in watts.

                       LFS
                                          dBμV/m@300m                  dBμV/m@3m
                    μV/m@300m

                      34.40                       30.73                    70.73




FCC Part 18                                                                               Page 13 of 19


Bay Area Compliance Laboratories Corp. (Shenzhen)                                          Report No.: RSZ141208552-00

Operating Frequency Measurement
    Variation in Operating Frequency with Time

The operating frequency was measured using a spectrum analyzer. Starting with the EUT at room
temperature, a 1000mL water load was placed in the center of the oven and the oven was operated at
maximum output power. The fundamental operating frequency was monitored until the water load was
reduced to 20 percent of the original load.

The results of this test are as follows:

                            Low Frequency                                 High Frequency
                               (MHz)                                          (MHz)

                                 2413.03                                        2475.95

Refer to data pages for details of the variation in operating frequency with time measurement.

                                           Marker 2 [T1]          RBW   1 MHz       RF Att     40 dB
                          Ref Lvl                   68.40 dB V   VBW   3 MHz
                          137 dB V             2.47595190 GHz    SWT   5 ms        Unit         dB V
                    137
                                                                         2 [T1]            68.40 dB V
                                                                                                          A
                    130                                                              2.47595190 GHz
                                                                         1 [T1]            69.47 dB V
                                                                                     2.41302605 GHz
                    120



                    110


                          1MAX                                                                           1MA
                    100                                                                                  2AP

                          4MAX                                                                           4MA
                     90



                     80


                                    1                                           2
                     70



                     60



                     50



                     40
                     37
                          Center 2.45 GHz                   10 MHz/                    Span 100 MHz




FCC Part 18                                                                                                    Page 14 of 19


Bay Area Compliance Laboratories Corp. (Shenzhen)                                         Report No.: RSZ141208552-00

     Variation in Operating Frequency with Line Voltage

The EUT was operated / warmed by at least 10 minutes of use with a 1000 mL water load at room
temperature at the beginning of the test. Then the operating frequency was monitored as the input voltage
was varied between 80 and 125 percent of the nominal rating.

The results of this test are as follows:

Line voltage varied from 96 VAC to 150 VAC.


                             Low Frequency                              High Frequency
                                (MHz)                                       (MHz)

                                    2412.63                                    2474.95



Please refer to following pages for details of the variation in operating frequency with line voltage
measurement.
                                          Marker 2 [T1]          RBW   1 MHz       RF Att     40 dB
                          Ref Lvl                  69.16 dB V   VBW   3 MHz
                          137 dB V            2.47494990 GHz    SWT   5 ms        Unit         dB V
                    137
                                                                        2 [T1]            69.16 dB V
                                                                                                         A
                    130                                                             2.47494990 GHz
                                                                        1 [T1]            69.65 dB V
                                                                                    2.41262525 GHz
                    120



                    110


                          1MAX                                                                          1MA
                    100                                                                                 2AP



                     90



                     80


                                     1                                         2
                     70



                     60



                     50



                     40
                     37
                          Center 2.45 GHz                  10 MHz/                    Span 100 MHz




FCC Part 18                                                                                                   Page 15 of 19


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ141208552-00

RADIATED EMISSIONS
Applicable Standard
FCC §18.305 and FCC §18.309


Measurement Uncertainty
All measurements involve certain levels of uncertainties, especially in field of EMC. The factors
contributing to uncertainties are spectrum analyzer, cable loss, antenna factor calibration, antenna
directivity, antenna factor variation with height, antenna phase center variation, antenna factor frequency
interpolation, measurement distance variation, site imperfections, mismatch (average), and system
repeatability.

Based on CISPR 16-4-2:2011, the expended combined standard uncertainty of radiation emissions at Bay
Area Compliance Laboratories Corp. (Shenzhen) is shown in below table. And the uncertainty will not be
taken into consideration for the test data recorded in the report

              Frequency                        Polarity                    Measurement uncertainty

          9 kHz~30MHz                               /                 4.11 dB (k=2, 95% level of confidence)
                                              Horizontal              4.62 dB (k=2, 95% level of confidence)
         30MHz~200MHz
                                               Vertical               4.54 dB (k=2, 95% level of confidence)
                                              Horizontal              4.84 dB (k=2, 95% level of confidence)
          200MHz~1GHz
                                               Vertical               5.91 dB (k=2, 95% level of confidence)
          1 GHz~6 GHz                    Horizontal / Vertical        4.68 dB (k=2, 95% level of confidence)
           Above 6 GHz                   Horizontal / Vertical        4.92 dB (k=2, 95% level of confidence)


EUT Setup




FCC Part 18                                                                                     Page 16 of 19


Bay Area Compliance Laboratories Corp. (Shenzhen)                             Report No.: RSZ141208552-00

The radiated emission tests were performed in the 3 meters chamber test site, using the setup accordance
with the FCC MP - 5. The specification used was the FCC part 18 limits.

The socket was connected to 120 VAC/60 Hz power source.


EMI Test Receiver Setup and Spectrum Analyzer Setup
The system was investigated from 30 MHz to 24.5 GHz.

During the radiated emission test, the EMI test receiver and Spectrum Analyzer were set with the
following configurations:

     Frequency Range            RBW                 Video B/W          IF B/W             Detector

    30MHz – 1000 MHz           100 kHz               300 kHz           120kHz                QP
                                1MHz                 3 MHz                /                  PK
       Above 1 GHz
                                1MHz                  10 Hz               /                 Ave.


Test Procedure
Maximizing procedure was performed on the six (6) highest emissions to ensure that the EUT complied
with all installation combinations.

The EUT was in the normal (naïve) operating mode during the final qualification test to represent the
worst results.

All final data was recorded in the Quasi-peak detection mode from 30 MHz to 1 GHz, the average
detection mode for above 1 GHz.




FCC Part 18                                                                                  Page 17 of 19


Bay Area Compliance Laboratories Corp. (Shenzhen)                                   Report No.: RSZ141208552-00

Test Equipment List and Details

                                                                                     Calibration   Calibration
     Manufacturer           Description             Model          Serial Number
                                                                                        Date        Due Date
          HP                 Amplifier              8447E            1937A01046      2014-05-06    2015-05-06
   Rohde & Schwarz       EMI Test Receiver           ESCI                  101120    2014-11-03    2015-11-03
     Sunol Sciences     Broadband Antenna             JB3              A111513       2014-06-18    2017-06-17
      A.H. System          Horn Antenna         SAS-200/571                 135      2012-02-11    2015-02-10
                                                   ALN-
     DUCOMMUN              Pre-amplifier                              991373-01      2014-08-03    2015-08-03
                                                22093530-01
     DUCOMMUN              Horn Antenna         ARH-4223-02          1007726-03      2013-08-03    2016-08-03
   Rohde & Schwarz        Signal Analyzer           FSIQ26           837405/023      2014-08-22    2015-08-22
          Mini             Pre-amplifier         ZVA-183-S+          5969001149      2014-04-03    2015-04-03
          TDK                Chamber              Chamber A                 2#       2012-10-15    2015-10-15
          TDK                Chamber              Chamber B                 1#       2014-07-23    2015-07-22
          R&S            Auto test Software         EMC32                  V9.10        NCR           NCR

 * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
 been performed in accordance to requirements, traceable to National Primary Standards and International System of
 Units (SI).


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit – Corrected Amplitude


Test Results Summary
According to the data in the following table, the EUT complied with the FCC Part 18, the worst margin
reading as below:


                           24.16 dB at 8611.22 MHz in the Vertical polarization


Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level complies with the limit if

                                              Lm + U(Lm) ≤ Llim + Ucispr

In BACL, U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.


FCC Part 18                                                                                        Page 18 of 19


Bay Area Compliance Laboratories Corp. (Shenzhen)                             Report No.: RSZ141208552-00

Test Data and Plots
     Environmental Conditions

               Temperature:               23 ℃
        Relative Humidity:                 46 %
              ATM Pressure:              100.0 kPa

    The testing was performed by Joson Xiao on 2014-12-17.

   Test Mode: The max fan speed, max brightness and max output power
   30 MHz – 24.5 GHz

                Corrected     Antenna                Turntable   Correction
Frequency                                Antenna                                Limit    Margin
                Amplitude      height                 position    Factor                          Remark
  (MHz)                                  Polarity                             (dBμV/m)    (dB)
                (dBμV/m)        (cm)                   (deg)      (dB/m)
   49.43          19.79        181.0        V          344.0       -19.3       70.73      50.94      QP
   55.22          16.72        346.0        V          301.0       -20.1       70.73      54.01      QP
  115.50          18.80        256.0        H          108.0       -13.6       70.73      51.93      QP
  440.63          17.87        110.0        V          17.0        -10.0       70.73      52.86      QP
  729.35          18.16        277.0        H          120.0        -5.2       70.73      52.57      QP
  953.01          20.26        234.0        V          133.0        -1.9       70.73      50.47      QP
  2082.16         27.59        200.0        V          223          3.23       70.73      43.14     Ave.
  4372.75         40.65        140.0        V          154         11.63       70.73      30.08     Ave.
  8611.22         46.57        100.0        V          190          0.74       70.73      24.16     Ave.
  4426.85         38.44        130.0        H          149          0.74       70.73      32.29     Ave.
  7835.67         43.36        160.0        H          122         -0.58       70.73      27.37     Ave.
  8250.5          32.5         160.0        H           58         -0.58       70.73      38.23     Ave.
  4915.6          43.72        100.0        H           62          0.74       70.73      27.01     Ave.




                                       ***** END OF REPORT *****




FCC Part 18                                                                                  Page 19 of 19



Document Created: 2015-02-09 20:43:06
Document Modified: 2015-02-09 20:43:06

© 2024 FCC.report