Test Report

FCC ID: PQN91843TX2G4

Test Report

Download: PDF
FCCID_3574206

                                                                 TEST REPORT

                                             Report No.: 17030050HKG-001

                                             Spin Master Toys Far East Ltd.


                                                          Application
                                                              For
                                                          Certification
                                                        (Original Grant)
                                                  (FCC ID: PQN91843TX2G4)

                                                                      Transceiver




Prepared and Checked by:                                                                    Approved by:

                                                                                                                         Digitally signed by
                                                                                                                         Koo Wai Ip
                                                                                                                         Location: Intertek
                                                                                                                         Testing Services
                                                                                                                         Hong Kong Ltd.
Signed On File
Xu Lap Ho, Leo                                                                              Koo Wai Ip
Assistant Engineer                                                                          Technical Supervisor
                                                                                            Date: March 22, 2017

-   Intertek's standard Terms and Conditions can be obtained at our website http://www.intertek.com/terms/.
-   The test report only allows to be revised within the retention period unless further standard or the requirement was noticed.
-   This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and
    liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the
    agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and
    then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be
    approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the
    material, product, or service is or has ever been under an Intertek certification program.
-   © 2016 Intertek




                                                  Intertek Testing Services Hong Kong Ltd.
                                          2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                                Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


                        INTERTEK TESTING SERVICES



                         GENERAL INFORMATION


Grantee:                    Spin Master Toys Far East Ltd.
Grantee Address:            Room 1113, 11/F, Chinachem Golden Plaza,
                            77 Mody Road, Tsim Sha Tsui East,
                            Kowloon, Hong Kong.
Contact Person:             Andy Wong
Tel:                        (852) 2301-3822
Fax:                        N/A
e-mail:                     andyw@spinmaster.com
Manufacturer:               Spin Master Toys Far East Ltd.
Manufacturer Address:       Room 1113, 11/F, Chinachem Golden Plaza,
                            77 Mody Road, Tsim Sha Tsui East,
                            Kowloon, Hong Kong.
Brand Name:                 MEC
Model:                      91843TX
Phantom No.:                20087888
Type of EUT:                Transceiver
Description of EUT:         MEC RC MuscleCar Transmitter
Serial Number:              N/A
FCC ID:                     PQN91843TX2G4
Date of Sample Submitted:   March 01, 2017
Date of Test:               March 01, 2017 to March 17, 2017
Report No.:                 17030050HKG-001
Report Date:                March 22, 2017
Environmental Conditions:   Temperature: +10 to 40°C
                            Humidity: 10 to 90%




Report No.: 17030050HKG-001                                            i
FCC ID: PQN91843TX2G4


                              INTERTEK TESTING SERVICES



                               SUMMARY OF TEST RESULT


           TEST SPECIFICATION                                    REFERENCE                RESULTS
 Radiated Emission
                                                                 15.249, 15.209              Pass
 Radiated Emission on the Bandedge
 Radiated Emission in Restricted Bands                                15.205                 Pass

The equipment under test is found to be complying with the following standards:
FCC Part 15, October 1, 2015 Edition




 Note: 1. The EUT uses a permanently attached antenna which, in accordance to section 15.203, is
          considered sufficient to comply with the pervisions of this section.
       2. Pursuant to FCC part 15 Section 15.215(c), the 20 dB bandwidth of the emission was contained
          within the frequency band designated (mentioned as above) which the EUT operated. The
          effects, if any, from frequency sweeping, frequency hopping, other modulation techniques and
          frequency stability over excepted variations in temperature and supply voltage were considered.


Report No.: 17030050HKG-001                                                                            ii
FCC ID: PQN91843TX2G4


                                   INTERTEK TESTING SERVICES



                                               Table of Contents

1.0   General Description ............................................................................................ 1
  1.1  Product Description ........................................................................................... 1
  1.2  Related Submittal(s) Grants ............................................................................... 1
  1.3  Test Methodology .............................................................................................. 1
  1.4  Test Facility ....................................................................................................... 1

2.0   System Test Configuration ................................................................................. 2
  2.1   Justification ........................................................................................................ 2
  2.2   EUT Exercising Software ................................................................................... 2
  2.3   Special Accessories ........................................................................................... 2
  2.4   Measurement Uncertainty .................................................................................. 2
  2.5   Support Equipment List and Description............................................................. 2

3.0   Emission Results ................................................................................................ 3
  3.1  Field Strength Calculation .................................................................................. 3
  3.2  Radiated Emission Configuration Photograph .................................................... 4
  3.3  Radiated Emission Data .................................................................................... 4

4.0      Equipment Photographs ..................................................................................... 9

5.0      Product Labelling ................................................................................................ 9

6.0      Technical Specifications ..................................................................................... 9

7.0      Instruction Manual .............................................................................................. 9

8.0   Miscellaneous Information ............................................................................... 10
  8.1   Radiated Emission on the Bandedge ............................................................... 10
  8.2   Discussion of Pulse Desensitization ................................................................. 11
  8.3   Calculation of Average Factor .......................................................................... 11
  8.4   Emissions Test Procedures ............................................................................. 13

9.0      Equipment List .................................................................................................. 16




Report No.: 17030050HKG-001                                                                                             iii
FCC ID: PQN91843TX2G4


                          INTERTEK TESTING SERVICES

1.0   General Description

1.1   Product Description

      The Equipment Under Test (EUT) is a portable 2.4GHz Transceiver
      (Controller Unit) for a RC car operating at the frequency range of 2420.5-
      2460.5MHz with 1 MHz channel spacing.
      The EUT is powered by 3*1.5V AAA battery. After switching on the EUT and
      being paired with car, the car can be controlled to move forward/backward
      and turn left/ right by the controller.

      Antenna Type: Internal, Integral

      For electronic filing, the brief circuit description is saved with filename: descri.pdf.


1.2   Related Submittal(s) Grants

      The Certification procedure of transceiver for this transceiver (with
      FCC ID: PQN91843RX2G4) is being processed as the same time of this
      application.


1.3   Test Methodology

      Radiated emission measurements was performed according to the
      procedures in ANSI C63.10 (2013).         All radiated measurements were
      performed in an 3m Chamber. Preliminary scans were performed in the
      3m Chamber only to determine worst case modes. All radiated tests were
      performed at an antenna to EUT distance of 3 meters, unless stated
      otherwise in the “Justification Section” of this Application.


1.4   Test Facility

      The 3m Chamber facility used to collect the radiated data is located at
      Workshop No. 3, G/F., World-Wide Industrial Centre, 43-47 Shan Mei Street, Fo
      Tan, Sha Tin, N.T., Hong Kong. This test facility and site measurement data
      have been placed on file with the FCC.




Report No.: 17030050HKG-001                                                           1 of 16
FCC ID: PQN91843TX2G4


                        INTERTEK TESTING SERVICES

2.0   System Test Configuration

2.1   Justification

      The system was configured for testing in a typical fashion (as a customer would
      normally use it), and in the confines as outlined in ANSI C63.10 (2013).

      The device was powered by new 3*1.5V AAA batteries.

      For maximizing emissions, the EUT was rotated through 360°, the antenna
      height was varied from 1 meter to 4 meters above the ground plane, and the
      antenna polarization was changed. This step by step procedure for maximizing
      emissions led to the data reported in Exhibit 3.0.

      The unit was operated standalone and placed in the center of the turntable.

      The equipment under test (EUT) was configured for testing in a typical fashion
      (as a customer would normally use it). The EUT was mounted to a plastic stand
      if necessary and placed on the wooden turntable, which enabled the engineer to
      maximize emissions through its placement in the three orthogonal axes.


2.2   EUT Exercising Software

      There was no special software to exercise the device.         Once the unit is
      powered up, it transmits the RF signal continuously.


2.3   Special Accessories

      There are no special accessories necessary for compliance of this product.


2.4   Measurement Uncertainty

      When determining of the test conclusion, the Measurement Uncertainty of test
      has been considered.

      Uncertainty and Compliance - Unless the standard specifically states that
      measured values are to be extended by the measurement uncertainty in
      determining compliance, all compliance determinations are based on the actual
      measured value.


2.5   Support Equipment List and Description

      N/A.




Report No.: 17030050HKG-001                                                   2 of 16
FCC ID: PQN91843TX2G4


                          INTERTEK TESTING SERVICES

3.0   Emission Results

      Data is included of the worst case configuration (the configuration which resulted
      in the highest emission levels). A sample calculation, configuration photographs
      and data tables of the emissions are included.


3.1   Field Strength Calculation

      The field strength is calculated by adding the Antenna Factor and Cable Factor,
      and subtracting the Amplifier Gain (if any), Average Factor (optional) from the
      measured reading. The basic equation with a sample calculation is as follows:
      FS = RA + AF + CF - AG - AV
      where          FS = Field Strength in dBµV/m
                     RA = Receiver Amplitude (including preamplifier) in dBµV
                     CF = Cable Attenuation Factor in dB
                     AF = Antenna Factor in dB
                     AG = Amplifier Gain in dB
                     AV = Average Factor in dB

      In the following table(s), the reading shown on the data table reflects the preamplifier
      gain. An example for the calculations in the following table is as follows:
      FS = RR + LF
      where           FS = Field Strength in dBµV/m
                      RR = RA - AG - AV in dBµV
                      LF = CF + AF in dB

      Assume a receiver reading of 52.0 dBµV is obtained. The antenna factor of
      7.4 dB and cable factor of 1.6 dB are added. The amplifier gain of 29 dB and
      average factor of 5 dB are subtracted, giving a field strength of 27 dBµV/m.
      This value in dBµV/m was converted to its corresponding level in µV/m.

      RA = 52.0 dBµV/m
      AF = 7.4 dB                           RR = 18.0 dBµV
      CF = 1.6 dB                           LF = 9.0 dB
      AG = 29.0 dB
      AV = 5.0 dB
      FS = RR + LF
      FS = 18 + 9 = 27 dBµV/m

      Level in µV/m = Common Antilogarithm [(27 dBµV/m)/20] = 22.4 µV/m




Report No.: 17030050HKG-001                                                          3 of 16
FCC ID: PQN91843TX2G4


                        INTERTEK TESTING SERVICES

3.2   Radiated Emission Configuration Photograph

      The worst case in radiated emission was found at 4921 MHz

      For electronic filing, the worst case radiated emission configuration photographs
      are saved with filename: radiated photos.pdf.


3.3   Radiated Emission Data

      The data on the following page lists the significant emission frequencies, the
      limit and the margin of compliance. Numbers with a minus sign are below the
      limit.

      Judgment: Passed by 1.2 dB




Report No.: 17030050HKG-001                                                    4 of 16
FCC ID: PQN91843TX2G4


                              INTERTEK TESTING SERVICES

Applicant: Spin Master Toys Far East Ltd.                       Date of Test: March 17, 2017
Model: 91843TX
Worst-Case Operating Mode: Transmitting
                                       Table 1
                                Radiated Emissions
                 Pursuant to FCC Part 15 Section 15.249 Requirement
Lowest Channel
                              Pre-Amp Antenna   Net at  Average Calculated   Average Limit
Polari- Frequency   Reading     Gain   Factor 3m - Peak Factor    at 3m          at 3m        Margin
zation     (MHz)    (dBμV)      (dB)    (dB)  (dBμV/m)    (dB)  (dBμV/m)       (dBμV/m)        (dB)
  V      2400.000     55.4       33     29.4     51.8    23.5      28.3           54.0        -25.7
  V      2420.500     89.4       33     29.4     85.8    23.5      62.3           94.0        -31.7
  V     4841.000     70.1        33     34.9    72.0     23.5     48.5           54.0          -5.5
  V     7261.500     49.5        33     37.9    54.4     23.5     30.9           54.0         -23.1
  H      9682.000     51.9       33     40.4     59.3    23.5      35.8           54.0        -18.2
  H     12102.500    45.3        33     40.5    52.8     23.5     29.3           54.0         -24.7
  V     14523.000     47.9       33     38.4     53.3    23.5      29.8           54.0        -24.2

                                    Pre-Amp    Antenna      Net at      Peak Limit
 Polari-   Frequency    Reading       Gain      Factor    3m - Peak       at 3m          Margin
 zation       (MHz)     (dBμV)        (dB)       (dB)     (dBμV/m)      (dBμV/m)          (dB)
   V        2400.000     55.4          33        29.4        51.8          74.0          -22.2
   V        2420.500     89.4          33        29.4        85.8         114.0          -28.2
   V        4841.000     70.1          33        34.9       72.0          74.0            -2.0
   V        7261.500     49.5          33        37.9       54.4          74.0           -19.6
   H        9682.000     51.9          33        40.4        59.3          74.0          -14.7
   H       12102.500     45.3          33        40.5       52.8          74.0           -21.2
   V       14523.000     47.9          33        38.4        53.3          74.0          -20.7

NOTES: 1. Peak Detector Data unless otherwise stated.

           2. All measurements were made at 3 meters. Harmonic emissions not
              detected at the 3-meter distances were measured at 0.3-meter and an
              inverse proportional extrapolation was performed to compare the signal
              level to the 3-meter limit. No other harmonic emissions than those
              reported were detected at a test distance of 0.3-meter.

           3. Negative sign in the column shows value below limit.

           4. Horn antenna is used for the emission over 1000MHz.

           5. Emission (the row indicated by bold italic) within the restricted band meets
              the requirement of FCC Part 15 Section 15.205.

           6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 17030050HKG-001                                                                  5 of 16
FCC ID: PQN91843TX2G4


                              INTERTEK TESTING SERVICES

Applicant: Spin Master Toys Far East Ltd.                       Date of Test: March 17, 2017
Model: 91843TX
Worst-Case Operating Mode: Transmitting
                                       Table 2
                                Radiated Emissions
                 Pursuant to FCC Part 15 Section 15.249 Requirement
Middle Channel
                              Pre-Amp Antenna   Net at  Average Calculated   Average Limit
Polari- Frequency   Reading     Gain   Factor 3m - Peak Factor    at 3m          at 3m        Margin
zation     (MHz)    (dBμV)      (dB)    (dB)  (dBμV/m)    (dB)  (dBμV/m)       (dBμV/m)        (dB)
  V      2440.500     90.0       33     29.4     86.4    23.5      62.9           94.0        -31.1
  V     4881.000     69.4        33     34.9    71.3     23.5     47.8           54.0          -6.2
  V     7321.500     49.6        33     37.9    54.5     23.5     31.0           54.0         -23.0
  H      9762.000     51.2       33     40.4     58.6    23.5      35.1           54.0        -18.9
  H     12202.500    44.9        33     40.5    52.4     23.5     28.9           54.0         -25.1
  V     14643.000     48.1       33     38.4     53.5    23.5      30.0           54.0        -24.0

                                    Pre-Amp    Antenna      Net at      Peak Limit
 Polari-   Frequency    Reading       Gain      Factor    3m - Peak       at 3m          Margin
 zation       (MHz)     (dBμV)        (dB)       (dB)     (dBμV/m)      (dBμV/m)          (dB)
   V        2440.000     90.0          33        29.4        86.4         114.0          -27.6
   V        4881.000     69.4          33        34.9       71.3          74.0            -2.7
   V        7321.500     49.6          33        37.9       54.5          74.0           -19.5
   H        9762.000     51.2          33        40.4        58.6          74.0          -15.4
   H       12202.500     44.9          33        40.5       52.4          74.0           -21.6
   V       14643.000     48.1          33        38.4        53.5          74.0          -20.5

NOTES: 1. Peak Detector Data unless otherwise stated.

           2. All measurements were made at 3 meters. Harmonic emissions not
              detected at the 3-meter distances were measured at 0.3-meter and an
              inverse proportional extrapolation was performed to compare the signal
              level to the 3-meter limit. No other harmonic emissions than those
              reported were detected at a test distance of 0.3-meter.

           3. Negative sign in the column shows value below limit.

           4. Horn antenna is used for the emission over 1000MHz.

           5. Emission (the row indicated by bold italic) within the restricted band meets
              the requirement of FCC Part 15 Section 15.205.

           6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 17030050HKG-001                                                                  6 of 16
FCC ID: PQN91843TX2G4


                                 INTERTEK TESTING SERVICES

Applicant: Spin Master Toys Far East Ltd.                              Date of Test: March 17, 2017
Model: 91843TX
Worst-Case Operating Mode: Transmitting
                                        Table 3
                                 Radiated Emissions
                  Pursuant to FCC Part 15 Section 15.249 Requirement
Highest Channel
                                 Pre-Amp Antenna   Net at  Average Calculated      Average Limit
Polari- Frequency      Reading     Gain   Factor 3m - Peak Factor    at 3m             at 3m        Margin
zation     (MHz)       (dBμV)      (dB)    (dB)  (dBμV/m)    (dB)  (dBμV/m)          (dBμV/m)        (dB)
  V      2460.500        89.3       33     29.4     85.7    23.5      62.2              94.0        -31.8
  V     2483.500        55.6        33     29.4    52.0     23.5     28.5              54.0         -25.5
  V     4921.000        70.9        33     34.9    72.8     23.5     49.3              54.0          -4.7
  V     7381.500        51.3        33     37.9    56.2     23.5     32.7              54.0         -21.3
  H      9842.000        51.1       33     40.4     58.5    23.5      35.0              54.0        -19.0
  H     12302.500       45.1        33     40.5    52.6     23.5     29.1              54.0         -24.9
  V     14763.000        47.9       33     38.4     53.3    23.5      29.8              54.0        -24.2

                                     Pre-Amp    Antenna      Net at        Peak Limit
 Polari-   Frequency      Reading      Gain      Factor    3m - Peak         at 3m        Margin
 zation       (MHz)       (dBμV)       (dB)       (dB)     (dBμV/m)        (dBμV/m)        (dB)
   V        2460.500       89.3         33        29.4        85.7           114.0        -28.3
   V        2483.500       55.6         33        29.4       52.0            74.0         -22.0
   V        4921.000       70.9         33        34.9       72.8            74.0          -1.2
   V        7381.500       51.3         33        37.9       56.2            74.0         -17.8
   H        9842.000       51.1         33        40.4        58.5            74.0        -15.5
   H       12302.500       45.1         33        40.5       52.6            74.0         -21.4
   V       14763.000       47.9         33        38.4        53.3            74.0        -20.7

NOTES: 1. Peak Detector Data unless otherwise stated.

           2. All measurements were made at 3 meters. Harmonic emissions not
              detected at the 3-meter distances were measured at 0.3-meter and an
              inverse proportional extrapolation was performed to compare the signal
              level to the 3-meter limit. No other harmonic emissions than those
              reported were detected at a test distance of 0.3-meter.

           3. Negative sign in the column shows value below limit.

           4. Horn antenna is used for the emission over 1000MHz.

           5. Emission (the row indicated by bold italic) within the restricted band meets
              the requirement of FCC Part 15 Section 15.205.

           6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 17030050HKG-001                                                                        7 of 16
FCC ID: PQN91843TX2G4


                         INTERTEK TESTING SERVICES

Applicant: Spin Master Toys Far East Ltd.                 Date of Test: March 17, 2017
Model: 91843TX
Worst-Case Operating Mode: Transmitting
                                    Table 4
                             Radiated Emissions
              Pursuant to FCC Part 15 Section 15.209 Requirement

                               Pre- Antenna    Net     Limit
             Frequency Reading amp Factor     at 3m    at 3m                   Margin
Polarization   (MHz)   (dBμV) (dB)   (dB)   (dBμV/m) (dBμV/m)                   (dB)
     H         53.536   24.4    16   11.0      19.4     40.0                   -20.6
     V        100.907   25.1    16   12.0      21.1     43.5                   -22.4
     V        112.740   23.5    16   14.0      21.5     43.5                   -22.0
     H        207.769   19.0    16   17.0      20.0     43.5                   -23.5
     H        582.700   16.8    16   28.0      28.8     46.0                   -17.2
     H        797.170   16.7    16   31.0      31.7     46.0                   -14.3


NOTES: 1. Peak Detector Data unless otherwise stated.

         2. All measurements were made at 3 meters. Harmonic emissions not
            detected at the 3-meter distances were measured at 0.3-meter and an
            inverse proportional extrapolation was performed to compare the signal
            level to the 3-meter limit. No other harmonic emissions than those
            reported were detected at a test distance of 0.3-meter.

         3. Negative sign in the column shows value below limit.

         4. Horn antenna is used for the emission over 1000MHz.

         5. Emission (the row indicated by bold italic) within the restricted band meets
            the requirement of FCC Part 15 Section 15.205.

         6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 17030050HKG-001                                                     8 of 16
FCC ID: PQN91843TX2G4


                         INTERTEK TESTING SERVICES

4.0   Equipment Photographs

      For electronic filing, the photographs are saved with filename: external photos.pdf
      and internal photos.pdf.


5.0   Product Labelling

      For electronics filing, the FCC ID label artwork and the label location are saved
      with filename: label.pdf.


6.0   Technical Specifications

      For electronic filing, the block diagram and schematic of the tested EUT are
      saved with filename: block.pdf and circuit.pdf respectively.


7.0   Instruction Manual

      For electronic filing, a preliminary copy of the Instruction Manual is saved with
      filename: manual.pdf.

      This manual will be provided to the end-user with each unit sold/leased in the
      United States.




Report No.: 17030050HKG-001                                                      9 of 16
FCC ID: PQN91843TX2G4


                        INTERTEK TESTING SERVICES

8.0   Miscellaneous Information

      The miscellaneous information includes details of the test procedure and
      measured bandwidth / calculation of factor such as pulse desensitization and
      averaging factor (calculation and timing diagram).


8.1   Radiated Emission on the Bandedge

      The test data of bandedge emissions were shown on the above radiated
      emissions table 1 & table 3 respectively.


      Emissions radiated outside of the specified frequency bands, except harmonics,
      are attenuated by 50dB below the level of the fundamental or to the general
      radiated emissions limits in Section 15.209, whichever is the lesser attenuation,
      which meet the requirement of part 15.249(d).

      The resultant field strength meets the general radiated emission limit in
      Section 15.209, which does not exceed 74 dBµV/m (Peak Limit) and 54 dBµV/m
      (Average Limit).




Report No.: 17030050HKG-001                                                   10 of 16
FCC ID: PQN91843TX2G4


                        INTERTEK TESTING SERVICES

8.2   Discussion of Pulse Desensitization

      Pulse desensitivity is not applicable for this device. The effective period (Teff)
      is approximately 0.95ms for a digital “1” bit which illustrated on technical
      specification, with a resolution bandwidth (3dB) of 1MHz, so the pulse
      desensitivity factor is 0dB.


8.3   Calculation of Average Factor


      The duty cycle is simply the on-time divided by the period:

      The duration of one cycle = 100ms

      Effective period of the cycle = 7*0.95 = 6.65ms

      DC = 6.65/100 = 0.0665ms

      Therefore, the averaging factor is found by 20log 0.0665 = -23.5dB.




Report No.: 17030050HKG-001                                                    11 of 16
FCC ID: PQN91843TX2G4


                      INTERTEK TESTING SERVICES

     Average Factor




Report No.: 17030050HKG-001                       12 of 16
FCC ID: PQN91843TX2G4


                          INTERTEK TESTING SERVICES

8.4   Emissions Test Procedures

      The following is a description of the test procedure used by Intertek Testing
      Services Hong Kong Ltd. in the measurements of transmitter operating under
      the Part 15, Subpart C rules.

      The transmitting equipment under test (EUT) is placed on a wooden turntable
      which is four feet in diameter and approximately 0.8m in height above the
      ground plane for emission measurement at or below 1GHz and 1.5m in height
      above the ground plane for emission measurement above 1GHz. During the
      radiated emissions test, the turntable is rotated and any cables leaving the EUT
      are manipulated to find the configuration resulting in maximum emissions. The
      EUT is adjusted through all three orthogonal axis to obtain maximum emission
      levels. The antenna height and polarization are also varied during the testing to
      search for maximum signal levels. The height of the antenna is varied from
      one to four meters.

      Detector function for radiated emissions is in peak mode. Average readings, when
      required, are taken by measuring the duty cycle of the equipment under test and
      subtracting the corresponding amount in dB from the measured peak readings. A
      detailed description for the calculation of the average factor can be found in Exhibit 8.3.

      The frequency range scanned is from the lowest radio frequency signal
      generated in the device which is greater than 9 kHz to the tenth harmonic of the
      highest fundamental frequency or 40 GHz, whichever is lower.




Report No.: 17030050HKG-001                                                            13 of 16
FCC ID: PQN91843TX2G4


                         INTERTEK TESTING SERVICES

8.4   Emissions Test Procedures (cont’d)

      The EUT is warmed up for 15 minutes prior to the test.

      AC power to the unit is varied from 85% to 115% nominal and variation in the
      fundamental emission field strength is recorded. If battery powered, a new,
      fully charged battery is used.

      Conducted measurements were made as described in ANSI C63.10 (2013).

      The IF bandwidth used for measurement of radiated signal strength was 100 kHz
      or greater when frequency is below 1000 MHz. Where pulsed transmissions of
      short enough pulse duration warrant, a greater bandwidth is selected according
      to the recommendations of Hewlett Packard Application Note 150-2. A discussion
      of whether pulse desensitivity is applicable to this unit is included in this report
      (See Exhibit 8.1). Above 1000 MHz, a resolution bandwidth of 3 MHz is used.

      Transmitter measurements are normally conducted at a measurement distance
      of three meters. However, to assure low enough noise floor in the forbidden
      bands and above 1 GHz, signals are acquired at a distance of one meter or less. All
      measurements are extrapolated to three meters using inverse scaling, unless
      otherwise reported. Measurements taken at a closer distance are so marked.




Report No.: 17030050HKG-001                                                     14 of 16
FCC ID: PQN91843TX2G4


                       INTERTEK TESTING SERVICES

8.4.1 Radiated Emission Test Setup

      The figure below shows the test setup, which is utilized to make these
      measurements.


                                                       Antenna
                                          1.0~4.0m     Tower


                                     3m                     Receiver
                                                            Antenna
                        E
                        U
                        T




          0.8m

                 Ground Plane
       3m Chamber                             □

                                                      RF Test
                                                      Receiver

                 Test setup of radiated emissions up to 1GHz



                                                       Antenna
                                          1.0~4.0m     Tower


                                     3m                     Receiver
                        E
                                                            Antenna
                        U
                        T




          1.5m

                 Ground Plane
                                              □

                                                      RF Test Spectrum
                                                      Analyzer



              Test setup of radiated emissions above 1GHz




Report No.: 17030050HKG-001                                              15 of 16
FCC ID: PQN91843TX2G4


                          INTERTEK TESTING SERVICES

9.0   Equipment List

1)    Radiated Emissions Test

 Equipment               EMI Test Receiver     Spectrum Analyzer   Biconical Antenna
 Registration No.            EW-3156               EW-2253             EW-0571
 Manufacturer                  R&S                    R&S               EMCO
 Model No.                    ESR26                 FSP40               3104C
 Calibration Date         Dec. 06, 2016          Jun. 15, 2016       May 18, 2016
 Calibration Due Date     Dec. 06, 2017          Jun. 15, 2017       Nov. 18, 2017

 Equipment              Log Periodic Antenna    Double Ridged
                                                Guide Antenna
 Registration No.            EW-0447              EW-1133
 Manufacturer                 EMCO                 EMCO
 Model No.                     3146                 3115
 Calibration Date          May 18, 2016         Nov. 05, 2015
 Calibration Due Date      Nov. 18, 2017        May 05, 2017



                             END OF TEST REPORT




Report No.: 17030050HKG-001                                                  16 of 16
FCC ID: PQN91843TX2G4



Document Created: 2017-04-27 16:17:09
Document Modified: 2017-04-27 16:17:09