Test Report

FCC ID: PQN70156

Test Report

Download: PDF
FCCID_1963010

Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the
Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory
activities as listed in the HOKLAS directory of accredited laboratories. The results                                                                  g
shown in this report were determined by this laboratory in accordance with its terms of
accreditation.                                                                                                                                             Test




                                                                   TEST REPORT

                                               Report No.: 13040262KHKG—002

                                              Spin Master Toys Far East Ltd.


                                                                        Application
                                                                            For
                                                                        Certification

                                                                     (Original Grant)


                                                            (FCC ID: PQN70156)
                                                                       Transceiver



Prepared and Checked by:                                                                     Approved by:




Wong Kwok Yeung, Kenneth                                                                     Chow Chi Ming, Billy 7
Lead, Engineer                                                                     ‘         Manager
                                                                                             Date: May 09, 2013

—    The test report only allows to be revised within the retention period unless further standard or the requirement was noticed.
—    This report is for the exclusive use of Intertek‘s Client and is provided pursuant to the agreement between Intertek and its Client. Interlek‘s responsibility and
     fiability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the
     agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and
     then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be
     approved in writing by Intertek. The obseryations and test results in this report are relevant only to the sample tested. This report by Itself does not imply that the
     material, product, or service is or has ever been under an Intertek certification program.




                                                   Intertek Testing Services Hong Kong Ltd.
                                            2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                                 Tel: (852) 2173 8888        Fax: (852) 2785 5487|        Website: www.hk.intertek—etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the
Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory
activities as listed in the HOKLAS directory of accredited laboratories. The results
shown in this report were determined by this laboratory in accordance with its terms of
accreditation.




                                               GENERAL INFORMATION

                                       Spin Master Toys Far East Ltd.
                                      BRAND NAME: N/A, MODEL: 70156

                                                         FCC ID: PQN70156

 Grantee:                                           Spin Master Toys Far East Ltd.
 Grantee Address:                                   Rm 1113, 11/F., Chinachem Golden Plaza,
                                                    77 Mody Road, Tsim Sha Tsui East,
                                                    Kowloon, Hong Kong.
 Contact Person:                                    Andy Wong
 Tel:                                               86-0769-71080068 ext 1123
 Fax:                                               86-0769-82207100
 e-mail:                                            N/A
 Manufacturer:                                      Spin Master Toys Far East Ltd.
 Manufacturer Address:                              Rm 1113A, 11/F., Chinachem Golden Plaza,
                                                    77 Mody Road, Tsim Sha Tsui East,
                                                    Kowloon, Hong Kong.
 Brand Name:                                        N/A
 Model:                                             70156
 Additional Model:                                  6021650, 1029127, 1029852
 Type of EUT:                                       Transceiver
 Description of EUT:                                SPG SGC FieldAgnt WalkieTalkie
 Serial Number:                                     N/A
 FCC ID:                                            PQN70156
 Date of Sample Submitted:                          May 03, 2013
 Date of Test:                                      May 03, 2013 to May 06, 2013
 Report No.:                                        13040262HKG-002
 Report Date:                                       May 09, 2013
 Environmental Conditions:                          Temperature: +10 to 40°C
                                                    Humidity: 10 to 90%




Report No.: 13040262HKG-002
FCC ID: PQN70156
                                            Intertek Testing Services Hong Kong Ltd.
                                       2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                             Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
                                                                                                               i


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the
Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory
activities as listed in the HOKLAS directory of accredited laboratories. The results
shown in this report were determined by this laboratory in accordance with its terms of
accreditation.


                                            SUMMARY OF TEST RESULT

                                       Spin Master Toys Far East Ltd.
                                      BRAND NAME: N/A, MODEL: 70156
                                             FCC ID: PQN70156

        TEST SPECIFICATION                                                                REFERENCE            RESULTS
 Transmitter Field Strength and                                            15.235                                Pass
 Bandwidth Requirement

The equipment under test is found to be complying with the following standards:
FCC Part 15, October 1, 2011 Edition




 Note: 1. The EUT uses a permanently attached antenna which, in accordance to section 15.203, is
          considered sufficient to comply with the pervisions of this section.
       2. Pursuant to FCC part 15 Section 15.215(c), the 20 dB bandwidth of the emission was
          contained within the frequency band designated (mentioned as above) which the EUT
          operated. The effects, if any, from frequency sweeping, frequency hopping, other
          modulation techniques and frequency stability over excepted variations in temperature
          and supply voltage were considered.



Report No.: 13040262HKG-002
FCC ID: PQN70156
                                            Intertek Testing Services Hong Kong Ltd.
                                       2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                             Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
                                                                                                                   ii


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the
Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory
activities as listed in the HOKLAS directory of accredited laboratories. The results
shown in this report were determined by this laboratory in accordance with its terms of
accreditation.




                                                       Table of Contents

1.0        General Description ............................................................................................ 1
  1.1      Product Description ............................................................................................... 1
  1.2      Related Submittal(s) Grants................................................................................... 1
  1.3      Test Methodology.................................................................................................. 1
  1.4      Test Facility........................................................................................................... 2

2.0        System Test Configuration ................................................................................. 3
  2.1      Justification ........................................................................................................... 3
  2.2      EUT Exercising Software....................................................................................... 3
  2.3      Special Accessories .............................................................................................. 3
  2.4      Equipment Modification ......................................................................................... 3
  2.5      Measurement Uncertainty...................................................................................... 4
  2.6      Support Equipment List and Description ................................................................ 3

3.0        Emission Results ................................................................................................ 5
  3.1      Field Strength Calculation...................................................................................... 5
  3.2      Radiated Emission Configuration Photograph........................................................ 5
  3.3      Radiated Emission Data ........................................................................................ 5

4.0        Equipment Photographs..................................................................................... 7

5.0        Product Labelling ................................................................................................ 7

6.0        Technical Specifications..................................................................................... 7

7.0        Instruction Manual .............................................................................................. 7

8.0        Miscellaneous Information ................................................................................. 7
  8.1      Measured Bandwidth.......................................................................................... 11
  8.2      Discussion of Pulse Desensitization..................................................................... 11
  8.3      Calculation of Average Factor................................................................................ 8
  8.4      Emissions Test Procedures................................................................................... 9

9.0        Equipment List .................................................................................................. 13




Report No.: 13040262HKG-002
FCC ID: PQN70156
                                            Intertek Testing Services Hong Kong Ltd.
                                       2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                             Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
                                                                                                                           iii


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the
Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory
activities as listed in the HOKLAS directory of accredited laboratories. The results
shown in this report were determined by this laboratory in accordance with its terms of
accreditation.


1.0        General Description

1.1        Product Description

           The Equipment Under Test (EUT) is a Transceiver for push-to-talk walkie talkie
           operating 49.860MHz which is controlled by a crystal. The EUT is power by 1 x
           9.0VDC alkaline battery. The EUT has an ON/OFF switch, transmit button (PTT)
           and pulse generation button (code key). The communication method of the EUT
           is half duplex.

           To transmit the signal, press and hold the transmit button. To send the pulse
           signal, press and hold the pulse generation button. The receiving mode will
           active after switching on the EUT.

           The Model: 6021650, 1029127 and 1029852 are the same as the Model:
           70156 in hardware aspect. The difference in item number serves as
           marketing strategy.

           Antenna Type: External, Integral

           For electronic filing, the brief circuit description is saved with filename: descri.pdf.

1.2        Related Submittal(s) Grants

           This is a single application for certification of a transmitter. The receiver for this
           transmitter is authorized by Versification procedure.

1.3        Test Methodology

           Radiated emission measurements was performed according to the procedures
           in ANSI C63.4 (2009). All radiated measurements were performed in an Open
           Area Test Site. Preliminary scans were performed in the Open Area Test Site
           only to determine worst case modes. All radiated tests were performed at an
           antenna to EUT distance of 3 meters, unless stated otherwise in the
           “Justification Section” of this Application.




Report No.: 13040262HKG-002
FCC ID: PQN70156
                                            Intertek Testing Services Hong Kong Ltd.
                                       2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                             Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
                                                                                                               1


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the
Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory
activities as listed in the HOKLAS directory of accredited laboratories. The results
shown in this report were determined by this laboratory in accordance with its terms of
accreditation.




1.4        Test Facility

           The open area test site and conducted measurement facility used to collect the
           radiated data is located at Garment Centre, 576 Castle Peak Road, Kowloon,
           Hong Kong. This test facility and site measurement data have been placed on
           file with the FCC.




Report No.: 13040262HKG-002
FCC ID: PQN70156
                                            Intertek Testing Services Hong Kong Ltd.
                                       2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                             Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
                                                                                                               2


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the
Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory
activities as listed in the HOKLAS directory of accredited laboratories. The results
shown in this report were determined by this laboratory in accordance with its terms of
accreditation.


2.0        System Test Configuration

2.1        Justification

           The system was configured for testing in a typical fashion (as a customer would
           normally use it), and in the confines as outlined in ANSI C63.4 (2009).

           The EUT was powered by 1 x 9.0V alkaline battery during test.

           For maximizing emissions, the EUT was rotated through 360°, the antenna
           height was varied from 1 meter to 4 meters above the ground plane, and the
           antenna polarization was changed. This step by step procedure for maximizing
           emissions led to the data reported in Exhibit 3.0.

           The unit was operated standalone and placed in the center of the turntable.

           The equipment under test (EUT) was configured for testing in a typical fashion
           (as a customer would normally use it). The EUT was mounted to a plastic stand if
           necessary and placed on the wooden turntable, which enabled the engineer to
           maximize emissions through its placement in the three orthogonal axes.


2.2        EUT Exercising Software

           There was no special software to exercise the device. Once the unit is powered
           up, it transmits the RF signal continuously.


2.3        Special Accessories

           There are no special accessories necessary for compliance of this product.


2.4        Equipment Modification

           Any modifications installed previous to testing by Spin Master Toys Far East Ltd.
           will be incorporated in each production model sold/leased in the United States.

           No modifications were installed by Intertek Testing Services Hong Kong Ltd.



Report No.: 13040262HKG-002
FCC ID: PQN70156
                                            Intertek Testing Services Hong Kong Ltd.
                                       2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                             Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
                                                                                                               3


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the
Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory
activities as listed in the HOKLAS directory of accredited laboratories. The results
shown in this report were determined by this laboratory in accordance with its terms of
accreditation.


2.5        Measurement Uncertainty

           When determining of the test conclusion, the Measurement Uncertainty of test
           has been considered.

2.6        Support Equipment List and Description

           N/A.




Report No.: 13040262HKG-002
FCC ID: PQN70156
                                            Intertek Testing Services Hong Kong Ltd.
                                       2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                             Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
                                                                                                               4


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the
Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory
activities as listed in the HOKLAS directory of accredited laboratories. The results
shown in this report were determined by this laboratory in accordance with its terms of
accreditation.


3.0        Emission Results

           Data is included of the worst case configuration (the configuration which resulted
           in the highest emission levels). A sample calculation, configuration photographs
           and data tables of the emissions are included.


3.1        Field Strength Calculation

           The field strength is calculated by adding the Antenna Factor and Cable Factor,
           and subtracting the Amplifier Gain (if any), Average Factor (optional) from the
           measured reading. The basic equation with a sample calculation is as follows:
           FS = RA + AF + CF - AG - AV
           where          FS = Field Strength in dBµV/m
                          RA = Receiver Amplitude (including preamplifier) in dBµV
                          CF = Cable Attenuation Factor in dB
                          AF = Antenna Factor in dB
                          AG = Amplifier Gain in dB
                          AV = Average Factor in dB

           In the following table(s), the reading shown on the data table reflects the preamplifier
           gain. An example for the calculations in the following table is as follows:
           FS = RR + LF
           where           FS = Field Strength in dBµV/m
                           RR = RA - AG - AV in dBµV
                           LF = CF + AF in dB

           Assume a receiver reading of 52.0 dBµV is obtained. The antenna factor of
           7.4 dB and cable factor of 1.6 dB are added. The amplifier gain of 29 dB and
           average factor of 5 dB are subtracted, giving a field strength of 27 dBµV/m.
           This value in dBµV/m was converted to its corresponding level in µV/m.

           RA = 52.0 dBµV/m
           AF = 7.4 dB                                               RR = 18.0 dBµV
           CF = 1.6 dB                                               LF = 9.0 dB
           AG = 29.0 dB
           AV = 5.0 dB
           FS = RR + LF
           FS = 18 + 9 = 27 dBµV/m

           Level in µV/m = Common Antilogarithm [(27 dBµV/m)/20] = 22.4 µV/m

Report No.: 13040262HKG-002
FCC ID: PQN70156
                                            Intertek Testing Services Hong Kong Ltd.
                                       2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                             Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
                                                                                                               5


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the
Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory
activities as listed in the HOKLAS directory of accredited laboratories. The results
shown in this report were determined by this laboratory in accordance with its terms of
accreditation.


3.2        Radiated Emission Configuration Photograph

           Worst Case Radiated Emission at 99.720 MHz

           For electronic filing, the worst case radiated emission configuration photographs
           are saved with filename: radiated photos.pdf.


3.3        Radiated Emission Data

           The data on the following page lists the significant emission frequencies, the
           limit and the margin of compliance. Numbers with a minus sign are below the
           limit.

           Judgment: Passed by 5 dB




Report No.: 13040262HKG-002
FCC ID: PQN70156
                                            Intertek Testing Services Hong Kong Ltd.
                                       2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                             Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
                                                                                                               6


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the
Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory
activities as listed in the HOKLAS directory of accredited laboratories. The results
shown in this report were determined by this laboratory in accordance with its terms of
accreditation.


Applicant: Spin Master Toys Far East Ltd. Date of Test: May 03, 2013 to May 06, 2013
Model: 70156
Mode: Transmission
                                          Table 1

                                                            Radiated Emissions

                           Pre- Antenna Average    Net     Limit
 Polari- Frequency Reading Amp Factor    Factor   at 3m    at 3m  Margin
 zation    (MHz)   (dBμV) (dB)   (dB)    (dB)   (dBμV/m) (dBμV/m) (dB)
   V       49.860   70.0    16   11.0     0.0      65.0    80.0   -15.0
   H       99.720   42.5    16   12.0      -       38.5     43.5   -5.0
   H      149.580   40.0    16   14.0      -       38.0     43.5   -5.5
   H      199.440   37.4    16   16.0      -       37.4     43.5   -6.1
   H      249.200   26.4    16   20.0      -       30.4     46.0  -15.6
   H      299.160   25.0    16   22.0      -       31.0     46.0  -15.0
   H      349.020   22.5    16   24.0      -       30.5     46.0  -15.5
   H      398.880   20.6    16   25.0      -       29.6     46.0  -16.4
   H      448.740   21.1    16   26.0      -       31.1     46.0  -14.9
   H      498.600   22.0    16   26.0      -       32.0     46.0  -14.0

NOTES: 1. Peak Detector Data unless otherwise stated.

                2. All measurements were made at 3 meters. Harmonic emissions not
                   detected at the 3-meter distances were measured at 0.3-meter and an
                   inverse proportional extrapolation was performed to compare the signal
                   level to the 3-meter limit. No other harmonic emissions than those
                   reported were detected at a test distance of 0.3-meter.

                3. Negative sign in the column shows value below limit.

                4. Horn antenna is used for the emissions over 1000MHz.




Report No.: 13040262HKG-002
FCC ID: PQN70156
                                            Intertek Testing Services Hong Kong Ltd.
                                       2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                             Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
                                                                                                               7


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the
Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory
activities as listed in the HOKLAS directory of accredited laboratories. The results
shown in this report were determined by this laboratory in accordance with its terms of
accreditation.


4.0        Equipment Photographs

           For electronic filing, the photographs are saved with filename: external photos.pdf
           and internal photos.pdf.


5.0        Product Labelling

           For electronics filing, the FCC ID label artwork and the label location are saved
           with filename: label.pdf.


6.0        Technical Specifications

           For electronic filing, the block diagram and schematic of the tested EUT are
           saved with filename: block.pdf and circuit.pdf respectively.


7.0        Instruction Manual

           For electronic filing, a preliminary copy of the Instruction Manual is saved with
           filename: manual.pdf.

           This manual will be provided to the end-user with each unit sold/leased in the
           United States.


8.0        Miscellaneous Information

           This miscellaneous information includes details of the measured bandwidth.




Report No.: 13040262HKG-002
FCC ID: PQN70156
                                            Intertek Testing Services Hong Kong Ltd.
                                       2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                             Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
                                                                                                               8


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the
Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory
activities as listed in the HOKLAS directory of accredited laboratories. The results
shown in this report were determined by this laboratory in accordance with its terms of
accreditation.


8.1        Measured Bandwidth

           The plot which shows the fundamental emission is confined in the specified
           band. The field strength of any emission appearing between the band edges
           and up to 10kHz above and below the band edges (49.81 and 49.91 MHz) is at
           least 26 dB below the carrier level. And at 49.81 & 49.91 MHz, there are at
           least 38.1 dB below the carrier level. It meets the requirement of Section
           15.235(b).




Report No.: 13040262HKG-002
FCC ID: PQN70156
                                            Intertek Testing Services Hong Kong Ltd.
                                       2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                             Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
                                                                                                               9


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the
Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory
activities as listed in the HOKLAS directory of accredited laboratories. The results
shown in this report were determined by this laboratory in accordance with its terms of
accreditation.




Report No.: 13040262HKG-002
FCC ID: PQN70156
                                            Intertek Testing Services Hong Kong Ltd.
                                       2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                             Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
                                                                                                               10


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the
Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory
activities as listed in the HOKLAS directory of accredited laboratories. The results
shown in this report were determined by this laboratory in accordance with its terms of
accreditation.




8.2        Discussion of Pulse Desensitization

           Pulse desensitivity is not applicable for this device. Since the transmitter
           transmits the RF signal continuously.


8.3        Calculation of Average Factor

           The average factor is not applicable for this device as the transmitted signal is a
           continuously signal.
8.4        Emissions Test Procedures

           The following is a description of the test procedure used by Intertek Testing
           Services in the measurements of transmitters operating under Part 15, Subpart
           C rules.

           The test set-up and procedures described below are designed to meet the
           requirements of ANSI C63.4 - 2009.

           The transmitting equipment under test (EUT) is placed on a wooden turntable
           which is four feet in diameter and approximately one meter in height above the
           ground plane. During the radiated emissions test, the turntable is rotated and
           any cables leaving the EUT are manipulated to find the configuration resulting in
           maximum emissions. The EUT is adjusted through all three orthogonal axes to
           obtain maximum emission levels. The antenna height and polarization are
           varied during the testing to search for maximum signal levels.

           Detector function for radiated emissions is in peak mode. Average readings,
           when required, are taken by measuring the duty cycle of the equipment under
           test and subtracting the corresponding amount in dB from the measured peak
           readings. A detailed description for the calculation of the average factor can
           be found in Exhibit 8.3.

           The frequency range scanned is from the lowest radio frequency signal
           generated in the device which is greater than 9 kHz to the tenth harmonic of the
           highest fundamental frequency or 40 GHz, whichever is lower.




Report No.: 13040262HKG-002
FCC ID: PQN70156
                                            Intertek Testing Services Hong Kong Ltd.
                                       2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                             Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
                                                                                                               11


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the
Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory
activities as listed in the HOKLAS directory of accredited laboratories. The results
shown in this report were determined by this laboratory in accordance with its terms of
accreditation.


8.4        Emissions Test Procedures (cont'd)


           The EUT is warmed up for 15 minutes prior to the test.

           AC power to the unit is varied from 85% to 115% nominal and variation in the
           fundamental emission field strength is recorded. If battery powered, a new,
           fully charged battery is used.

           Conducted measurements are made as described in ANSI C63.4 - 2009.

           The IF bandwidth used for measurement of radiated signal strength was 10 kHz
           for emission below 30 MHz and 120 kHz for emission from 30 MHz to 1000
           MHz. Where pulsed transmissions of short enough pulse duration warrant, a
           greater bandwidth is selected according to the recommendations of Hewlett
           Packard Application Note 150-2. A discussion of whether pulse desensitivity is
           applicable to this unit is included in this report (See Exhibit 8.2). Above 1000
           MHz, a resolution bandwidth of 1 MHz is used.

           Transmitter measurements are normally conducted at a measurement distance
           of three meters. However, to assure low enough noise floor in the restricted
           bands and above 1 GHz, signals are acquired at a distance of one meter or
           less. All measurements are extrapolated to three meters using inverse scaling,
           but those measurements taken at a closer distance are so marked.




Report No.: 13040262HKG-002
FCC ID: PQN70156
                                            Intertek Testing Services Hong Kong Ltd.
                                       2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                             Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
                                                                                                               12


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the
Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory
activities as listed in the HOKLAS directory of accredited laboratories. The results
shown in this report were determined by this laboratory in accordance with its terms of
accreditation.


9.0 Equipment List

1) Radiated Emissions Test

Equipment                               EMI Test Receiver                    Spectrum Analyzer          Log Periodic Antenna
                                         (9kHz to 7GHz)
Registration No.                            EW-2666                              EW-2188                      EW-0447
Manufacturer                            ROHDESCHWARZ                          AGILENTTECH                      EMCO
Model No.                                    ESCI7                               E4407B                         3146
Calibration Date                          May 21, 2012                       November 05, 2012            February 08, 2012
Calibration Due Date                      May 21, 2013                       November 05, 2013             August 08, 2013

Equipment                                Biconical Antenna
Registration No.                             EW-2512
Manufacturer                                  EMCO
Model No.                                     3104C
Calibration Date                        November 15, 2011
Calibration Due Date                       May 15, 2013


2)    Bandwidth Measurement

Equipment                            Communication Service                     Spectrum Analyzer
                                        Monitor (Radio)
Registration No.                          EW-1775                                  EW-2329
Manufacturer                          ROHDESCHWARZ                             ROHDESCHWARZ
Model No.                                  CMS54                                    FSP3
Calibration Date                         Nov 23, 2012                            Jan 30, 2013
Calibration Due Date                     Nov 22, 2013                            Jan 30, 2014




Report No.: 13040262HKG-002
FCC ID: PQN70156
                                            Intertek Testing Services Hong Kong Ltd.
                                       2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                             Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
                                                                                                                        13