Test Report

FCC ID: PQN44615RX2G4

Test Report

Download: PDF
FCCID_3381915

                                                                 TEST REPORT

                                             Report No.: 17020969HKG-003

                                             Spin Master Toys Far East Ltd.


                                                          Application
                                                              For
                                                          Certification
                                                        (Original Grant)
                                                  (FCC ID: PQN44615RX2G4)

                                                                      Transceiver




Prepared and Checked by:                                                                    Approved by:

                                                                                                                        Digitally signed by
                                                                                                                        Koo Wai Ip
                                                                                                                        Location: Intertek
                                                                                                                        Testing Services
                                                                                                                        Hong Kong Ltd.
Signed On File
Xu Lap Ho, Leo                                                                              Koo Wai Ip
Assistant Engineer                                                                          Technical Supervisor
                                                                                            Date: March 30, 2017

-   Intertek's standard Terms and Conditions can be obtained at our website http://www.intertek.com/terms/.
-   The test report only allows to be revised within the retention period unless further standard or the requirement was noticed.
-   This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and
    liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the
    agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and
    then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be
    approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the
    material, product, or service is or has ever been under an Intertek certification program.
-   © 2016 Intertek




                                                  Intertek Testing Services Hong Kong Ltd.
                                          2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                                Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


                        INTERTEK TESTING SERVICES



                         GENERAL INFORMATION


Grantee:                    Spin Master Toys Far East Ltd.
Grantee Address:            Room 1113, 11/F, Chinachem Golden Plaza,
                            77 Mody Road, Tsim Sha Tsui East,
                            Kowloon, Hong Kong.
Contact Person:             Andy Wong
Tel:                        (852) 2301 3822
Fax:                        (852) 2301 1822
e-mail:                     andyw@spinmaster.com
Manufacturer:               Spin Master Toys Far East Ltd.
Manufacturer Address:       Room 1113, 11/F, Chinachem Golden Plaza,
                            77 Mody Road, Tsim Sha Tsui East,
                            Kowloon, Hong Kong.
Brand Name:                 AIR HOGS
Model:                      44615RX
Phantom No.:                GBL: 20088191; EML: 20088199
Type of EUT:                Transceiver
Description of EUT:         Micro Race Drone
Serial Number:              N/A
FCC ID:                     PQN44615RX2G4
Date of Sample Submitted:   February 27, 2017
Date of Test:               February 27, 2017 to March 23, 2017
Report No.:                 17020969HKG-003
Report Date:                March 30, 2017
Environmental Conditions:   Temperature: +10 to 40°C
                            Humidity: 10 to 90%




Report No.: 17020969HKG-003                                            i
FCC ID: PQN44615RX2G4


                              INTERTEK TESTING SERVICES



                               SUMMARY OF TEST RESULT


           TEST SPECIFICATION                                    REFERENCE                RESULTS
 Radiated Emission
                                                                 15.249, 15.209              Pass
 Radiated Emission on the Bandedge
 Radiated Emission in Restricted Bands                                15.205                 Pass

The equipment under test is found to be complying with the following standards:
FCC Part 15, October 1, 2015 Edition




 Note: 1. The EUT uses a permanently attached antenna which, in accordance to section 15.203, is
          considered sufficient to comply with the pervisions of this section.
       2. Pursuant to FCC part 15 Section 15.215(c), the 20 dB bandwidth of the emission was contained
          within the frequency band designated (mentioned as above) which the EUT operated. The
          effects, if any, from frequency sweeping, frequency hopping, other modulation techniques and
          frequency stability over excepted variations in temperature and supply voltage were considered.



Report No.: 17020969HKG-003                                                                            ii
FCC ID: PQN44615RX2G4


                                    INTERTEK TESTING SERVICES



                                               Table of Contents

1.0   General Description .............................................................................................. 1
  1.1  Product Description ............................................................................................. 1
  1.2  Related Submittal(s) Grants................................................................................. 1
  1.3  Test Methodology ................................................................................................ 1
  1.4  Test Facility ......................................................................................................... 1

2.0   System Test Configuration................................................................................... 2
  2.1   Justification .......................................................................................................... 2
  2.2   EUT Exercising Software ..................................................................................... 2
  2.3   Special Accessories ............................................................................................ 2
  2.4   Measurement Uncertainty.................................................................................... 2
  2.5   Support Equipment List and Description .............................................................. 2

3.0   Emission Results .................................................................................................. 3
  3.1  Field Strength Calculation .................................................................................... 3
  3.2  Radiated Emission Configuration Photograph ..................................................... 4
  3.3  Radiated Emission Data ...................................................................................... 4

4.0       Equipment Photographs....................................................................................... 9

5.0       Product Labelling .................................................................................................. 9

6.0       Technical Specifications ...................................................................................... 9

7.0       Instruction Manual ................................................................................................ 9

8.0   Miscellaneous Information ................................................................................. 10
  8.1   Radiated Emission on the Bandedge................................................................. 10
  8.2   Discussion of Pulse Desensitization .................................................................. 11
  8.3   Calculation of Average Factor............................................................................ 11
  8.4   Emissions Test Procedures ............................................................................... 13

9.0       Equipment List .................................................................................................... 16




Report No.: 17020969HKG-003                                                                                               iii
FCC ID: PQN44615RX2G4


                          INTERTEK TESTING SERVICES

1.0   General Description

1.1   Product Description

      The Equipment Under Test (EUT) is a portable 2.4GHz Transceiver (Drone Unit)
      for a RC drone operating at the frequency range of 2408-2472MHz with 1 MHz
      channel spacing.
      The EUT is powered by 3.7V rechargeable battery. After switching on the EUT
      and being paired with drone, the drone can be controlled to fly
      forward/backward, upward/downward and left/ right by the controller.

      Antenna Type: Internal, Integral

      For electronic filing, the brief circuit description is saved with filename: descri.pdf.


1.2   Related Submittal(s) Grants

      The Certification procedure of transceiver for this transceiver (with FCC ID:
      PQN44615TX2G4) is being processed as the same time of this application.


1.3   Test Methodology

      Radiated emission measurements was performed according to the
      procedures in ANSI C63.10 (2013).         All radiated measurements were
      performed in an 3m Chamber. Preliminary scans were performed in the
      3m Chamber only to determine worst case modes. All radiated tests were
      performed at an antenna to EUT distance of 3 meters, unless stated
      otherwise in the “Justification Section” of this Application.


1.4   Test Facility

      The 3m Chamber facility used to collect the radiated data is located at
      Workshop No. 3, G/F., World-Wide Industrial Centre, 43-47 Shan Mei Street, Fo
      Tan, Sha Tin, N.T., Hong Kong. This test facility and site measurement data
      have been placed on file with the FCC.




Report No.: 17020969HKG-003                                                           1 of 16
FCC ID: PQN44615RX2G4


                        INTERTEK TESTING SERVICES

2.0   System Test Configuration

2.1   Justification

      The system was configured for testing in a typical fashion (as a customer would
      normally use it), and in the confines as outlined in ANSI C63.10 (2013).

      The device was powered by new 3.7v rechargeable battery.

      For maximizing emissions, the EUT was rotated through 360°, the antenna
      height was varied from 1 meter to 4 meters above the ground plane, and the
      antenna polarization was changed. This step by step procedure for maximizing
      emissions led to the data reported in Exhibit 3.0.

      The unit was operated standalone and placed in the center of the turntable.

      The equipment under test (EUT) was configured for testing in a typical fashion
      (as a customer would normally use it). The EUT was mounted to a plastic stand
      if necessary and placed on the wooden turntable, which enabled the engineer to
      maximize emissions through its placement in the three orthogonal axes.


2.2   EUT Exercising Software

      There was no special software to exercise the device.         Once the unit is
      powered up, it transmits the RF signal continuously.


2.3   Special Accessories

      There are no special accessories necessary for compliance of this product.


2.4   Measurement Uncertainty

      When determining of the test conclusion, the Measurement Uncertainty of test
      has been considered.


2.5   Support Equipment List and Description

      N/A.




Report No.: 17020969HKG-003                                                   2 of 16
FCC ID: PQN44615RX2G4


                          INTERTEK TESTING SERVICES

3.0   Emission Results

      Data is included of the worst case configuration (the configuration which resulted
      in the highest emission levels). A sample calculation, configuration photographs
      and data tables of the emissions are included.


3.1   Field Strength Calculation

      The field strength is calculated by adding the Antenna Factor and Cable Factor,
      and subtracting the Amplifier Gain (if any), Average Factor (optional) from the
      measured reading. The basic equation with a sample calculation is as follows:
      FS = RA + AF + CF - AG - AV
      where          FS = Field Strength in dBµV/m
                     RA = Receiver Amplitude (including preamplifier) in dBµV
                     CF = Cable Attenuation Factor in dB
                     AF = Antenna Factor in dB
                     AG = Amplifier Gain in dB
                     AV = Average Factor in dB

      In the following table(s), the reading shown on the data table reflects the preamplifier
      gain. An example for the calculations in the following table is as follows:
      FS = RR + LF
      where           FS = Field Strength in dBµV/m
                      RR = RA - AG - AV in dBµV
                      LF = CF + AF in dB

      Assume a receiver reading of 52.0 dBµV is obtained. The antenna factor of
      7.4 dB and cable factor of 1.6 dB are added. The amplifier gain of 29 dB and
      average factor of 5 dB are subtracted, giving a field strength of 32 dBµV/m.
      This value in dBµV/m was converted to its corresponding level in µV/m.

      RA = 52.0 dBµV/m
      AF = 7.4 dB                           RR = 18.0 dBµV
      CF = 1.6 dB                           LF = 9.0 dB
      AG = 29.0 dB
      AV = 5.0 dB
      FS = RR + LF
      FS = 18 + 9 = 27 dBµV/m

      Level in µV/m = Common Antilogarithm [(27 dBµV/m)/20] = 22.4 µV/m




Report No.: 17020969HKG-003                                                          3 of 16
FCC ID: PQN44615RX2G4


                        INTERTEK TESTING SERVICES

3.2   Radiated Emission Configuration Photograph

      The worst case in radiated emission was found at 4816.000 MHz

      For electronic filing, the worst case radiated emission configuration photographs
      are saved with filename: radiated photos.pdf.


3.3   Radiated Emission Data

      The data on the following page lists the significant emission frequencies, the
      limit and the margin of compliance. Numbers with a minus sign are below the
      limit.

      Judgment: Passed by 12.9 dB




Report No.: 17020969HKG-003                                                    4 of 16
FCC ID: PQN44615RX2G4


                              INTERTEK TESTING SERVICES

Applicant: Spin Master Toys Far East Ltd.                       Date of Test: March 23, 2017
Model: 44615RX
Worst-Case Operating Mode: Transmitting
                                       Table 1
                                Radiated Emissions
                 Pursuant to FCC Part 15 Section 15.249 Requirement
Lowest Channel
                              Pre-Amp Antenna   Net at  Average Calculated   Average Limit
Polari- Frequency   Reading     Gain   Factor 3m - Peak Factor    at 3m          at 3m        Margin
zation     (MHz)    (dBμV)      (dB)    (dB)  (dBμV/m)    (dB)  (dBμV/m)       (dBμV/m)        (dB)
  V      2400.000     49.1       33     29.4     45.5      29      16.5           54.0        -37.5
  V      2408.000     86.3       33     29.4     82.7      29      53.7           94.0        -40.3
  V      4816.000    59.2        33     34.9    61.1       29     32.1           54.0         -21.9
  V      7224.000     47.7       33     37.9     52.6      29      23.6           54.0        -30.4
  V      9632.000     38.1       33     40.4     45.5      29      16.5           54.0        -37.5
  V     12040.000    37.9        33     40.5    45.4       29     16.4           54.0         -37.6
  V     14448.000     37.3       33     40.0     44.3      29      15.3           54.0        -38.7

                                    Pre-Amp    Antenna      Net at      Peak Limit
 Polari-   Frequency    Reading       Gain      Factor    3m - Peak       at 3m          Margin
 zation       (MHz)     (dBμV)        (dB)       (dB)     (dBμV/m)      (dBμV/m)          (dB)
   V        2400.000     49.1          33        29.4        45.5          74.0          -28.5
   V        2408.000     86.3          33        29.4        82.7         114.0          -31.3
   V        4816.000     59.2          33        34.9       61.1          74.0           -12.9
   V        7224.000     47.7          33        37.9        52.6          74.0          -21.4
   V        9632.000     38.1          33        40.4        45.5          74.0          -28.5
   V       12040.000     37.9          33        40.5       45.4          74.0           -28.6
   V       14448.000     37.3          33        40.0        44.3          74.0          -29.7



NOTES: 1. Peak Detector Data unless otherwise stated.

           2. All measurements were made at 3 meters. Harmonic emissions not
              detected at the 3-meter distances were measured at 0.3-meter and an
              inverse proportional extrapolation was performed to compare the signal
              level to the 3-meter limit. No other harmonic emissions than those
              reported were detected at a test distance of 0.3-meter.

           3. Negative sign in the column shows value below limit.

           4. Horn antenna is used for the emission over 1000MHz.

           5. Emission (the row indicated by bold italic) within the restricted band meets
              the requirement of FCC Part 15 Section 15.205.

           6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 17020969HKG-003                                                                  5 of 16
FCC ID: PQN44615RX2G4


                              INTERTEK TESTING SERVICES

Applicant: Spin Master Toys Far East Ltd.                        Date of Test: March 23, 2017
Model: 44615RX
Worst-Case Operating Mode: Transmitting
                                       Table 2
                                Radiated Emissions
                 Pursuant to FCC Part 15 Section 15.249 Requirement
Middle Channel
                              Pre-Amp Antenna    Net at   Average Calculated   Average Limit
Polari- Frequency   Reading     Gain   Factor 3m - Peak    Factor   at 3m          at 3m        Margin
zation     (MHz)    (dBμV)      (dB)    (dB)   (dBμV/m)     (dB)  (dBμV/m)       (dBμV/m)        (dB)
  V      2440.000     85.6       33     29.4      82.0       29      53.0           94.0        -41.0
  V      4880.000    58.8        33     34.9     60.7        29     31.7           54.0         -22.3
  V      7320.000    47.7        33     37.9     52.6        29     23.6           54.0         -30.4
  V      9760.000     38.1       33     40.4      45.5       29      16.5           54.0        -37.5
  V     12200.000    37.9        33     40.5     45.4        29     16.4           54.0         -37.6
  V     14640.000     38.9       33     38.4      44.3       29      15.3           54.0        -38.7

                                    Pre-Amp    Antenna        Net at      Peak Limit
 Polari-   Frequency    Reading       Gain      Factor     3m - Peak        at 3m          Margin
 zation       (MHz)     (dBμV)        (dB)       (dB)       (dBμV/m)      (dBμV/m)          (dB)
   V        2440.000     85.6          33        29.4          82.0         114.0          -32.0
   V        4880.000     58.8          33        34.9         60.7          74.0           -13.3
   V        7320.000     47.7          33        37.9         52.6          74.0           -21.4
   V        9760.000     38.1          33        40.4          45.5          74.0          -28.5
   V       12200.000     37.9          33        40.5         45.4          74.0           -28.6
   V       14640.000     38.9          33        38.4          44.3          74.0          -29.7

NOTES: 1. Peak Detector Data unless otherwise stated.

           2. All measurements were made at 3 meters. Harmonic emissions not
              detected at the 3-meter distances were measured at 0.3-meter and an
              inverse proportional extrapolation was performed to compare the signal
              level to the 3-meter limit. No other harmonic emissions than those
              reported were detected at a test distance of 0.3-meter.

           3. Negative sign in the column shows value below limit.

           4. Horn antenna is used for the emission over 1000MHz.

           5. Emission (the row indicated by bold italic) within the restricted band meets
              the requirement of FCC Part 15 Section 15.205.

           6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 17020969HKG-003                                                                    6 of 16
FCC ID: PQN44615RX2G4


                                INTERTEK TESTING SERVICES

Applicant: Spin Master Toys Far East Ltd.                              Date of Test: March 23, 2017
Model: 44615RX
Worst-Case Operating Mode: Transmitting
                                         Table 3
                                  Radiated Emissions
                   Pursuant to FCC Part 15 Section 15.249 Requirement
Highest Channel
                               Pre-Amp Antenna    Net at Average Calculated   Average Limit
Polari-    Frequency Reading     Gain   Factor 3m - Peak Factor    at 3m          at 3m     Margin
zation        (MHz)  (dBμV)      (dB)    (dB)   (dBμV/m)   (dB)  (dBμV/m)       (dBμV/m)     (dB)
  V         2472.000   84.7       33     29.4      81.1     29      52.1           94.0     -41.9
  V         2483.500  49.5        33     29.4     45.9      29     16.9           54.0      -37.1
  V         4944.000  54.9        33     34.9     56.8      29     27.8           54.0      -26.2
  V         7416.000  47.7        33     37.9     52.6      29     23.6           54.0      -30.4
  V         9888.000   36.0       33     40.4      43.4     29      14.4           54.0     -39.6
  V        12360.000  39.0        33     40.5     46.5      29     17.5           54.0      -36.5
  V        14832.000   10.9       33     38.4      45.3     29      16.3           54.0     -37.7

                                     Pre-Amp    Antenna       Net at       Peak Limit
 Polari-     Frequency   Reading       Gain      Factor    3m - Peak         at 3m       Margin
 zation         (MHz)    (dBμV)        (dB)       (dB)      (dBμV/m)       (dBμV/m)       (dB)
   V          2472.000    84.7          33        29.4         81.1          114.0       -32.9
   V         2483.500     49.5          33        29.4        45.9           74.0        -28.1
   V         4944.000     54.9          33        34.9        56.8           74.0        -17.2
   V         7416.000     47.7          33        37.9        52.6           74.0        -21.4
   V          9888.000    36.0          33        40.4         43.4           74.0       -30.6
   V         12360.000    39.0          33        40.5        46.5           74.0        -27.5
   V         14832.000    39.9          33        38.4         45.3           74.0       -28.7

NOTES: 1. Peak Detector Data unless otherwise stated.

             2. All measurements were made at 3 meters. Harmonic emissions not
                detected at the 3-meter distances were measured at 0.3-meter and an
                inverse proportional extrapolation was performed to compare the signal
                level to the 3-meter limit. No other harmonic emissions than those
                reported were detected at a test distance of 0.3-meter.

             3. Negative sign in the column shows value below limit.

             4. Horn antenna is used for the emission over 1000MHz.

             5. Emission (the row indicated by bold italic) within the restricted band meets
                the requirement of FCC Part 15 Section 15.205.

             6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 17020969HKG-003                                                                    7 of 16
FCC ID: PQN44615RX2G4


                         INTERTEK TESTING SERVICES

Applicant: Spin Master Toys Far East Ltd.                 Date of Test: March 23, 2017
Model: 44615RX
Worst-Case Operating Mode: Transmitting
                                    Table 4
                             Radiated Emissions
              Pursuant to FCC Part 15 Section 15.209 Requirement

                               Pre- Antenna    Net     Limit
             Frequency Reading amp Factor     at 3m    at 3m                   Margin
Polarization   (MHz)   (dBμV) (dB)   (dB)   (dBμV/m) (dBμV/m)                   (dB)
     V         45.345   27.4    16   10.0     21.4     40.0                    -18.6
     V        134.675   25.5    16   14.0      23.5     43.5                   -20.0
     V        192.734   24.6    16   16.0     24.6     43.5                    -18.9
     V        235.544   22.7    16   19.0     25.7     46.0                    -20.3
     H        345.345   18.8    16   24.0      26.8     46.0                   -19.2
     H        565.545   13.6    16   28.0      25.6     46.0                   -20.4



NOTES: 1. Peak Detector Data unless otherwise stated.

         2. All measurements were made at 3 meters. Harmonic emissions not
            detected at the 3-meter distances were measured at 0.3-meter and an
            inverse proportional extrapolation was performed to compare the signal
            level to the 3-meter limit. No other harmonic emissions than those
            reported were detected at a test distance of 0.3-meter.

         3. Negative sign in the column shows value below limit.

         4. Horn antenna is used for the emission over 1000MHz.

         5. Emission (the row indicated by bold italic) within the restricted band meets
            the requirement of FCC Part 15 Section 15.205.

         6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 17020969HKG-003                                                     8 of 16
FCC ID: PQN44615RX2G4


                         INTERTEK TESTING SERVICES

4.0   Equipment Photographs

      For electronic filing, the photographs are saved with filename: external photos.pdf
      and internal photos.pdf.


5.0   Product Labelling

      For electronics filing, the FCC ID label artwork and the label location are saved
      with filename: label.pdf.


6.0   Technical Specifications

      For electronic filing, the block diagram and schematic of the tested EUT are
      saved with filename: block.pdf and circuit.pdf respectively.


7.0   Instruction Manual

      For electronic filing, a preliminary copy of the Instruction Manual is saved with
      filename: manual.pdf.

      This manual will be provided to the end-user with each unit sold/leased in the
      United States.




Report No.: 17020969HKG-003                                                      9 of 16
FCC ID: PQN44615RX2G4


                        INTERTEK TESTING SERVICES

8.0   Miscellaneous Information

      The miscellaneous information includes details of the test procedure and
      measured bandwidth / calculation of factor such as pulse desensitization and
      averaging factor (calculation and timing diagram).


8.1   Radiated Emission on the Bandedge

      The test data of bandedge emissions were shown on the above radiated
      emissions table 1 & table 3 respectively.

      Emissions radiated outside of the specified frequency bands, except harmonics,
      are attenuated by 50dB below the level of the fundamental or to the general
      radiated emissions limits in Section 15.209, whichever is the lesser attenuation,
      which meet the requirement of part 15.249(d).

      The resultant field strength meets the general radiated emission limit in
      Section 15.209, which does not exceed 74 dBµV/m (Peak Limit) and 54 dBµV/m
      (Average Limit).




Report No.: 17020969HKG-003                                                   10 of 16
FCC ID: PQN44615RX2G4


                        INTERTEK TESTING SERVICES

8.2   Discussion of Pulse Desensitization

      Pulse desensitivity is not applicable for this device. The effective period (Teff)
      is approximately 710 µs for a digital “1” bit which illustrated on technical
      specification, with a resolution bandwidth (3dB) of 1MHz, so the pulse
      desensitivity factor is 0dB.


8.3   Calculation of Average Factor


      The duty cycle is simply the on-time divided by the period:

      The duration of one cycle = 100ms

      Effective period of the cycle = 5*0.71 = 3.55ms

      DC = 3.55/100 = 0.0355ms

      Therefore, the averaging factor is found by 20log 0.0355 = -29.0dB.




Report No.: 17020969HKG-003                                                    11 of 16
FCC ID: PQN44615RX2G4


                      INTERTEK TESTING SERVICES

     Average Factor




Report No.: 17020969HKG-003                       12 of 16
FCC ID: PQN44615RX2G4


                          INTERTEK TESTING SERVICES

8.4   Emissions Test Procedures

      The following is a description of the test procedure used by Intertek Testing
      Services Hong Kong Ltd. in the measurements of transmitter operating under
      the Part 15, Subpart C rules.

      The transmitting equipment under test (EUT) is placed on a wooden turntable
      which is four feet in diameter and approximately 0.8m in height above the
      ground plane for emission measurement at or below 1GHz and 1.5m in height
      above the ground plane for emission measurement above 1GHz. During the
      radiated emissions test, the turntable is rotated and any cables leaving the EUT
      are manipulated to find the configuration resulting in maximum emissions. The
      EUT is adjusted through all three orthogonal axis to obtain maximum emission
      levels. The antenna height and polarization are also varied during the testing to
      search for maximum signal levels. The height of the antenna is varied from
      one to four meters.

      Detector function for radiated emissions is in peak mode. Average readings, when
      required, are taken by measuring the duty cycle of the equipment under test and
      subtracting the corresponding amount in dB from the measured peak readings. A
      detailed description for the calculation of the average factor can be found in Exhibit 8.3.

      The frequency range scanned is from the lowest radio frequency signal
      generated in the device which is greater than 9 kHz to the tenth harmonic of the
      highest fundamental frequency or 40 GHz, whichever is lower.




Report No.: 17020969HKG-003                                                            13 of 16
FCC ID: PQN44615RX2G4


                         INTERTEK TESTING SERVICES

8.4   Emissions Test Procedures (cont’d)

      The EUT is warmed up for 15 minutes prior to the test.

      AC power to the unit is varied from 85% to 115% nominal and variation in the
      fundamental emission field strength is recorded. If battery powered, a new,
      fully charged battery is used.

      Conducted measurements were made as described in ANSI C63.10 (2013).

      The IF bandwidth used for measurement of radiated signal strength was 100 kHz
      or greater when frequency is below 1000 MHz. Where pulsed transmissions of
      short enough pulse duration warrant, a greater bandwidth is selected according
      to the recommendations of Hewlett Packard Application Note 150-2. A discussion
      of whether pulse desensitivity is applicable to this unit is included in this report
      (See Exhibit 8.1). Above 1000 MHz, a resolution bandwidth of 3 MHz is used.

      Transmitter measurements are normally conducted at a measurement distance
      of three meters. However, to assure low enough noise floor in the forbidden
      bands and above 1 GHz, signals are acquired at a distance of one meter or less. All
      measurements are extrapolated to three meters using inverse scaling, unless
      otherwise reported. Measurements taken at a closer distance are so marked.




Report No.: 17020969HKG-003                                                     14 of 16
FCC ID: PQN44615RX2G4


                       INTERTEK TESTING SERVICES

8.4.1 Radiated Emission Test Setup

      The figure below shows the test setup, which is utilized to make these
      measurements.


                                                       Antenna
                                          1.0~4.0m     Tower


                                     3m                     Receiver
                                                            Antenna
                        E
                        U
                        T




          0.8m

                 Ground Plane
       3m Chamber                             □

                                                      RF Test
                                                      Receiver

                 Test setup of radiated emissions up to 1GHz



                                                       Antenna
                                          1.0~4.0m     Tower


                                     3m                     Receiver
                        E
                                                            Antenna
                        U
                        T




          1.5m

                 Ground Plane
                                              □

                                                      RF Test Spectrum
                                                      Analyzer



              Test setup of radiated emissions above 1GHz




Report No.: 17020969HKG-003                                              15 of 16
FCC ID: PQN44615RX2G4


                         INTERTEK TESTING SERVICES

9.0   Equipment List

1)    Radiated Emissions Test

 Equipment              EMI Test Receiver      Spectrum Analyzer
 Registration No.           EW-2666                EW-2188
 Manufacturer                 R&S               AGILENTTECH
 Model No.                   ESCI7                  E4407B
 Calibration Date         Jun. 17, 2016          Apr. 25, 2016
 Calibration Due Date     Jun. 17, 2017          Apr. 25, 2017

 Equipment              Log Periodic Antenna       Biconical Antenna   Double Ridged
                                                                       Guide Antenna
 Registration No.            EW-0447                   EW-0571           EW-1133
 Manufacturer                 EMCO                      EMCO              EMCO
 Model No.                     3146                     3104C              3115
 Calibration Date          May. 18, 2016             May. 18, 2016     Nov. 05, 2015
 Calibration Due Date      Nov. 18, 2017             Nov. 18, 2017     May 05, 2017




                            END OF TEST REPORT




Report No.: 17020969HKG-003                                               16 of 16
FCC ID: PQN44615RX2G4



Document Created: 2017-05-02 12:21:42
Document Modified: 2017-05-02 12:21:42

© 2024 FCC.report