Test Report

FCC ID: PQN44566TX2G4

Test Report

Download: PDF
FCCID_3082408

                                                                 TEST REPORT

                                             Report No.: 16031022HKG-001

                                             Spin Master Toys Far East Ltd.


                                                          Application
                                                              For
                                                          Certification
                                                        (Original Grant)
                                                  (FCC ID: PQN44566TX2G4)

                                                                      Transceiver




Prepared and Checked by:                                                                    Approved by:

                                                                                                               Digitally signed
                                                                                                               by Kenneth Wong
                                                                                                               Location: Intertek
                                                                                                               Testing Services

Signed On File                                                                                                 Hong Kong Ltd.


Leung Sung Tak, Andy                                                                        Wong Kwok Yeung, Kenneth
Assistant Engineer                                                                          Senior Lead Engineer
                                                                                            Date: May 03, 2016




-   Intertek's standard Terms and Conditions can be obtained at our website http://www.intertek.com/terms/.
-   The test report only allows to be revised within the retention period unless further standard or the requirement was noticed.
-   This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and
    liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the
    agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and
    then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be
    approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the
    material, product, or service is or has ever been under an Intertek certification program.
-   © 2016 Intertek




                                                  Intertek Testing Services Hong Kong Ltd.
                                          2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                                Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


                        INTERTEK TESTING SERVICES



                         GENERAL INFORMATION


Grantee:                    Spin Master Toys Far East Ltd.
Grantee Address:            Room 1113, 11/F., Chinachem Golden Plaza,
                            77 Mody Road, Tsim Sha Tsui East,
                            Kowloon, Hong Kong.
Contact Person:             Andy Wong
Tel:                        (86)0769-81080068
Fax:                        (86)0769-82207100
e-mail:                     andyw@spinmaster.com
Manufacturer:               Spin Master Toys Far East Ltd.
Manufacturer Address:       Room 1113, 11/F., Chinachem Golden Plaza,
                            77 Mody Road, Tsim Sha Tsui East,
                            Kowloon, Hong Kong.
Brand Name:                 Spin Master LTD.
Model:                      44566
Type of EUT:                Transceiver
Description of EUT:         Star Trek Enterprise Quad (Date Code: 60314AWS)
Serial Number:              N/A
FCC ID:                     PQN44566TX2G4
Date of Sample Submitted:   March 21, 2016
Date of Test:               March 21, 2016 to April 18, 2016
Report No.:                 16031022HKG-001
Report Date:                May 03, 2016
Environmental Conditions:   Temperature: +10 to 40°C
                            Humidity: 10 to 90%




Report No.: 16031022HKG-001                                                   i
FCC ID: PQN44566TX2G4


                              INTERTEK TESTING SERVICES



                               SUMMARY OF TEST RESULT


           TEST SPECIFICATION                                    REFERENCE                RESULTS
 Radiated Emission
                                                                 15.249, 15.209              Pass
 Radiated Emission on the Bandedge
 Radiated Emission in Restricted Bands                                15.205                 Pass

The equipment under test is found to be complying with the following standards:
FCC Part 15, October 1, 2014 Edition




 Note: 1. The EUT uses a permanently attached antenna which, in accordance to section 15.203, is
          considered sufficient to comply with the pervisions of this section.
       2. Pursuant to FCC part 15 Section 15.215(c), the 20 dB bandwidth of the emission was contained
          within the frequency band designated (mentioned as above) which the EUT operated. The
          effects, if any, from frequency sweeping, frequency hopping, other modulation techniques and
          frequency stability over excepted variations in temperature and supply voltage were considered.




Report No.: 16031022HKG-001                                                                            ii
FCC ID: PQN44566TX2G4


                                    INTERTEK TESTING SERVICES



                                               Table of Contents

1.0   General Description .............................................................................................. 1
  1.1  Product Description ............................................................................................. 1
  1.2  Related Submittal(s) Grants................................................................................. 1
  1.3  Test Methodology ................................................................................................ 1
  1.4  Test Facility ......................................................................................................... 1

2.0   System Test Configuration................................................................................... 2
  2.1   Justification .......................................................................................................... 2
  2.2   EUT Exercising Software ..................................................................................... 2
  2.3   Special Accessories ............................................................................................ 2
  2.4   Measurement Uncertainty.................................................................................... 2
  2.5   Support Equipment List and Description .............................................................. 2

3.0   Emission Results .................................................................................................. 3
  3.1  Field Strength Calculation .................................................................................... 3
  3.2  Radiated Emission Configuration Photograph ..................................................... 4
  3.3  Radiated Emission Data ...................................................................................... 4

4.0       Equipment Photographs....................................................................................... 8

5.0       Product Labelling .................................................................................................. 8

6.0       Technical Specifications ...................................................................................... 8

7.0       Instruction Manual ................................................................................................ 8

8.0   Miscellaneous Information ................................................................................... 9
  8.1   Measured Bandwidth / Radiated Emission on the Bandedge .............................. 9
  8.2   Discussion of Pulse Desensitization .................................................................. 10
  8.3   Calculation of Average Factor............................................................................ 10
  8.4   Emissions Test Procedures ............................................................................... 12

9.0       Equipment List .................................................................................................... 15




Report No.: 16031022HKG-001                                                                                               iii
FCC ID: PQN44566TX2G4


                          INTERTEK TESTING SERVICES

1.0   General Description

1.1   Product Description

      The Equipment Under Test (EUT) is a portable 2.4GHz Transceiver (Controller
      Unit) for a RC plane operating at the frequency range of 2407-2477MHz
      including 26 channels, which are shown as below:

        2407    2408     2409     2410     2411     2413     2435        2436   2438     2440
        2441    2442     2443     2444     2445     2467     2468        2469   2470     2471
        2472    2473     2474     2475     2476     2477
.
      The EUT is powered by 4 * 1.5V AA batteries. After switch on the EUT and
      paired with plane, the plane can be controlled to fly forward/ backward and turn
      left/ right by the controller.

      Antenna Type: Internal, Integral

      For electronic filing, the brief circuit description is saved with filename: descri.pdf.


1.2   Related Submittal(s) Grants

      This is a single application for certification of a transceiver.

      The Certification procedure of transceiver for this transmitter (with FCC ID:
      PQN44566RX2G4) is being processed as the same time of this application.


1.3   Test Methodology

      Radiated emission measurements was performed according to the
      procedures in ANSI C63.10 (2013).         All radiated measurements were
      performed in an 3m Chamber. Preliminary scans were performed in the
      3m Chamber only to determine worst case modes. All radiated tests were
      performed at an antenna to EUT distance of 3 meters, unless stated
      otherwise in the “Justification Section” of this Application.


1.4   Test Facility

      The 3m Chamber facility used to collect the radiated data is located at
      Workshop No. 3, G/F., World-Wide Industrial Centre, 43-47 Shan Mei Street, Fo
      Tan, Sha Tin, N.T., Hong Kong. This test facility and site measurement data
      have been placed on file with the FCC.




Report No.: 16031022HKG-001                                                            1 of 15
FCC ID: PQN44566TX2G4


                        INTERTEK TESTING SERVICES

2.0   System Test Configuration

2.1   Justification

      The system was configured for testing in a typical fashion (as a customer would
      normally use it), and in the confines as outlined in ANSI C63.10 (2013).

      The device was powered by new 4*1.5 AA batteries.

      For maximizing emissions, the EUT was rotated through 360°, the antenna
      height was varied from 1 meter to 4 meters above the ground plane, and the
      antenna polarization was changed. This step by step procedure for maximizing
      emissions led to the data reported in Exhibit 3.0.

      The unit was operated standalone and placed in the center of the turntable.

      The equipment under test (EUT) was configured for testing in a typical fashion
      (as a customer would normally use it). The EUT was mounted to a plastic stand
      if necessary and placed on the wooden turntable, which enabled the engineer to
      maximize emissions through its placement in the three orthogonal axes.


2.2   EUT Exercising Software

      There was no special software to exercise the device.         Once the unit is
      powered up, it transmits the RF signal continuously.


2.3   Special Accessories

      There are no special accessories necessary for compliance of this product.


2.4   Measurement Uncertainty

      When determining of the test conclusion, the Measurement Uncertainty of test
      has been considered.

      Uncertainty and Compliance - Unless the standard specifically states that
      measured values are to be extended by the measurement uncertainty in
      determining compliance, all compliance determinations are based on the actual
      measured value.


2.5   Support Equipment List and Description

      N/A.




Report No.: 16031022HKG-001                                                   2 of 15
FCC ID: PQN44566TX2G4


                          INTERTEK TESTING SERVICES

3.0   Emission Results

      Data is included of the worst case configuration (the configuration which resulted
      in the highest emission levels). A sample calculation, configuration photographs
      and data tables of the emissions are included.


3.1   Field Strength Calculation

      The field strength is calculated by adding the Antenna Factor and Cable Factor,
      and subtracting the Amplifier Gain (if any), Average Factor (optional) from the
      measured reading. The basic equation with a sample calculation is as follows:
      FS = RA + AF + CF - AG - AV
      where          FS = Field Strength in dBµV/m
                     RA = Receiver Amplitude (including preamplifier) in dBµV
                     CF = Cable Attenuation Factor in dB
                     AF = Antenna Factor in dB
                     AG = Amplifier Gain in dB
                     AV = Average Factor in dB

      In the following table(s), the reading shown on the data table reflects the preamplifier
      gain. An example for the calculations in the following table is as follows:
      FS = RR + LF
      where           FS = Field Strength in dBµV/m
                      RR = RA - AG - AV in dBµV
                      LF = CF + AF in dB

      Assume a receiver reading of 52.0 dBµV is obtained. The antenna factor of
      7.4 dB and cable factor of 1.6 dB are added. The amplifier gain of 29 dB and
      average factor of 5 dB are subtracted, giving a field strength of 27 dBµV/m.
      This value in dBµV/m was converted to its corresponding level in µV/m.

      RA = 52.0 dBµV/m
      AF = 7.4 dB                           RR = 18.0 dBµV
      CF = 1.6 dB                           LF = 9.0 dB
      AG = 29.0 dB
      AV = 5.0 dB
      FS = RR + LF
      FS = 18 + 9 = 27 dBµV/m

      Level in µV/m = Common Antilogarithm [(27 dBµV/m)/20] = 22.4 µV/m




Report No.: 16031022HKG-001                                                          3 of 15
FCC ID: PQN44566TX2G4


                        INTERTEK TESTING SERVICES

3.2   Radiated Emission Configuration Photograph

      The worst case in radiated emission was found at 9768 MHz

      For electronic filing, the worst case radiated emission configuration photographs
      are saved with filename: radiated photos.pdf.


3.3   Radiated Emission Data

      The data on the following page lists the significant emission frequencies, the
      limit and the margin of compliance. Numbers with a minus sign are below the
      limit.

      Judgment: Passed by 13.2 dB




Report No.: 16031022HKG-001                                                    4 of 15
FCC ID: PQN44566TX2G4


                              INTERTEK TESTING SERVICES

Applicant: Spin Master Toys Far East Ltd.                         Date of Test: April 18, 2016
Model: 44566
Worst-Case Operating Mode: Transmitting
                                       Table 1
                                Radiated Emissions
                 Pursuant to FCC Part 15 Section 15.249 Requirement
Lowest Channel
                              Pre-Amp Antenna   Net at  Average Calculated   Average Limit
Polari- Frequency   Reading     Gain   Factor 3m - Peak Factor    at 3m          at 3m        Margin
zation     (MHz)    (dBμV)      (dB)    (dB)  (dBμV/m)    (dB)  (dBμV/m)       (dBμV/m)        (dB)
  H      2407.000     99.3       33     29.4     95.7    28.5      67.2           94.0        -26.8
  V      2400.000     63.2       33     29.4     59.6    28.5      31.1           54.0        -22.9
  H      4814.000    43.9        33     34.9    45.8     28.5     17.3           54.0         -36.7
  H      7221.000     42.7       33     37.9     47.6    28.5      19.1           54.0        -35.0
  H      9628.000     52.7       33     40.4     60.1    28.5      31.6           54.0        -22.4
  H     12035.000    43.0        33     40.5    50.5     28.5     22.0           54.0         -32.0
  H     14442.000     44.1       33     40.0     51.1    28.5      22.6           54.0        -31.4

                                    Pre-Amp    Antenna      Net at      Peak Limit
 Polari-   Frequency    Reading       Gain      Factor    3m - Peak       at 3m          Margin
 zation       (MHz)     (dBμV)        (dB)       (dB)     (dBμV/m)      (dBμV/m)          (dB)
   H        2407.000     99.3          33        29.4        95.7         114.0          -18.3
   V        2400.000     63.2          33        29.4        59.6          74.0          -14.4
   H        4814.000     43.9          33        34.9       45.8          74.0           -28.2
   H        7221.000     42.7          33        37.9        47.6          74.0          -26.5
   H        9628.000     52.7          33        40.4        60.1          74.0          -13.9
   H       12035.000     43.0          33        40.5       50.5          74.0           -23.5
   H       14442.000     44.1          33        40.0        51.1          74.0          -22.9



NOTES: 1. Peak Detector Data unless otherwise stated.

           2. All measurements were made at 3 meters. Harmonic emissions not
              detected at the 3-meter distances were measured at 0.3-meter and an
              inverse proportional extrapolation was performed to compare the signal
              level to the 3-meter limit. No other harmonic emissions than those
              reported were detected at a test distance of 0.3-meter.

           3. Negative sign in the column shows value below limit.

           4. Horn antenna is used for the emission over 1000MHz.

           5. Emission (the row indicated by bold italic) within the restricted band meets
              the requirement of FCC Part 15 Section 15.205.

           6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 16031022HKG-001                                                                  5 of 15
FCC ID: PQN44566TX2G4


                              INTERTEK TESTING SERVICES

Applicant: Spin Master Toys Far East Ltd.                         Date of Test: April 18, 2016
Model: 44566
Worst-Case Operating Mode: Transmitting
                                       Table 2
                                Radiated Emissions
                 Pursuant to FCC Part 15 Section 15.249 Requirement
Middle Channel
                              Pre-Amp Antenna   Net at  Average Calculated   Average Limit
Polari- Frequency   Reading     Gain   Factor 3m - Peak Factor    at 3m          at 3m        Margin
zation     (MHz)    (dBμV)      (dB)    (dB)  (dBμV/m)    (dB)  (dBμV/m)       (dBμV/m)        (dB)
  H      2442.000     99.3       33     29.4     95.7    28.5      67.2           94.0        -26.8
  H      4884.000    43.6        33     34.9    45.5     28.5     17.0           54.0         -37.0
  H      7326.000    39.9        33     37.9    44.8     28.5     16.3           54.0         -37.7
  H      9768.000     53.4       33     40.4     60.8    28.5      32.3           54.0        -21.7
  H     12210.000    43.1        33     40.5    50.6     28.5     22.1           54.0         -31.9
  H     14652.000     46.0       33     38.4     51.4    28.5      22.9           54.0        -31.1

                                    Pre-Amp    Antenna      Net at      Peak Limit
 Polari-   Frequency    Reading       Gain      Factor    3m - Peak       at 3m          Margin
 zation       (MHz)     (dBμV)        (dB)       (dB)     (dBμV/m)      (dBμV/m)          (dB)
   H        2442.000     99.3          33        29.4        95.7         114.0          -18.3
   H        4884.000     43.6          33        34.9       45.5          74.0           -28.5
   H        7326.000     39.9          33        37.9       44.8          74.0           -29.2
   H        9768.000     53.4          33        40.4        60.8          74.0          -13.2
   H       12210.000     43.1          33        40.5       50.6          74.0           -23.4
   H       14652.000     46.0          33        38.4        51.4          74.0          -22.6

NOTES: 1. Peak Detector Data unless otherwise stated.

           2. All measurements were made at 3 meters. Harmonic emissions not
              detected at the 3-meter distances were measured at 0.3-meter and an
              inverse proportional extrapolation was performed to compare the signal
              level to the 3-meter limit. No other harmonic emissions than those
              reported were detected at a test distance of 0.3-meter.

           3. Negative sign in the column shows value below limit.

           4. Horn antenna is used for the emission over 1000MHz.

           5. Emission (the row indicated by bold italic) within the restricted band meets
              the requirement of FCC Part 15 Section 15.205.
           6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 16031022HKG-001                                                                  6 of 15
FCC ID: PQN44566TX2G4


                                INTERTEK TESTING SERVICES

Applicant: Spin Master Toys Far East Ltd.                              Date of Test: April 18, 2016
Model: 44566
Worst-Case Operating Mode: Transmitting
                                          Table 3
                                   Radiated Emissions
                    Pursuant to FCC Part 15 Section 15.249 Requirement
Highest Channel
                               Pre-Amp Antenna   Net at  Average Calculated   Average Limit
Polari-    Frequency Reading     Gain   Factor 3m - Peak Factor    at 3m          at 3m     Margin
zation        (MHz)  (dBμV)      (dB)    (dB)  (dBμV/m)    (dB)  (dBμV/m)       (dBμV/m)     (dB)
  H         2477.000   99.4       33     29.4     95.8    28.5      67.3           94.0     -26.7
  H         2483.500  63.4        33     29.4    59.8     28.5     31.3           54.0      -22.7
  H         4954.000  47.4        33     34.9    49.3     28.5     20.8           54.0      -33.2
  H         7431.000  38.7        33     37.9    43.6     28.5     15.1           54.0      -38.9
  H         9908.000   49.3       33     40.4     56.7    28.5      28.2           54.0     -25.8
  H        12385.000  42.3        33     40.5    49.8     28.5     21.3           54.0      -32.7
  H        14862.000   45.0       33     38.4     50.4    28.5      21.9           54.0     -32.1

                                     Pre-Amp    Antenna      Net at      Peak Limit
 Polari-     Frequency   Reading       Gain      Factor    3m - Peak       at 3m         Margin
 zation         (MHz)    (dBμV)        (dB)       (dB)     (dBμV/m)      (dBμV/m)         (dB)
   H          2477.000    99.4          33        29.4        95.8         114.0         -18.2
   H         2483.500     63.4          33        29.4       59.8          74.0          -14.2
   H         4954.000     47.4          33        34.9       49.3          74.0          -24.7
   H         7431.000     38.7          33        37.9       43.6          74.0          -30.4
   H          9908.000    49.3          33        40.4        56.7          74.0         -17.3
   H         12385.000    42.3          33        40.5       49.8          74.0          -24.2
   H         14862.000    45.0          33        38.4        50.4          74.0         -23.6


NOTES: 1. Peak Detector Data unless otherwise stated.

             2. All measurements were made at 3 meters. Harmonic emissions not
                detected at the 3-meter distances were measured at 0.3-meter and an
                inverse proportional extrapolation was performed to compare the signal
                level to the 3-meter limit. No other harmonic emissions than those
                reported were detected at a test distance of 0.3-meter.

             3. Negative sign in the column shows value below limit.

             4. Horn antenna is used for the emission over 1000MHz.

             5. Emission (the row indicated by bold italic) within the restricted band meets
                the requirement of FCC Part 15 Section 15.205.

             6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 16031022HKG-001                                                                    7 of 15
FCC ID: PQN44566TX2G4


                         INTERTEK TESTING SERVICES


4.0   Equipment Photographs

      For electronic filing, the photographs are saved with filename: external photos.pdf
      and internal photos.pdf.


5.0   Product Labelling

      For electronics filing, the FCC ID label artwork and the label location are saved
      with filename: label.pdf.


6.0   Technical Specifications

      For electronic filing, the block diagram and schematic of the tested EUT are
      saved with filename: block.pdf and circuit.pdf respectively.


7.0   Instruction Manual

      For electronic filing, a preliminary copy of the Instruction Manual is saved with
      filename: manual.pdf.

      This manual will be provided to the end-user with each unit sold/leased in the
      United States.




Report No.: 16031022HKG-001                                                      8 of 15
FCC ID: PQN44566TX2G4


                        INTERTEK TESTING SERVICES

8.0   Miscellaneous Information

      The miscellaneous information includes details of the test procedure and
      measured bandwidth / calculation of factor such as pulse desensitization and
      averaging factor (calculation and timing diagram).


8.1   Radiated Emission on the Bandedge

      The test data of bandedge emissions were shown on the above radiated
      emissions table 1 & table 3 respectively.

      Emissions radiated outside of the specified frequency bands, except harmonics,
      are attenuated by 50dB below the level of the fundamental or to the general
      radiated emissions limits in Section 15.209, whichever is the lesser attenuation,
      which meet the requirement of part 15.249(d).

      The resultant field strength meets the general radiated emission limit in section
      15.209, which does not exceed 74 dBμV/m (Peak Limit) but exceeded 54
      dBμV/m (Average Limit).




Report No.: 16031022HKG-001                                                    9 of 15
FCC ID: PQN44566TX2G4


                        INTERTEK TESTING SERVICES

8.2   Discussion of Pulse Desensitization

      Pulse desensitivity is not applicable for this device. The effective period (Teff)
      is approximately 735 µs for a digital “1” bit which illustrated on technical
      specification, with a resolution bandwidth (3dB) of 1MHz, so the pulse
      desensitivity factor is 0dB.


8.3   Calculation of Average Factor


      The duty cycle is simply the on-time divided by the period:

      The duration of one cycle = 100ms

      Effective period of the cycle = 5*0.753 = 3.765ms

      DC = 3.765/100 = 0.03765ms

      Therefore, the averaging factor is found by 20log 0.03765 = -28.5dB.




Report No.: 16031022HKG-001                                                    10 of 15
FCC ID: PQN44566TX2G4


                              INTERTEK TESTING SERVICES

     Average Factor `
                                                         RBW 1 MHz    Marker 1 [T1 ]
                                                         VBW 3 MHz              -19.05 dBm
             Ref -10 dBm               Att   20 dB       SWT 2.5 ms         735.000000 µs
             -10
                                   1
                                                                                             A
             -20

      1 PK
      MAXH                                                                                   TRG
             -30


                    TRG -38 dBm
             -40



             -50



             -60

                                                                                             3DB
             -70



             -80



             -90



             -100


             -110

             Center 2.442418 GHz                     250 µs/




                                                         RBW 1 MHz
                                                         VBW 3 MHz
             Ref -10 dBm               Att   20 dB       SWT 100 ms
             -10

                                                                                              A
             -20
                                                                                             SGL
      1 PK
      MAXH                                                                                   TRG
             -30


                    TRG -38 dBm
             -40



             -50



             -60

                                                                                             3DB
             -70



             -80



             -90



             -100


             -110

             Center 2.442418 GHz                     10 ms/




Report No.: 16031022HKG-001                                                                        11 of 15
FCC ID: PQN44566TX2G4


                          INTERTEK TESTING SERVICES

8.4   Emissions Test Procedures

      The following is a description of the test procedure used by Intertek Testing
      Services Hong Kong Ltd. in the measurements of transmitter operating under
      the Part 15, Subpart C rules.

      The transmitting equipment under test (EUT) is placed on a wooden turntable
      which is four feet in diameter and approximately 0.8m in height above the
      ground plane for emission measurement at or below 1GHz and 1.5m in height
      above the ground plane for emission measurement above 1GHz. During the
      radiated emissions test, the turntable is rotated and any cables leaving the EUT
      are manipulated to find the configuration resulting in maximum emissions. The
      EUT is adjusted through all three orthogonal axis to obtain maximum emission
      levels. The antenna height and polarization are also varied during the testing to
      search for maximum signal levels. The height of the antenna is varied from
      one to four meters.

      Detector function for radiated emissions is in peak mode. Average readings, when
      required, are taken by measuring the duty cycle of the equipment under test and
      subtracting the corresponding amount in dB from the measured peak readings. A
      detailed description for the calculation of the average factor can be found in Exhibit 8.3.

      The frequency range scanned is from the lowest radio frequency signal
      generated in the device which is greater than 9 kHz to the tenth harmonic of the
      highest fundamental frequency or 40 GHz, whichever is lower.




Report No.: 16031022HKG-001                                                            12 of 15
FCC ID: PQN44566TX2G4


                         INTERTEK TESTING SERVICES

8.4   Emissions Test Procedures (cont’d)

      The EUT is warmed up for 15 minutes prior to the test.

      AC power to the unit is varied from 85% to 115% nominal and variation in the
      fundamental emission field strength is recorded. If battery powered, a new,
      fully charged battery is used.

      Conducted measurements were made as described in ANSI C63.10 (2013).

      The IF bandwidth used for measurement of radiated signal strength was 100 kHz
      or greater when frequency is below 1000 MHz. Where pulsed transmissions of
      short enough pulse duration warrant, a greater bandwidth is selected according
      to the recommendations of Hewlett Packard Application Note 150-2. A discussion
      of whether pulse desensitivity is applicable to this unit is included in this report
      (See Exhibit 8.1). Above 1000 MHz, a resolution bandwidth of 10 MHz is used.

      Transmitter measurements are normally conducted at a measurement distance
      of three meters. However, to assure low enough noise floor in the forbidden
      bands and above 1 GHz, signals are acquired at a distance of one meter or less. All
      measurements are extrapolated to three meters using inverse scaling, unless
      otherwise reported. Measurements taken at a closer distance are so marked.




Report No.: 16031022HKG-001                                                     13 of 15
FCC ID: PQN44566TX2G4


                       INTERTEK TESTING SERVICES

8.4.1 Radiated Emission Test Setup

      The figure below shows the test setup, which is utilized to make these
      measurements.


                                                       Antenna
                                          1.0~4.0m     Tower


                                     3m                     Receiver
                                                            Antenna
                        E
                        U
                        T




          0.8m

                 Ground Plane
       3m Chamber                             □

                                                      RF Test
                                                      Receiver

                 Test setup of radiated emissions up to 1GHz



                                                       Antenna
                                          1.0~4.0m     Tower


                                     3m                     Receiver
                        E
                                                            Antenna
                        U
                        T




          1.5m

                 Ground Plane
                                              □

                                                      RF Test Spectrum
                                                      Analyzer



              Test setup of radiated emissions above 1GHz




Report No.: 16031022HKG-001                                              14 of 15
FCC ID: PQN44566TX2G4


                         INTERTEK TESTING SERVICES

9.0   Equipment List

1)    Radiated Emissions Test

 Equipment              EMI Test Receiver   Spectrum Analyzer   BiConiLog Antenna
 Registration No.           EW-3156             EW-2253              EW-3061
 Manufacturer                 R&S                  R&S                EMCO
 Model No.                   ESR26               FSP40                 3412E
 Calibration Date        Nov. 03, 2015        May 27, 2015         Jul. 22, 2015
 Calibration Due Date    Nov. 03, 2016        May 27, 2016         Jul. 22, 2016

 Equipment              Double Ridged Guide
                              Antenna
 Registration No.            EW-0194
 Manufacturer                 EMCO
 Model No.                      3115
 Calibration Date          Jan. 29, 2015
 Calibration Due Date      Jul. 29, 2016

2)     Average Factor Measurement

 Equipment              Spectrum Analyzer
 Registration No.           EW-2329
 Manufacturer                  R&S
 Model No.                    FSP3
 Calibration Date         Jun. 17, 2015
 Calibration Due Date     Jun. 17, 2016




                            END OF TEST REPORT




Report No.: 16031022HKG-001                                                15 of 15
FCC ID: PQN44566TX2G4



Document Created: 2016-05-13 11:12:00
Document Modified: 2016-05-13 11:12:00

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC