Test Report

FCC ID: PQN44548TX2G4

Test Report

Download: PDF
FCCID_2604449

    Intertek
Valued Quality. Delivered.

Issuing Laboratory:                                                                                                                                           H
Intertek Testing Services Hong Kong Limited                                                                                                                   g
HKAS has accredited this laboratory (HOKLAS 005 —— TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.

                                                                                                                                                           TEST




                                                                  TEST REPORT

                                               Report No.: 15010735HKG—001

                                               Spin Master Toys Far East Ltd.


                                                           Application
                                                                For
                                                           Certification
                                                         (Original Grant)
                                                   (FCC ID: PQN44548TX2G4)

                                                                       Transceiver




Prepared and Checked by:                                                                     Approved by:




Wong Kwok Yeung, Kenneth                                                                     Chan C€hi Hung, Terry
Lead Engineer                                                                                Senior Supervisor
                                                                                             Date: April 10, 2015



—    Intertek‘s standard Terms and Conditions can be obtained at our website http:/www.intertek.com/terms/.
—    This report shall not be reproduced, except in full
—    This report is for the exclusive use of Intertek‘s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek‘s responsibility and
     liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the
     agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and
     then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be
     approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the
     material, product, or service is or has ever been under an Intertek certification program.




                                                   Intertek Testing Services Hong Kong Ltd.
                                           2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                                 Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek—etIsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




                                             GENERAL INFORMATION


 Grantee:                                        Spin Master Toys Far East Ltd.
 Grantee Address:                                Room 1113, 11/F., Chinachem Golden Plaza,
                                                 77 Mody Road, Tsim Sha Tsui East,
                                                 Kowloon, Hong Kong.
 Contact Person:                                 Andy Wong
 Tel:                                            0769-81080068-1123
 Fax:                                            0769-81080061
 e-mail:                                         andyw@spinmaster.com
 Manufacturer:                                   Spin Master Toys
 Manufacturer Address:                           Room 1113A, 11/F., Chinachem Golden Plaza,
                                                 77 Mody Road, Tsim Sha Tsui East,
                                                 Kowloon, Hong Kong.
 Brand Name:                                     AIR Hogs
 Model:                                          44548TX
 Additional Model:                               6026517, 6026518, 1035754, 1035755
 Phantom No.:                                    20070590/ 20070591/ 20070592/ 20070593
 Type of EUT:                                    Transceiver
 Description of EUT:                             ARH RDC Helix Ion Drone2.4 Ast
 Serial Number:                                  N/A
 FCC ID:                                         PQN44548TX2G4
 Date of Sample Submitted:                       January 20, 2015
 Date of Test:                                   January 20, 2015 to February 06, 2015
 Report No.:                                     15010735HKG-001
 Report Date:                                    April 10, 2015
 Environmental Conditions:                       Temperature: +10 to 40°C
                                                 Humidity: 10 to 90%




Report No.: 15010735HKG-001                                                                                  i
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




                                         SUMMARY OF TEST RESULT


                           TEST SPECIFICATION                                              REFERENCE RESULTS
 Transmitter Power Line Conducted Emissions                                                      15.207      Pass
 Radiated Emission in Restricted Bands                                                           15.205      Pass
 Radiated Emission
                                                                                                 15.249      Pass
 Radiated Emission on the Bandedge

The equipment under test is found to be complying with the following standards:
FCC Part 15, October 1, 2013 Edition




 Note: 1. The EUT uses a permanently attached antenna which, in accordance to section 15.203, is
          considered sufficient to comply with the pervisions of this section.
       2. Pursuant to FCC part 15 Section 15.215(c), the 20 dB bandwidth of the emission was contained
          within the frequency band designated (mentioned as above) which the EUT operated. The
          effects, if any, from frequency sweeping, frequency hopping, other modulation techniques and
          frequency stability over excepted variations in temperature and supply voltage were considered.




Report No.: 15010735HKG-001                                                                                         ii
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




                                                    Table of Contents

1.0   General Description .............................................................................................. 1
  1.1  Product Description ............................................................................................. 1
  1.2  Related Submittal(s) Grants................................................................................. 1
  1.3  Test Methodology ................................................................................................ 1
  1.4  Test Facility ......................................................................................................... 2

2.0   System Test Configuration................................................................................... 3
  2.1   Justification.......................................................................................................... 3
  2.2   EUT Exercising Software..................................................................................... 3
  2.3   Special Accessories ............................................................................................ 3
  2.4   Measurement Uncertainty.................................................................................... 3
  2.5   Support Equipment List and Description.............................................................. 3

3.0   Emission Results .................................................................................................. 4
  3.1  Field Strength Calculation.................................................................................... 4
  3.2  Radiated Emission Configuration Photograph ..................................................... 5
  3.3  Radiated Emission Data ...................................................................................... 5

4.0       Equipment Photographs....................................................................................... 9

5.0       Product Labelling.................................................................................................. 9

6.0       Technical Specifications ...................................................................................... 9

7.0       Instruction Manual ................................................................................................ 9

8.0   Miscellaneous Information ................................................................................. 10
  8.1   Radiated Emission on the Bandedge................................................................. 10
  8.2   Discussion of Pulse Desensitization .................................................................. 13
  8.3   Calculation of Average Factor............................................................................ 13
  8.4   Emissions Test Procedures ............................................................................... 15

9.0       Equipment List .................................................................................................... 18




Report No.: 15010735HKG-001                                                                                              iii
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




1.0       General Description

1.1       Product Description

          The Equipment Under Test (EUT) is a 2.4GHz Transceiver (Controller Unit) for a
          RC helicopter operating at 2412 ~ 2470MHz with 2MHz Channel spacing. The
          EUT is powered by 4 X 1.5V AA batteries. After switch on the EUT and paired
          with helicopter, the helicopter can be controlled to fly forward, backward, turning
          left/right direction and rolling by the controller. Also, the EUT has a charging
          circuitry, the corresponding receiver can be charged by this controller.

          The Model: 6026517, 6026518, 1035754 and 1035755 are the same as the
          Model: 44548TX in hardware aspect. The models are different in model
          number only.

          Antenna Type: Internal, Integral

          For electronic filing, the brief circuit description is saved with filename: descri.pdf.


1.2       Related Submittal(s) Grants

          The Certification procedure of transceiver (Helicopter) for this transceiver
          (Controller) with FCC ID: PQN44548RX2G4 is being processed as the same
          time of this application.


1.3       Test Methodology

          Radiated emission measurements was performed according to the
          procedures in ANSI C63.4 (2009).          All radiated measurements were
          performed in an 3m Chamber. Preliminary scans were performed in the 3m
          Chamber only to determine worst case modes. All radiated tests were
          performed at an antenna to EUT distance of 3 meters, unless stated
          otherwise in the “Justification Section” of this Application.




Report No.: 15010735HKG-001                                                                                  1
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




1.4       Test Facility

          The 3m Chamber measurement facility used to collect the radiated data is
          located at the Workshop No. 3, G/F., World-Wide Industrial Centre, 43-47 Shan
          Mei Street, Fo Tan, Sha Tin, N.T., Hong Kong. This test facility and site
          measurement data have been placed on file with the FCC.




Report No.: 15010735HKG-001                                                                                  2
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




2.0       System Test Configuration

2.1       Justification

          The system was configured for testing in a typical fashion (as a customer would
          normally use it), and in the confines as outlined in ANSI C63.4 (2009).

          The device was powered by new 4 X 1.5 AA size batteries.

          For maximizing emissions, the EUT was rotated through 360°, the antenna
          height was varied from 1 meter to 4 meters above the ground plane, and the
          antenna polarization was changed. This step by step procedure for maximizing
          emissions led to the data reported in Exhibit 3.0.

          The unit was operated standalone and placed in the center of the turntable.

          The equipment under test (EUT) was configured for testing in a typical fashion
          (as a customer would normally use it). The EUT was mounted to a plastic stand
          if necessary and placed on the wooden turntable, which enabled the engineer to
          maximize emissions through its placement in the three orthogonal axes.


2.2       EUT Exercising Software

          There was no special software to exercise the device.                                          Once the unit is
          powered up, it transmits the RF signal continuously.


2.3       Special Accessories

          There are no special accessories necessary for compliance of this product.


2.4       Measurement Uncertainty

          When determining of the test conclusion, the Measurement Uncertainty of test
          has been considered.


2.5       Support Equipment List and Description

          N/A.




Report No.: 15010735HKG-001                                                                                            3
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




3.0       Emission Results

          Data is included of the worst case configuration (the configuration which resulted
          in the highest emission levels). A sample calculation, configuration photographs
          and data tables of the emissions are included.


3.1       Field Strength Calculation

          The field strength is calculated by adding the Antenna Factor and Cable Factor,
          and subtracting the Amplifier Gain (if any), Average Factor (optional) from the
          measured reading. The basic equation with a sample calculation is as follows:
          FS = RA + AF + CF - AG - AV
          where          FS = Field Strength in dBµV/m
                         RA = Receiver Amplitude (including preamplifier) in dBµV
                         CF = Cable Attenuation Factor in dB
                         AF = Antenna Factor in dB
                         AG = Amplifier Gain in dB
                         AV = Average Factor in dB

          In the following table(s), the reading shown on the data table reflects the preamplifier
          gain. An example for the calculations in the following table is as follows:
          FS = RR + LF
          where           FS = Field Strength in dBµV/m
                          RR = RA - AG - AV in dBµV
                          LF = CF + AF in dB

          Assume a receiver reading of 52.0 dBµV is obtained. The antenna factor of
          7.4 dB and cable factor of 1.6 dB are added. The amplifier gain of 29 dB and
          average factor of 5 dB are subtracted, giving a field strength of 27 dBµV/m.
          This value in dBµV/m was converted to its corresponding level in µV/m.

          RA = 52.0 dBµV/m
          AF = 7.4 dB                                            RR = 18.0 dBµV
          CF = 1.6 dB                                            LF = 9.0 dB
          AG = 29.0 dB
          AV = 5.0 dB
          FS = RR + LF
          FS = 18 + 9 = 27 dBµV/m

          Level in µV/m = Common Antilogarithm [(27 dBµV/m)/20] = 22.4 µV/m




Report No.: 15010735HKG-001                                                                                  4
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




3.2       Radiated Emission Configuration Photograph

          The worst case in radiated emission was found at 2483.5 MHz

          For electronic filing, the worst case radiated emission configuration photographs
          are saved with filename: radiated photos.pdf.


3.3       Radiated Emission Data

          The data on the following page lists the significant emission frequencies, the
          limit and the margin of compliance. Numbers with a minus sign are below the
          limit.

          Judgment: Passed by 8.5 dB




Report No.: 15010735HKG-001                                                                                  5
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




 Applicant: Spin Master Toys Far East Ltd.                                              Date of Test: February 06, 2015
Model: 44548TX
Worst-Case Operating Mode: Transmitting

                                                              Table 1

                                       Radiated Emissions
                        Pursuant to FCC Part 15 Section 15.249 Requirement

Lowest Channel
                                       Pre-Amp Antenna   Net at  Average                     Calculated   Average Limit
 Polari- Frequency         Reading       Gain   Factor 3m - Peak Factor                        at 3m          at 3m       Margin
 zation     (MHz)          (dBμV)        (dB)    (dB)  (dBμV/m)    (dB)                      (dBμV/m)       (dBμV/m)        (dB)
   H      2412.000          98.2          33     29.4    94.6      25.7                        68.9            94.0       -25.1
   V     4824.000           60.3          33     34.9    62.2     25.7                         36.5           54.0        -17.5
   V      7236.000          53.8          33     37.9    58.7      25.7                        33.0            54.0        -21.0
   V      9648.000          51.7          33     40.4    59.1      25.7                        33.4            54.0        -20.6
   V     12060.000          50.1          33     40.5    57.6     25.7                         31.9           54.0        -22.1
   V     14472.000          49.6          33     40.0    56.6      25.7                        30.9            54.0       -23.1

                                                 Pre-Amp          Antenna               Net at       Peak Limit
  Polari-     Frequency          Reading           Gain            Factor             3m - Peak        at 3m          Margin
  zation         (MHz)           (dBμV)            (dB)             (dB)              (dBμV/m)       (dBμV/m)           (dB)
    H          2412.000           98.2              33              29.4                94.6           114.0           -19.4
    V         4824.000            60.3              33              34.9                62.2           74.0           -11.8
    V          7236.000           53.8              33              37.9                58.7           74.0            -15.3
    V          9648.000           51.7              33              40.4                59.1           74.0            -14.9
    V         12060.000           50.1              33              40.5                57.6           74.0           -16.4
    V         14472.000           49.6              33              40.0                56.6           74.0            -17.4
NOTES: 1. Peak Detector Data unless otherwise stated.

               2. All measurements were made at 3 meters. Harmonic emissions not detected at
                  the 3-meter distances were measured at 0.3-meter and an inverse proportional
                  extrapolation was performed to compare the signal level to the 3-meter limit.
                  No other harmonic emissions than those reported were detected at a test
                  distance of 0.3-meter.

               3. Negative sign in the column shows value below limit.

               4. Horn antenna is used for the emission over 1000MHz.

               5. Emission (the row indicated by bold italic) within the restricted band meets the
                  requirement of FCC Part 15 Section 15.205 / RSS-210 Section 2.2.

               6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 15010735HKG-001                                                                                                    6
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




Applicant: Spin Master Toys Far East Ltd.                                               Date of Test: February 06, 2015
Model: 44548TX
Worst-Case Operating Mode: Transmitting

                                                              Table 2

                                       Radiated Emissions
                        Pursuant to FCC Part 15 Section 15.249 Requirement

Middle Channel
                                       Pre-Amp Antenna   Net at  Average                     Calculated   Average Limit
 Polari- Frequency         Reading       Gain   Factor 3m - Peak Factor                        at 3m          at 3m       Margin
 zation     (MHz)          (dBμV)        (dB)    (dB)  (dBμV/m)    (dB)                      (dBμV/m)       (dBμV/m)        (dB)
   H      2442.000          97.8          33     29.4    94.2      25.7                        68.5            94.0       -25.5
   V     4884.000           60.4          33     34.9    62.3     25.7                         36.6           54.0        -17.4
   V     7326.000           53.5          33     37.9    58.4     25.7                         32.7           54.0        -21.3
   V      9768.000          51.8          33     40.4    59.2      25.7                        33.5            54.0        -20.5
   V     12210.000          49.8          33     40.5    57.3     25.7                         31.6           54.0        -22.4
   V     14652.000          51.0          33     38.4    56.4      25.7                        30.7            54.0       -23.3

                                                 Pre-Amp          Antenna               Net at       Peak Limit
  Polari-     Frequency          Reading           Gain            Factor             3m - Peak        at 3m          Margin
  zation         (MHz)           (dBμV)            (dB)             (dB)              (dBμV/m)       (dBμV/m)           (dB)
    H          2442.000           97.8              33              29.4                94.2           114.0           -19.8
    V         4884.000            60.4              33              34.9                62.3           74.0           -11.7
    V         7326.000            53.5              33              37.9                58.4           74.0           -15.6
    V          9768.000           51.8              33              40.4                59.2           74.0            -14.8
    V         12210.000           49.8              33              40.5                57.3           74.0           -16.7
    V         14652.000           51.0              33              38.4                56.4           74.0            -17.6

NOTES: 1. Peak Detector Data unless otherwise stated.

               2. All measurements were made at 3 meters. Harmonic emissions not detected at
                  the 3-meter distances were measured at 0.3-meter and an inverse proportional
                  extrapolation was performed to compare the signal level to the 3-meter limit.
                  No other harmonic emissions than those reported were detected at a test
                  distance of 0.3-meter.

               3. Negative sign in the column shows value below limit.

               4. Horn antenna is used for the emission over 1000MHz.

               5. Emission (the row indicated by bold italic) within the restricted band meets the
                  requirement of FCC Part 15 Section 15.205 / RSS-210 Section 2.2.

               6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.



Report No.: 15010735HKG-001                                                                                                    7
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




Applicant: Spin Master Toys Far East Ltd.                                               Date of Test: February 06, 2015
Model: 44548TX
Worst-Case Operating Mode: Transmitting

                                                              Table 3

                                       Radiated Emissions
                        Pursuant to FCC Part 15 Section 15.249 Requirement

Highest Channel
                                       Pre-Amp Antenna   Net at  Average                     Calculated   Average Limit
 Polari- Frequency         Reading       Gain   Factor 3m - Peak Factor                        at 3m          at 3m       Margin
 zation     (MHz)          (dBμV)        (dB)    (dB)  (dBμV/m)    (dB)                      (dBμV/m)       (dBμV/m)        (dB)
   H      2470.000          97.6          33     29.4    94.0      25.7                        68.3            94.0       -25.7
   V     4940.000           60.9          33     34.9    62.8     25.7                         37.1           54.0        -16.9
   V     7410.000           53.9          33     37.9    58.8     25.7                         33.1           54.0        -20.9
   V      9880.000          52.4          33     40.4    59.8      25.7                        34.1            54.0        -19.9
   V     12350.000          50.2          33     40.5    57.7     25.7                         32.0           54.0        -22.0
   V     14820.000          51.5          33     38.4    56.9      25.7                        31.2            54.0       -22.8

                                                 Pre-Amp          Antenna               Net at       Peak Limit
  Polari-     Frequency          Reading           Gain            Factor             3m - Peak        at 3m          Margin
  zation         (MHz)           (dBμV)            (dB)             (dB)              (dBμV/m)       (dBμV/m)           (dB)
    H          2470.000           97.6              33              29.4                94.0           114.0           -20.0
    V         4940.000            60.9              33              34.9                62.8           74.0           -11.2
    V         7410.000            53.9              33              37.9                58.8           74.0           -15.2
    V          9880.000           52.4              33              40.4                59.8           74.0            -14.2
    V         12350.000           50.2              33              40.5                57.7           74.0           -16.3
    V         14820.000           51.5              33              38.4                56.9           74.0            -17.1

NOTES: 1. Peak Detector Data unless otherwise stated.

               2. All measurements were made at 3 meters. Harmonic emissions not detected at
                  the 3-meter distances were measured at 0.3-meter and an inverse proportional
                  extrapolation was performed to compare the signal level to the 3-meter limit.
                  No other harmonic emissions than those reported were detected at a test
                  distance of 0.3-meter.

               3. Negative sign in the column shows value below limit.

               4. Horn antenna is used for the emission over 1000MHz.

               5. Emission (the row indicated by bold italic) within the restricted band meets the
                  requirement of FCC Part 15 Section 15.205 / RSS-210 Section 2.2.

               6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.



Report No.: 15010735HKG-001                                                                                                    8
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




4.0       Equipment Photographs

          For electronic filing, the photographs are saved with filename: external photos.pdf
          and internal photos.pdf.


5.0       Product Labelling

          For electronics filing, the FCC ID label artwork and the label location are saved
          with filename: label.pdf.


6.0       Technical Specifications

          For electronic filing, the block diagram and schematic of the tested EUT are
          saved with filename: block.pdf and circuit.pdf respectively.


7.0       Instruction Manual

          For electronic filing, a preliminary copy of the Instruction Manual is saved with
          filename: manual.pdf.

          This manual will be provided to the end-user with each unit sold/leased in the
          United States.




Report No.: 15010735HKG-001                                                                                  9
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




8.0       Miscellaneous Information

          The miscellaneous information includes details of the test procedure and
          measured bandwidth / calculation of factor such as pulse desensitization and
          averaging factor (calculation and timing diagram).


8.1       Radiated Emission on the Bandedge

          From the following plots, they show that the fundamental emissions are confined
          in the specified band (2400MHz to 2483.5MHz). In case of the fundamental
          emissions are within two standard bandwidths from the bandedge, the delta
          measurement technique is used for determining bandedge compliance.
          Standard bandwidth is the bandwidth specified by ANSI C63.4 (2009) for
          frequency being measured.

          Emissions radiated outside of the specified frequency bands, except harmonics,
          are attenuated by 50dB below the level of the fundamental or to the general
          radiated emissions limits in Section 15.209, whichever is the lesser attenuation,
          which meet the requirement of part 15.249(d).




Report No.: 15010735HKG-001                                                                                  10
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




          Peak Measurement




Report No.: 15010735HKG-001                                                                                  11
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




          Peak Measurement

          Bandedge compliance is determined by applying marker-delta method, i.e.
          (Bandedge Plot).

          Lower bandedge

          Peak Resultant field strength = Fundamental emissions (peak value) – delta
          from the plot

          =94.6 dBµV/m – 29.3 dB
          =65.3 dBµV/m

          Average Resultant field strength = Fundamental emissions (average value) –
          delta from the plot

          =68.9 dBµV/m – 29.3 dB
          =39.6 dBµV/m

          Upper bandedge

          Peak Resultant field strength = Fundamental emissions (peak value) – delta
          from the plot

          =94.0 dBµV/m – 28.5 dB
          =65.5 dBµV/m

          Average Resultant field strength = Fundamental emissions (average value) –
          delta from the plot

          =68.3 dBµV/m – 28.5 dB
          =39.8 dBµV/m

          The resultant field strength meets the general radiated emission limit in
          Section 15.209, which does not exceed 74 dBµV/m (Peak Limit) and 54 dBµV/m
          (Average Limit).




Report No.: 15010735HKG-001                                                                                  12
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




8.2       Discussion of Pulse Desensitization

          Pulse desensitivity is not applicable for this device. The effective period (Teff)
          is approximately 0.74ms for a digital “1” bit which illustrated on technical
          specification, with a resolution bandwidth (3dB) of 1MHz, so the pulse
          desensitivity factor is 0dB.


8.3       Calculation of Average Factor

          The duty cycle is simply the on-time divided by the period:

          The duration of one cycle = 100 ms

          Effective period of the cycle = 7*0.74 = 5.18 ms

          DC = 5.18/100 = 0.0518

          Therefore, the averaging factor is found by 20log 0.0518 = -25.7dB.




Report No.: 15010735HKG-001                                                                                  13
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




          Average Factor




Report No.: 15010735HKG-001                                                                                  14
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




8.4       Emissions Test Procedures

          The following is a description of the test procedure used by Intertek Testing
          Services Hong Kong Ltd. in the measurements of transmitter operating under
          the Part 15, Subpart C rules.

          The transmitting equipment under test (EUT) is placed on a wooden turntable
          which is four feet in diameter and approximately one meter in height above the
          ground plane. During the radiated emissions test, the turntable is rotated and
          any cables leaving the EUT are manipulated to find the configuration resulting in
          maximum emissions. The EUT is adjusted through all three orthogonal axis to
          obtain maximum emission levels. The antenna height and polarization are also
          varied during the testing to search for maximum signal levels. The height of the
          antenna is varied from one to four meters.

          Detector function for radiated emissions is in peak mode. Average readings, when
          required, are taken by measuring the duty cycle of the equipment under test and
          subtracting the corresponding amount in dB from the measured peak readings. A
          detailed description for the calculation of the average factor can be found in Exhibit 8.3.

          The frequency range scanned is from the lowest radio frequency signal
          generated in the device which is greater than 9 kHz to the tenth harmonic of the
          highest fundamental frequency or 40 GHz, whichever is lower. For line
          conducted emissions, the range scanned is 150 kHz to 30 MHz.




Report No.: 15010735HKG-001                                                                                  15
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




8.4       Emissions Test Procedures (cont’d)

          The EUT is warmed up for 15 minutes prior to the test.

          AC power to the unit is varied from 85% to 115% nominal and variation in the
          fundamental emission field strength is recorded. If battery powered, a new,
          fully charged battery is used.

          Conducted measurements were made as described in ANSI C63.4 (2009).

          The IF bandwidth used for measurement of radiated signal strength was 100 kHz
          or greater when frequency is below 1000 MHz. Where pulsed transmissions of
          short enough pulse duration warrant, a greater bandwidth is selected according
          to the recommendations of Hewlett Packard Application Note 150-2. A discussion
          of whether pulse desensitivity is applicable to this unit is included in this report
          (See Exhibit 8.1). Above 1000 MHz, a resolution bandwidth of 3 MHz is used.

          Transmitter measurements are normally conducted at a measurement distance
          of three meters. However, to assure low enough noise floor in the forbidden
          bands and above 1 GHz, signals are acquired at a distance of one meter or less. All
          measurements are extrapolated to three meters using inverse scaling, unless
          otherwise reported. Measurements taken at a closer distance are so marked.




Report No.: 15010735HKG-001                                                                                  16
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




8.4.1 Radiated Emission Test Setup

          The figure below shows the test setup, which is utilized to make these
          measurements.




Report No.: 15010735HKG-001                                                                                  17
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




9.0       Equipment List

1)     Radiated Emissions Test
 Equipment             BiConiLog Antenna -                               EMI Test Receiver             Spectrum Analyzer
                        26MHz to 6000MHz
 Registration No.            EW-3061                                          EW-2500                      EW-2188
 Manufacturer                 EMCO                                              R&S                      AGILENTTECH
 Model No.                     3412E                                            ESCI                        E4407B
 Calibration Date          Jul. 17, 2014                                    Nov. 06, 2014                 Apr. 16, 2014
 Calibration Due Date      Jul. 17, 2015                                    Nov. 06, 2015                 Apr. 16, 2015

 Equipment                           Double Ridged Guide
                                           Antenna
 Registration No.                        EW-1133
 Manufacturer                              EMCO
 Model No.                                  3115
 Calibration Date                      Apr. 30, 2014
 Calibration Due Date                  Oct. 30, 2015

2)     Bandedge & Average Factor Measurement
 Equipment            Spectrum Analyzer
 Registration No.          EW-2329
 Manufacturer                R&S
 Model No.                   FSP3
 Calibration Date        Jun. 19, 2014
 Calibration Due Date    Jun. 19, 2015


                                             END OF TEST REPORT




Report No.: 15010735HKG-001                                                                                           18
FCC ID: PQN44548TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com



Document Created: 2015-05-05 10:00:41
Document Modified: 2015-05-05 10:00:41

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC